• 제목/요약/키워드: Facility and Equipment

검색결과 812건 처리시간 0.023초

K대학병원 병동부 이중복도형의 개선을 위한 사용자 요구 조사연구 (A Study on the User Needs for Renovation of Race Track Type of Nursing Units in K University Hospital)

  • 김영애;임오연;김정신;이종세;안의종
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제19권3호
    • /
    • pp.21-28
    • /
    • 2013
  • Purpose: General hospital in korea is getting large-scaled, specialized and upgraded. So, nursing unit of race track type has been advanced along with a spatial organization, building equipment and environmental approach. This study is to search the guidelines for renovation of nursing unit with race track type in the case of K university hospital in Daejeon. Methods: 9 cases of recently opened general hospital has been analyzed for spatial and environmental design solution. Questionnaires and interviews about user needs of nursing staff, patient and visitors, have been conducted for a nursing care system and facility of nursing units in K university hospital. Results: The user needs are represented as followings. Center core public zone in each floor plan and center core nursing station and supporting areas in nursing unit are good for an adjacency and separation of spatial organization. Toilet of group patient room is necessary to equip for easy, safe and infective aspects, and so toilet install will decrease the patient number and increase the nursing care service. Hall type of station front is good for visibility and observation. It is appropriate to renovate into south facing group patient room for privacy, enough space for nursing care facility and supporting area, enough width of door to move portable medical equipment, room for medical doctor and practical student, noise absorbing of day room. Implications: Upgrading the nursing care service and facility equipment is necessary to reflect the user needs and cooperate with hospital management.

종합병원 진단검사의학과 검사실의 시설 현황 조사 - 300 병상 미만 병원을 중심으로 (A Study on the Facility and Equipment of Laboratory Medicine in General Hospital - Focused on less than three hundred bed hospitals)

  • 김영애
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제25권3호
    • /
    • pp.15-23
    • /
    • 2019
  • Purpose: As the medical laboratories in general hospitals have made an efforts on quality management and employee health, they recognized the need of design guideline for clinical laboratory. As laboratories are prohibited to patients, their environments are becoming more congested and deteriorated as time goes by. So, this study investigates the current status of facility and equipment of laboratory medicine focusing on less than three hundred patient bed hospitals, and searches the improving matters. Methods: Questionnaires to technologist captains and field surveys to medical laboratories in korean hospitals have been conducted for the data collection. 18 answers have been analysed statistically by MS Excel program. Results: The result of this study can be summarized into followings. Clinical laboratory functions are all hematology, clinical chemistry, immunology, transfusion and urine microscopy, and except for three including microbiology for infection and bio safety level. Average man power of lab are 12.3 man including lab director and captain. Patient bed number, space area and total specimen numbers are not correlated with each other, but specimen numbers and employee number are correlated with. Work space distances are usually good, but exit distances are not adequate for escape owing to obstacles. Specimen delivery system by courier, test method by automatic analyzer, access floor for exposed plumbing and electricities are more practical. Open lab layed out in the center and lab support layed peripheral in space diagram. Lab space configuration by SD method showed that lab support area and employee support area are dissatisfied. Implications: Specialized hospital and yearly total specimen numbers are related to the space area and organization for laboratory planning and design.

국내 요양병원의 물리치료실의 효율적 평면계획 및 시설개선에 관한 연구 (A Study of Efficient Floor Planning and Facility Improvement for Physical Therapy Room of Domestic Long-term Hospitals)

  • 정광호
    • 한국디지털건축인테리어학회논문집
    • /
    • 제11권4호
    • /
    • pp.5-11
    • /
    • 2011
  • The present study investigated the actual conditions of physical therapy rooms at long-term hospitals in Korea and conducted a comparative analysis to develop an efficient floor plan and facility improvement measures. 1. At hospitals surveyed, physical therapy services were used at a high frequency but they did not have enough space for rehab treatment and long paths of patient flow were found to make patient management inconvenient. Therefore, physical therapy units should be conveniently located both in terms of distance and direction so as to be accessible from patient rooms or wards. The space should be organized in a concentrated layout for efficiency of physical therapy, and floor planning for therapy units should ensure the best possible viewing angle to therapists. 2. With regard to the disease characteristics of patients, many physical therapy rooms were in difficult circumstances because of poor facilities, so they need to secure skilled personnel, supplement apparatuses and equipment and have rooms for functional recovery, hydrotherapy and operation treatment. In addition, each of the curtained or partitioned areas for treatment should be set up with consideration for the amount of space taken up by medical equipment. The area under each bed should be designed for patient convenience so that it can be used as storage space for patient's belongings and shoes. 3. Patients complained about the lack of physical therapy space, resting places or exercise areas and demanded the expansion of rehab programs and facilities. Physical therapy facilities need to be improved for patient privacy and effective natural ventilation. 4. At most of the long-term hospitals surveyed, physical therapy units were found to have small areas and treatment equipment and devices were insufficient compared to the number of patients. Therefore, it is required to secure more space (at least 138.24 sq. meters per 100 beds) and improve facilities for better physical therapy services.

온도센서를 이용한 전력설비의 온라인 상태 감시 (On-Line Condition Monitoring of Electrical Equipment Using Temperature Sensor)

  • 최용성;김선재;김영민;송환기;이경섭
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.202-208
    • /
    • 2008
  • Condition monitoring technologies allow achieving this goal by minimizing downtime through the integrated planning and scheduling of repairs indicated by condition monitoring techniques. Thermal runaways induced by conduction problems deteriorate insulating material and cause disruptive dielectric discharges resulting in arcing faults. Therefore, having the ability to directly measure the temperature of the contacts while in service will provide more information to determine the true condition of the equipment. It allows connective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on -line condition monitoring of energized equipment is applicable both as stand alone system and with an interface for power quality monitoring system. The paper presents the results of wireless temperature monitoring: of electrical equipment at a power plant.

드론산업 인프라 투자 우선순위에 관한 연구 (A Study on the Priority of Drone Industry Infrastructure Investment)

  • 심명식;이상준;송동엽
    • 스마트미디어저널
    • /
    • 제9권3호
    • /
    • pp.130-141
    • /
    • 2020
  • 국내는 방제·방역, 탐사·측량, 수색·구조, 영상촬영, 시설관리 등 드론활용 시장 중심으로 성장 추세이나 드론의 핵심기술·부품에 대한 외산 의존도는 높은 실정이다. 미국, 중국 등 드론 선진국들은 드론의 무기화를 확대하고 있으며, 이에 따라 향후에는 드론산업 관련 수·출입 규제 강화, 독과점 등 국가 간 무역 전쟁이 더욱 강화될 우려가 있다. 따라서 차세대 드론의 핵심 기술과 부품·부속장비 등에 대한 연구개발 및 국산화를 위한 정책적 연구와 인프라 투자가 선행 되어야 할 필요가 있다. 본 연구에서는 AHP 기법을 활용하여 소형 드론기업 육성을 위한 인프라 투자 우선순위를 선정하고, 인프라 투자 전략을 제시하였다.

FPD 장비 습식공정에서의 안전한 히터 공급 계통도 및 제어 회로 (Safety Schematic Diagram and Sequence of Heater in FPD Wet Equipment)

  • 유흥렬;손영득
    • 전기전자학회논문지
    • /
    • 제23권1호
    • /
    • pp.107-111
    • /
    • 2019
  • FPD(Flat Panel Display) WET(습식) 장비의 히터 사용은 필수로 사용된다. 히터 사용에 따른 단선과 과열로 인한 전기사고가 다발하여 안전적인 전기 계통도 및 인터락이 필요하다. 따라서 본 논문에서는 FPD WET장비에 들어가는 전기 계통도 및 인터락을 제안하였다. 레벨센서, 과열방지기, SSR heater sink와 같은 하드웨어 인터락을 넣었으며, 전기 계통도로써는 ELB-MC-SSR-EOCR-Heater로 구성되어 있다. 인터락 발생시 마그네틱 컨텍터(MC)가 오프되어 Heater의 전원을 차단하는 방식이다. 전기적 과전류 보호장치인 EOCR 과전류, 부족전류, 단선 체크를 하면서 히터에 이상 있을 시 MC를 차단하는 인터락이 구성되어 있다. 이러한 회로 구성 및 인터락은 WET 장비 뿐만 아니라 히터가 들어가는 어떠한 장비에도 유용할 것으로 보인다.

AHP 분석을 이용한 기계식 주차설비 건설 중 위험성 평가방안 연구 (Risk Assessment of Mechanical Parking Facility during Construction based on AHP Analysis)

  • 이정한;김용곤;이재원;김종훈
    • 한국안전학회지
    • /
    • 제37권5호
    • /
    • pp.33-41
    • /
    • 2022
  • As the number of automobile registrations increases yearly, parking spaces that are located in downtown areas are increasing, and mechanical parking facilities are also increasing. Therefore, there is a high risk of accidents when installing and repairing a mechanical parking facility. In the preceding six years (from 2012 to 2018), the statistics that pertain to accidental disasters indicated that a total of 137 disaster victims were generated by the construction sector, 33 accidents occurred, and 10 people died. However, only the safety management items pertaining to accidents that occur during maintenance work and the use of the installed mechanical parking facilities are being studied; furthermore, there is no ongoing research with respect to the risk management that is conducted at the construction site. In 2017, the Korea Occupational Safety and Health Agency (KOSHA) announced the "Guidelines for Safe Installation and Maintenance of Mechanical Parking Equipment"; however, it is a safety guideline that is limited to the installation of basic protective equipment and to facility installation. There is no model for mechanical parking facilities that is indicated in the "Risk Assessment Model by Construction Industry Type", which is issued by the Safety and Health Corporation and is widely utilized for risk assessment in the construction industry; moreover, elevator installation work CODE N0: 22 is the only major example of a disaster. In this study, "risk assessment through a focus group interview" was performed, and data was derived from the "risk assessment of Article 41 (2) of the Industrial Safety and Health Act", which reflects the characteristics of the construction industry based on AHP analysis. The results of this study can be utilized for the risk assessment that is conducted during the construction stage of mechanical parking facilities.

선박 ICT융합 장비 기능시험 시설 구축 연구 : 선박 디지털 인터페이스 및 주요 항해통신장비를 중심으로 (An Establishment of Functional Test Facility for ICT-Convergence Equipment of Vessel : Focused on Maritime Digital Interfaces and Main Navigation Communication Systems)

  • 황훈규;김배성;우상민;우윤태;신일식
    • 한국정보통신학회논문지
    • /
    • 제22권5호
    • /
    • pp.754-763
    • /
    • 2018
  • 선박 ICT융합 장비를 개발하여 선박에 탑재하기 위해서는 형식승인이 필수적으로 이루어져야 하며, 이를 위해서는 환경시험과 기능시험이 요구된다. 환경시험은 대상 장비가 선박 및 해상환경에서 동작하기 위해 요구되는 내구성을 만족하는지 시험하는 것을 의미하며, 기능시험은 대상 장비가 국제표준을 준수하여 고유 기능을 정확하게 수행하는지 시험하는 것을 의미한다. 국내 선박 ICT융합 장비에 대한 환경시험 가능 기관은 227여 곳에 달하는 반면, 기능시험 가능 기관은 전무한 실정이다. 이러한 이유로 현재 선박 ICT융합 장비 기능시험 시설을 구축 중에 있으며, 본 논문에서는 우선적으로 추진 중인 선박 디지털 인터페이스 및 항해통신장비의 기능시험 체계의 개발에 관한 내용을 다룬다. 주요 내용은 대상 장비의 기능시험을 단일 테스트 및 통합 테스트의 두 단계로 수행함으로써 시험 결과의 신뢰성을 향상시키는 것으로, 단일 테스트는 대상 장비의 고유 기능이 정상적으로 동작하는지를 확인하는 것이고, 통합 테스트는 정상적으로 다른 항해통신장비와 조화롭게 동작하는지를 검증하는 것이다. 이를 위해 단일 테스트에 요구되는 부가 연동 장비 등의 필수 기능 요소와 통합 테스트에 요구되는 연계 및 확장 요소를 분석한다.

석탄광 산성항내배수의 중화 처리시설 설계에 관한 연구 (A Study on a Neutralization Treatment Facility Design of an Acid Mine Drainage for Colliery)

  • 이춘택
    • 기술사
    • /
    • 제18권1호
    • /
    • pp.1-17
    • /
    • 1985
  • This report is prepared to assist designers acid mine drainage treatment plants. Example of a treatment facility design is included, delineating general equipment specification and cost breakdowns. The purpose of this outline is to give the designer insight into tile evaluation of possible alternative and justification for choosing a certain method or process and also this report will allow designers to derive and estimated budget number for capital expenditures.

  • PDF

배전용 변압기 단락강도 시험설비 개발 (Development of Short-circuit Testing Facility for Distribution Transformers)

  • 박지훈;민윤홍;강영학;유호근;안규선;함길호;오창주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.64-67
    • /
    • 2002
  • To increase the short-circuit testing capacity of distribution transformers, testing facility has been installed for KEPCO in Vi-wang. The power supply of testing facility is directly supplied from the network substation located closely. Testing can be performed up to 300 kVA for single-phase transformers, 500 kVA for three-phase transformers. Operating with this facility, the distribution company is able to maintain the reliable supply of electricity. Also the critical quality of transformers from manufacturers can be verified by short-circuit testing. This paper describes the design concept and specification of newly developed equipment and the procedure of short-circuit test.

  • PDF