A Study on Improvement of Safety Management of Low Voltage Electrical Equiment (일반용 저압전기설비의 안전등급제 도입에 관한 연구)

  • Jae-Phil Han;Yong-Sung Choi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.6
    • /
    • pp.598-602
    • /
    • 2023
  • With the purpose of instilling an awareness of the safety of users of electrical equipment and inducing voluntary facility improvement through the safety rating system for general low voltage electrical equipment, simulation and field application of the safety rating of general low voltage electrical equipment were conducted. For the introduction and application of the safety rating system for general low-voltage electrical equipment, data related to domestic safety was investigated and analyzed, cases of introduction in other fields were reviewed, and for design, the 4M risk assessment method of the Korea Occupational Safety and Health Agency and the cases of safety index development in Korea were analyzed and standardized. Safety rating system simulations were conducted for general low-voltage electrical equipment, and problem improvement measures were prepared by analyzing the results through on-site verification and simulation applied to the initial design. Design standards for the introduction of the safety rating system for general low-voltage electrical equipment were prepared, and 394 youth training facilities were applied to the field to see if the design standards were practically applicable to the field. With the application of the safety rating system for low-voltage electrical equipment for general use, youth training facilities that had been classified as 'appropriate' were able to induce an upgrade to a higher level through voluntary facility improvement according to the application of grades (A to E). As a result of inducing voluntary repair projects based on the results of the 1st and 2nd inspection of youth training facilities, it was confirmed that 86 facilities received grade A, 225 facilities received grade B, and only 311 facilities received grade A to B out of a total of 394 facilities, and there was no grade E.

A Management Plan of the Resources for Emergency Medical Facility at Disaster Site (재난현장 응급의료 시설자원 관리방안)

  • Song, Youngsub;Suh, Sangwook;Yoon, Yousang
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.3
    • /
    • pp.46-53
    • /
    • 2019
  • Recently, the need for emergency medical facilities is increasing due to a large-scale disaster. The Ministry of the Interior and Safety has completed the development of Disaster Resource Sharing System (DRSS). In this system, only air tent and negative pressure tent, which are classified and managed as equipment are resources related to emergency medical facility at disaster site. However, the characteristics of resources for the facility such as the time of input, a period of stay, transportation, and installation methods were not reflected. So, The purpose of this study is to propose improvements of management of resources for emergency medical facility at disaster site, that classified to materials and equipment in DRSS. This study analyzed the state of resources for facilities and the attributes of resources based on literature and disaster medical consultation of mobile hospitals. The resources for emergency medical facility are required to be linked to medical support resources and reflected in the DRSS, since emergency medical facility resources at the disaster site should be managed through a combination of medical resources classified as equipment. And future research on installation of emergency medical facilities plan considering the cost of the disaster management resources should be carried out.

A Study on The Improvement of Weapon System Test and Evaluation - Focusing on the weapon system in the research development stage - (연구개발무기체계 시험평가 발전방안에 관한 연구)

  • Lee, Kang-Un;Boo, Joon-Hyo
    • Journal of National Security and Military Science
    • /
    • s.8
    • /
    • pp.383-420
    • /
    • 2010
  • This article is focusing on the improvement of weapon system test & evaluation, aimed at the weapon system in the research development stage. This article suggests improvement directions in three aspects(organization and system, skilled manpower and technology, test facilities of weapon system test & evaluation) as follows. 1) Weapon system test & evaluation organization and system a. Establishment of comprehensive test & evaluation system b. Making regulation for comprehensive test infrastructure management. c. Standardization of test & evaluation process, which can be used in special subject to army, navy and air force. 2) Skilled manpower and technology of weapon system test & evaluation a. Training & education, management of test & evaluation experts. b. Establishment of skill management system of test & evaluation. 3) Test facilities of weapon system test & evaluation a. Establishment of comprehensive improvement direction of test & evaluation installation and equipment. b. Consideration of counter measures to prevent overlapping investment, and to use the test & evaluation resources efficiently. c. Establishment of organic network for the effective use of test & evaluation installation and equipment. d. Establishment of detailed cooperation plan for the commonage of test & evaluation facility and equipment.

  • PDF

Design of Standard Facility Interface for Efficient Building Control (효율적인 빌딩 관제를 위한 표준설비 인터페이스 설계)

  • Moon, Sang-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.2
    • /
    • pp.334-337
    • /
    • 2021
  • Recently, the necessity of rapid response to social problems such as disasters and quarantine arising from the complex and diverse social structures has emerged. As the number of large buildings increases, large-scale human damage is expected in the event of a disaster such as fire. To solve this problem, efficient control must be achieved through interfacing with various equipment and facilities installed inside the building. In this paper, we intend to study the interface method for various facilities in the building for efficient control. In detail, the facility standard model is defined by examining the status and specification of building. In addition, we intend to design and propose a standard facility communication data frame to support the protocol applicable to this model.

Developement of a Design Manual for Kitchen Facility in Foodservice Outlets: A Case Study on a Seolleongtang Specialized Restaurant (푸드서비스시설의 주방 설비 산정 매뉴얼 개발: 설렁탕 전문 식당 사례 적용)

  • Choi, Gyeong-Gy;Chang, Hye-Ja
    • Journal of the FoodService Safety
    • /
    • v.2 no.2
    • /
    • pp.67-77
    • /
    • 2021
  • Concerns regarding work and food safety in foodservice operations are growing. The purpose of the study is to suggest guidelines for designing foodservice facilities, including school foodservices and Korean restaurants. A case of a franchise restaurant specializing in a Korean food item, Seolleongtang, was used to explain the facility design. The contents of the manual included ways to determine space allocation, calculate the application of utilities and the diameters of supply utility pipelines, and suggestions on how to decide on air conditioning equipment. The standards of the American Gas Association and the Japan Foodservice Equipment Association (JFEA) were applied to design the restaurant space. The JFEA standards and knowledge based on experience and statistics were applied to calculate the usage of utilities like fuel and water. The standards of JFEA and the Society of Heating, Air-Conditioning, and Sanitary Engineers of Japan were applied to calculate the diameters of the water supply and drainage pipelines. For the setting of the heating, ventilation, and air conditioning systems, three ways to carry out the calculation of effective ventilation were explained, as well as options to dicide the standard parameters of the duct and ventilation fans. This manual can contribute to the design of effective and efficient foodservice facilities and help secure the work safety of foodservice employees thereby ensuring food safety.

Facility scheduling problem in Grain terminal for reducing demurrage rate (양곡부두의 체선율 감소를 위한 부두 장비 및 사일로 스케줄링 연구)

  • Shin, Jae Young;Park, Jongwon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.06a
    • /
    • pp.60-61
    • /
    • 2013
  • One of the most important indicators for measuring service level and productivity of the port may be a demurrage rate. Currently, in the case of grain terminal of Busan North Port, demurrage rate are recognized at a very high level, in order to improve this, it is tilted more effort operational. In order to reduce the demurrage, there is a way expansion of facility of hardware, such as the replacement of aging equipment, and how manipulative assignment rules of the apparatus of the operation on the software side, such as changing the order of facility allocation. If the financial reasons are out of question, it is possible to expand to reduce the demurrage rate by operational way. Therefore this paper deals with how to operate some of the allocation rules and silo allocation rules of equipment to reduce the work hours with model and how to operate basic equipment and grain terminal of Busan North Port want to be seen by comparative analysis.

  • PDF

Improving Physical Therapy Services of Health Centers in Korea (전국 보건소 물리치료실 운영 실태와 활성화 방안)

  • Chang, Eun-Ju
    • Journal of Korean Physical Therapy Science
    • /
    • v.3 no.2
    • /
    • pp.1021-1036
    • /
    • 1996
  • The purpose of this study are ( i ) to examine operating situation of physical therapy department and job satisfaction of physical therapists in health centers, (ii) to analyze utilization patterns and patient satisfaction of physical therapy services among health center visitors, and finally, (iii) to suggest policy implications in facilitating improvement on physical therapy services of health centers. The materials are collected from 105 physical therapists among nationwide health centers and 203 patients of 5 health centers in Pusan, Korea. The survey is conducted from February 13 to March 30, 1996 with a structured self - administered questionnaire. Major results of the study are as follows. First, the result of regression analysis between job satisfaction and affecting factors identify following variables as the significant determinants; self-development(+), job itself(+), and co-worker support (+). Second, the current operating situation of physical therapy department shows such problem as; i )shortage and unstable job security of physical therapists, ii )absence of rehabilitation specialist, iii )lack of understanding on physical therapy of co-workers, iv)shortage of physical therapy equipment and facility, v)burdensome task of physical therapists, and vi) inappropriate purchase process of equipment. Third, patient satisfaction for physical therapy services are revealed relatively high. And the result of regression analysis between patient satisfaction and affecting factors identify following variables as the significant determinants; credibility of physical therapist(+), satisfaction for waiting time(+), cleanliness(+). Fourth, the patients appeal about physical therapy services such problem as; i) shortage of physical therapists, physical therapy equipment, and facility, ii) inconvenient administrative procedure for utilization physical therapy services. Fifth and last, recommendations for the improvement of physical therapy services of health centers are as follows; i )recruiting more physical therapists, ii )regular employment of physical therapists instead of daily use employment, iii )re-arrangement of facility for patient's convenience, iv )establishing reasonable purchasing system of equipment for physical therapy, v) reforming administrative procedure for patient focused care.

  • PDF

Analysing the Effect of Residual Chlorine Equalization for Water Quality Improvement in Water Distribution System (공급과정 수질개선을 위한 잔류염소 균등화 효과분석)

  • Choi, Taeho;Lee, Doojin;Bae, Cheolho;Moon, Jiyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.5
    • /
    • pp.587-596
    • /
    • 2016
  • This study attempts to draw factors for an analysis of the operation effect of a rechlorination facility and autodrain equipment for residual chlorine equalization by installing and operating a rechlorination facility and autodrain equipment in P City and analyzing the practical evaluation method and operation effect. For this purpose, this study selected three indicators for an analysis of the effectiveness of residual chlorine equalization and conducted a comparative analysis before and after the implementation of the residual chlorine equalization. As a result of estimation, (1) the reduction of the residual chlorine concentration range from a water treatment plant to the pipe end was 16.0%; (2) the total reduction of chlorination input was 18.0%; and (3) the reduction of the generation of disinfection by-products was 19.5%. In addition, this achieved enough residual chlorine equalization in the supply process and shows that it could successfully achieve the economic feasibility of investment in equipment and the reduction of the generation of disinfection by-products. Like this, it is judged that the three indicators suggested in this study will be used sufficiently as indicators of an analysis of the effectiveness of residual chlorine equalization according to the operations of the rechlorination facility and autodrain equipment.

Research on management plan of Defense Facilities and Equipments through DRES (국방연구시설장비 정보시스템(DRES)을 통한 국방연구시설·장비 관리 방안 연구)

  • Kim, Jin-sik
    • Journal of Internet Computing and Services
    • /
    • v.19 no.3
    • /
    • pp.79-88
    • /
    • 2018
  • Major countries stay to expand invest in R&D to promote new growth engines in the future and to secure new technologies and Korea is also expanding to R&D investment. Quality of R&D investment is getting more Important than quantity of R&D investment because Korea's indicator related to R&D investment is already world class with other countries's investment scale by comparison with GDP. According to this trend, Korea's policy in R&D is focusing the R&D Innovation Plan and "Utilization of R&D Facility and Equipment(F&E)" has been getting important. In this research, it research on facility and equipment management plan through Defense R&D Equipment information System(DRES). It analyzes existing process F&E in Defense field and Nation. Furthermore, it explains major process, function, and menu reflecting Defense F&E management rule enacted recently. Lastly, it shows the development direction for Defense F&E management.

An intelligent consultant for material handling euqipment selection and evaluation

  • Park, Yang-Byung;Cha, Kyung-Cheon
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1995.04a
    • /
    • pp.79-90
    • /
    • 1995
  • The material handling equipment selection, that is a key task in the material handling system design, is a complex, difficult task, and requires a massive technical knowledge and systematic analysis. It is invaluable to justify the selected equipment model by the performance evaluation before its actual implementation. This paper presents an intelligent knowledge-based expert system called "IMESE" created by authors, for the selection and evaluation of material handling equipment model suitable for movement and storage of materials in a manufacturing facility. The IMESE is consisted of four modules: a knowledge base to select an appropriate equipment type, a multiple criteria decision making procedure to choose the most favorable commercial model of the selected equipment type, a database to store the list of commercial models of equipment types with their specifications, and simulators to evaluate the performance of the equipment model. The whole process of IMESE is executed under VP-Expert expert system environment.vironment.

  • PDF