• Title/Summary/Keyword: Facility Safety

Search Result 1,941, Processing Time 0.031 seconds

A Study on the Development of the Measuring Scale of Safety Consciousness (안전의식 측정 척도 개발 연구 : 서울시 일부 중학생을 중심으로)

  • 김혜원;이명선
    • Korean Journal of Health Education and Promotion
    • /
    • v.19 no.1
    • /
    • pp.87-107
    • /
    • 2002
  • Recently, the industrialized world is suffering from accidents referring from the lack of safety consciousness. According to Korean Safety Regulation Department(1996), students at junior high schools are mostly involved in safety accidents, and this is due to lack of safety consciousness. To prevent these accidents, we need to have safety consciousness and attitude. To make junior high school students who are mostly affected in these accidents act safely, they need to know their level of safety consciousness. The purpose of this study is to develop a guideline of measuring the scale of safety consciousness and analyze the relationship between safety education, accident experiences and safety consciousness. This study is based on a survey of 708 junior high students in Seoul, which was carried out from 12 November, 2001 to 21 November, 2001. 1. The main fields of safety consciousness are home safety, school safety, fire safety, emergency management based on documents. Home safety is again divided into facility safety and livelihood safety, school safety is divided into facility safety, livelihood safety and laboratory safety, traffic safety is divided into pedestrian safety, bicycling safety and public transportation safety, fire safety divided into prevention and escaping during fire breakouts, emergency management safety is divided into general principles and escaping during emergency situations. 2. The primary safety consciousness scale was made according to every field of safety consciousness. A preliminary examination based on the scale and a study of reliance and the factors was held. Based on these results, 27 questions which were concerned to be impairing reliability or lacking in factor were deleted on the secondary safety consciousness scale development The secondary safety consciousness scale which constituted of 73 questions was put into another preliminary study and after analyzing reliability and the factors, 12 questions of low reliabilities were deleted and with these results, the third scale were made consisting of 61 questions. 3. A study based on the third safety scale which is made of 61 questions, were held and with a analysis of the reliability and factors made, the relationship between safety education, accident experience and safety mind were examined. (1) The study of reliability and factors show that Cronbach's coefficient in home safety fields is .7598, in school safety .7924, in traffic safety .8306, in emergency treatment .7775, in fire safety .7247. The questions indicating low reliability were deleted. The factor analysis revealed that home safety is converged on facility safety and livelihood safety. But one question was deleted because it showed incongruence of validity. School safety was converged on facility safety, livelihood safety and laboratory safety. But 2 questions showed incongruence of validity and these were deleted. Traffic safety fields were converged on pedestrian safety, bicycle safety and public transportation safety. One question showing incongruence of validity was deleted. Emergency treatment fields converged on general principles and acting in emergency situations and three questions showing incongruence of validity were deleted. Fire safety was converged on prevention and acting in fire breakouts. Totally, eight questions were removed and the final scale were consisted of 53 questions (2) The 3/sup rd/ grade students scored higher average safety mind scales than 1st graders(p〈.05). And students who had high scores at school tend to have a higher scale than those who do not(p〈.001). (3) Average scale of students who had experience in safety education were higher(p〈.001). Students who had previously been involved in home safety accidents had a low score(p〈.001). This was same to students with experience in school safety accidents(p〈.001). Students with traffic safety accidents and fire safety accidents tend to have a lower scale too(p〈.05, p〈.001).

Indicator of Facility Performance Evaluation (FPE) for Educational Facilities of BTL Projects

  • Lee, Kwan-Jong;Lee, Chun-Kyong;Park, Tae-Keun
    • Architectural research
    • /
    • v.14 no.1
    • /
    • pp.35-44
    • /
    • 2012
  • Build-Transfer-Lease (BTL) was introduced to the domestic construction market in 2005. Now, seven years later, the BTL model is most active for educational facilities. In 2011, 93 educational facility projects entered the maintenance stage. Considering the characteristics of today's BTL projects for educational facilities, the main issues are the initial performance and maintenance of educational facilities and the service-providing status for the 20-year operational management period, in relation to providing safety and convenience to students, the facility users. Seeking a solution, local education offices and departments in charge of BTL under the Ministry of Education, Science, and Technology have been exploring various methods of evaluating operational maintenance performance from various perspectives. For educational facility BTL projects, however, the appropriateness of initial operation performance evaluation, rather than considering the 20-year operational management period, is controversial in regards to sustainability. On this account, performance evaluation items in four areas-operational maintenance evaluation, facility performance status evaluation, maintenance subject evaluation, and sustainable change response evaluation-should be extracted. An indicator of facility performance evaluation is presented in this study through an AHP survey targeting experts, as part of establishing an operation performance evaluation system for educational facility BTL projects.

TECHNICAL REVIEW ON THE LOCALIZED DIGITAL INSTRUMENTATION AND CONTROL SYSTEMS

  • Kwon, Kee-Choon;Lee, Myeong-Soo
    • Nuclear Engineering and Technology
    • /
    • v.41 no.4
    • /
    • pp.447-454
    • /
    • 2009
  • This paper is a technical review of the research and development results of the Korea Nuclear Instrumentation and Control System (KNICS) project and Nu-Tech 2012 program. In these projects man-machine interface system architecture, two digital platforms, and several control and protection systems were developed. One platform is a Programmable Logic Controller (PLC) for a digital safety system and another platform is a Distributed Control System (DCS) for a non-safety control system. With the safety-grade platform PLC, a reactor protection system, an engineered safety feature-component control system, and reactor core protection system were developed. A power control system was developed based on the DCS. A logic alarm cause tracking system was developed as a man-machine interface for APR1400. Also, Integrated Performance Validation Facility (IPVF) was developed for the evaluation of the function and performance of developed I&C systems. The safety-grade platform PLC and the digital safety system obtained approval for the topical report from the Korean regulatory body in February of 2009. A utility and vendor company will determine the suitability of the KNICS and Nu- Tech 2012 products to apply them to the planned nuclear power plants.

Study on the Status of Fire Safety Management in Elderly Welfare Facilities (노인복지시설의 소방안전관리실태에 관한 연구)

  • Ko, Wang-Youl;Hur, Man-Sung
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.108-115
    • /
    • 2018
  • Elderly welfare facilities are extremely susceptible to mass casualties in disastrous situations, such as fire, due to the limited physical and mental abilities of their residents. This study examined the status of fire safety management, including the structural problems of elderly welfare facilities, problems of the installation and management of firefighting systems, and problems regarding of fire safety managers. After the Sejong Medical Welfare Facility fire, these problems have been complemented by retrofitting firefighting systems in accordance with the revision of the relevant laws and regulations. On the other hand, the overall status of fire safety management is still insufficient. Therefore, it is important to improve the stability of buildings and firefighting systems as well as fire safety management through additional revision of the relevant laws and regulations.

A Study of driving simulator applications for road safety in geometric design (도로선형과 기하구조 연구를 위한 드라이빙 시뮬레이터의 교통안전시설 요소분석)

  • Chung, Sung-Hak
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2008.11a
    • /
    • pp.561-567
    • /
    • 2008
  • The objectives of this study is to: (1) develop how applications for driving simulator of national highway safety designs when those are appeared; (2) examine the degree to which those geometric designs of the horizontal and vertical profile; and (3) search positive safety and passive highway safety design of the point at which highway alignment factors initiate driving safety to facility or highway design.

  • PDF

A Study on the Field Management System for Traffic Safety Facilities in IoT Infrastructure (IoT 기반 교통안전시설 현장관리 체계 연구)

  • WON, Sang-Yeon;LEE, Jun-Hyuk;JEON, Young-Jae;KIM, Jin-Tae
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.25 no.1
    • /
    • pp.1-15
    • /
    • 2022
  • In order to trust and use autonomous vehicles, safe driving on the road must be guaranteed. For this, the first infrastructure to be equipped with autonomous driving is traffic safety facility. On the other hand, autonomous vehicles(Level 3) and general vehicles are driving on the road, it is necessary to additionally manage existing general traffic safety facilities. In this study, a field management system for traffic safety facilities based on autonomous driving infrastructure was studied, and a pilot field management system was implemented in the demonstration area(Pangyo). The pilot system consists of a GNSS(Global Navigation Satellite System) receiver, a field management equipment, and a field management app. As a result of field demonstration,, it was confirmed that traffic safety facility information was easily transmitted and received even in downtown areas and that could be efficiently operated and managed. It is expected that the results of this study will be used as reference materials for the spread of autonomous driving infrastructure to local governments and infrastructure construction in the future.

A Study on the Safety Improvement of City Gas Pressure Regulators in Apartment Housing (공동주택 등에 설치하는 도시가스 압력조정기의 안전성 향상에 관한 연구)

  • Youngman Yun;Yongchai Kwon;Kyungho Kim;Jihyun Jang
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.2
    • /
    • pp.86-94
    • /
    • 2023
  • This study was conducted with the purpose of preparing an alternative to improving the safety of civil pressure regulators installed instead of gas governors to supply city gas to apartment houses. First, problems were derived and solutions were presented by investigating the safety standards and installation status of domestic pressure regulators. In addition, using the DNV Phast-Safeti program, a quantitative risk assessment solution, risks such as gas leakage contained in pressure regulators installed in apartment houses and surrounding gas facilities were evaluated in terms of individual risks and societal risks, and measures were derived to reduce the risks in the installation and management of the pressure regulators.

Study on the Improvement Plans of Condensation Defect Examples in Apartment Building (공동주택 결로 하자 사례를 통한 개선방안 도출)

  • Oh, Se Min;Park, Sun Hyo;Joung, Kwang Sub
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.82-88
    • /
    • 2017
  • There are main issues of defect type that condensation, concrete crack and noise in apartment buildings. Especially, according to the Apartment Defect Dispute Mediation Committee in Korea (ADDMC) at Ministry of Land Infrastructure and Transport in Korea (MLIT), condensation defects are great importance (14 percent) on whole number of reported cases of faults from 2015 in Korea. Most condensation defects have many different causes that take a toll on the resident's life and space. So it is very important to early detection and repair. For preventing the condensation in apartment buildings, there are building codes in Korea such as 'Standard of Method and Judgment for Apartment defect of investigation, Repair cost Estimate'. This research aims to study on the improvement of preventing the condensation aforementioned korea standard. Types and characteristics (opaque wall, windows, doors) of cause of occurrence and existing state condensation defect is analyzed from evaluation of real application 100 case in 2015 ADDMC data.

Path planning in nuclear facility decommissioning: Research status, challenges, and opportunities

  • Adibeli, Justina Onyinyechukwu;Liu, Yong-kuo;Ayodeji, Abiodun;Awodi, Ngbede Junior
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3505-3516
    • /
    • 2021
  • During nuclear facility decommissioning, workers are continuously exposed to high-level radiation. Hence, adequate path planning is critical to protect workers from unnecessary radiation exposure. This work discusses recent development in radioactive path planning and the algorithms recommended for the task. Specifically, we review the conventional methods for nuclear decommissioning path planning, analyze the techniques utilized in developing algorithms, and enumerate the decision factors that should be considered to optimize path planning algorithms. As a major contribution, we present the quantitative performance comparison of different algorithms utilized in solving path planning problems in nuclear decommissioning and highlight their merits and drawbacks. Also, we discuss techniques and critical consideration necessary for efficient application of robots and robotic path planning algorithms in nuclear facility decommissioning. Moreover, we analyze the influence of obstacles and the environmental/radioactive source dynamics on algorithms' efficiency. Finally, we recommend future research focus and highlight critical improvements required for the existing approaches towards a safer and cost-effective nuclear-decommissioning project.

A Study on the Establishment of Facility Guidelines for Infectious Diseases Hospitals - Focusing on Operational Methods and Architectural Planning (감염병전문병원의 시설 가이드라인에 관한 연구 - 운영방식과 건축계획을 중심으로)

  • Choi, Kwangseok
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.2
    • /
    • pp.17-29
    • /
    • 2022
  • Purpose: In terms of efficiency and safety, this study attempted to organize data on the operation methods and architectural planning of infectious diseases hospitals. Methods: The results obtained through on-site and interview surveys with hospital officials and medical staffs at four infectious diseases hospitals under construction were summarized based on those original business plans and facility guidelines. Results: First, the operational methods to secure safety and operational efficiency were summarized for each department which are major hospital functions of infectious disease hospitals. Second, as the architectural planning, the characteristics of space and circulation of each department are summarized. For safety of medical staff, negative pressure and non-negative pressure zone have to completely separated. In addition medical staff wears PPE and enters the negative pressure zone and returns in the order of admiral, shower, and gowning in the PPE undressing room after patient treatment. In case of operational efficiency, flexible operation is required in normal and crisis situations. For example, it is important for The Ward to gradually switch to negative pressure beds in times of crisis from normal situation and the outpatient department considers the composition of negative pressure and non-negative pressure outpatient spaces that can operate in parallel even in crisis situations. Implications: Infectious disease hospitals require flexible operation and appropriate facilities for normal and crisis situations.