• Title/Summary/Keyword: Facility Safety

Search Result 1,956, Processing Time 0.038 seconds

A Study on the Nature-friendly Management Regarding the User Pattern of Yangjae Stream (양재천의 이용특성을 고려한 환경친화적 관리방안에 관한 연구)

  • Kim Sun-Hee;Hong Suk-Hwan;Bae Jung-Nam
    • Korean Journal of Environment and Ecology
    • /
    • v.18 no.3
    • /
    • pp.306-315
    • /
    • 2004
  • Yangjae stream, stretching through Seocho-gu and Gangnam-gu, is a representative city stream with its environmentally friendly stream makeover project model, launched in 1995. The district of Gangnam-gu, the subject of this study, is under high pressure from the residents for its use as a huge residential areas close to the stream. The study has two main purposes. The first is to identify the condition and characteristic of utilization of Yangjae stream which is currently being increased in use by the stream restoration. Secondly, the study aims to suggest the environment-friendly management to accomplish arrangement of the naturally friendly stream based on the identification survey, The result from the user survey with 303 valid answer sheets show that the people from neighboring residential areas use this stream a lot doing exercising(51.8%) and taking a walk(24.4%) in their free time. Also regular use rate is high, and people are likely to use it alone(30.4%) or as a family(28.4%). With regard to the need of facility increase, even though the respondents required resting places in the shade(80.8%) most, overall, additional introduction of facilities was analyzed as unnecessary(78.8%). safety issue(22.0%) and a lack of convenience facilities(17.6%) and resting places in the shade(16.6%) are pointed as main problems while the users are generally satisfied(59.5%) with the stream. Improving walk-way and planting trees for shade on the slope were designed as a solution for these problems. For securing safety through improvement of walk-way, the scattering of pressure of current walk with building new walk using berms was presented. In order to increase safety on the walk-way(see above figure), the study proposes to build a new walk-way with berms to disperse excessive pressure. It also suggests the tree planting to provide shade in the stream and to make a provision for the planting of forest trees in the current law.

Analysis of the Level of Microbial Contamination in the Manufacturing Company of Ginseng Products (인삼류(홍삼, 백삼) 제조·가공업체의 미생물 오염도 조사)

  • Shim, Won-Bo;Lee, Chae-Won;Choi, Young-Dong;Park, Sang-Gon;Jeong, Myeong-Jin;Kim, Jeong-Sook;Kim, Se-ri;Park, Ki-Hwan;Chung, Duck-Hwa
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.2
    • /
    • pp.159-165
    • /
    • 2015
  • The aim of this study was to investigate microbiological contamination levels in the manufacturing company of ginseng products (white and red ginseng). Firstly, the contamination level for ginseng and each stage ginseng were 1.8~4.9 log CFU/g (total bacteria), 1.2~3.0 log CFU/g (coliform), 0.8~4.1 log CFU/g (fungi). However, only Bacillus cereus among pathogenic bacteria was detected from a few sample. The contamination of total bacteria tended to decrease as ginseng was being processing. Therefore, that of finished products (white and red ginseng) showed the lowest contamination level among each stage ginseng sample. That of fungi decreased steadily, although the contamination of fungi has tended to increase right after ginseng was steamed. Secondly, the contamination level for working tools and facilities were $1.7{\sim}4.7log\;CFU/cm^2$ (total bacteria), $0.4{\sim}4.0log\;CFU/cm^2$ (coliform), $0.9{\sim}4.2log\;CFU/cm^2$ (fungi). Especially, washing and peeling machines were higher contamination level. Finally, the contamination level of worker who washed and steamed ginseng was higher than worker who shaped, sorted and stored ginseng. Also, Staphylococus aureus was detected at 0.2~0.7 log CFU/hand on some wokers' hands. These results showed proper heating condition (temperature and time) and tidy manufacturing facility are the most important to avoid developing any microbiological problem of Ginseng Products.

A Study on the Dose Assessment Methodology Using the Probabilistic Characteristics of TL Element Response (확률분포 특성을 이용한 열형광선량계의 선량평가방법에 관한 연구)

  • Cho, Dae-Hyung;Oh, Jang-Jin;Han, Seung-Jae;Na, Seong-Ho;Hwang, Won-Guk;Lee, Won-Keun
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.123-138
    • /
    • 1998
  • Characteristics of element responses of Panasonic UD802 personnel dosimeters in the X, ${\beta}$, ${\gamma}$, ${\gamma}/X$, ${\gamma}/{\beta}$ and ${\gamma}$/neutron mixed fields were assessed. A dose-response algorithm has been developed to decide the high probability of a radiation type and energy by using the distribution in all six ratios of the multi-element TLD. To calculate the 4-element response factors and ratios between the elements of the Panasonic TLDs in the X, $\beta$, and $\gamma$ radiation fields, Panasonic’s UD802 TLDs were irradiated with KINS’s reference irradiation facility. In the photon radiation field, this study confirms that element-3 (E3) and element-4 (E4) of the Panasonic TLDs show energy dependent both in low- and intermediate-energy range, while element-1 (E1) and element-2 (E2) show little energy dependency in the entire whole range. The algorithm, which was developed in this study, was applied to the Panasonic personnel dosimetry system with UD716AGL reader and UD802 TLDs. Performance tests of the algorithm developed was conducted according to the standards and criteria recommended in the ANSI N13.11. The sum of biases and standard deviations was less than 0.232. The values of biases and standard deviations are distributed within a triangle of a lateral value of 0.3 in the ordinate and abscissa, With the above algorithm, Panasonic TLDs satisfactorily perform optimum dose assessment even under an abnormal response of the TLD elements to the energy imparted. This algorithm can be applied to a more rigorous dose assessment by distinguishing an unexpected dose from the planned dose for the most practical purposes, and is useful in conducting an effective personnel dose control program.

  • PDF

Development and assessment of pre-release discharge technology for response to flood on deteriorated reservoirs dealing with abnormal weather events (이상기후대비 노후저수지 홍수 대응을 위한 사전방류 기술개발 및 평가)

  • Moon, Soojin;Jeong, Changsam;Choi, Byounghan;Kim, Seungwook;Jang, Daewon
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.11
    • /
    • pp.775-784
    • /
    • 2023
  • With the increasing trend of extreme rainfall that exceeds the design frequency of man-made structures due to extreme weather, it is necessary to review the safety of agricultural reservoirs designed in the past. However, there are no local government-managed reservoirs (13,685) that can be discharged in an emergency, except for reservoirs over a certain size under the jurisdiction of the Korea Rural Affairs Corporation. In this case, it is important to quickly deploy a mobile siphon to the site for preliminary discharge, and this study evaluated the applicability of a mobile siphon with a diameter of 200 mm, a minimum water level difference of 6 m, 420 (m2/h), and 10,000 (m2/day), which can perform both preliminary and emergency discharge functions, to the Yugum Reservoir in Gyeongju City. The test bed, Yugum Reservoir, is a facility that was completed in 1945 and has been in use for about 78 years. According to the hydrological stability analysis, the lowest height of the current dam crest section is 27.15 (EL.m), which is 0.29m lower than the reviewed flood level of 27.44 (EL.m), indicating that there is a possibility of lunar flow through the embankment, and the headroom is insufficient by 1.72 m, so it was reviewed as not securing hydrological safety. The water level-volume curve was arbitrarily derived because it was difficult to clearly establish the water level-flow relationship curve of the reservoir since the water level-flow measurement was not carried out regularly, and based on the derived curve, the algorithm for operating small and medium-sized old reservoirs was developed to consider the pre-discharge time, the amount of spillway discharge, and to predict the reservoir lunar flow time according to the flood volume by frequency, thereby securing evacuation time in advance and reducing the risk of collapse. Based on one row of 200 mm diameter mobile siphons, the optimal pre-discharge time to secure evacuation time (about 1 hour) while maintaining 80% of the upper limit water level (about 30,000 m2) during a 30-year flood was analyzed to be 12 hours earlier. If the pre-discharge technology utilizing siphons for small and medium-sized old reservoirs and the algorithm for reservoir operation are implemented in advance in case of abnormal weather and the decision-making of managers is supported, it is possible to secure the safety of residents in the risk area of reservoir collapse, resolve the anxiety of residents through the establishment of a support system for evacuating residents, and reduce risk factors by providing risk avoidance measures in the event of a reservoir risk situation.

A Study on the Individual Radiation Exposure of Medical Facility Nuclear Workers by Job (의료기관 핵의학 종사자의 직무 별 개인피폭선량에 관한 연구)

  • Kang, Chun-Goo;Oh, Ki-Baek;Park, Hoon-Hee;Oh, Shin-Hyun;Park, Min-Soo;Kim, Jung-Yul;Lee, Jin-Kyu;Na, Soo-Kyung;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.9-16
    • /
    • 2010
  • Purpose: With increasing medical use of radiation and radioactive isotopes, there is a need to better manage the risk of radiation exposure. This study aims to grasp and analyze the individual radiation exposure situations of radiation-related workers in a medical facility by specific job, in order to instill awareness of radiation danger and to assist in safety and radiation exposure management for such workers. Materials and Methods: 1 January 2007 to 31 December 2009 to work in medical institutions are classified as radiation workers Nuclear personal radiation dosimeter regularly, continuously administered survey of 40 workers in three years of occupation to target, Imaging Unit beautifully, age, dose sector, job function-related tasks to identify the average annual dose for a deep dose, respectively, were analyzed. The frequency analysis and ANOVA analysis was performed. Results: Imaging Unit beautifully three years the annual dose PET and PET/CT in the work room 11.06~12.62 mSv dose showed the highest, gamma camera injection room 11.72 mSv with a higher average annual dose of occupation by the clinical technicians 8.92 mSv the highest, radiological 7.50 mSv, a nurse 2.61 mSv, the researchers 0.69 mSv, received 0.48 mSv, 0.35 mSv doctors orderly, and detail work employed the average annual dose of the PET and PET/CT work is 12.09 mSv showed the highest radiation dose, gamma camera injection work the 11.72 mSv, gamma camera imaging work 4.92 mSv, treatment and safety management and 2.98 mSv, a nurse working 2.96 mSv, management of 1.72 mSv, work image analysis 0.92 mSv, reading task 0.54 mSv, with receiving 0.51 mSv, 0.29 mSv research work, respectively. Dose sector average annual dose of the study subjects, 15 people (37.5%) than the 1 mSv dose distribution and 5 people (12.5%) and 1.01~5.0 mSv with the dose distribution was less than, 5.01~10.0 mSv in the 14 people (35.0%), 10.01~20.0 mSv in the 6 people (15.0%) of the distribution were analyzed. The average annual dose according to age in occupations that radiological workers 25~34 years old have the highest average of 8.69 mSv dose showed the average annual dose of tenure of 5~9 years in jobs radiation workers in the 9.5 mSv The average was the highest dose. Conclusion: These results suggest that medical radiation workers working in Nuclear Medicine radiation safety management of the majority of the current were carried out in the effectiveness, depending on job characteristics has been found that many differences. However, this requires efforts to minimize radiation exposure, and systematic training for them and for reasonable radiation exposure management system is needed.

  • PDF

Assessment on HACCP Recognition & Sanitary Management of the Industry Foodservice Manager in Seoul (식품 위해 요소 중점 관리 기준에 대한 서울 지역 사업체 급식 관리자의 위생관리평가)

  • 이헌옥;심재영;김영경;조민호;최호순;엄애선
    • Korean journal of food and cookery science
    • /
    • v.17 no.6
    • /
    • pp.542-548
    • /
    • 2001
  • Hazard Analysis Critical Control Point(HACCP) is becoming an important component of food safety worldwide. The aim of this study was to investigate comprehensively the education and knowledge level of food service managers on HACCP as well as applying HACCP system to industrial foodservice. Total 247 foodservice managers participated in the survey and 159 responses were used for analysis. The results were as follows: 1) 89% of foodservice managers were educated about HACCP, and 40.9% felt they did fully understand HACCP and 47.8% did half. 2) The score for the implementation of HACCP was in the order of apparatus and facility sanitation, personal sanitation, and time-temperature/etc. sanitation. 3) Foodservice managers who were taught HACCP kept a deep attention to food and personal sanitation, compared with those without education(p<0.05). However, the education time on HACCP affected conducting safety management. The results suggest that education and understanding of HACCP are positively related, and understanding of HACCP has a positive influence on conducting safety management.

  • PDF

A Study on Radiation Safety Evaluation for Spent Fuel Transportation Cask (사용후핵연료 운반용기 방사선적 안전성평가에 관한 연구)

  • Choi, Young-Hwan;Ko, Jae-Hun;Lee, Dong-Gyu;Jung, In-Su
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.4
    • /
    • pp.375-387
    • /
    • 2019
  • In this study, the radiation dose rates for the design basis fuel of 360 assemblies CANDU spent nuclear fuel transportation cask were evaluated, by measuring radiation source terms for the design basis fuel of a pressurized heavy water reactor. Additionally, radiological safety evaluation was carried out and the validity of the results was determined by radiological technical standards. To select the design basis fuel, which was the radiation source term for the spent fuel transportation cask, the design basis fuels from two spent fuel storage facilities were stored in a spent fuel transportation cask operating in Wolsung NPP. The design basis fuel for each transportation and storage system was based on the burnup of spent fuel, minimum cooling period, and time of transportation to the intermediate storage facility. A burnup of 7,800 MWD/MTU and a minimum cooling period of 6 years were set as the design basis fuel. The radiation source terms of the design basis fuel were evaluated using the ORIGEN-ARP computer module of SCALE computer code. The radiation shielding of the cask was evaluated using the MCNP6 computer code. In addition, the evaluation of the radiation dose rate outside the transport cask required by the technical standard was classified into normal and accident conditions. Thus, the maximum radiation dose rates calculated at the surface of the cask and at a point 2 m from the surface of the cask under normal transportation conditions were respectively 0.330 mSv·h-1 and 0.065 mSv·h-1. The maximum radiation dose rate 1 m from the surface of the cask under accident conditions was calculated as 0.321 mSv·h-1. Thus, it was confirmed that the spent fuel cask of the large capacity heavy water reactor had secured the radiation safety.

A Study on the Current Fire Insurance Subscription and Solutions for Ensuring the Safety of the Traditional Market (전통시장 안전성 확보를 위한 개선방안: 화재보험 가입실태를 중심으로)

  • Kim, Yoo-Oh;Byun, Chung-Gyu;Ryu, Tae-Chang
    • Journal of Distribution Science
    • /
    • v.9 no.4
    • /
    • pp.43-50
    • /
    • 2011
  • Concerning the risk factors of the outbreak of a fire in a traditional market, most of those markets are located in downtown areas or residential areas; thus, although their location may be favorable in terms of marketability, they face a potential risk in that a fire may develop into a large blaze owing to poor environment or the absence of facilities prepared for disaster during a fire. Moreover, as many people are densely poised in the markets, it is very probable that a fire may occur owing to the excessive use of heaters in the winter as well as the reckless use of electric and gas facilities. It seems that traditional markets encounter difficulty being insured against fire, because of their vulnerability and that the vast majority of small-scale sellers are likely to suffer mental anguish and tremendous physical injury in case of a fire. However, most of those sellers in the traditional markets are hand-to-mouth sellers, and they lack awareness of safety concerns and have insufficient experience in safe facility management. As small-scale sellers constitute the majority in the traditional market, the subscription rate of fire insurance in most of the traditional markets is low for the reasons of their needy circumstances and their financial burden. Statistically, the subscription by street vendors is non-existent; therefore, these vendors have a fairly limited access to indemnification after fire damage. Because of these problems, this study's purpose is to identify the current level of insurance subscription by these markets, which are exposed to poor facilities and vulnerability to fire. In order to fix this, it appears that shop owners and consumers will have to band together. For this study, we executed a fire policyholder fact-finding mission at traditional markets with approximately 108 and 981 stores. The research method was executed by an investigation using one-on-one individual interviews using a questionnaire. The contents investigated current insurance subscriptions. The method of analysis looked at the difference of insured amount according to volume size through cross-tabulation of the difference of insured amount by possession form, difference of insured amount by market form, difference of insured amount by category of business, difference of insured amount by market size, etc. Furthermore, the study should be used to propose solutions for problems through theoretical review with the use of a literature research, because the field case study was through interviews with the persons concerned, and the survey of the current insurance subscriptions by traditional market shopkeepers. The traditional market would generally have difficulty affording fire insurance. Fire insurance subscription rates of most of the market proved to be inactive, because of the economic burden of payment. Lack of funds is thought to be the main factor that causes a lack of realization about the necessity of fire insurance. In addition to expensive insurance premiums, sometimes, the companies' valuation of the businesses is lower than their actual valuations, and they do not pay out enough during a claim. The research presents an improvement plan that, when presented at the traditional markets, may strengthen their ability to procure fire insurance through the help of the central government. Researchers connected with the traditional market mainly accomplish the initial research. However, although this research has its limitations, it offers considerable benefits. For future researchers, I would suggest looking at several regions for comparison.

  • PDF

Evaluation of Spatial Dose Rate in Working Environment during Non-Destructive Testing using Radioactive Isotopes (방사성동위원소를 이용한 비파괴 검사 시 작업환경 내 공간선량률 평가)

  • Cho, Yong-In;Kim, Jung-Hoon;Bae, Sang-Il
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.373-379
    • /
    • 2022
  • The radiation source used for non-destructive testing have permeability and cause a scattered radiation through collisions of surrounding materials, which causes changes in the surrounding spatial dose. Therefore, this study attempted to evaluate and analyze the distribution of spatial dose by source in the working environment during the non-destructive test using monte carlo simulation. In this study, Using FLUKA, a simulation code, simulates 60Co, 192Ir, and 75Se source used in non-destructive testing, The reliability of the source term was secured by comparing the calculated dose rate with the data of the Health and Physics Association. After that, a non-destructive test in the radiation safety facility(RT-room) was designed to evaluate the spatial dose according to the distance from the source. As a result of the spatial dose evaluation, 75Se source showed the lowest dose distribution in the frontal position and 60Co source showed a dose rate of about 15 times higher than that of 75Se and about 2 times higher than that of 192Ir. In addition, the spatial dose according to the distance tends to decrease according to the distance inverse square law as the distance from the source increases. Exceptionally, 60Co, 192Ir, and 75Se sources confirmed a slight increase within 2 m of position. Based on the results of this study, it is believed that it will be used as supplementary data for safety management of workers in radiation safety facilities during non-destructive testing using radioactive isotopes.

Study on Influencing Factors of Traffic Accidents in Urban Tunnel Using Quantification Theory (In Busan Metropolitan City) (수량화 이론을 이용한 도시부 터널 내 교통사고 영향요인에 관한 연구 - 부산광역시를 중심으로 -)

  • Lim, Chang Sik;Choi, Yang Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.1
    • /
    • pp.173-185
    • /
    • 2015
  • This study aims to investigate the characteristics and types of car accidents and establish a prediction model by analyzing 456 car accidents having occurred in the 11 tunnels in Busan, through statistical analysis techniques. The results of this study can be summarized as below. As a result of analyzing the characteristics of car accidents, it was found that 64.9% of all the car accidents took place in the tunnels between 08:00 and 18:00, which was higher than 45.8 to 46.1% of the car accidents in common roads. As a result of analyzing the types of car accidents, the car-to-car accident type was the majority, and the sole-car accident type in the tunnels was relatively high, compared to that in common roads. Besides, people at the age between 21 and 40 were most involved in car accidents, and in the vehicle type of the first party to car accidents, trucks showed a high proportion, and in the cloud cover, rainy days or cloudy days showed a high proportion unlike clear days. As a result of analyzing the principal components of car accident influence factors, it was found that the first principal components were road, tunnel structure and traffic flow-related factors, the second principal components lighting facility and road structure-related factors, the third principal factors stand-by and lighting facility-related factors, the fourth principal components human and time series-related factors, the fifth principal components human-related factors, the sixth principal components vehicle and traffic flow-related factors, and the seventh principal components meteorological factors. As a result of classifying car accident spots, there were 5 optimized groups classified, and as a result of analyzing each group based on Quantification Theory Type I, it was found that the first group showed low explanation power for the prediction model, while the fourth group showed a middle explanation power and the second, third and fifth groups showed high explanation power for the prediction model. Out of all the items(principal components) over 0.2(a weak correlation) in the partial correlation coefficient absolute value of the prediction model, this study analyzed variables including road environment variables. As a result, main examination items were summarized as proper traffic flow processing, cross-section composition(the width of a road), tunnel structure(the length of a tunnel), the lineal of a road, ventilation facilities and lighting facilities.