• Title/Summary/Keyword: Facility Energy Data

Search Result 300, Processing Time 0.039 seconds

Analysis of Feasible Biomass Potential Using GIS and Aggregating Agricultural Census Data (GIS와 농업통계자료를 활용한 바이오매스 가용부존량 분석)

  • Kim, Han-Joong;Hong, Seong-Gu
    • KCID journal
    • /
    • v.17 no.2
    • /
    • pp.82-94
    • /
    • 2010
  • Recently, biomass application for energy is getting more interests from many countries since biomass is widely available over the nation wide, whereas fossil fuels are produced in several limited regions. Recognizing the importance, government is promoting renewable energy use in Korea. The locational characteristics of the existing biomass potential directly can be used to decide scale of power plant for local agricultural facility. Although there are a few studies on feasible biomass potential in local areas, it is expected that both government and commercial sectors recognize the potential of biomass energy and the importance of reducing greenhouse gases. When planning biomass energy systems, biomass price is determined by the costs of collection, transportation, chipping, drying if required. In this paper investigates the economic and spatial characteristic of biomass location by land use map. However typical area of each categories in local region is not correct to agricultural census data. Therefore we concerned about how to calculate feasible biomass potential which it can be describing total amount of plant scale, and to match both of data. Even though its spatial distribution, in rural area in Korea, to expand biomass energy programs in the area, government serve to find areas of higher biomass production with suitable locations for plants to convert to bio-energy in order to increase the usage of renewable energy.

  • PDF

The MARS Simulation of the ATLAS Main Steam Line Break Experiment

  • Ha, Tae Wook;Yun, Byong Jo;Jeong, Jae Jun
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.112-122
    • /
    • 2014
  • A main steam line break (MSLB) test at the ATLAS facility was simulated using the best-estimate thermal-hydraulic system code, MARS-KS. This has been performed as an activity at the third domestic standard problem for code benchmark (DSP-03) that has been organized by Korea Atomic Energy Research Institute (KAERI). The results of the MSLB experiment and the MARS input data prepared for the previous DSP-02 using the ATLAS facility were provided to participants. The preliminary MSLB simulation using the base input data, however, showed unphysical results in the primary-to-secondary heat transfer. To resolve the problems, some improvements were implemented in the MARS input modelling. These include the use of fine meshes for the bottom region of the steam generator secondary side and proper thermal-hydraulics calculation options. Other input model improvements in the heat loss and the flow restrictor models were also made and the results were investigated in detail. From the results of simulations, the limitations and further improvement areas of the MARS code were identified.

Development of An Integrated Test Facility (ITF) for the Advanced Man Machine Interface Evaluation

  • Oh, In-Seok;Cha, Kyung-Ho;Lee, Hyun-Chul;Sim, Bong-Sick
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.117-122
    • /
    • 1995
  • An Integrated Test Facility(ITF) is a human factors experimental environment to evaluate an advanced man machine interface(MMI) design. The ITF includes a human machine simulator(HMS) comprised of a nuclear power plant function simulator, man-machine interface, experiment control station for the experiment control and design, human behavioural data measurement system, and data analysis and experiment evaluation supporting system(DAEXESS). The most important features of ITF is to secure the flexibility and expandibility of Man Machine Interlace(MMI) design to change easily the environment of experiments to accomplish the experiment's objects In this paper, we describe a development scope and characteristics of the ITF such as, hardware and software development scope and characteristics, system thermohydraulic modelling characteristics, and experiment station characteristics for the experiment variables design and control, to be used as an experiment environment for the evaluation of VDU-based control room.

  • PDF

A Study on Odor Dispersion Prediction of Waste Treatment Facilities Using CFD (CFD를 이용한 쓰레기 처리시설의 악취확산 예측에 관한 연구)

  • Kyung, Seo-Kyung;Kim, Kong-Sook;Kim, Byung-Seon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.342-349
    • /
    • 2009
  • The purpose of this study is to estimate efficiently an odor dispersion from waste treatment facility for a crematory and a neighborhood facility, then propose planning, a location of an opening or the arrangement of the trees. Hence, offer a comfortable environment for a resident. For this, first the research data about estimating odor dispersion from waste treatment facility and odor are analyzed, then research an ingredient, characteristic, a direct effect for human and a method of measurement. Second, with on-site survey, check odorimetry and the source of odor dispersion, then apply this to the boundary condition of CFD simulation. Third, analyse by the hour for the 2008 standard weather data of Cheon-an, then apply summer data that odor dispersion is active, winter data relatively slow and an annual mean velocity and wind to the simulation. Even if a crematory and neighborhood facility located on south and north from waste treatment facility are at the low rate, the south and north wind will be applied to the simulation. Fourth, with CFD simulation result, predict an odor dispersion, then propose a solution which is considered an odor dispersion, a location of an opening and the arrangement of the trees. Consequently, this study will have an effect on an environment of a resident.

  • PDF

The Development of the Simulation Input Library (시뮬레이션 입력값 라이브러리 구축)

  • Kang, Su-Hyun;Yu, Ji-Suck;Baek, Seung-Hyo;Cho, Young-Hum;Kim, Kwang-Woo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.287-292
    • /
    • 2011
  • It has found that the using library base on criteria of a foreign country resulted in problem of reliability. In order to obtain reliable result, it was necessary to develop the simulation input library based on domestic condition. So, this study was conducted for making the library in accordance with domestic condition when doing simulation modeling about the exist and new buildings. The range of library were consist of material, facility systems, schedules and weather data. And Energy Plus program was used when making library. We hope that the developed library will contribute to reliability when simulating exist and new buildings.

  • PDF

Evaluation of Flow Accelerated Corrosion of Carbon Steel with Rotating Cylinder (Rotating cylinder를 이용한 탄소강의 유동가속부식 평가)

  • Park, Tae Jun;Lee, Eun Hee;Kim, Kyung Mo;Kim, Hong Pyo
    • Corrosion Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.257-262
    • /
    • 2012
  • Flow accelerated corrosion (FAC) of the carbon steel piping in nuclear power plants (NPPs) has been major issue in nuclear industry. Rotating cylinder FAC test facility was designed and fabricated and then performance of the facility was evaluated. The facility is very simple in design and economic in fabrication and can be used in material and chemistry screening test. The facility is equipped with on line monitoring of pH, conductivity, dissolved oxygen(DO), and temperature. Fluid velocity is controlled with rotating speed of the cylinder with a test specimen. FAC test of SA106 Gr. B carbon steel under 4 m/s flow velocity was performed with the rotating cylinder at DO concentration of less than 1 ppb and of 1.3 ppm. Also a corrosion test of the carbon steel at static condition, that is at zero fluid velocity, of test specimen and solution was performed at pH from 8 to 10 for comparison with the FAC data. For corrosion test in static condition, the amount of non adherent corrosion product was almost constant at pH ranging from 8 to 10. But adherent corrosion product decreased with increasing pH. This trend is consistent with decrease of Fe solubility with an increase in pH. For FAC test with rotating cylinder FAC test facility, the amount of non adherent corrosion product was also almost same for both DO concentrations. The rotating cylinder FAC test facility will be further improved by redesigning rotating cylinder and FAC specimen geometry for future work.

Case Study for Energy Conservation Measures of Hospital Buildings Using the Analysis of Energy Consumption Structure (의료시설 에너지절약 운영방법 도출을 위한 사례분석을 통한 에너지 영향요소 분석)

  • Lee, Sangmoon;Cho, Jinkyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.2
    • /
    • pp.57-69
    • /
    • 2019
  • Because the hospital building operates 24 hours a day, 365 days a year for treatment and restoration of patients, it has a different pattern of energy use than that of ordinary buildings. Hospitals contribute to energy consumption and have a negative environmental impact. This study aims to find how meaningful energy performance, reflecting good energy management and ECMs, can be operated for hospital buildings, a category encompassing complex buildings with different systems and large differences between them. In this study, we proposed the energy diagnosis & evaluation method and energy management process to verify energy saving through operation data based on system & facility characteristics, operation pattern and energy consumption characteristics of hospital building. Energy consumption structures were surveyed throughout 4 reference hospital in Seoul, Korea. Findings confirm that different hospital departments have hugely different energy-demand profiles. Energy efficiency and energy saving potentials are presented. The energy performance analysis can be applied to a wide range of problems in energy-system operation.

Dose Determination in the IR-221 Gamma Facility Using a Monte Carlo Simulation (몬테칼로 시뮬레이션을 이용한 IR-221의 선량 평가)

  • Lim, Ik-Sung;Kim, Ki-Yup;Roh, Gyu-Hong;Lee, Chung
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.1
    • /
    • pp.21-26
    • /
    • 2007
  • This study is performed to evaluate the dose rate and to analyze the dose distribution of the gamma irradiation facility (IR-221) by using a Monte Calro simulation, which is helpful of upgrading the radiation processing qualification. Monte Cairo simulation is performed by MCNP4B code. Dose rates were measured at total 369 points with alanine dosimeters to compare the calculation results and the measurements data. The results have shown that the MCNP4B code is very useful to determine the dose distribution of the IR-221 gamma irradiation facility, as the calculation dose rate is within about ${\pm}5%$ of the measurement data. Dosimetry about the gamma irradiation facility usually needs enormous manpower and time. However Monte Cairo calculation method can reduce the tedious dosimetry jobs and improve the irradiation processing qualification, which will probably contribute to obtain the reliability of the irradiation products.

PILLAR: Integral test facility for LBE-cooled passive small modular reactor research and computational code benchmark

  • Shin, Yong-Hoon;Park, Jaeyeong;Hur, Jungho;Jeong, Seongjin;Hwang, Il Soon
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3580-3596
    • /
    • 2021
  • An integral test facility, PILLAR, was commissioned, aiming to provide valuable experimental results which can be referenced by system and component designers and used for the performance demonstration of liquid-metal-cooled, passive small modular reactors (SMRs) toward their licensing. The setup was conceptualized by a scaling analysis which allows the vertical arrangements to be conserved from its prototypic reactor, scaled uniformly in the radial direction achieving a flow area reduction of 1/200. Its final design includes several heater rods which simulate the reactor core, and a single heat exchanger representing the steam generators in the prototype. The system behaviors were characterized by its data acquisition system implementing various instruments. In this paper, we present not only a detailed description of the facility components, but also selected experimental results of both steady-state and transient cases. The obtained steady-state test results were utilized for the benchmark of a system code, achieving a capability of accurate simulations with ±3% of maximum deviations. It was followed by qualitative comparisons on the transient test results which indicate that the integral system behaviors in passive LBE-cooled systems are able to be predicted by the code.

The Development of a Web-based Realtime Monitoring System for Facility Energy Uses in Forging Processes (단조공정에서 설비 에너지 사용에 대한 웹 기반 실시간 모니터링 시스템 개발)

  • Hwang, Hyun-suk;Seo, Young-won;Kim, Tae-yeon
    • Journal of Internet Computing and Services
    • /
    • v.19 no.1
    • /
    • pp.87-95
    • /
    • 2018
  • Due to global warming and increased energy costs around the world, interests of energy saving and efficiency have been increased. In particular, forging factories need methods to save energy and increase productivity because of needing amounts of energy uses. To solve the problem, we propose a system, which includes collection, monitoring, and analysis process, to monitor energy uses each facility in realtime based on the IoT devices. This system insists of worksheets management, facility/energy management, realtime monitoring, history search, data analysis through connecting with existed ERP/MES Systems in manufacturing factories. The energy monitoring process is to present used energy collected from IoT devices connected with installed gasmeter and wattmeter each facility. This system provide the change of energy uses, usage fee, energy conversion, and green gas information in realtime on Web and mobile devices. This system will be enhanced with energy saving technology by analyzing constructed big data of energy uses. We can also propose a method to increase productivity by integrating this system with functions of digitalized worksheets and optimized models for production process.