• 제목/요약/키워드: Facility Capacity

검색결과 629건 처리시간 0.039초

시뮬레이션 모델을 활용한 인천국제공항 수용량 산정에 관한 연구 (Estimation of Incheon International Airport Capacity by using Aircraft Delay Simulation Model)

  • 방준;김도현
    • 한국항공운항학회지
    • /
    • 제27권1호
    • /
    • pp.20-25
    • /
    • 2019
  • To prepare for the ever-increasing demand for air transport, airport operators should be well aware of the timing of the saturation of the facility and increase the capacity of the airport through extension or extension. The capacity of an airport is determined by the smallest value of the facilities that make up the airport, but it is generally customary to determine the capacity of the costly and time-consuming runway as a whole for the airport. For analyzing the capacity of the runway capacity, the study used the most accurate microscopic air traffic simulation, Simmod-PRO, to analyze the saturation time of three runways currently in Incheon International Airport's operation, and calculate the appropriate time for operation of the 4th runway. The study also calculate the relocation of Airport's high-speed exit taxiway for analyzing the increasing of capacity.

농촌지역 개발사업 공동시설의 활용도 기준체계 정립을 통한 실태 파악 연구 (Comparing Stakeholder Perceptions on the Reasons for Rural Underutilization of Common Facilities )

  • 김은솔;이재호
    • 농촌계획
    • /
    • 제29권3호
    • /
    • pp.53-67
    • /
    • 2023
  • In this study, the problem of the idleness of public buildings in rural areas is seriously emerging, but there are no clear standards for assessing the utilization of these buildings. Therefore, this study endeavors to investigate the actual state of idleness of buildings created by rural area development projects based on the criteria for each type. As part of this study, rural facilities were selected in two locations in Sangju City and Miryang City among the target areas of the Rural Agreement. Utilization evaluation criteria were developed to identify the conditions of underutilization. In order to determine the utilization pattern for each facility type, an in-depth interview with the operator and an inspection of the facility were conducted. Based on the analysis, the degree of utilization (e.g., low use, non-use, etc.) was different for each facility type, and among the four facility types (rural tourism, culture and welfare, exercise and recreation, income-based), rural tourism was rated as the least efficient. It has been found that the operating entity's capacity has a significant influence on the utilization of facilities. Socioeconomic factors, such as a decrease in utilization rates, are greatly influenced by the operating entity's capacity. Therefore, support from local governments as well as the national level is required to recycle idle facilities. Lastly, this study suggests the need for different standards for utilization, depending on the type of facility. This moves beyond checking the degree of idleness by the same standard that was previously implemented.

DEVELOPMENT OF A COMPUTER PROGRAM FOR AN ANALYSIS OF THE LOGISTICS AND TRANSPORTATION COSTS OF THE PWR SPENT FUELS IN KOREA

  • Cha, Jeong-Hun;Choi, Heui-Joo;Lee, Jong-Youl;Choi, Jong-Won
    • Journal of Radiation Protection and Research
    • /
    • 제34권1호
    • /
    • pp.1-7
    • /
    • 2009
  • It is expected that a substantial amount of spent fuels will be transported from the four nuclear power plant (NPP) sites in Korea to a hypothetical centralized interim storage facility or a final repository in the near future. The cost for the transportation is proportional to the amount of spent fuels. In this paper, a cost estimation program is developed based on the conceptual design of a transportation system and a logistics analysis. Using the developed computer program, named as CASK, the minimum capacity of a centralized interim storage facility (CISF) and the transportation cost for PWR spent fuels are calculated. The PWR spent fuels are transported from 4 NPP sites to a final repository (FR) via the CISF. Since NPP sites and the CISF are located along the coast, a sea-transportation is considered and a road-transportation is considered between the CISF and the FR. The result shows that the minimum capacity of the interim storage facility is 15,000 MTU.

시설용량을 초과하는 폐수량의 유입확률 분석을 위한 극치분포모델의 적용에 관한 연구 (A study on the application of the extreme value distribution model for analysis of probability of exceeding the facility capacity)

  • 최성현;유순유;박태욱;박규홍
    • 상하수도학회지
    • /
    • 제30권4호
    • /
    • pp.369-379
    • /
    • 2016
  • It was confirmed that the extreme value distribution model applies to probability of exceeding more than once a day monthly the facility capacities using data of daily maximum inflow rate for 7 wastewater treatment plant. The result of applying the extreme value model, A, D, E wastewater treatment plant has a problem compared to B, C, F, G wastewater treatment plant. but all the wastewater treatment plant has a problem except C, F wastewater treatment plant based 80% of facility capacity. In conclusion, if you make a standard in statistical aspects probability exceeding more than once a day monthly can be 'exceed day is less than a few times annually' or 'probability of exceeding more than once a day monthly is less than what percent'.

Radiological safety assessment of lead shielded spent resin treatment facility with the treatment capacity of 1 ton/day

  • Byun, Jaehoon;Choi, Woo Nyun;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.273-281
    • /
    • 2021
  • The radiological safety of the spent resin treatment facility with a14C treatment capacity of 1 ton/day was evaluated in terms of the external and internal exposure of worker according to operation scenario. In terms of external dose, the annual dose for close work for 1 h/day at a distance of more than 1 m (19.8 mSv) satisfied the annual dose limit. For 8 h of close work per day, the annual dose exceeded the dose limit. For remote work of 2000 h/year, the annual dose was 14.4 mSv. Lead shielding was considered to reduce exposure dose, and the highest annual dose during close work for 1 h/day corresponded to 6.75 mSv. For close work of 2000 h/year and lead thickness exceeding 1.5 cm, the highest value of annual dose was derived as 13.2 mSv. In terms of internal exposure, the initial year dose was estimated to be 1.14E+03 mSv when conservatively 100% of the nuclides were assumed to leak. The allowable outflow rate was derived as 7.77E-02% and 2.00E-01% for the average limit of 20 mSv and the maximum limit of 50 mSv, respectively, where the annual replacement of the worker was required for 50 mSv.

소듐냉각고속로 KALIMER-600 축소 물모의 열유동 가시화 실험장치 구축 및 거시 유동장 특성 측정 (Water-Simulant Facility Installation for the Sodium-Cooled Fast Reactor KALIMER-600 and Global Flow Measurement)

  • 차재은;김성오
    • 한국가시화정보학회지
    • /
    • 제9권4호
    • /
    • pp.54-62
    • /
    • 2011
  • KAERI has developed a KALIMER-600 which is a pool-type sodium-cooled fast reactor with a 600MWe electric generation capacity. For a SFR development, one of the main topics is an enhancement of the reactor system safety. Therefore, we have a long-term plan to design the large sodium experimental facility to evaluate the reactor safety and component performance. In order to extrapolate a thermal hydraulic phenomena in a large sodium reactor, the thermal hydraulics phenomena is under investigation in a 1/$10^{th}$ water-simulant facility for the KALIMER-600. In this paper, we shortly described the experimental facility setup and the measurement of the isothermal global flow behavior. For the flow field measurement, the PIV method was used in a transparent Plexiglas reactor vessel model at around $20^{\circ}C$ water condition.

대구시 하수처리장 운전실태에 따른 중수도 도입 방안 연구 (A Research for Introduction of Graywater Facility on Analysis of Actual Conditions of Sewage Treatment Plant in Daegu City)

  • 최미영;나욱호;홍원화;김삼열
    • 한국주거학회논문집
    • /
    • 제16권1호
    • /
    • pp.27-35
    • /
    • 2005
  • It has seen the significant increase of water consumption rate due to rapid industrialization, high-densities of city, and increasing the population; thereby leads further water resource required in near future. In order to solve this deficit there are one of solution that gray water method demonstrates advantages regarding the questions of optimal water utility and thereby master plan of water. The method of study is analysis of investigation data through interview and research of sewage treatment plants in Daegu City. Through these analysis, this paper examines the capacity of graywater and optimal graywater facility.

농수축산물저장을 위한 지하암반냉동창고의 경제성분석 (An Economy Analysis on the Underground Food Storage)

  • 김준홍
    • 산업경영시스템학회지
    • /
    • 제19권38호
    • /
    • pp.189-197
    • /
    • 1996
  • It is in general reported that construction cost in an underground storage facility is less than that of the same capacity and features in an aboveground facility. Since these costs have a derivative with respect to facility size and fridging unit, the cost of construction and fridging unit are sensitive to location of storage, items to store, and rock quality of storage site. In this paper, to analyse an economic investment point for the underground food storage relative to aboveground storage, we compared these two models which have equivalent annual cost with the total cost that consists of initial facility investment cost and annual operation cost. Based on comparison of the economic investment in the underground with aboveground storage. an economic initial investment cost has been suggested for storing the agricultural and fish products.

  • PDF

이진정수계획법을 사용한 복층숙소의 최적 방 배정문제 (Optimal Room Assignment Problem for Multi-floor Facility using Binary Integer Programming)

  • 이상원;임석철
    • 산업공학
    • /
    • 제21권2호
    • /
    • pp.170-176
    • /
    • 2008
  • Consider a multi-floor facility with multiple rooms of unequal size on each floor. Students come from many organizations to attend the conference to be held at this facility. In assigning the rooms to the students, several constraints must be met; such as boys and girls must not be assigned to the rooms on the same floor. Given the capacity of each room and the number of students from each organization, the problem is assigning students to rooms under a set of constraints and various objectives. We present six models with different objective functions; and formulate them as binary integer programming problems. A numerical example and a case study follow to illustrate the proposed models.

배전용 변압기 단락강도 시험설비 개발 (Development of Short-circuit Testing Facility for Distribution Transformers)

  • 박지훈;민윤홍;강영학;유호근;안규선;함길호;오창주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.64-67
    • /
    • 2002
  • To increase the short-circuit testing capacity of distribution transformers, testing facility has been installed for KEPCO in Vi-wang. The power supply of testing facility is directly supplied from the network substation located closely. Testing can be performed up to 300 kVA for single-phase transformers, 500 kVA for three-phase transformers. Operating with this facility, the distribution company is able to maintain the reliable supply of electricity. Also the critical quality of transformers from manufacturers can be verified by short-circuit testing. This paper describes the design concept and specification of newly developed equipment and the procedure of short-circuit test.

  • PDF