• Title/Summary/Keyword: Facility Capacity

Search Result 629, Processing Time 0.041 seconds

Optimal Dynamic Operating Policies for a Tandem Queueing Service System

  • Hwang, Dong-Joon
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.4 no.1
    • /
    • pp.51-67
    • /
    • 1979
  • This paper considers the problem of determining an optimal dynamic operating policy for a two-stage tandem queueing service system in which the service facilities (or stages) can be operated at more than one service rate. At each period of the system's operation, the system manager must specify which of the available service rates is to be employed at each stage. The cost structure includes an operating cost for running each stage and a service facility profit earned when a service completion occurs at Stage 2. We assume that the system has a finite waiting capacity in front of each station and each customer requires two services which must be done in sequence, that is, customers must pass through Stage 1 and Stage 2 in that order. Processing must be in the order of arrival at each station. The objective is to minimize the total discounted expected cost in a two-stage tandem queueing service system, which we formulate as a Discrete-Time Markov Decision Process. We present analytical and numerical results that specify the form of the optimal dynamic operating policy for a two-stage tandem queueing service system.

  • PDF

Modeling and Optimization of Rice Drying and Storage System in Korea(I) -Layout and Design of Model System- (한국에 있어서 미곡(米穀)의 건조(乾燥) 및 저장(貯藏)을 위한 시스템의 모델 개발 및 적정규모 선정에 관한 연구(I) -모델 시스템의 Layout 및 설계-)

  • Park, Kyung-Kyoo
    • Journal of Biosystems Engineering
    • /
    • v.11 no.2
    • /
    • pp.66-75
    • /
    • 1986
  • In order to improve the traditional post harvest system in Korea, a model for mechanized grain drying and storage facilities was developed. Also, a computer program for the model system was developed. For the study, flat type steel bin and circulation type dryer were selected for the model and Fortran language was used for the computer program. This program was tested by using various practical data. The following results were obtained from the study: 1. The general model developed can be used for designing a rough rice drying and storage facility within the range from 100 ton to 1000 ton capacity. 2. Major output of the computer program for designing a model system were as follow; a. The dimension of the plant. b. The storage bin size, dryer number and dryer size. c. The dimension of individual equipment and its required HP. d. Capital requirement and operating cost of the model system.

  • PDF

Study on the Smart Charging for Plug-in Hybrid Electric Vehicle (플러그인 하이브리드 전기자동차의 스마트 충전에 관한 연구)

  • Roh, Chul-Woo;Kim, Min-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.349-352
    • /
    • 2008
  • The most concerning issue in these days is the energy crisis by increasing threat of global warming and depletion of natural resources. In the situations, the Plug-in Hybrid Electric Vehicle (PHEV) is drawing attention from many countries for the next generation's car which has higher fuel efficiency and lower environmental impact. This paper presents simulation results about the limit capacity of central power-grid which doesn't have enough surplus electric power for charging PHEVs. Therefore, this paper also presents a smart charging system that can charge the PHEVs with a function of distributing demands of charging. The smart charging system is an agent facility between the government and consumer, which can recommend the best time to charge the battery of PHEVs by the lowest energy cost. This function of choosing time-slots is the technical system for the government which wants to control the consumption rate of electric power for PHEVs. Finally, this paper presents the economic feasibility of PHEVs from the two kinds of price system, midnight electric price and home electric price.

  • PDF

A Capacity of Refuge area in Multiple Occupancy Building with Underground Facility (지하연계복합건축물의 피난 안전구역 면적 산정)

  • Kim, Jong-Sung;Kim, Woon-Hyung;Lee, Yong-Jae
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.272-276
    • /
    • 2011
  • 최근 발생한 부산 해운대 화재 이후 피난 활동이 제한적인 고층 건축물의 화재 안전에 대한 관심이 증대되고 있다. 그러나 현행 규정은 50층 이상의 초고층 건축물을 대상으로 하고 있으며 상대적으로 준 초고층 건축물에 대한 제도적 기반과 연구가 미비한 실정이다. 따라서 본 연구에서는 지하연계복합건축물에 관한 피난 안전구역면적 산정 기준에 대한 적용성을 분석하고자 국외의 관련 기준과 비교 분석하였다. 그 결과, 수용 인원에 관한 기준은 홍콩, 한국, 싱가포르, 중국 순으로 강화 적용하고 있으며 피난안전구역의 면적은 싱가포르의 경우 전체 수용 인원의 50% 이상과 1명당 $0.3m^2$을 전제로 하는 피난안전구역의 면적 기준이 국내의 각 층별 1/10의 면적의 합과 동일한 것으로 분석되었다.

  • PDF

A Smoke Management System Design For Semiconductor Fabrication Facilities (반도체 공장의 제연설계)

  • ;Michael J. Ferreira
    • Fire Science and Engineering
    • /
    • v.14 no.4
    • /
    • pp.23-28
    • /
    • 2000
  • A performance-based design of smoke management systems for semiconductor fabrication facilities is described in this paper. The example of one such facility is discussed. Performance criteria for smoke control systems were established, effective smoke removal system features were identified and optimal system exhaust capacity requirements were developed by applying engineering tools including Fire Dynamic Simulator model. Considering the fact that the absence of relevant design guide, codes for consensus standards for semiconductor smoke design in Korea and United States this performance based approach can and should be applied to other fabrication facilities designs.

  • PDF

Economic Evaluation of Various Cooling Systems (냉방기기별 경제성 평가)

  • Kim, Young-Il;Cho, Keum-Nam
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.214-219
    • /
    • 2008
  • In this study, medium capacity EHP and GHP for air-conditioning a building with a floor area of $1,200\;m^2$ are compared economically. To consider all the factors of initial and operation costs effectively, an annual equal payment method is proposed. For the initial cost, equipment, construction, installation, electric facility, financial subsidy and tax cut are considered. Basic electricity, energy(electricity and gas), space charge, labor, insurance and repair are considered for the operation cost. Under the assumptions made in this study, overall cost of EHP is less than that of GHP. However, different outcome may result if different assumptions are made. This study is useful for performing an economic evaluation of various air-conditioning systems.

  • PDF

CONSIDERATION OF APPLICATION FOR OPTICAL COMPOSITE POWER CABLE (전력/광 복합 케이블의 적용에 대한 고찰)

  • Kim, J.W.;Kim, H.K.;Ha, B.D.;Lee, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1547-1549
    • /
    • 1994
  • In recent years, fiberoptic technology is becoming indispensable in establishing communication networks due to its low loss, high capacity and non-inductive properties. In the power industry as well, the technology is being required to cable and facility monitering, and control system. But, duct in the manhole and space in the culvert are required to fiberoptic cable that is separated from power cable. Therefore, some cable makers and R&D has been studying the composite fiber/power cables. This report introduces the outline of ABF system, construction and properties of optical composite power cable that used ABF technology.

  • PDF

Waste Management and Treatment of Decommissioned Radioactive Combustible Waste

  • Min, B.Y.;Lee, Y.J.;Yun, G.S.;Lee, K.W.;Moon, J.K.
    • Journal of Nuclear Fuel Cycle and Waste Technology
    • /
    • v.1 no.1
    • /
    • pp.75-82
    • /
    • 2013
  • A large quantity of radioactive waste was generated during the decommissioning of the KRR and UCF. The radioactive waste was packed into 200 liter drums and 4m3 containers and these were temporarily stored onsite until their final disposal in the national repository facility. Some of the releasable waste was freely released and utilized for non-nuclear industries. The combustible wastes were treated by the utilization of an incinerator with a capacity of on average 20 kg/hr.

An experimental study on the performance of a window system air-conditioner using R407C and R410B (R407C 및 R410B 적용 창문형 에어컨의 성능에 관한 실험적 연구)

  • Kim, M.H.;Shin, J.S.;Kim, K.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.536-544
    • /
    • 1997
  • This study presents test results of a residential window system air-conditioner using R22 and two potential alternative refrigerants, R407C and R410B. A series of performance tests was performed for the basic and liquid-suction heat exchange cycle in a psychrometric calorimeter test facility. For R407C, the same rotary compressor was used as in the R22 system. However, compressor for the R410B system was modified to provide the similar cooling capacity. The evaporator circuit was changed to get a counter-cross flow heat exchanger to take advantage of zeotropic mixture's temperature glide, and liquid-line suction-line heat exchange cycle was also considered to improve the performance of the system. Test results were compared to those for the basic R22 system.

  • PDF

Productivity of Aquaculture Facility Utilization (양식장 이용에 따른 생산성에 관한 연구)

  • Eh, Youn-Yang
    • The Journal of Fisheries Business Administration
    • /
    • v.45 no.2
    • /
    • pp.85-95
    • /
    • 2014
  • Fish stocking is important element of land-based aquaculture management. To maintain constant stocking rate considering biological and economic condition is a convenient strategy in intensive aquaculture. This study is aimed to analyze the effect of over-stocking(more than aquaculture capacity) for certain periods of time. This study make the mathematical decision making model that finds the value of decision variable to minimize cost that sums up the water pool usage cost and sorting cost under critical standing corp constraint. The proposed mathematical decision making model was applied to 12 sample combination of sorting cost and the number of fish on the Oliver flounder culture farms. If a immature fish can be sold for high price than farming cost, restricted over-stocking resulted in a improvement of economic performance. When extensive comparable biological and market data become available, analysis model can be widely applied to yield more accurate results.