• Title/Summary/Keyword: Facility Capacity

Search Result 633, Processing Time 0.029 seconds

A Study on the Temporary Storage Facility for Mitigating the Leakage Accident (누출 사고 완화를 위한 임시 저장 시설에 관한 연구)

  • Song, Hyeon Oh;Lee, Chang Jun
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.3
    • /
    • pp.1-5
    • /
    • 2020
  • The leakage accident from a storage tank in an oil refinery plant occurred in April 2014 and the total loss is KRW 18 billion. This accident has prompted many companies to develop their own mitigation system to minimize the loss of the leakage accident. The aim of this study is to design the temporary storage facility system for dealing with leakage accidents. The basic concept of this system is that the leakage fluid of a hazardous material flows into a temporary storage tank and this is transferred to a spare tank by a pump as avoiding the overflow of a temporary storage tank. In order to design this system, the leakage velocity and quantity according to time series should be evaluated. In addition, a proper pump capacity should be determined to avoid repeating the pump switching on and off frequently. In this study, the benzene tank is selected to verify the efficacy of this system. This study can play a critical role to provide a guideline for designing a new system.

Characteristics of Compost Produced from the Composting Facility at Nanjido (난지도 퇴비화시범시설에서 생산되는 퇴비의 품질특성)

  • Namkoong, Wan;Kim, Joung-Dae
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.5 no.2
    • /
    • pp.57-64
    • /
    • 1997
  • This study was performed to investigate the characteristics of compost produced from the composting facility at Nanjido. The capacity of the facility is 10 ton/day. Feed material was food waste generated in Seoul. Moisture content of the compost product was 31% and conductivity was 2.6 mmhos/cm. The compost product met Korean quality standards and EC quality standards for VS and C/N ratio. In case of TOC and TKN, they were met with Japan quality standards. The water soluble-C/N ratio finally reached about 5 based on dry compost. The color of compost product was dark brown. The product had earthy smell. Heavy metal contents of the compost were below Korean quality standards by wet basis.

  • PDF

A Study on the International Accreditation Standard and Unit Spatial Organization of Public School in Korea (국내공립학교의 국제인증기준과 단위공간구성에 관한 연구)

  • Lee, Eul-Gyu;Jeon, You-Chang
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.23 no.1
    • /
    • pp.13-22
    • /
    • 2016
  • Recently, Korea has been established and operated International Schools manifesting to improve the nation's capacity of the foreign languages skill and to cultivate internationally trained professional manpower. In order to achieve the vision of a world-class educational organization, it has to be designed for the facility standards to meet the international accreditation standards. Therefore, the main purpose of this study is to research about basic resources through comparison of facility conditions between public schools in Korea and international accredited schools. By comparing those two different plan drawings are found the following things. First, Schools which established with International Accreditation Standard are prepared detailed criteria for the facility, Furthermore information about the furnishings included, in addition to specific equipments for classes are stated to be prepared. Secondly, it is more effective when special classrooms such as music and science are equipped with various spatial elements, enough educational equipment storage, teacher's study rooms, practical training rooms and student's activity rooms to support various teaching programs and learning efficiently. Lastly, there was a clear tendency that not only hardware but also software standards for the audiovisual room and library have been more enhanced to enable multidisciplinary educational approaches with the recent education training trend.

A Heuristic Algorithm for Optimal Facility Placement in Mobile Edge Networks

  • Jiao, Jiping;Chen, Lingyu;Hong, Xuemin;Shi, Jianghong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.7
    • /
    • pp.3329-3350
    • /
    • 2017
  • Installing caching and computing facilities in mobile edge networks is a promising solution to cope with the challenging capacity and delay requirements imposed on future mobile communication systems. The problem of optimal facility placement in mobile edge networks has not been fully studied in the literature. This is a non-trivial problem because the mobile edge network has a unidirectional topology, making existing solutions inapplicable. This paper considers the problem of optimal placement of a fixed number of facilities in a mobile edge network with an arbitrary tree topology and an arbitrary demand distribution. A low-complexity sequential algorithm is proposed and proved to be convergent and optimal in some cases. The complexity of the algorithm is shown to be $O(H^2{\gamma})$, where H is the height of the tree and ${\gamma}$ is the number of facilities. Simulation results confirm that the proposed algorithm is effective in producing near-optimal solutions.

A Study on Efficient Operation of Cosmetic Wastewater Treatment Facility (화장품 폐수처리시설의 효율제고를 위한 처리비 영향인자에 관한 연구)

  • 장명옥;조춘구
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.25 no.1
    • /
    • pp.89-106
    • /
    • 1999
  • This research was undertaken to manage the waste treatment facility in cosmetic plants more effectively, The discharge and the treatment of pollutant in cosmetic plants were analyzed. And several factors which had an influential effect of the treatment cost, were found out. Effective management methods are proposed. Since average operating rate is estimated from 29% to 56%, the facility has an 44% to 71% surplus capacity. The pollutant removal rate influences highly on the treatment cost. The amount of MLSS is the factor that effects the removal rate. Chemical cost and the amount of the sludge are the influencing factors. To reduce the waste water treatment cost,-the saving of SV3O use and the management of MLSS amount are essential.

  • PDF

Simulation Analysis for Multiple-Server Queueing Model with Advertising and Balking (선전과 이탈이 있는 복수 서비스 대기행렬모형에 대한 시뮬레이션 분석)

  • 권치명;김성연;정문상;황성원
    • Journal of the Korea Society for Simulation
    • /
    • v.13 no.1
    • /
    • pp.41-50
    • /
    • 2004
  • The purpose of this paper is to analyse the manager's policy to maximize the profit in a multiple-server queueing facility with a limited queue capacity. We assume that the level of advertizing effects on the arrival rate of customers to the facility. The model without ‘word of mouth effect’ is assumed that the arrival rate is independent on the qualify of service level. We estimate the service quality by the balking rate of customers from system. We extend this to the model with ‘word of mouth effect’. To achieve the maximum profit, the most important factor is the considerably high utilization of facility for both models. Given service rate, we should maintain an effective arrival rate to some extent. To this end, among the available options, an increase of advertizing effort is more desirable than reducing the fee if the service value of customers remains unchanged. We also investigate whether the variability of service time has a significant impact on determining the optimal policy. The cost of service variability is not so expensive as that in a single server model due to the reduced variability of service times in a multiple-server model.

  • PDF

Neutron dose rate analysis of the new CONSTOR® storage cask for the RBMK-1500 spent nuclear fuel

  • Narkunas, Ernestas;Smaizys, Arturas;Poskas, Povilas;Naumov, Valerij;Ekaterinichev, Dmitrij
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.1869-1877
    • /
    • 2021
  • This paper presents the neutron dose rate analysis of the new CONSTOR® RBMK-1500/M2 storage cask intended for the spent nuclear fuel storage at Ignalina Nuclear Power Plant in Lithuania. These casks are designed to be stored in a new "closed" type interim storage facility, with the capacity to store up to 202 CONSTOR® RBMK-1500/M2 casks. In 2016 y, the "hot trials" of this new facility were conducted and 10 CONSTOR® RBMK-1500/M2 casks loaded with the spent nuclear fuel were transported to the dedicated storage places in this facility. During "hot trials", the dose rate measurements of the CONSTOR® RBMK-1500/M2 casks were performed as the dose rate is one of the critical parameter to control and it must be below design (and safety) criteria. Therefore, having the actual data of the spent nuclear fuel characteristics, the neutron dose rate modeling of the CONSTOR® RBMK-1500/M2 cask loaded with this particular fuel was also performed. Neutron dose rate modeling was performed using MCNP 5 computer code with very detailed geometrical representation of the cask and the fuel. The obtained modeling results were compared with the measurement results and it was revealed, that modeling results are generally in good agreement with the measurements.

Study on the Operation and Improvement of Excretory Treatment Facilities: Focusing on the case of Seoul City (분뇨처리시설 운영 및 개선 연구: 서울시를 중심으로)

  • Lee, Jang-Hown;Shin, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.30 no.4
    • /
    • pp.123-130
    • /
    • 2022
  • This study was conducted to prepare a plan for the operation and improvement of excretory treatment facilities in Seoul, where the amount of excrement is expected to continue to increase due to the increase in the installation of septic tanks, a private sewage treatment facility. As a result, there are problems due to the lack of treatment capacity and increase in the amount brought in. To improve this, it is necessary to expand the overall excretory treatment facility, adjust the area of some facilities, reduce the amount of excrement through the realization of excretory units, and reduce the amount of excrement due to the change of the type of sewage treatment facility.

Conceptual Design of Interim Storage Facility for PWR Spent Nuclear Fuel (경수로 사용후핵연료 중간저장시설 개념(안) 수립)

  • Hyun-goo Kang;Chang-min Shin;Sang-Hwan Lee;Tae-Chul Moon
    • Journal of Radiation Industry
    • /
    • v.18 no.3
    • /
    • pp.255-266
    • /
    • 2024
  • The uranium nuclear fuel used in nuclear power generation needs to be replaced with new fuel after a certain period. In South Korea, the spent nuclear fuel generated during this process is temporarily stored within the nuclear power plant site, and there are ongoing issues with the saturation of storage capacity. To address these problems, the South Korea government has established a plan to manage high-level radioactive waste, including provisions for securing interim storage facilities. An interim storage facility is designed to safely store spent nuclear fuel for certain period before its permanent disposal. This study analyzed leading international cases of interim storage facilities that are technically feasible and can reduce the operating period of temporary storage facilities for spent nuclear fuel within nuclear power plant sites. It also presented the technical concepts required for the operation of interim storage facilities for spent fuel from PWR(Pressurized Water Reactor), reflecting the situation in South Korea.

Generation and Characteristics Analysis of Swine Manure for Introducing Biogas System (논문 - 바이오가스화 도입을 위한 양돈농가 가축분뇨 발생 및 특성분석)

  • Choi, Eun-Hee;Yoon, Young-Man;Kim, Chang-Hyun
    • KCID journal
    • /
    • v.18 no.2
    • /
    • pp.25-32
    • /
    • 2011
  • The 21 livestock farms considering future installation of biogas systems were studied. These farms were examined how to raise the livestock, to treat manure, to operate facility with respect to manure characteristics. The 15 farms out of 21 farms have applied to the marine dumping and consignment treatment for treating manure and even farms which have equipped liquid fertilizing system have less capacity facility than legal standards. Characteristics of manure were affected by the scale of swine barn, clean water usage, frequency of cleaning, cleaning method, feces-urine separating method, etc. Retention time in storage (over 20 days) has resulted in lower concentration of organic matter which could reduce biogas production. This indicates that systematic barn management system is required. Inhibition tests showed that disinfectant and citric acid did not affected digestion rates at 10 times higher concentration than recommendation. However hypochlorous acid is likely to affect the anaerobic microbial activity.

  • PDF