• Title/Summary/Keyword: Facility Capacity

Search Result 627, Processing Time 0.024 seconds

공력가열 시험설비 설계

  • Ok, Ho-Nam;Kim, In-Sun;Ra, Seung-Ho;Kim, Seong-Lyong;Cho, Gwang-Rae
    • Aerospace Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.155-169
    • /
    • 2004
  • Space launch vehicles and reentry vehicles are exposed to extreme heating conditions due to high aerodynamic heating while flying at high Mach numbers in the atmosphere. To protect the vehicle itself or the payload from the aerodynamic heating, the thermal load imposed on the surface should be exactly predicted and proper thermal protection should be applied based on the prediction results. But this requires rigorous thermal analysis and testing to prevent loss of payload capacity caused by excessive heat shielding, and the amount of thermal protection material to be applied is determined through aerodynamic heating tests. Various design points to be considered to upgrade the prototype aerodynamic thermal simulation facility(ATSF) used for the KSR-series sounding rocket development to the one suitable for the KSLV(Korean Space Launch Vehicle)-series launch vehicle are considered in this research. The need and limitation for the facility are first considered, and the functions required for KSLV testing are determined. The specifications of the upgraded facility are briefly suggested and these results will be used for the future fabrication and installation of the facility.

  • PDF

A Study on the Efficiency of Children's Shelter in Korea using DEA Analysis Method

  • Jeong, Seong-Bae;Joo, Mi-yeon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.6
    • /
    • pp.207-217
    • /
    • 2020
  • The purpose of this study is to analyze the efficiency of Korean child welfare facilities using the DEA analysis method and to present policies. The input variables for the analysis of this data were the number of employees, the number of facilities, and the number of gardens, and the output variables were the current sources. The results of the study are as follows. As a result of CCR analysis, inefficient facilities were found to be temporary protection facilities and comprehensive facilities. As a result of BCC analysis, inefficient facilities were identified as temporary protection facilities. As a result of SE analysis, inefficient facilities were found to be temporary protection facilities. The suggestion is as follows. First, adjustment of the capacity of temporary protection facilities is required. Second, it is necessary to strengthen the professionalism of workers in child welfare facilities. Third, strengthen the expertise of the child welfare facility manager.

Study on the Estimation Method of Safely Index for Community Disaster (지역안전도 진단 방법 개선에 관한 연구)

  • Jang, Dae-Won;Jeong, Sang-Man;Park, Moo-Jong;Kim, Hung-Soo;Seoh, Byung-Ha
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.5
    • /
    • pp.119-127
    • /
    • 2007
  • We reconstructed the community disaster risk and patterns of damage magnitude using 'Annual Report of National Disaster Data'. And we developed the inspection index for damage reduction capacity of each facility or each damage prevention measure. The inspection indices include climatic and hydrological vulnerabilities, and disaster probability components. Also we considered all indices and components for DB construction on the GIS system. Then we constructed 'Inspection for Safety Degree of Community System(ISDCS)' according to the facility's criteria from the combination of damage reduction capacity of facility and damage magnitude. The safety index has designed a system that encourages communities to carry out a list of activities in the raw from natural disaster. The activities ultimately saves lives, reduce property damage, and protect disaster facilities. Damage patterns were also analyzed according to damage type using pattern analysis and GIS.

Current and Future Foodservice Management Performance in Child-care Centers (영유아 보육시설의 급식 관리 실태 및 개선방안)

  • Chang, Hye-Ja;Park, Young-Ju;Ko, Eun-Seon
    • Journal of the Korean Dietetic Association
    • /
    • v.14 no.3
    • /
    • pp.229-242
    • /
    • 2008
  • This study examined foodservice management performance in child-care centers and suggests ways in which meal service quality can be improved. Questionnaires were distributed to 51 child-care facilities. The majority of respondents were facility directors (dietitians) and their facility type was tax-paid (92.2%). The dietitian response rate was 51.0%, and the majority (96.2%) were hired with co-management status, visiting a facility once a week (76.0%). Only 52.1% of the facilities had menu planning by a dietitian, and improvements were needed in terms of planning menus with standardized recipes, especially for infant meals. The monthly food cost per child was 47,394 won, and the labor cost for a co-management dietitian was 3,670 won per child, indicating 21.8% and 1.8% of the tuition fee, respectively. Other necessary improvements included: more reliable food purchasing management, securing additional foodservice equipment, and better sanitation management. In addition, respondents rated the following as requirements to ensure high quality meal service: 'modernized foodservice equipment and facilities', 'government financial support', and 'information on nutrition and foodservice management provided by dietitians'. Based on the study results, the following are recommendations for improving meal service quality in child-care centers: Dietitian placement should be extended to facilities of over 50-capacity in addition to their current placement in facilities of over 100-capacity, and co-management dietitians should have their control span restricted to two facilities instead of five. Finally, nationwide nutrition support plans and nutrition education programs should be developed and implemented by dietitians, and their roles should be extended to foodservice mangers as well as nutrition teachers.

  • PDF

Vulnerability Evaluation of Groundwater Well Efficiency and Capacity in Drought Vulnerable Areas (가뭄 취약지역의 관정 효율 및 능력에 대한 취약성평가)

  • Shin, Hyung-jin;Lee, Jae-young;Jo, Sung-mun;Jeon, Sang-min;Kim, Mi-sol;Cha, Sang-sun;Park, Chan-gi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.6
    • /
    • pp.41-53
    • /
    • 2019
  • Recently, the damage caused by climate change has been distinguished in the world. The Korean Peninsula is also suffering from drought, so it is necessary to study the vulnerability assessment to identify and predict the state of the irrigation facility, which is a irrigation facility. As the damage caused by drought is occurring in the Korean peninsula, it is necessary to study the vulnerability assessment to know the condition of the irrigation facility, and to predict it. The target areas were Yeongdong-gun, Cheonan-si, Mungyeong-si, Geochang-gun, Muju-gun, and Yeonggwang-gun. The survey items were selected as positive impacts survey items, including precipitation, groundwater level, and pumping capacity per groundwater well. The negative impacts were selected as the cultivation acreage, Number of days without rain, and the ratio of private underground wells. The survey method was investigated by various methods such as "weather data portal", "groundwater level status information", "agricultural drought management system", "groundwater survey yearbook". The results of vulnerability assessment were expressed by the score by conducting survey and standardization. As a result, Yeonggwang-gun showed normal vulnerability, and other areas showed "vulnerable" or "very vulnerable".

Study on the Elicitation of Parameter in Designing each Capacity of PV System for Power Industry (전력산업용 PV System의 각 용량별 설계 파라미터 도출에 관한 연구)

  • Kim, ByeongMan;Lee, KilSong;Yang, YeonWon;Shin, HyunWoo;Kim, EuiHwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.78.1-78.1
    • /
    • 2010
  • Recently, as much supplied with new-renewable energy, as much invested in PV system. PV system consists of PV module, PCS and Monitering system, and also could be classified into the type and the capacity by installation method and cost etc. When various systems are installed in the field, it is needed to research for applying in the field and establish infrastructure in order to ensure stable efficiency and reliability. In this study, as the basic design of the demonstration test facility, it is designed the basic PV systems for each capacity to test each PCS. In addition, It is drew the climatic conditions such as insolation, temperature and the design parameters such as installation angle, shades for the local demonstration project and expected the generation of each PV system.

  • PDF

Securing Operation Margin Capacity as Coordination Control among the Power Compensation Equipments (전력보상설비의 상호 협조제어에 따른 운영여유용량의 확보)

  • Lee, Sang-Deok;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.6
    • /
    • pp.1011-1016
    • /
    • 2010
  • It is an important issue to electric power system operations that it can reliably supply large-capacity power to consumption area as due to increasing power demand growth. For this purpose, The FACTS equipment based on Power IT technology with the existing mechanical compensators has been applied to power system. Therefore we suggest on this paper that a plan for coordination control of multiple power compensation equipment in order to increase the utilization of each facility and secure operation margin capacity. As the result of simulation, it is possible to cope actively with a suddenly changed power system. This helps greatly for the voltage stability and supply reliability in a suddenly changed power system.

A Cut Generation Method for the (0, 1)-Knapsack Problem with a Variable Capacity (용량이 변화하는 (0, 1)-배낭문제에 대한 절단평면 생성방안)

  • 이경식;박성수
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.25 no.3
    • /
    • pp.1-15
    • /
    • 2000
  • In this paper, we propose a practical cut generation method based on the Chvatal-Gomory procedure for the (0, 1)-Knapsack problem with a variable capacity. For a given set N of n items each of which has a positive integral weight and a facility of positive integral capacity, a feasible solution of the problem is defined as a subset S of N along with the number of facilities that can satisfy the sum of weights of all the items in S. We first derive a class of valid inequalities for the problem using Chvatal-Gomory procedure, then analyze the associated separation problem. Based on the results, we develop an affective cut generation method. We then analyze the theoretical strength of the inequalities which can be generated by the proposed cut generation method. Preliminary computational results are also presented which show the effectiveness of the proposed cut generation method.

  • PDF

Theory vs. Experiment of Static Characteristics of Contrarotating Hydrostatic Journal Bearing with Overhung-Type Loads (외팔형 하중지지 이중 반전 정압 베어링의 정특성 이론 및 실험 연구)

  • 이용복;김창호;권오관;최동훈;이강복
    • Tribology and Lubricants
    • /
    • v.12 no.3
    • /
    • pp.92-99
    • /
    • 1996
  • Energy-efficient contrarotating propeller systems have been recently reviewed as one of alternative means in marine car-carrier applications. Contrarotating rotors preclude the usage of conventional plain journal bearings due to the lack of load carrying capacity. A new multi-recess hydrostatic contrarotating journal beating test facility has been designed and installed to test the static load carrying capacity. Measurements of flow rates and orbits have been investigated by testings on a overhung-type contrarotating rotor system which is supported by a hydrostatic journal bearing. Numerical results of static equilibria were compared with test results. Various contrarotating speed combinations, and supply pressure conditions were selected. The numerical predictions of orbit centers and flow rates are generally accurate.

Effect of Leaf Dehydration Process and Air Flow Capacity of Curing Facility on Physical Properties and Composition of Leaves During Flue-curing (황색종 연초 건조중 탈수경과 및 풍속차가 건조엽의 특성에 미치는 영향)

  • Ryu, Myong-Hyun;Seok, Yeong-Seon;Lee, Un-Chul
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.5 no.2
    • /
    • pp.9-15
    • /
    • 1983
  • The effect of leaf dehydration process and air flow capacity of bulk curing on physical properties and composition of cured leaves was studied, respectively, during flue- curing. Cured leaves from excessive moisture during yellowing stage and those from rapid dehydration Process inevitably during later stages, tend towards lower equilibrium moisture contents, higher shatter index, hither protein nitrogen, and leaf scalding or deterioration of Beaves with redish cast. Early dehydration at the yellowing stage re suited in increasing of p Bamitic, stearic, linoleic, and linolenic acid contents, but showed reduction of brightness difference between upper and lower surface of the cured leaves, Leaf surface lipid decreased with the progress of curing stages, more conspicuously during later stage. Lowering air flow capacity of fan by 50oye during stem drying stage resulted in increasing of leaf surface lipid and 25oye decreasing of electric power consumption , but curing period and kerosene consumption were not affected.

  • PDF