• 제목/요약/키워드: Facilities Standards

검색결과 1,141건 처리시간 0.03초

소부대 전투시설 방호두께 기준의 타당성 검토에 대한 기초 연구 (A Feasibility Study Evaluating Standards for Covered-Positions Built with Concrete Materials)

  • 김석봉;강영철;이필재;백상호;박영준;우즈 폴
    • 한국군사과학기술학회지
    • /
    • 제12권5호
    • /
    • pp.571-576
    • /
    • 2009
  • In terms of protective engineering, there are no noticeable researches regarding covered-positions for smaller units in South Korea. So, standards to maintain and build protective facilities for larger units have been applied in ones for smaller units without any adjustment. The previous study was to calculate penetration depth of the concrete walls because the experiment performed indoor. In this outdoor experiment, velocity of projectile impact as one of the other important factors was considered to prove the validity of 30cm concrete wall thickness as effective protective level of the covered-position. Random effects and extraneous variables which could be occurred in outdoors experiment were controlled with statistical techniques. As a result, velocity of projectile impact was significant variable and the given standard, 30cm thickness of concrete walls was as valid as ever.

초등학교(初等學校) 시설(施設)의 통폐합(統廢合) 기준(基準) 및 유형(類型)에 관한 연구(硏究) (A Study on Unified-Closed Standards and Types of Elementary School)

  • 김승제;원승현
    • 교육시설
    • /
    • 제8권2호
    • /
    • pp.27-40
    • /
    • 2001
  • The opinion on merits and defects caused the unified-closed of a school facilities have collected by a people and government since the unified-closed system was enforced. There is a problem that the data occurring in the middle of the unified-closed is not analized. Therefore, in this study the target is elementary schools in kyung-gi province which did the unified-closed. First, this study is for analysing which condition influenced to make them. Second, it is for understanding the problems occurred in the process of the unified-closed and presenting the direction of improvement. Third, it is for setting up the planned guide by classification of school facility for the unified-closed which considers the previous problems sufficiently. The range of the study treats of general trend and analysis about the unified-closed of elementary school. The core subject is to analyse the standard and classification of the unified-closed of the object school by the policy of the unified-closed and to compare the carried process of the case school.

  • PDF

우리나라 영유아 보육시설의 친환경 실내를 위한 체크리스트와 디자인안 제안 (Checklist and Design Recommendations for the Interiors of Korean, Eco-healthy Childcare Facilities)

  • 천진희
    • KIEAE Journal
    • /
    • 제10권6호
    • /
    • pp.105-114
    • /
    • 2010
  • As children are known to touch and chew everything, green cleaning procedures are an important step in preventing children from ingesting harmful toxins. The objectives of this study are to develop a new, self-evaluation checklist and to suggest design recommendations which comply with easy, adaptable, economical ways to improve the eco-friendly indoor environment of Korean childcare facilities. The information compiled during this study was collected through literature review and internet surveys1) from July, 2009 to February, 2010. The results of this study show that the current Korean childcare accreditation system and practices emphasize clean building interiors, policies for sanitation and cleanliness, and control of humidity and lighting. On the other hand, the information provided by green-building rating systems from GBCC, LEED, and GBTool offers additional and comparative details regarding indoor environment quality and standards regarding the IAQ performance and management plan, ventilation and thermal comfort systems, views from windows, acoustics, and lighting. In conclusion, this document provides an appropriate and easy-to-follow, self-evaluation checklist composed of eight criteria and 51 practical items. This study also provides the design recommendations composed of 27 practical ideas focusing on interior elements. Both the checklist and design recommendations I have suggested can be a post-occupancy tool for evaluating eco-healthy facility standards as well as tips for continuing to maintain eco-healthy childcare facilities.

수·변전설비의 안전 환경 설치에 관한 국내외 규정 비교 분석 (Comparison and Analysis of Domestic and Foreign Standard for Solely Environment Installation of Power Station)

  • 배석명;김한상;방선배;이건호
    • 조명전기설비학회논문지
    • /
    • 제19권5호
    • /
    • pp.45-53
    • /
    • 2005
  • 국내산업의 발달 및 경제 성장과 더불어 전력설비의 대용량화 및 다양한 전기설비의 보급으로 인하여 수변전설 비도 증가되고 있으며 또한 대형화 되어 지고 있는 추세이다. 이러한 수$\cdot$변전설비에서의 안전 및 설비사고도 점차 증가되고 있는 실정이다. 따라서 본 논문에서는 수$\cdot$변전설비의 안전 환경 설치를 연구대상으로 하여 국내외 규정 및 기준에 대하여 비교 하였으며, 이를 통해 수$\cdot$변전설비의 설치시의 문제점을 도출하여 우리나라의 수$\cdot$변전설비 안전 환경 설치에 적용할 수 있도록 관련 규정의 개정(안)을 제시하였다.

방폭설비 성능유지 실태분석을 통한 관리방안 연구 (A Study on the Management Plan through Performance Maintenance Analysis of Explosion-proof Facilities)

  • 권용준;변정환
    • 한국안전학회지
    • /
    • 제35권2호
    • /
    • pp.8-16
    • /
    • 2020
  • In Article 311 of the Regulation on Occupational Safety and Health Standards requires the use of Korean Industrial Standards Act in accordance with the Industrial Standardization Act. However, the classification, inspection, maintenance, design, selection, and installation of explosion hazard locations for explosion and explosion prevention and internalization of 'safety' in the performance maintenance phase of electrical machinery and equipment There is no technical and institutional management plan for remodeling and alteration. Analysis of actual conditions and problems related to the installation, use, and maintenance of explosion-proof equipment, comparative analysis of domestic and international technical standards and systems, technical, institutional and administrative systems and systems related to installation, use, and maintenance of explosion-proof equipment, technical personnel and qualifications, etc. It is to propose legislation, system improvement, and technical standard establishment related to the maintenance of explosion-proof facility performance through improvement of the necessity and feasibility study for establishment of the legal status of the management site and management plan. As technical measures, KS standard revision (draft), KOSHA guide (draft) and explosion-proof facility performance maintenance manual were presented. In addition, the institutional management plan proposed the revised rule on occupational safety and health standards, the revised rule on the restriction of employment of hazardous work, and the manpower training program related to the maintenance of explosion-proof facilities and the qualification plan. Enhance safety at the installation, use, and maintenance stage of explosion-proof structured electrical machinery. It is expected to be used to classify explosion hazards, select related equipment, and to update and standardize standards related to installation, use and maintenance.

철도터널 화재에 대한 정량적 위험도 분석 (Quantitative Risk Analysis for Railway Tunnels)

  • 박정현;심차상
    • 한국철도학회논문집
    • /
    • 제20권3호
    • /
    • pp.400-412
    • /
    • 2017
  • 국내외 철도터널 방재기준들에서 특히 주목할 만한 것은 신속한 대피를 위해 많은 비용이 소요되는 대피통로 설치 기준을 강화 적용하고 있다는 점인데, 국내 기준의 경우 1km 이상 연장의 터널별 QRA 분석을 통해 위험수준에 따라 설치여부를 결정하도록 하고 있으나, QRA 분석에 필요한 화재발생확률, 화재발생 시나리오, 화재규모, 사회적 위험도 평가기준 등에 대한 세부적용기준들이 정립되어 있지 않음으로써 과다설계로 인한 사회적 추가비용이 발생할 수도 있으므로 이에 대한 적정 수준의 기준 정립이 필요하다. 이에 본 연구에서는 관련문헌 조사 분석을 통해 합리적이고 적정한 수준의 세부적용조건들을 선정하여 서로 다른 터널연장을 가진 모델 터널(고속철도용)들에 대한 QRA 분석과 동시에, 중요 대피촉진시설중 하나인 대피통로 미적용 가능한 터널최대연장에 대해 분석하였다. 또한, 현재 호남고속철도 등 터널들에 대한 QRA 결과와 모델 터널의 분석결과를 종합, 피난촉진시설 관련 국내외 기준들과의 비교를 통해 적용기준의 적정성 검토를 수행하였다. 이들 결과들은 향후 안전성과 경제성이 고려된 합리적인 방재계획 수립을 위한 기초자료로써 활용될 수 있을 것으로 기대한다.

화재진압 교육훈련시설 설치기준의 필요성 및 내용에 관한 연구 (A Study on the Necessity and Contents of the Installation Criteria of the Fire Suppression Education & Training Facilities)

  • 송우승;함승희;윤명오
    • 한국화재소방학회논문지
    • /
    • 제28권3호
    • /
    • pp.62-71
    • /
    • 2014
  • 소방인력의 전문성 제고 및 역량 강화를 도모함과 동시에 소방인력의 손실 저감을 위하여 소방교육훈련의 중요성이 부각되고 있으며 동시에 소방교육훈련시설의 확충이 추진 중에 있다. 이에 본 연구에서는 소방교육훈련시설 확충에 있어서 핵심시설이라 할 수 있는 화재진압 교육훈련시설에 대한 국내외 현황 및 설치기준에 대한 비교연구를 통하여 국내 소방교육훈련시설 설치기준의 필요성 및 내용에 관한 기초자료를 제시하고자 하였다. 향후 추진될 화재진압 교육훈련시설의 설치기준은 국제기준과 동등수준의 성능을 담보하는 내용으로 구성하되, 구체적인 훈련목적 및 구조물 최소요구사항을 규정하여야 하며, 이는 훈련 간 훈련생과 교관의 안전을 최우선적으로 고려하여 결정되어야 한다. 또한 소방 표준작전절차 상에 제시된 시나리오의 적극적인 반영을 통하여 훈련 효과성 제고에 주목하여야 하며, 다른 소방교육훈련시설의 설치기준과 상호 유사성 및 호환성을 확보하여 전체 기준의 균형감을 유지해야 한다.

도로연변 환경시설에 의한 교통소음 저감방안에 관한 연구 (A study on Traffic Noise control by the Environmental facilities around Roadway)

  • 설증민;정용
    • 환경위생공학
    • /
    • 제3권2호
    • /
    • pp.43-60
    • /
    • 1988
  • This study was carried out to determine traffic noise level and analyze noise reduction effects of various sound protection facilities in the area of Seoul, Inch'on, Songchoo and Seoul- Busan Expressway from March to Octover, 1987. The results were as follows; 1. As compared with the environmental standards and the traffic noise level in heavy noise areas, traffic noise levels observed were shown in higher than environmental standards. The noise levels in Seoul were determined at 12.8-18.2 dB(A) in daytime and 19.0-26.9 dB (A) in nighttime. And incase of inch'on, it were 6.7-9.6 dB(A) in daytime, 7.9-18.9 dB(A) in nighttime, respectively. 2. The environmental noise level observed in the backside of protection facilities, such as apartment, soundproof barrier and houses, which were constructed in paralled to the road was lower about 3-5 dB(A) than perpendicular to theroad. Noise recuction effect of upper stairs in apartment was higher than lower stairs. 3. The predicted noise level obtained from the equation $({\triangle}L\;=\; -10\;log\;(^{I'1}/Ii)\;was\;\pm\;1dB$ (A) and the correlation coefficient (r) was 0.923. 4. The noise reduction effect in backside of apartment was measured at on sites and predicted by total noise loss equation. The predicted noise level was 60.9 dB(A) and the measured level was 60.6 dB(A), respectively. 5. The narrow width landscape less than 10m width was almost no effect for the protection of traffic noise. According to the synthesis of the above results, the noise level of the road was exceeding mostly the environmental standard in the heavy traffic areas. The counterplan should be set as well. The insulation of noise protection facilities were effective by the location with near distance from the road edge. The reduction effect of double window in apartment was represented so much. The prediction model could be applied to estimate the noise levels in the roadside as well as the effectiveness for the noise protection facilities.

  • PDF