• Title/Summary/Keyword: Facilities Standards

Search Result 1,133, Processing Time 0.025 seconds

Improvement plan for the standard for calculating the height of the stair railing for Barrier Free (BF) certification system (장애물 없는 생활환경(BF) 인증제도 계단 난간 높이 산정기준 개선안)

  • Lee, Sang-Soo;Bang, Hong-Soon;Kim, Ok-Kyue
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.218-219
    • /
    • 2022
  • Among the Barrier Free (BF) certification evaluation items for public facilities, at which position the standard for the effective height of the stair railing handle should be calculated is not clearly determined. Because of this, not only the evaluation standards of the certification authority and the evaluation committee are different, but disputes are occurring between the ordering organization, the design company, and the construction company. Therefore, the stair railing installation standard laws for public facilities were analyzed and through a case study of institutions that obtained the BF certification, problems were analyzed. The results of problem analysis reveal the following. 1) The standards of the Ministry of Health and Welfare and the Ministry of Land, Infrastructure, and Transport were different. 2) The effective height calculation standard was ambiguous, and disputes occurred frequently. To solve this problem, we proposed improvement plans for calculating the height of the stair railing that can comply with laws while ensuring safety.

  • PDF

The Reinforcement Plan of Safety Management for the Small-sized Facility (소규모 시설물의 안전관리 강화방안)

  • Jung, In Su
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.111-118
    • /
    • 2014
  • While large-sized facilities (type I II) have been managed systematically after the establishment of the Special Law for Safety Management on Facility, the management of small-sized facilities is relatively poor. The small-sized facilities have been managed by The Basic Law for Disaster and Safety Management, however, it is hard to manage them systematically as related standards are not established. Therefore, this study proposed the management plans for including the facilities such as some road tunnels and utility tunnels, which have the definite manager and a high possibility to harm the public, into type I and II facilities. In addition, it proposed the reinforcement plans of safety management for small-sized and vulnerable facilities such as breast wall and cut slopes, traditional markets and pedestrian bridges, which are fundamental facilities closely related to people's life, although a budget and a man-power are not enough.

A Study on Industrial Site Annexed Parking Unit Calculation Method by Considering Facility Use and Scale Characteristics (용도 및 규모특성을 고려한 산업단지 공장시설의 부설주차장 설치기준 개선방안 연구)

  • Ahn, Woo-Young;Lee, Seon-Ha
    • International Journal of Highway Engineering
    • /
    • v.12 no.2
    • /
    • pp.129-136
    • /
    • 2010
  • The present annexed parking lot standards for buildings in Parking Act are categorized in 9 groups in terms of recreation, culture and assembly, housing, factory, and so on, in which same grouped facilities have uniform parking standards. The local governments have authority to itemize groups and adjust parking standards within ${\pm}50%$ ranges. These days diversity in building types and functions need more fractionated parking standards; however, most local governments focusing merely on applying strengthened parking standards in general without systematic rules of consistency. The current problem of parking standards being used is lack of regarding facility characteristics; expecially, a large sized high-tech manufacturing facility located in industrial site is still applied by same parking standards as normal manufacturing facility, even though most part of manufacturing process is automated and hence less manpower is employed. This paper presents a systematic method of analyzing parking generation unit for factory facilities in industrial site in terms of facility use and scale characteristics.

System Development and Field Application for Measuring installation Interval and Height of Road safety Facilities Using a tine Scanning Camera (라인스캔 카메라를 이용한 도로 안전시설 설치간격 및 높이측정 시스템 개발 및 현장적용)

  • Moon, Hyung-Chul;Suh, Young-Chan
    • International Journal of Highway Engineering
    • /
    • v.10 no.3
    • /
    • pp.231-237
    • /
    • 2008
  • One of the basic requirements for the most advanced countries would be the well-planned traffic infrastructures. For such traffic safety systems, foreign countries follow the current tendency to which they manage the traffic facilities and equipments based on the objective assessment for the state of every traffic safety facility in terms of Asset Management(AM). As the road safety facilities related among them are very diverse, and their functions are very important as well, the regulations and directions for installing them are enacted. However, despite the standards and directions for the installations, sometimes, the facilities are not installed in accordance with the standards, not only causing inconvenience to the users but also negatively affecting the safety for them. In the study, for the facilities in which the installation interval and height are standardized according to the designed speed and geometrical structure of the road among the various road safety facilities, the image analysis model capable of measuring them with a line scanning camera was developed. In addition, the program systematically analyzing this was also developed and applied to the field and, as the result of that, the size and installation interval of the facilities could be measured fast and accurately.

  • PDF

A Study to Set up Guideline for Public Facilities as Infrastructure of Low-rise Residential Community in Seoul (서울 저층주거 밀집지역 공공생활지원시설 설정방향에 관한 연구)

  • Shin, Jee-Hun;Lee, Na-Rae;Kim, Jong-Pil;Kim, Donyun
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.2
    • /
    • pp.127-137
    • /
    • 2019
  • Low-rise residential community is the most popular type (51%) of residential neighborhoods in Seoul. Currently, there is a shortage of public facilities needed for living conditions and the quality of life in low-rise residential areas. This study defines 'public facility' as infrastructure to improve the living environment and used by residents jointly in low-rise residential areas. In this regard, this study analyzes current legal and institutional standards, latest trends in public facility of apartments, and residents' demand and satisfaction level in order to find out the criteria for installation of priority public facilities. As a result, the essential facility basically conforms to the number of household which is the standard of the facility supply in apartment. However, considering the limitations on the accessibility due to low density, it should consider two standards at the same time: the number of household and distance (radius of neighborhood). In conclusion, it is necessary to install legally prescribed facilities according to the number of household and distance: 500 households facilities in 250m radius neighborhood and 1,000 households facilities in 400m radius neighborhood. Also, considering the reality of low-rise residential area, it is necessary to integrate some facilities that can be functionally linked to improve level of utility and efficiency of operation and management. It is expected that the output of this study can be applied to institutionalize of the legal basis for the public facility of low-rise residential community.

A Study on Supplement of Harbour and Fishery Design Criteria through the Statistical Characteristics Analysis of Cruise Ship's Specification (크루즈선 주요 제원분석을 통한 항만 및 어항설계기준 개선 연구)

  • Cho, Ik-Soon;Cho, Jang-Won
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.6
    • /
    • pp.652-660
    • /
    • 2017
  • Recently, the number of tourists using cruise ships in Korea is increasing. and an big cruise ship with an gross tonnage of 160,000 tons or more has entered the domestic ports. Therefore, the government has been making a lot of efforts to confirm the cruise infrastructure for revitalization of the domestic cruise industry. However, there are no standards for cruise ship specifications and water facilities in the domestic port and fishery design standards. Currently, construction of dedicated cruise facilities is under way in major domestic ports. However, due to lack of specifications and domestic standards for cruise ships, it is difficult to design and license special facilities. Therefore, in this study, PIANC rule and domestic harbor and designing standard of fishing port were compared and analyzed in order to present the standard specification of cruise ships. And analyzed the representative linearity of cruises currently being operated. As a result of the ship characteristics analysis, There was a difference in coastal passenger ship in specifications and ship maneuverability. Therefore, in order to design facilities dedicated to cruising, the specifications of the target ship must be included in the domestic design standard. In addition, in order to calculate the scope of the target ship, I applied the coverage rate of 75% to the average specification value of the cruise ship and presented the standards of the cruise ship and the standard of the water area facilities.

Analysis and Evaluation of Life SOC in Boeun-gun According to Minimum Criterion of Basic Life Infrastructures (기초생활인프라 최저기준에 따른 보은군의 생활인프라 시설 충족도 분석 및 유형화)

  • Yang, Seunghwan;Lee, Byungjun;Yoon, Seongsoo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.3
    • /
    • pp.15-27
    • /
    • 2020
  • Living infrastructure facilities are concentrated in cities with high population density, it is necessary to supply basic living infrastructure facilities to promote welfare in rural areas. The establishment of basic living infrastructure is the minimum right for daily living of local residents. It is supplied by considering national economic and social characteristics through national minimum standards, but it is limited to be practically applied to rural areas where many villages are dispersed in large areas. There is a situation. Therefore, it is necessary to supply systematic and quantitative facilities by analyzing villages that do not meet the minimum standards of basic living infrastructure in rural areas and by considering their characteristics. The purpose of this study is to identify the basic living infrastructure facilities of village units and analyze the characteristics of each village for Boeun-gun, Chungcheongbuk-do.

A study on odor and ventilation in waste treatment facilities (폐기물 처리시설에서의 악취 및 환기에 관한 연구)

  • Seo, Byung-Suk;Jeon, Yong-Han
    • Design & Manufacturing
    • /
    • v.14 no.2
    • /
    • pp.28-33
    • /
    • 2020
  • Recently, as the income level and quality of life have improved, the desire for a pleasant environment has increased, and a deodorization plan is required through thorough prevention and diffusion of odorous substances in waste treatment facilities recognized as hateful facilities, appropriate collection, and selection of the right prevention facilities. In this study, a waste disposal facility was modeled and computerized analysis for odor and ventilation analysis was conducted. Numerical analysis of the waste treatment facility was performed at the size of the actual plant. CATIA V5 R16 for numerical model generation and ANSYS FLUENT V.13 for general purpose flow analysis were used as analysis tools. The average air-age of the internal was 329 seconds, and the air-flow velocity was 0.384m/s. The odor diffusion analysis inside the underground pump room showed congestion-free air circulation through streamline distribution and air-age distribution. This satisfies the ASHRAE criteria. In addition, the results of diffusion analysis of odorous substances such as ammonia, hydrogen sulfide, methyl mercaptan and dimethyl sulfide were all expected to satisfy the regulatory standards. Particularly in the case of the waste loading area, the air-flow velocity was 0.297m/s, and the result of meeting the regulatory standards with 0.167ppm of ammonia, 0.00548ppm of hydrogen sulfide, 0.003ppm of methyl mercaptan, and 0.003ppm of dimethyl sulfide was found.

Study on efficient financial income elderly long-term care facilities size

  • Jeong, Seong-Bae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.10
    • /
    • pp.157-166
    • /
    • 2016
  • The aims of this study are to contribute to efficient revenue management by analysis of the scale in elderly long-term care facilities. The data was used for input of the elderly long-term care costs Scale, and calculated the staffing standards and social welfare facilities workers with living wage guidelines in the Department of Health and Human Services. Revenue efficiency is the highest order of size are as follows. I8(98 people) \43,517,010, H6(86 people) \36,568,332, G8(78 people) \29,426,532, F8(68 people) \23,227,532, E8(58 people) \19,701,254, D8(48 people) \19,155,187, C6( 36) \14,389,109, B8(28 people) \9,920,031, A8(18 people) \3,721,031. It seems that its revenue efficiency even higher than the larger the scale. Meanwhile, The researchers focused on C6 (36 patients) model. Suggestion of this study are following; First, the arrangement can be provided based on needs of the elderly care facility staffing standards. Secondly, an elderly care facility selected wage guidelines. Thirdly, the elderly efficiency guidelines established by the size of a nursing facility. This study and other financial income factor are not the applicable limits.

A Study of improvement on Special School for the Mentally Disabled - Focused on Special Schools in Gwnagju - (정신적 장애인을 위한 특수학교 편의시설의 개선방안에 대한 연구 - 광주지역 특수학교를 중심으로 -)

  • Jeong, Hun;Kang, Man Ho;Choi, Ik Suk;Choi, Jae Young;Yoo, U Sang
    • KIEAE Journal
    • /
    • v.12 no.2
    • /
    • pp.45-52
    • /
    • 2012
  • In recent years, the growing needs and the interest of the welfare for the disabled people has ignited the educational facilities for the disabled in Korea. This special schools are to be provide the disabled people with proper facilities to provide opportunities to participate in social life and to maximize the educational efficiency. However many special schools are not properly designed to educate the disabled because their design guidelines including legal planning standards. It is also true that these standards are not specifically categorized and specialized according to the kinds of disability. This study, therefore aims to suggest measures of the special school design guidelines especially for the mentally disabled people. The study first looks after the characteristics of the mental disability and the current situations of special schools in Gwangju. It, then examines the behavilr of the mentally disabled students in some of special schools in Gwnagju through observation and interview. The interview has done with the staff in the facilities regarding the usage patterns and behavioral characteristics of the mentally disabled students especially in convenience facilities in schools.