• 제목/요약/키워드: Facade noise

검색결과 21건 처리시간 0.028초

RLS-90 및 CRTN 모델에 의한 도로 인접건물에서의 도로소음 영향 예측 및 고찰 (Prediction and Evaluation of the Road Traffic Noise according to the Conditions of Road-side Building Using RLS-90 and CRTN Model)

  • 이장욱;김명준
    • 한국소음진동공학회논문집
    • /
    • 제19권4호
    • /
    • pp.425-432
    • /
    • 2009
  • Recently, reduction of road traffic noise in residential buildings has become one of the most important subjects. To reduce the road traffic noise, noise impact assessment by the road traffic prediction model is required before building construction. For reasonable road traffic noise prediction, it is required to analysis of various factors in road traffic prediction models. This paper was studied the road traffic noise propagation factors such as distance from road to building, receiver height, alignment angle of building and reflection coefficient of the building facade by two calculation models, RLS-90 and CRTN. The result showed that noise reduction was generally higher at bottom stories by ground absorption effect. The reflection coefficient of the building facade was affect of additional sound pressure level by facade reflecting. And alignment angle of building at $90^{\circ}$ was performed effective noise reduction better than $0^{\circ}$.

노이즈맵핑을 활용한 도로변 아파트단지의 세대외부소음 및 옥외지면소음 특성 분석 (Analysis of Building Facade Noise and Ground Noise in a Roadside Apartment Complex through Noise Mapping)

  • 신혜경;김명준
    • 한국소음진동공학회논문집
    • /
    • 제25권4호
    • /
    • pp.275-283
    • /
    • 2015
  • The aim of this study is to estimate the noise exposure of roadside apartment complex according to the characteristics of apartment complex. The facade noise level of residential buildings and the ground noise level inside apartment complexes were predicted and analyzed using noise mapping based on a computerized noise model. In addition, the correlation analysis between these noise levels and the characteristics of apartment complex such as traffic volume, building coverage, the number of adjacent roads, etc. was done in a total of 21 apartment complexes. The results showed that building facade noise level and ground noise level were positively correlated with traffic volume (correlation coefficient, r=0.616~0.623) and the number of adjacent roads (r=0.340~0.496). On the other hand, they were negatively correlated with building coverage (r=-0.413~-0.477) and complex area per the number of roads (r=-0.478~-0.615).

한국의 주거형태에 따른 소음노출인구 산정방법 (Assessment Method of Noise Exposed Population for Korean House types)

  • 박인선;김지윤;변기인;박상규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.1057-1061
    • /
    • 2007
  • Noise maps can be widely used to estimate the effect of various kinds of existing noise on people and to predict the future noise situation resulting from urban development projects, etc. In particular, countermeasure for the noise can be considered more effectively by using assessment methods of noise exposed population for specific noise levels, areas, and building types which are the main input factors in noise maps. In this study, effective assessment method of noise exposed population is presented by manufacturing facade noise maps depending on Korean house types.

  • PDF

공동주택 소음예측 방법에 관한 연구 (Study on the efficient noise prediction for an apartment house)

  • 고준희;김동준;박수진;장서일;조만희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.505-509
    • /
    • 2008
  • This paper studied the efficient noise prediction method for new apartment house near the road traffic noise. Three noise prediction software were compared by each prediction noise level using the simple model which is included the road, soundproofing wall and building. Two foreign national calculation models(RLS-90 and NMPB) were verified by comparison of measured sound level. Frequency of sound level was predicted by NMPB and compared by measured data. The sphere of noise source and facade reflection were proposed to accurate predict the road traffic noise in new apartment house.

  • PDF

이중외피시스템의 차음성능 평가에 관한 연구 -전면형 이중외피시스템을 중심으로- (A Study on the Evaluation of Sound Insulation Performance of Double Skin Facade -Focus on the Multi-story type of Double Skin Facade-)

  • 석호태;차민철
    • 한국주거학회논문집
    • /
    • 제15권2호
    • /
    • pp.11-18
    • /
    • 2004
  • The purpose of this study is to evaluate the sound insulation performance and present fundamental data for sound insulation plan about open and close windows of inner facade and outer facade of Double-skin Facade system applied to multi-story type. The Headquarter of Green Building and the Energy Saving Building in the Korea Institute of Energy Research was selected for experiment. Measurement method which are specified in the Korea Standard 2235 were selected for this study. As the result of this study, 1) Sound insulation performance of Multi-layer type of Double-skin Facades is very excellent about outdoor noise. 2) Vertical level is higher, it shows that more decreases sound pressure level.

공동주택의 층별 도로교통 소음의 전달 특성에 관한 연구 (A Study on the Floor-Specific Characteristics of Road Traffic Noise in Apartment Buildings)

  • 함진식
    • 한국주거학회논문집
    • /
    • 제19권1호
    • /
    • pp.1-8
    • /
    • 2008
  • This study is an attempt to understand the floor-specific characteristics of facade road traffic noise in apartment buildings. For this purpose, it sampled a total of seven roadside apartment building complexes: three with no soundproof bar barrier installed at roadside, one with a forest buffer zone, one with a sound-absorbing hill, and two with soundproof barriers. The measured noise level was highest on the 5th floor of apartment buildings with no soundproof barrier, and the upper stories from the 5th floor showed lower-noise measurements in order. For apartment buildings with soundproof barriers, however, the noise level was lower on the 10th floor than the 5th floor. Two apartment building groups--one with a sound-absorbing hill and the other with no soundproof barrier--showed similar measurement results in the floor-specific characteristics of facade road traffic noise. This suggests that such installations have little sound insulation effect. In the apartment building complex with a forest buffer zone around it, a slight sound insulation effect was measured on the lower floors of the buildings.

공동주택 입면 변화에 따른 단지 내 소음특성 (Effects of the Facade of the Buildings on the Sound Characteristics in an Apartment Complex)

  • 김용희;이평직;전진용;이병권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.367-370
    • /
    • 2005
  • This paper investigated the sound characteristics in an apartment complex. The field measurement was conducted in order to examine the acoustical characteristics of the apartment complex in situ. As a result, it shows that there are around 3 sec. reverberation time and the additional sound reinforcements at the area of high height due to the surrounded buildings. Thus, 1:50 Scale model measurement and Raynoise computer simulation were carried out with insertion of the parapet and the canopy on the balcony. In case of a single building, the parapet was effective to reduce noise level at low floor levels, and the canopy was effective to reduce noise level at high floor levels. But it also shows that both the parapet and the canopy were not effective to reduce noise level at middle floor levels. In case of an apartment complex, the canopy was less effective to reduce noise level at each floor in comparison with case of the single building.

  • PDF

Cold facade형 BIPV시스템의 발전성능 분석 (Analysis of Performance of Building Integrated PV System of Cold Facade type)

  • 김현일;강기환;박경은;유권종;서승직
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.275-280
    • /
    • 2008
  • Photovoltaic(PV) permit the on-site production of electricity without concern for fuel supply or environmental adverse effects. The electrical power is produced without noise and little depletion of resources. So BIPV(Building-Integrated Photovoltaic) system have been increased around the world. Hereby the relative installation costs of the system will be relatively low compared to traditional installations of PV in high-rise buildings. This paper examined possibility of BIPV system of cold facade type and analyzed of performance of BIPV system of cold facade type. The system is influenced by conditions such as irradiation, module temperature, shade and architectural component etc. If this BIPV system of 1.1kW is possible the natural ventilation in the summer case, the temperature of PV module decrease and then the efficiency of PV system increase generally. By the results, the annual averaged PR of BIPV system of cold facade type is about 73.1%.

  • PDF