• Title/Summary/Keyword: Fabricated report

Search Result 484, Processing Time 0.027 seconds

Test of the Conduction Cooling System for HTS SMES (고온 초전도 SMES용 전도냉각시스템 특성시험)

  • Yeom, Han-Kil
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.1
    • /
    • pp.62-66
    • /
    • 2008
  • The characteristic of the superconducting magnetic energy storage(SMES) system is faster response, longer life time, more economical, and environment friendly than other uninterruptible power supply(UPS) using battery. So, the SMES system can be used to develop methods for improving power quality where a short interruption of power could lead to a long and costly shutdown. Recently, cryogen free SMES has developed using BSCCO(Bismuth Strontium Calcium Copper Oxide) wire. We fabricated and tested the conduction cooling system for the 600 kJ class HTS SMES. The experiment was accomplished for the simulation coils. The simulation coils were made of aluminium, it is equivalent to thermal mass of 600 kJ HTS SMES coil. The coil is cooled with two GM coolers through the copper conduction bar. In this paper, we report that the test results of cool-down and heat loads characteristics of the simulation coils. The developed conduction cooling system adapted to 600 kJ HTS SMES system and cope with the unexpected sudden heat impact, too.

Fiber-reinforced composite post removal using guided endodontics: a case report

  • Changgi Cho ;Hyo Jin Jo ;Jung-Hong Ha
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.4
    • /
    • pp.50.1-50.8
    • /
    • 2021
  • Although several techniques have been proposed to remove fiber-reinforced composite (FRC) post, no safe and efficient technique has been established. Recently, a guided endodontics technique has been introduced in cases of pulp canal obliteration. This study describes 2 cases of FRC post removal from maxillary anterior teeth using this guided endodontics technique with a dental operating microscope. Optically scanned data set from plaster cast model was superimposed with the data set of cone-beam computed tomography. By implant planning software, the path of a guide drill was selected. Based on them, a customized stent was fabricated and utilized to remove the FRC post. Employing guided endodontics, the FRC post was removed quickly and safely with minimizing the loss of the remaining tooth structure. The guided endodontics was a useful option for FRC post removal.

Fabrication of a custom polyetherketoneketone post-and-core with digital technology

  • Ju-Hyoung Lee;Gyu-Heon Lee
    • Journal of Technologic Dentistry
    • /
    • v.46 no.1
    • /
    • pp.15-19
    • /
    • 2024
  • An ideal post material should have physical properties similar to those of dentin. Post materials with high elastic moduli may cause root fractures. This clinical report describes the treatment of a severely damaged tooth using a recently introduced material. Polyetherketoneketone (PEKK) is a semicrystalline high-performance thermoplastic polymer. PEKK is a promising material for custom post-and-core fabrication because of its elasticity close to that of dentin, good shock absorbance, machinability, and low cost. A laboratory scanner was used to digitize the conventional impression of a severely damaged maxillary right first molar. A custom PEKK post-and-core was designed and milled using computer-aided design and computer-aided manufacturing technology. Using the proposed technique, a custom PEKK post-and-core was fabricated accurately and human error was reduced. Restoration was luted with resin cement. Custom PEKK post-and-core restorations are a viable alternative for treating severely damaged teeth.

FABRICATION OF Nb/Al SUPERCONDUCTING TUNNEL JUNCTION (Nb/Al SUPERCONDUCTING TUNNEL JUNCTION의 제작)

  • Cho, Sung-Ik;Park, Young-Sik;Park, Jang-Hyun;Lee, Yong-Ho;Lee, Sang-Kil;Kim, Sug-Whan;Han, Won-Yong
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.4
    • /
    • pp.481-492
    • /
    • 2004
  • We report the successful fabrication and I-V curve superconductivity test results of the Nb/Al-based superconducting tunnel junctions. STJs with side-lengths of 20, 40, 60 and $80{\mu}m$ were fabricated by deposition of polycrystalline Nb/Al/AlOx/Al/Nb 5-layer thin films incorporated on a 3-inch Si wafer. STJ was designed by $Tanner^{TM}$ L-Edit 8.3 program, and fabricated in SQUID fabrication facility, KRISS. S-layer STJ thin-films were fabricated using UV photolithography, DC magnetron sputtering, Reactive ion etching, and CVD(Chemical Vapor Deposition) techniques. Superconducting state test for STJ was succeeded in 4K with liquid helium cooling system. Their performance indicators such ie energy gap, normal resistance, normal resistivity, dynamic resistance, dynamic resistivity, and quality factor were measured from I-V curve. Fabricated Nb/Al STJ shows $11\%$ higher FWHM energy resolution than genuine Nb STJ.

Fabrication of complete denture using CAD-based vertical dimension increase and monolithic disc: a case report (CAD를 이용한 수직 고경 증가와 monolithic disc를 사용한 총의치 수복 증례)

  • Hyeon, Kim;Woohyung, Jang;Chan, Park;Kwi-Dug, Yun;Hyun-Pil, Lim;Sangwon, Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.242-248
    • /
    • 2022
  • Recently, through the development of CAD/CAM technology, it is also being used for fabricating dentures. Compared to conventional methods, when digital dentures are fabricated, the fabrication process is facilitated, and the number of visits to hospitals is reduced and errors are reduced. In this case, the vertical dimension was increased using a CAD program in a patient who needed vertical dimension recovery due to the use of old dentures, and the final denture was fabricated using a monolithic disc through the milling method. The centric relation was recorded using existing dentures, and using the information from the intraoral scan and the existing denture model scan, a trial denture was fabricated and delivered to the patient to evaluate the midline and occlusion. Based on the evaluation of the trial denture, the final denture was fabricated using a milling method and a monolithic disc, and the final denture showed satisfactory results functionally and aesthetically.

Esthetic removable partial denture with implants and resin clasp: Case report (임플란트와 레진 클래스프를 이용한 심미 가철성 국소의치 증례)

  • Kim, Su-Min;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.58-65
    • /
    • 2015
  • For the rehabilitation of fully edentulous patients, implant-supported removable partial dentures can be considered as one of the treatment options with complete dentures or implant-supported overdentures. If removable partial dentures are used in combination with a small number of implants placed in strategically important positions, it can offer additional stability, retention and support through implants and reduce a burden of surgical procedures compared with fixed implant-supported prostheses with extensive implant placement. Moreover, the economical benefit can be expected as well. The purpose of this case report is to present a treatment in which an implant-supported removable partial denture was fabricated considering residual alveolar bone status and demands after teeth loss in a patient who had been using a distal extension removable partial denture for a long period of time. In anterior area, fixed prostheses were fabricated with implant placement and in posterior area, short implants provide only support for the removable partial denture. In addition, denture base and clasp were made of thermoplastic acrylic resin. Finally, functionally and aesthetically satisfying treatment results can be achieved.

Rehabilitation of the edentulous patient with implant overdenture using CAD-CAM denture system: A case report (CAD-CAM으로 제작된 임플란트 피개의치를 이용한 무치악 환자의 보철 수복 증례)

  • Lee, Han-na;Shim, Ji-Suk;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.374-381
    • /
    • 2022
  • This case report introduces a 74-year-old male patient who visited retention deficiency of the mandibular implant overdenture, which was fabricated 20 years ago. When the existing dentures were used, the vertical dimension was reduced, the maxillary complete denture lacked lip support and retention, and the mandibular overdenture lacked clip retention due to damage to the bar attachment. After removing the damaged bar attachment, it was replaced with a ball attachment, and impressions were taken using the DENTCATM Tray and then the vertical dimension was measured. The gothic arch tracing was performed to record the centric relation. Obtained impressions were scanned and the shape of final dentures was designed using software and try-in dentures were fabricated using 3D printer. After evaluating the occlusal plane, occlusal relationship, facial shape, and pronunciation using the try-in dentures, the bite registration was recorded, and the final denture was manufactured based on this. The inner surface of the denture was adjusted and bilateral balanced occlusion was formed, and the housing was connected to the mandibular denture by a direct method. This case reports have shown satisfactory resultin recovering improved retention and esthetic outcome by increasing the vertical dimension and the lip support using CAD-CAM technique and the ball attachment.

Fabrication of fixed prosthesis by employing functionally generated path technique and dual scan technique in a tardive dyskinesia patient: a case report (지연성 운동이상증 환자에서 functionally generated path 술식과 이중스캔법을 이용한 고정성 보철물 제작: 증례 보고)

  • Shilpa;Du-Hyeong Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.227-233
    • /
    • 2023
  • Tardive dyskinesia is an involuntary neurological movement disorder caused by long-term use of dopamine receptor-blocking drugs leading to dental implications like uncontrolled gnashing and grinding of teeth which in turn imperil the oral rehabilitation procedures as the excessive load increases the risk of prosthesis fracture. A 40-year male with a medical history of tardive dyskinesia visited the hospital to receive oral rehabilitation for missing maxillary anterior teeth. After the oral examination, tooth preparation was done on teeth 13, 15, and 23. After that silicon impression was made and the gypsum cast was digitalized using a desktop scanner and an interim prosthesis was fabricated by milling a resin block. During the try-in, the occlusal one-third of the interim prosthesis was trimmed, and an auto-polymerizing acrylic resin was applied on the occlusal surfaces and inserted in the patient's mouth. Then, the functionally generated path (FGP) of occluding surfaces of opposing arches was traced on the resin surface. When the resin was hardened, the modified interim prosthesis was removed and digitized using an intraoral scanner. The scan image was used in designing the occlusal morphology of definitive prosthesis by modifying the design of the interim prosthesis using the dual scan method. Lastly, a monolithic zirconia prosthesis was fabricated by milling a zirconia block. The definitive prosthesis was delivered reflecting the patient's occlusal scheme. This case report shows that the FGP technique with the dual scan method can help in fabricating fixed prosthesis with harmonious occlusion in a tardive dyskinesia patient.

Full mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and double digital scanning technique: a case report (임시 의치와 이중 디지털 스캐닝 기법을 활용한 전악 고정성 임플란트 수복 증례)

  • Seok-Hyun Shin;Chan-Ik Park;Se-Ha Kang;Ji-Eun Moon;Min-Seok Oh;Chul-Min Park;Woo-Jin Jeon;Seong-Gu Han;Sun-Jae Kim;Su-Jin Choi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.245-256
    • /
    • 2023
  • When restoring with a dental digital system for implant-supported prosthesis, a double digital scanning technique is required: an intraoral scan of the three-dimensional implant location and intraoral scan after placement of temporary denture or provisional prosthesis. During the intraoral scan, the use of scan body as a stable landmark can improve the accuracy of digital impression and simplify laboratory process. In this case, a full-digital system was used to plan and fabricate a custom abutment, provisional prosthesis, and definitive prosthesis. After implant placement, the scan area of the intraoral scan body connected with implant and the intraoral scan body marked on the inside of temporary denture were superimposed. Out of the superimposed files, a custom abutment and provisional prosthesis were fabricated which match the vertical dimension of temporary denture, and definitive prosthesis was fabricated based on provisional prosthesis. We report this case because result has been functionally and esthetically satisfactory by using vertical dimension and central relation set during the fabrication of temporary denture to the definitive prosthesis.

Low Conversion Loss and High Isolation W-band MMIC Mixer Module (낮은 변환 손실 및 높은 격리 특성의 W-band MMIC 믹서 모듈)

  • An, Dan;Rhee, Jin-Koo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.50-54
    • /
    • 2015
  • In this paper, we report on a high performance 94 GHz MMIC mixer module using 0.1-um metamorphic high electron mobility transistors (MHEMTs). A modified resistive mixer with a RF amplifier was proposed in this work for low conversion loss and high LO-RF isolation. The MMIC mixer module was fabricated using a MMIC chip and CPW-waveguide transitions. The fabricated mixer chip and module showed a low conversion loss of 6.3 dB and 9.5 dB, and LO-RF isolations of 24.8 and 30.4 dB at 94 GHz, respectively. This results are superior to those of previously W-band (75-110 GHz) MMIC mixers.