• Title/Summary/Keyword: FTIR(fourier transform infra-red)

검색결과 14건 처리시간 0.021초

Analysis of Surface Tracking of Micro and Nano Size Alumina Filled Silicone Rubber for High Voltage AC Transmission

  • Loganathan, N.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.345-353
    • /
    • 2013
  • This paper discusses the experimental results in an effort to understand the tracking and erosion resistance of the micro and nano size $Al_2O_3$ filled silicone rubber (SIR) material which has been studied under the AC voltages, with ammonium chloride as a contaminant, as per IEC 60587 test procedures. The characteristic changes in the tracking resistance of the micro and nano size filled specimens were analyzed through leakage current measurement and the eroded masses were used to evaluate the relative erosion and tracking resistance of the composites. The fundamental, third and fifth harmonic of the leakage current during the tracking study were analyzed using moving average current technique. It was observed that the harmonic components of leakage current show good correlation with the tracking and erosion resistance of the material. The thermogravimetry-derivative thermo gravimetric (TG-DTG) studies were performed to understand the thermal degradation of the composites. The physical and chemical studies were carried out by using scanning electron microscope (SEM), Energy Dispersive X-ray analysis (EDAX) and Fourier Transform Infra-red (FTIR) Spectroscopy. The obtained result indicated that the performance of nano filled SIR was better than the micro filled SIR material when the % wt. of filler increased.

Electrical Conductivity, Dielectric Behavior and EMI Shielding Effectiveness of Polyaniline-Yttrium Oxide Composites

  • Faisal, Muhammad;Khasim, Syed
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권1호
    • /
    • pp.99-106
    • /
    • 2013
  • Polyaniline-yttrium trioxide (PAni-$Y_2O_3$) composites were synthesized by the in-situ polymerization of aniline in the presence of $Y_2O_3$ The composite formation and structural changes in these composites were investigated by X-ray diffraction (XRD), Fourier transform infra red spectroscopy (FTIR), scanning electron microscopy (SEM) and high resolution transmission electron microscopy (HRTEM). The direct current (DC) electrical conductivity of the order of $0.51{\times}10^{-2}\;S\;cm^{-1}-0.283\;S\;cm^{-1}$ in the temperature range 300 K-473 K indicates semiconducting behavior of the composites. Room temperature AC conductivity and dielectric response of the composites were studied in the frequency range of 10 Hz to 1 MHz. The variation of AC conductivity with frequency obeyed the power law, which decreased with increasing weight percentage (wt %) of $Y_2O_3$. Studies on dielectric properties shows the relaxation contribution coupled by electrode polarization effect. The dielectric constant and dielectric loss in these composites depend on the content of $Y_2O_3$ with a percolation threshold at 20 wt % of $Y_2O_3$ in PAni. Electromagnetic interference shielding effectiveness (EMI SE) of the composites in the frequency range 100 Hz to 2 GHz was in the practically useful range of -12.2 dB to -17.2 dB. The observed electrical and shielding properties were attributed to the interaction of $Y_2O_3$ particles with the PAni molecular chains.

AERI 스펙트럼 분석을 통한 구름에 영향을 받은 스펙트럼 자료 제거 방법 개선 (Improvement of Cloud-data Filtering Method Using Spectrum of AERI)

  • 조준식;구태영;신진호
    • 대한원격탐사학회지
    • /
    • 제31권2호
    • /
    • pp.137-148
    • /
    • 2015
  • 국립기상연구소는 2010년 6월, 하향적외스펙트럼을 관측하는 고분해적외분광간섭계(FT-IR)인 Atmospheric Emitted Radiance Interferometer (AERI)를 안면도 기후변화감시센터에 설치하였다. AERI는 고분해 적외 센서를 탑재하고 있어 위성 기반의 원격탐사 자료를 검증하는데 유효하다. 본 연구에서는 AERI로부터 산출되는 메탄의 품질 향상을 위해 맑을 때의 자료를 분류하는 AERI 스펙트럼 기준의 새로운 방법을 개발하였으며, KLAPS 구름 정보를 이용한 방법과 비교하였다. 맑은 날 관측된 AERI 스펙트럼을 기준 스펙트럼으로 선정하였으며, 구름에 민감한 대기 창 영역을 사용하였다. 임계값 선정을 위해 복사량 임계값 테스트를 실시하였으며, 선정된 임계값을 이용한 AERI 스펙트럼 기준의 방법과 KLAPS 구름 정보를 이용한 방법을 각각 이용하여 최하층 메탄 농도를 산출하였다. 각각 산출된 메탄농도와 지상관측 메탄농도를 비교하였으며, KLAPS 구름 정보를 이용하여 산출된 메탄농도보다 AERI 스펙트럼 기준의 방법으로 산출된 메탄농도의 품질이 더 좋은 것을 확인하였다. 뿐만 아니라 GOSAT 연직 메탄 총량과의 비교에서도 좋은 결과를 보여주었다.

계절별 AERI 기준 스펙트럼 적용을 통한 구름에 영향을 받은 스펙트럼 자료 제거방법 개선 (Application of Seasonal AERI Reference Spectrum for the Improvement of Cloud data Filtering Method)

  • 조준식;구태영;신진호
    • 대한원격탐사학회지
    • /
    • 제31권5호
    • /
    • pp.409-419
    • /
    • 2015
  • 국립기상과학원은 2010년 6월부터, 하향적외스펙트럼을 관측하는 고분해적외분광간섭계(FT-IR)인 Atmospheric Emitted Radiance Interferometer(AERI)를 안면도 기후변화감시센터에 설치하여 운영하고 있다. 고분해 적외 센서를 이용한 AERI는 위성 기반의 원격탐사 자료를 검증하는데 유효하다. 본 연구에서는 계절별 AERI 기준 스펙트럼을 선정 및 적용(Seasonal-Cloud data Filtering Method, S-CFM)하여 구름에 영향을 받은 관측 스펙트럼 자료 제거방법을 개선하였다. S-CFM을 적용하여 산출된 최하층 메탄농도는 한 개의 기준 스펙트럼을 사용(Cloud data Filtering Method, CFM)하여 산출된 최하층 메탄농도 및 지상관측 메탄농도와 비교하였으며, AERI 연직 메탄 총량을 산출하여 GOSAT 메탄 연직 총량을 통해 검증 및 분석하였다. S-CFM 방법을 적용하여 산출된 최하층 메탄농도는 CFM의 최하층 메탄농도보다 더 정확도가 높은 것으로 나타났으며, 지상관측 메탄농도의 연간 변화 패턴과 비슷한 결과를 보였다. 또한 GOSAT과 AERI의 연직 메탄 총량 비교에서도 비슷한 농도 분포를 보였으며, 매년 증가하는 패턴을 보였다. 뿐만 아니라 S-CFM을 적용함으로써 비교 가능한 자료의 개수가 증가하였다. 다만 여름철 AERI 스펙트럼을 통해 산출된 최하층 메탄농도 및 연직 총량 농도가 상당히 과대추정 되는 모습을 보이고 있기 때문에 기술적 보완이 필요한 것으로 나타났다.