• 제목/요약/키워드: FT4

검색결과 1,590건 처리시간 0.026초

등저항성삼축동력계(Isostation B-200)를 이용한 만성 요통 환자들의 요추부 기능 (The Isoinertial Assessment of Lumbar Function in Patients with Chronic Low Back Pain)

  • 배성일
    • 대한물리치료과학회지
    • /
    • 제11권1호
    • /
    • pp.14-19
    • /
    • 2004
  • Objective : This study obtained normative values for variable parameters of lumbar function with the isoinertial triaxial dynamometer in patients with chronic low back pain. Subjects and Methods : 30 patients(male 15, female 15) with chronic low back pain in this study. Variable parameters that were measured with the Isostation B-200 were lumbar range of motion, isometric maximum torques, and maximum velocities in three axis. Results : In patient male group mean R.O.M. was $82.9{\pm}12.5$ degrees in lumbar rotation, $76.5{\pm}17.1$ degrees in lumbar flexion/extension, and $64.3{\pm}14.5$ degrees in lumbar lateral flexion. In patient female group mean R.O.M. was $78.4{\pm}18.5$ degrees in lumbar rotation, $71.7{\pm}20.4$ degrees in lumbar flexion/extension, and $63.2{\pm}14.4$ degrees in lumbar lateral flexion. In patient male group mean isometric maximum torques was $64.7{\pm}23.8ft-lbs$ in lumbar rotation, $81.1{\pm}42.0ft-lbs$ in lumbar flexion, $122.2{\pm}43.6ft-lbs$ in lumbar extension, and $101.0{\pm}37.0ft-lbs$ in lumbar lateral flexion. In patient female group mean isometric maximum torques was $41.9{\pm}9.2ft-lbs$ in lumbar rotation, $49.9{\pm}23.9ft-lbs$ in lumbar flexion, $90.1{\pm}26.8ft-lbs$ in lumbar extension, and $62.0{\pm}16.7ft-lbs$ in lumbar lateral flexion. In patient male group mean maximum velocity of isoinertial exercise with low (25%) resistance was $102.4{\pm}28.8deg/sec$ in lumbar rotation, $108.9{\pm}32.2deg/sec$ in lumbar flexion/extension, and $103.5{\pm}30.4deg/sec$ in lumbar lateral flexion. In patient female group mean maximum velocity of isoinertial exercise with low (25%) resistance was $84.1{\pm}24.4deg/sec$ in lumbar rotation, $93.2{\pm}32.9deg/sec$ in lumbar flexion/extension, and $98.5{\pm}33.7deg/sec$ in lumbar lateral flexion. In patient male group mean maximum velocity of isoinertial exercise with high (50%) resistance was $74.0{\pm}20.9deg/sec$ in lumbar rotation, $98.7{\pm}32.8deg/sec$ in lumbar flexion/extension, and $85.0{\pm}25.8deg/sec$ in lumbar lateral flexion. In patient female group mean maximum velocity of isoinertial exercise with high (50%) resistance was $67.3{\pm}26.4deg/sec$ in lumbar rotation, $82.5{\pm}31.0deg/sec$ in lumbar flexion/extension, and $79.7{\pm}23.9deg/sec$ in lumbar lateral flexion. Conclusion : Maximum isoinertial velocities were more reliable and more significant than isometric maximum torque for the objective assessment of chronic low hack pain.

  • PDF

FT-IR 스펙트럼 데이터의 다변량 통계분석을 이용한 곶감의 원산지 및 품종 식별 (Discrimination of Cultivars and Cultivation Origins from the Sepals of Dry Persimmon Using FT-IR Spectroscopy Combined with Multivariate Analysis)

  • 허설혜;김석원;민병환
    • 한국식품과학회지
    • /
    • 제47권1호
    • /
    • pp.20-26
    • /
    • 2015
  • 본 연구에서는 상업용 곶감의 꽃받침과 종자를 이용하여 대사체 수준에서의 원산지와 품종 식별 체계를 확립하였다. 실험에 이용된 곶감 시료는 국내산 곶감 함안수시(Hamansusi), 예천고종시(Yecheongojongsi), 산청단성시(Sancheongdanseongsi), 그리고 논산월하시(Nonsanwalhasi) 4개 품종과 국내에서 판매되고 있는 중국산 곶감 2개 종류의 꽃받침과 종자를 사용하였으며, 꽃받침과 종자 시료의 전세포 추출물로부터 FT-IR 스펙트럼 데이터를 기반으로 다변량 통계분석(PCA, PLS-DA)을 실시하였다. 이 결과 국내산 곶감 4품종과 중국산 곶감 2종류가 두 그룹으로 확연히 나뉘어지는 것을 확인할 수 있었다. 상업용 곶감의 꽃받침을 PLS regression을 실시한 결과 국내산과 중국산 곶감을 100% 예측할 수 있었다. 또한 곶감 종자를 이용하여 품종 식별한 결과 각 4개의 그룹으로 나뉘어지는 것을 확인할 수 있었으며, PLS regression을 실시한 결과 약 86%의 정확도로 품종 식별이 가능함을 알 수 있었다. FT-IR 스펙트럼 분석의 간편성과 신속성을 고려할 때, 본 연구 결과는 상업용 곶감에 대한 원산지나 품종 식별의 신속한 수단으로 활용할 수 있을 것으로 예상된다. 더 나아가 본 기술을 이용하여 다른 농산물의 원산지 또는 품종 식별 수단으로 활용이 가능할 것으로 기대된다.

이차 미분 형광 분광광도법에 의한 울산만 해양 저질토양 중의 다환 방향족 탄화수소(PAHs)의 동시 분석 (Synchronous determination of polycyclic aromatic hydrocarbons(PAHs) in sediment of Ulsan Bay by synchronous 2nd derivative fluorescence spectrophotometry)

  • 유광식;정지영;정선이
    • 분석과학
    • /
    • 제17권1호
    • /
    • pp.45-52
    • /
    • 2004
  • 현이차 미분 형광 분광광도법을 이용하여 울산만 해양 저질토양중의 PAHs를 n-hexane용매로 추출하여 11종의 PAHs를 동시 정량분석하였다. Acenaphthene (Ace), anthracene (Anth), benzo(a)pyrene (BaP), benz(a)anthracene (BaA), benzo(b)fluoranthene (BbFt), benzo(k)fluoranthene (BkFt), chrysene (Chry), perylene (Per), phenanthrene (Phen), pyrene (Pyr) 및 fluoranthrene (Ft) 등을 정량분석 하였다. 이들 성분들의 검정선은 대략 0.15~166 ppb의 농도범위에서 직선관계를 보였으며, 0.999이상의 좋은 직선 상관계수를 보였다. 울산만의 해양 저질 토양 (sediment)에 함유된 11종의 PAHs 총량은 68.8 ng/g ~ 324.4 ng/g의 농도범위로 함유되어 있었다. 또한 PAHs의 총량은 울산만의 안쪽으로 갈수록 증가하는 경향을 보였으며, 특히 Pyr과 BaA 등과 같은 4고리화합물의 함량비가 높았다.

반도체 사진공정에서 실리콘 웨이퍼 위의 Silylated Resist의 Fourier 변환 적외선 분광분석 (Fourier Transform Infrared Spectroscopic Analysis of the Silylated Resist on Silicon Wafers in Semiconductor Lithographic Process)

  • 강성철;김수종;손민영;박춘근
    • 분석과학
    • /
    • 제5권4호
    • /
    • pp.455-464
    • /
    • 1992
  • 본 논문에서는 FT-IR 분광분석법을 이용하여 여러 가지 반응조건에서 기체상 silylation 반응에 의해 생성된 silylated layer의 depth를 비파괴적으로 정량하는 방법을 제안하였다. Silylated layer의 depth는 FT-IR 스펙트럼의 특성 봉우리들(Si-O-ph, Si-C, Si-H)의 흡광도를 바탕 스펙트럼 공제법으로 측정하여 SEM의 두께 측정치와 비교하여 정량하였다. FT-IR 분광분석법을 이용한 Silylated layer의 depth 분석은 비파괴적이고 정량적인 방법으로, 이 방법은 silylation process window를 설정하는 데 적합하다는 것을 알았다.

  • PDF

졸-겔법으로 합성한 TiO2-SiO2 분말의 분광학적 분석 (Spectroscopic Studies on the Preparation of Sol-Gel Derived TiO2-SiO2 Powder)

  • 정미원;염수진;이복임
    • 분석과학
    • /
    • 제18권1호
    • /
    • pp.1-4
    • /
    • 2005
  • 반응 속도를 조절하기 위하여 유기 첨가제인 아세트산을 사용해 치환된 티타늄 이소프로폭사이드를 합성한 뒤 가수분해 시킨 실리콘(IV)에톡사이드와 반응시켜 $TiO_2-SiO_2$ 분말을 얻었다. 반응 과정 동안의 구조 변화와 특징을 NMR과 FT-IR을 통해서 살펴보았다. 열처리 과정을 거친 분말의 FT-IR 결과로부터 상 분리를 관찰하였다.

Determination of Water Content in Skin by using a FT Near Infrared Spectrometer

  • Suh Eun-Jung;Woo Young-Ah;Kim Hyo-Jin
    • Archives of Pharmacal Research
    • /
    • 제28권4호
    • /
    • pp.458-462
    • /
    • 2005
  • The water content of skin was determined using a FT near infrared (NIR) spectrometer. NIR diffuse reflectance spectra were collected from hairless mouse, in vitro, and from human inner arm, in vivo. It was found that the variation of NIR absorbance band 1450 nm from OH vibration of water and 1940 nm from the combination involving OH stretching and OH deformation, depending on the absolute water content of separated hairless mouse skin, in vitro, using the FT NIR spectrometer. Partial least squares regression (PLSR) was applied to develop a calibration model. The PLS model showed good correlation. For practical use of the evaluation of human skin moisture, the PLS model for human skin moisture was developed in vivo on the basis of the relative water content of stratum corneum from the conventional capacitance method. The PLS model predicted human skin moisture with a standard errors of prediction (SEP) of 3.98 at 1130-1830 nm range. These studies showed the possibility of a rapid and nondestructive skin moisture measurement using FT NIR spectrometer.

TSH, FT4 검사의 Two-point Calibration Curve 적용의 유용성 평가 (Utility Evaluation of Two-point Calibration Curve applied for TSH, FT4 Tests)

  • 박혜미;유선희;이선호;김년옥
    • 핵의학기술
    • /
    • 제20권2호
    • /
    • pp.75-79
    • /
    • 2016
  • Purpose The ASAN Medical Center, Nuclear Medicine performs TSH (Thyroid stimulating hormone) and FT4 (Free Thyroxine) tests 8 times per day. Accordingly, 70 ~ 80 kit tubes are consumed every day for the measurements and the time consumed for reagent dispensing averages over 170 seconds, where the TAT (turnaround time) may be effected when the number of test samples is larger than expected. Therefore, the following test was conducted with the purpose to reduce the number of kit tubes consumed, and reduce the time for reagent dispensing. Materials and Methods The test is based on applying the same reagent for tests where the number of samples is 30 or less. The test for TSH was conducted 9 times from July $1^{st}$ 2015 to July $10^{th}$ 2015. The test for FT4 was conducted 4 times from June $18^{th}$ 2015 to June $22^{nd}$, 2015. Standard Solution No.2 (0.153 uU/mL) and No.5 (4.96 uU/mL) was selected as the two-point standards for the TSH test, and Standard Solution No.3 (0.777 ng/dL) and No.4 (2.044 ng/dL) was selected as the two-point standards for the FT4 test. 38 test samples were subject to correlation analysis. Results For TSH, the result of the normal test shows ranges of 0.20 ~ 0.37 uU/mL for Control1, 0.53 ~ 0.71 uU/mL for Control2, and 6.77 ~ 7.94uU/mL for Control3, while the result of two-point calibration curve test shows ranges of 0.18 ~ 0.27 uU/mL for Control1, 0.53 ~ 0.71 uU/mL for Control2, and 7.30 ~ 8.52 uU/mL for Control3. For FT4, the result of the normal test shows ranges of 0.85 ~ 0.94 ng/dL for Control1 and 4.23 ~ 4.57 ng/dL for Control2, while the result of two-point calibration curve test shows ranges of 0.61 ~ 0.75 ng/dL for Control1 and 3.88 ~ 5.71 ng/dL for Control2. For TSH, the CV% of the normal test for Control1, Control2 and Control3 are 10.5, 3.3 and 3.6 respectively, while the CV% of the two-point calibration curve test for Control1 and Control1 are 12.4, 8.2 and 5.1 respectively. The result shows an outstanding correlation of TSH: y = 0.9985x - 0.0459 $R^2=0.9986$. For FT4, the CV% of the normal test for Control1 and Control2 are 0.70 and 0.71 respectively, while the CV% of the two-point calibration curve test for Control1 and Control1 are 8.7 and 16.2 respectively. The result shows an outstanding correlation of FT4: y = 1.2674x - 0.1133 $R^2=0.9824$. Conclusion The two-point calibration curve can be efficiently applied for TSH in cases where the number of test samples is not large, since the number of samples to be re-tested increases when the result is abnormal from the calibration curve. The two-point calibration curve test should not be applied for FT4 where the results do not consistently comply with the quality assessment range. Depending on how the two-point calibration curve is applied, up to 5 test tubes can be conserved per test, and the reduced time for reagent dispensing is anticipated to have a positive effect on the TAT (turnaround time).

  • PDF

유한요소 해석을 이용한 초탄성체 햅틱 피드백 연구 (Hyper-elastic Model Haptic Feedback Using Finite Element Analysis)

  • 박승현;김진현
    • 센서학회지
    • /
    • 제31권4호
    • /
    • pp.260-265
    • /
    • 2022
  • In this study, we establish hyper-elastic haptic feedback in a virtual environment using finite element analysis techniques and develop a Force Torque (FT) sensor utilization method for application in tele-operation environments. In general, regarding haptic feedback data, in a tele-operation environment, the user is provided with feedback according to the measured force data when the model is inserted through an FT sensor. Conversely, in a virtual environment, the press-fitting model can be expressed through the spring-damper system rather than an FT sensor to provide feedback. However, unlike rigid and the elastic bodies, the hyper-elastic body represented by a spring-damper system in a virtual environment is a simple impedance model using stiffness and damping coefficients; it is limited in terms of providing actual feedback. Thus, in this study, haptic feedback was implemented using the data obtained from POD-RBF analysis results during hyper-elastic press-fitting experiments. The haptic feedback mechanism developed in this study was verified by comparing the FT sensor feedback data measured and calculated through hyper-elastic press-fitting experiments with spring-damper feedback data. Subsequently, the POD-RBF analysis feedback was compared and evaluated against the feedback mechanism of each environment through the test subject, and the similarities between the POD-RBF analysis feedback and FT sensor data feedback were verified.

The Panax ginseng Flowering Locus T Shows Age Specific Expression Pattern in Ginseng and Increases Root Length in Transgenic Arabidopsis

  • Mohanan, Padmanaban;Myagmarav, Davajargal;Zhang, Dabing;Kim, Yu-Jin;Yang, Deok-Chun
    • 한국자원식물학회:학술대회논문집
    • /
    • 한국자원식물학회 2018년도 춘계학술발표회
    • /
    • pp.17-17
    • /
    • 2018
  • Panax ginseng Meyer is a perennial medicinal plant, the roots of which has been used in the traditional formulations in Oriental countries. To understand its floral transition, we isolated Flowering Locus T (FT) from ginseng, the bioinformatics analysis of PgFT has revealed a considerable homology to the higher plants, with the essential amino acids for FT function are conserved. The phylogenetic analysis has shown that the PgFT is belonged to the shrub classes of plants and closest kin to Jatropha curcas FT. The expression profiling from juvenile (2-year-old) were abundant in leaves as well as in root and was concentrated in the secondary leaflet and stem bottom in adult (4-year-old) ginseng plant tissues, moreover PgFT transcript displayed photoperiod dependent oscillation. The ectopic expression of PgFT in Arabidopsis thaliana, exhibit precocious flowering and several floral pathway integrators were up-regulated, interestingly their root length was increased in the transgenic seedlings. Therefore, we could conclude that PgFT encodes a florigen that acts as a key regulator in the flowering pathway in ginseng and hypothesize that, it might involve in the underground organ development as well. We believe our finding could provoke future studies on the physiology and development in P. ginseng.

  • PDF

12wt% Co 담지 FT 촉매 제조시 유기용매가 촉매활성에 미치는 영향연구 (The Effect of Organic Solvents on the Activity for the Synthesis of 12wt% Co-based FT Catalyst)

  • 이지윤;한자령;정종태;백영순
    • 한국수소및신에너지학회논문집
    • /
    • 제26권4호
    • /
    • pp.339-346
    • /
    • 2015
  • The synthesis of Fischer-Tropsch (FT) oil is the catalytic hydrogenation of CO to give a range of products, which can be used for the production of high-quality diesel fuel, gasoline and linear chemicals. This studied catalyst was prepared Cobalt-supported alumina and silica by the incipient wet impregnation of the nitrates of cobalt, promoter and organic solvent with supports. Cobalt catalysts were calcined at $350^{\circ}C$ before being loaded into the FT reactors. After the reduction of catalyst has been carried out under $450^{\circ}C$ for 24h, FT reaction of the catalyst has been carried out at GHSV of 4,000/hr under $200^{\circ}C$ and 20atm. From these experimental results, we have obtained the results as following; In case of $SiO_2$ catalysts, the activity of 12wt% $Cobalt-SiO_2$ synthesized by organic solvent was about 2 or 3 times higher than the activity of 12wt% $Cobalt-SiO_2$ catalyst synthesized without organic solvent. In particular, the activity of the $Cobalt-SiO_2$ catalyst prepared in the presence of an organic solvent P was two to three times higher than that of the $Cobalt-SiO_2$ catalyst prepared without the organic solvent. Effect of Cr and Cu metal as a promoter was found little. 200 h long-term activity test was performed with a $Co/SiO_2$ catalyst prepared in the presence of an organic solvent of Glyoxal solution.