• Title/Summary/Keyword: FR-PVC

Search Result 11, Processing Time 0.024 seconds

Fire Resistance Characteristics of Polyolefin cable Insulating Materials for Flame Retardant (난연성 폴리 올레핀 케이블 절연재료의 내화특성)

  • Yoon, Hun-Ju;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.251-254
    • /
    • 2001
  • In this paper, we analyzed the properties change of electric wire when the thermal stress was applied to NFR-8 and FR-PVC 600[V] wire. Messurement is made of the attenuation of a light beam by smoke accumulating with in a closed chamber due to nonflaming pyrolytic decomposition and flaming combustion. Results are expressed in terms of specific optical density which is derived from a geometrical factor and the measured optical density a measurement characteristic of the concentration of smoke. Referenced documents were ASTM E662 standard test method for specific Ds genalated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of $2.5{\pm}0.04[w/cm^{2}]$ for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 25.2 to 37.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. The amount of carbon monoxide generated was found to be much higher in FR-PVC decomposition than in NFR-8 due to incomplete combustion of FR-PVC which has high content of carbon in compound.

  • PDF

Fire Resistance Characteristics of Polyolefin cable Insulating Materials for Flame Retardant (난연성 폴리 올레핀 케이블 절연재료의 내화특성)

  • 윤헌주;홍진웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.251-254
    • /
    • 2001
  • In this paper, we analysed the properties change of electric wire when the thermal stress was applied to NFR-8 and FR-PVC [600] wire. Measurement is made of the attenuation of a light beam by smoke accumulating with in a closed chamber due to nonflamining pyrolytic decomposition and flaming combustion. Results are expressed in terms of specific optical density which is derived from a geometrical factor and the measured optical density a measurement characteristic of the concentration of smoke. Referenced documents were ASTM E662 standard test method for specific Ds generated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of 2.5${\pm}$0.04[w/$\textrm{cm}^2$] for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 7.2 to 77.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. The amount of carbon monoxide generated was found to be much higher in FR-PVC decomposition than in NFR-8 due to incomp1ete combustion of FR-PVC which has high content of carbon in compound.

  • PDF

Implementation of Q3 Adaptor ATM Connection and FR Interworking Management in ATM Switch (ATM 교환기의 Q3 Adaptor ATM 연결 및 FR 연동 관리 구현)

  • 나성욱
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.10e
    • /
    • pp.85-87
    • /
    • 2002
  • 본 논문은 SNMP(Simple Network Management Protocol)기반의 ATM 교환 장비를 CMIP(common management information protocol)기반의 관리망에 연동하기 위한 Q3 Adaptor 기능 중 ATM 연결 관리와 Frame Relay 연동 관리를 소개한다. 본 논문의 ATM연결 관리는 점대점(Point-to-Point Permanent Virtual Connection) PVC(P)로 한정하고, FR 연동 관리는 ATM/FR 연결의 One-to-One PVC로 한정하며 ATM 밀 ATM/FR 연결에 대하여 CMIP Manager, Q3 Adaptor 및 교환 장비의 DB간 불일치 현상을 극복하기 위한 현행화 기능도 소개한다.

  • PDF

A Study on the Efficiency Estimation of Halogen free Fire Resistance Cable (저독성 내화전선 케이블의 성능평가에 관한 연구)

  • 윤헌주;홍진웅;유동일;윤재선;곽동일
    • Fire Science and Engineering
    • /
    • v.16 no.1
    • /
    • pp.18-23
    • /
    • 2002
  • Efficiency estimation of toxicity free resistance cable experiments were conducts to understand toxicity free fire ersistance polyolefin insulation material and smoke density characteristic and combustion gas corrosion analysis. A main cause of fire-growth and generating toxic gas when it burns, should be dealt with great care in life safety design. Similar patterned fire incidents such as, Inchon Live-Hof Pub Restaurant as, Sea-land Children Resort have proven that serious loss of lives were caused by hazardous gas generated fire resistance cable materials. In this paper, Referenced documents were ASTM E662 standard test method for specific Ds genalated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of 2.5$\pm40.04〔w/$\textrm{cm}^2$〕for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 25.2 to 37.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. Also, the fire gases was occurred carbon monoxide and decomposition than in polyolefin due to incomplete combustion of PVC which has high content of carbon in chemical compound.

Effect of Ionic Impurities in Materials for CN/CV Underground Distribution Power Cable Jackets (지중배전케이블 외피용 컴파운드의 이온투과 특성 비교)

  • Kim, Dong-Myung;Kwon, Tae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.167-168
    • /
    • 2008
  • The permeation of $Ca^{2+}$ ions through the materials such as polyvinyl chloride (PVC) and non-halogenated flame retardant cross linked polyolefin (FR-XLPO) used for CN-CV underground distribution power cable jackets was investigated. The permeation of $Ca^{2+}$ ions was found to increase with the increase of time. The FR-XLPO showed higher permeation of $Ca^{2+}$ ions, by a factor of about two, than the PVC. This was explained by the destruction of structural integrity caused by mixing a large amount of mineral flame retardant such as $Mg(OH)_2$ used to impart non-flame ability to the jacket material.

  • PDF

Ion Permeation in Compounds for the Power Cable Sheath (배전케이블 외피용 컴파운드의 이온투과 특성)

  • Kim, Dong-Myung;Park, Kwang-Seok;Suh, Kwang-S.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.864-865
    • /
    • 1998
  • Permeation of $Ca^{2+}$ ions in PVC and flame-retardant polyolefin (FR) compounds for the sheath of medium voltage underground cables was studied. At $70^{\circ}C$ ion permeation increases fast at times of up to a few tens of hour and then at a relatively slow rate. The first fast increase was attributed to the diffusion of ions in the samples while the second slow increase of ion permeation was attributed to the permeation of $Ca^{2+}$ ions through the samples. It was also found that the diffusivity of $Ca^{2+}$ ions in FR compounds is much higher than that in PVC compounds.

  • PDF

Performance Analysis of Frame Relay Traffic for the Interworking of Frame Relay and ATM (프레임 릴레이망과 ATM 망의 연동시 프레임 릴레이의 성능해석)

  • 정중수;천성권;남택용;정태수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.7B
    • /
    • pp.1261-1267
    • /
    • 1999
  • Frame relay (FR) service via an FR interface over a common asynchronous transfer mode (ATM) backbone network requires an FR-to-ATM interworking unit (IWU), the functionality of which directly impacts the engineering of the overall network in terms of capacity required, quality of service (QoS), and the interference among different types of services. This paper presents performance analysis of frame relay traffic in IWU. Additionally frame relay traffic policing using leaky bucket algorithm in this traffic model is carried out through computer simulation. Three measurements, the percentage of frames accepted as committed, the percentage of frames that accepted but marked eligible for diacard, and the percentage of frames that accepted that are discarded because of insufficient number of credits, are simulated variously in this paper.

  • PDF

ATM망에서 프레임 릴레이망을 근간으로한 기업통신망의 수용기술

  • Jeong, Jung-Su;Nam, Taek-Yong;Jeong, Tae-Su
    • The Magazine of the IEIE
    • /
    • v.25 no.6
    • /
    • pp.69-78
    • /
    • 1998
  • 프레임 릴레이망을 백본으로 한 LAN과 LAN접속으로 형성되는 기업통신망이 현재 활발히 전개되면서 인터넷을 통한 광고, 전자거래가 중요한 서비스로 진행되고 있다. 국내의 프레임 릴레이 서비스 현황을 살펴보면 KT, 데이콤, 일부기업등에서 프레임 릴레이 교환기를 수입하여 주고객인 기업에 서비스를 제공하고 있다. 이들은 사용자 요구에 의해 주로 LAN과 LAN에 접속된 라우터 등의 종단 시스템간 PVC(영구가상회선: Permanant Virtual Circuit)접속을 통하여 다양한 서비스를 제공하면서 독자적인 기업통신체계를 구축하고 있는 실정이다. 이와같이 사용자 요구로 PVC등록시 프레임 릴레이망과 LAN을 연결하는 링크의 QoS(서비스 질: Quality of Service), 트래픽 파라메터는 수동적으로 설정된다. 현재 국내에서는 프레임 릴레이 교환기 개발은 전무하고 단지 그들을 수입하여 운용하는 수준이며 향후 ATM(비동기 전달모드: Asynchronous Transfer Mode)망의 중요 서비스 연동이 될 프레임 릴레이 기술은 심도있게 연구되고 있다. 향후 고속통신을 제공하는 백본망은 기존의 프레임 릴레이망과 ATM망이 공존할 추세이며 점진적으로 프레임 릴레이망은 사라질 것이다. 이때 ATM 망이 기존의 프레임 릴레이망을 백본으로 한 기업통신망 수용시 원할한 서비스 제공을 위해서는 프레임 릴레이망을 백본으로 채택한 기존의 기업통신망을 ATM망에서 수용시 야기되는 문제점의 제시와 이의 해결은 매우 중요하다고 생각된다. FR/ATM(Frame Relay/ATM)연동시 기업통신망 입장에서는 PVC뿐만 아니라 SVC(교환가상회선: Switched Virtual Circuit)호처리가 수용되어야 한다. 이와같이 PVC와 SVC 수용으로 기업통신망은 통신망의 구성 및 관리가 복잡, 다양해지며, 또 그 기업은 관련된 다양하고 수많은 고객과 접속될 수 있어야 한다. 이때 ATM망을 백본으로 한 공중망이 관련 기업의 사설 정보를 관리하도록 한다는 것은 그 서비스의 이용자에게 보안문제를 제기함은 물론 서비스 이용자가 자신의 망에서 동작하는 여러 서비스를 고객 스스로가 관리하는 것이 바람직하다. CNN(고객망관리 : Customer Network Management)은 이러한 고객에 의한 통신망, 공중망에 대한 부분적 관리 및 서비스에 대한 관리가 이루어 질수 있도록 수행하는 기능이다. 본 논문에서는 ATM망이나 프레임 릴레이망과 ATM 망이 공존시 기업통신망관점에서 야기되는 문제점의 제시와 이의 해결 방안을 살펴보았다. 우선 FR/ATM 연동에서 PVC설정뿐만 아니라 SVC 설정 방법의 연구, 이때 고려된 QoS,트래픽 처리과정을 살펴보았다. 또한 망관리 입장에서 기업통신망 관리자와 ATM망 관리자와의 온-라인 서비스를 제공하기 위해서는 변화된 통신망 차원서의 확장된 Managed Object(MO)를 근간으로한 체계적인 CNN-NMS(CNM-Network management System)연동을 살펴본후 결론에서는 추후 계속연구 및 조사 되어야 할 항목을 기업통신망 입장에서 서술하여 보았다.

  • PDF

A Study on the Thermal Analysis of Fire-Resistance Cable using FEM (유한요소법을 이용한 내화전선의 열해석에 관한 연구)

  • 오홍석;이상호
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.5
    • /
    • pp.338-343
    • /
    • 2004
  • In general, the insulation and protective sheaths on electrical conductors are made of combustible substances like PVC, natural or synthetic rubbers, and other organic or synthetic materials. When an electrical fire starts due to overheating of conductors/joints or sparking/arcing, the first thing to ignite is usually the insulation on the cables. When the insulation bums, the produced fumes are very toxic. To solve the problem, we have surely need the fire resistance cable that doesn't bum in a high temperature and emit toxic fume for operating a disaster prevention installation. In this paper, we have simulated the thermal analysis for the fire resistance cable according to the values of current in a overload and a short, and the values of outside flame with the fire resistance cable of the L's company product(600 V, FR-8 : Four Core) using the finite element method(Flux2D).

A refinement of customer satisfactory factors in multimedia contentware evaluation process - focused on company website design - (멀티미디어 컨텐트웨어 상품에 대한 소비자 감성 평가 요소(문화성 인자)추출에 관한 연구 - 기업 웹사이트를 중심으로 -)

  • 이종호;김명석;이현이;김태균
    • Archives of design research
    • /
    • v.11 no.1
    • /
    • pp.291-302
    • /
    • 1998
  • This paper covers the development process of multimedia evaluation system, especially focused on customer satisfactory factors while customers navigating net-based Interactive multimedia system. Customers usually experience new level of interaction cased by newly developed web-based technology In ordinary multimedia system. However, if it gives customers satisfactory experience is a matter of question. To find out the relationship between customer satisfaction and interactivity factors exposed by multimedia system, a model has been developed which describes the structure of web-based multimedia system and its relation to customer satisfactory factors. Five different experiments, including 'semantic differential', 'focus group interview', and 'expert review', has been conducted and four customer satisfactory factors were identified. Those are 'customery value', 'structural perfectness', 'visual perfectness', and 'contemporaneity'. With these factors and newly delveoped evaluation system, 7 different web-site has been evaluated and analyzed at the end of this report.

  • PDF