• Title/Summary/Keyword: FOV

Search Result 339, Processing Time 0.028 seconds

Development of High Resolution Micro-CT System for In Vivo Small Animal Imaging (소형 동물의 생체 촬영을 위한 고해상도 Micro-CT 시스템의 개발)

  • Park, Jeong-Jin;Lee, Soo-Yeol;Cho, Min-Hyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.95-101
    • /
    • 2007
  • Recently, small-animal imaging technology has been rapidly developed for longitudinal screening of laboratory animals such as mice and rats. One of newly developed imaging modalities for small animals is an x-ray micro-CT (computed tomography). We have developed two types of x-ray micro-CT systems for small animal imaging. Both systems use flat-panel x-ray detectors and micro-focus x-ray sources to obtain high spatial resolution of $10{\mu}m$. In spite of the relatively large field-of-view (FOV) of flat-panel detectors, the spatial resolution in the whole-body imaging of rats should be sacrificed down to the order of $100{\mu}m$ due to the limited number of x-ray detector pixels. Though the spatial resolution of cone-beam CTs can be improved by moving an object toward an x-ray source, the FOV should be reduced and the object size is also limited. To overcome the limitation of the object size and resolution, we introduce zoom-in micro-tomography for high-resolution imaging of a local region-of-interest (ROI) inside a large object. For zoom-in imaging, we use two kinds of projection data in combination, one from a full FOV scan of the whole object and the other from a limited FOV scan of the ROI. Both of our micro-CT systems have zoom-in micro-tomography capability. One of both is a micro-CT system with a fixed gantry mounted with an x-ray source and a detector. An imaged object is laid on a rotating table between a source and a detector. The other micro-CT system has a rotating gantry with a fixed object table, which makes whole scans without rotating an object. In this paper, we report the results of in vivo small animal study using the developed micro-CTs.

A Study on Eye Point and Field of View of Older Drivers (고령운전자의 Eye Point와 전방 시계 특성에 관한 연구)

  • Lee, Seong-Il;Choi, Ji-Ho;Hwang, In-Jun;Song, Kyo-Hyun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.67-71
    • /
    • 2010
  • This study examined the field of view of older drivers based on their eye points. The subjects were 25 people whose age was over 65 years and 10 contrasting subjects on their 20s. For the experiment, we expanded the width of the A-pillar of a test vehicle. With a measuring apparatus designed for the study, we analyzed 3 axes of coordinates from glabella to a fixed point of the vehicle that would be used as CAD data of vehicle design. Result shows that average eye point of the older subjects was located significantly farther from the seat than that of the 20s approximately by 31.62mm(p=0.05). It was also found that the Binocular FOV was not significantly different between the older subjects and the 20s(p=0.85), and the effect of the width of the A-pillar on the FOV could not be found. We also measured the left and right side of the Ambinocular FOV of the older subjects. It was found that the older subjects had much wider visual angle than the 20s by 2.84 degree (F=4.78, p=0.01) on the left side, while the 20s showed significantly wider average angle than the older subjects by about 4.88 degree (F=4.78, p<0.05) on the right side. The results of this study can be used to improve the FOV based on the optimal eye points when designing a vehicle for older drivers.

Design and Verification of 3D Digital Image Correlation Systems for Measurement of Large Object Displacement Using Stereo Camera (대면적 대상물 변위계측을 위한 스테레오 카메라 3차원 DIC 시스템 기초설계 및 검증에 관한 연구)

  • Ko, Younghun;Seo, Seunghwan;Lim, Hyunsung;Jin, Tailie;Chung, Moonkyung
    • Explosives and Blasting
    • /
    • v.38 no.2
    • /
    • pp.1-12
    • /
    • 2020
  • Digital Image Correlation is a well-established method for displacements, strains and shape measurements of engineering objects. Stereo-camera 3D Digital Image Correlation (3D-DIC) systems have been developed to match the specific requirements for measurements posed by material and mechanical industries. Although DIC method provides the capabilities of scaling a field-of-view(FOV), dimensions of Geotechnical structure objects in many cases are too big to be measured with DIC based on a single camera pair. It can be the most important issue with applying 3D DIC to the measurement of Geotechnical structures. In this paper, We were present stereo vision conditions in a 3D DIC system that can be measured for large FOV(30×20m) and high precisions(z-displacement 0.5mm) of the ground objects with Stereo-camera DIC systems.

Enlargement of Field-of-View (FOV) of the CCD Camera by the Current Adjustment of the Projection Lens System in the KBSI-HVEM (KBSI-HVEM 투사렌즈 전류제어에 의한 CCD Camera의 Field of View(FOV) 확장)

  • Kim, Young-Min;Shim, Hyo-Sik;Kim, Youn-Joong
    • Applied Microscopy
    • /
    • v.35 no.4
    • /
    • pp.98-104
    • /
    • 2005
  • A FOV (field-of-view) of the HV-MSC (high voltage multi-scan CCD, $1024{\times}1024$ pixels) camera mounted in the post-column HV-GIF (high voltage gatan image filter) has been drastically enlarged by the projection lens current adjustment. An imaging area of the HV-MSC camera obtained at the lowest magnification (2,000x) is $112{\mu}m^2$ which corresponds to the recording area of the film at the magnification of 8,800x, while the achievable recording area is only $0.43{\mu}m^2$ at the same magnification without this technique. Ignoring the image distortion of less than 5%, we have designed an on-site reference graph to estimate projection lens currents for microscope magnifications above 8,800x, where the recording area on the HVMSC is same as that on the film.

A Effectiveness of Multi-Transmit Parallel Technique on Magnetic Resonance Imaging of FOV Less Than 26cm (자기공명영상검사 시 26cm 이하 영상영역의 Multi-Transmit 기법의 유용성)

  • Son, Soon-Yong;Choi, Kwan-Woo;Park, Kyeong-Jin;Lee, Jong-Seok;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.429-435
    • /
    • 2015
  • The purpose of this study was to prospectively estimate the effectiveness of multi-transmit parallel technique in reduced FOV(Field of View) less than 26 cm. Homogeneity, SNR(signal to noise ratio) and acquisition time were measured and compared by setting FOV less than 26cm on the T1 and T2 weighted images using ACR phantom. The multi-transmit parallel technique resulted in significantly faster image acquisition by 46.8 % in T1 weighted images and 18.9% in T2 weighted images. The homogeneity and SNR values had no significant difference between pre and post application of the multi-transmit parallel technique. In conclusion, this study demonstrates the feasibility of multi-transmit parallel technique in FOV less than 26cm with a rapid acquisition and maintained image quality.

Infrared Dual-field-of-view Optical System Design with Electro-Optic/Laser Common-aperture Optics

  • Jeong, Dohwan;Lee, Jun Ho;Jeong, Ho;Ok, Chang Min;Park, Hyun-Woo
    • Current Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.241-249
    • /
    • 2018
  • We report a midinfrared dual-field-of-view (FOV) optical system design for an airborne electro-optical targeting system. To achieve miniaturization and weight reduction of the system, it has a common aperture and fore-optics for three different spectral wavelength bands: an electro-optic (EO) band ($0.6{\sim}0.9{\mu}m$), a midinfrared (IR) band ($3.6{\sim}4.9{\mu}m$), and a designation laser wavelength ($1.064{\mu}m$). It is free to steer the line of sight by rotating the pitch and roll axes. Our design co-aligns the roll axis, and the line of sight therefore has a fixed entrance pupil position for all optical paths, unlike previously reported dual-FOV designs, which dispenses with image coregistration that is otherwise required. The fore-optics is essentially an achromatized, collimated beam reducer for all bands. Following the fore-optics, the bands are split into the dual-FOV IR path and the EO/laser path by a beam splitter. The subsequent dual-FOV IR path design consists of a zoom lens group and a relay lens group. The IR path with the fore-optics provides two stepwise FOVs ($1.50^{\circ}{\times}1.20^{\circ}$ to $5.40^{\circ}{\times}4.32^{\circ}$), due to the insertion of two Si lenses into the zoom lens group. The IR optical system is designed in such a way that the location and f-number (f/5.3) of the cold stop internally provided by the IR detector are maintained when changing the zoom. The design also satisfies several important performance requirements, including an on-axis modulation transfer function (MTF) that exceeds 10% at the Nyquist frequency of the IR detector pitch, with distortion of less than 2%.

Image Sensor Module for Detecting Space Illuminance in Indoor Environment (실내 환경의 공간조도 검출을 위한 이미지센서모듈)

  • Moon, Seong-Jae;Lim, Yeong-Seog
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.7
    • /
    • pp.771-778
    • /
    • 2019
  • The traditional illuminance intensity detection method using a single sensor has a problem that uniformity of illuminance detection is deteriorated depending on the measurement position due to the narrow FOV characteristic. In order to overcome this problem, a method of detecting an average illuminance value through a plurality of illuminance sensors is used, but the complexity and detection error are increased. In this paper, we propose a illuminance intensity detection method based on a single image sensor with wide FOV. The proposed method can solve the problems such as system complexity and error increase of existing illuminance sensor. The test results show that the difference of average value is 12% using a illuminance sensor, 10.7% using five illuminance sensors, and 6.2% using an image sensor compared with the reference value using the color difference illuminometer. It is confirmed that the proposed method can easily and accurately detect the space illuminance with improved uniformity.

Effect of object position in the field of view and application of a metal artifact reduction algorithm on the detection of vertical root fractures on cone-beam computed tomography scans: An in vitro study

  • Nikbin, Ava;Kajan, Zahra Dalili;Taramsari, Mehran;Khosravifard, Negar
    • Imaging Science in Dentistry
    • /
    • v.48 no.4
    • /
    • pp.245-254
    • /
    • 2018
  • Purpose: To assess the effects of object position in the field of view (FOV) and application of a metal artifact reduction (MAR) algorithm on the diagnostic accuracy of cone-beam computed tomography (CBCT) for the detection of vertical root fractures(VRFs). Materials and Methods: Sixty human single-canal premolars received root canal treatment. VRFs were induced in 30 endodontically treated teeth. The teeth were then divided into 4 groups, with 2 groups receiving metal posts and the remaining 2 only having an empty post space. The roots from different groups were mounted in a phantom made of cow rib bone, and CBCT scans were obtained for the 4 different groups. Three observers evaluated the images independently. Results: The highest frequency of correct diagnoses of VRFs was obtained with the object positioned centrally in the FOV, using the MAR algorithm. Peripheral positioning of the object without the MAR algorithm yielded the highest sensitivity for the first observer (66.7%). For the second and third observers, a central position improved sensitivity, with or without the MAR algorithm. In the presence of metal posts, central positioning of the object in the FOV significantly increased the diagnostic sensitivity and accuracy compared to peripheral positioning. Conclusion: Diagnostic accuracy was higher with central positioning than with peripheral positioning, irrespective of whether the MAR algorithm was applied. However, the effect of the MAR algorithm was more significant with central positioning than with peripheral positioning of the object in the FOV. The clinical experience and expertise of the observers may serve as a confounder in this respect.

The Evaluation of the Difference of the SUV Caused by DFOV Change in PET/CT (PET/CT 검사에서 확대된 표시시야가 표준섭취계수에 미치는 영향 평가)

  • Kwak, In-Suk;Lee, Hyuk;Choi, Sung-Wook;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.13-20
    • /
    • 2011
  • Purpose: The limited FOV(Field of View) of CT (Computed Tomography) can cause truncation artifact at external DFOV (Display Field of View) in PET/CT image. In our study, we measured the difference of SUV and compared the influence affecting to the image reconstructed with the extended DFOV. Materials and Methods: NEMA 1994 PET Phantom was filled with $^{18}F$(FDG) of 5.3 kBq/mL and placed at the center of FOV. Phantom images were acquired through emission scan. Shift the phantom's location to the external edge of DFOV and images were acquired with same method. All of acquired data through each experiment were reconstructed with same method, DFOV was applied 50 cm and 70 cm respectively. Then ROI was set up on the emission image, performed the comparative analysis SUV. In the clinical test, patient group shown truncation artifact was selected. ROI was set up at the liver of patient's image and performed the comparative analysis SUV according to the change of DFOV. Results: The pixel size was increase from 3.91 mm to 5.47 mm according to the DFOV increment in the centered location phantom study. When extended DFOV was applied, $_{max}SUV$ of ROI was decreased from 1.49 to 1.35. In case of shifted the center of phantom location study, $_{max}SUV$ was decreased from 1.30 to 1.20. The $_{max}SUV$ was 1.51 at the truncated region in the extended DFOV. The difference of the $_{max}SUV$ was 25.9% higher at the outside of the truncated region than inside. When the extended DFOV was applied, $_{max}SUV$ was decreased from 3.38 to 3.13. Conclusion: When the extended DFOV was applied, $_{max}SUV$ decreasing phenomenon can cause pixel to pixel noise by increasing of pixel size. In this reason, $_{max}SUV$ was underestimated. Therefore, We should consider the underestimation of quantitative result in the whole image plane in case of patient study applied extended DFOV protocol. Consequently, the result of the quantitative analysis may show more higher than inside at the truncated region.

  • PDF

50% Flashover Voltage and V-t Characteristics for $SF_6-N_2$ Mixtures under Positive & Negative Ligtning Impulse Voltage ($SF_6-N_2$ 혼합가스의 정.부극성 뇌충격전압에 대한 50% FOV와 V-t 특성)

  • Song, W.P.;Kim, J.D.;Koh, H.S.;Kim, D.O.;Kwon, Y.H.;Cho, K.B.;Lee, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.300-303
    • /
    • 1991
  • Sulphur-hexafluoride has extensively been used as an insulating gas of electric power equipment in substation for its high dielectric strength, non-toixity and non-flammable properties. But it is very expensive and is liquidizable under the condition of low temperature and high pressure. And it is very sensible to the locally high electric field strength. To resolve these problems, we studied 50% FOV and V-t characteristics of $SF_6-N_2$ mixtures under positive and negative lightning impulses using a 25mm rod-plane gap. 50% FOV of $SF_6-N_2$ 50% mixture was about 85% of pure $SF_6$ and it was known that $SF_6-N_2$ mixtures can be used as an economic substitution insulating gas for $SF_6$.

  • PDF