• Title/Summary/Keyword: FOV

Search Result 340, Processing Time 0.026 seconds

Cortical Network Activated by Korean Traditional Opera (Pansori): A Functional MR Study

  • Kim, Yun-Hee;Kim, Hyun-Gi;Kim, Seong-Yong;Kim, Hyoung-Ihl;Todd. B. Parrish;Hong, In-Ki;Sohn, Jin-Hun
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.04a
    • /
    • pp.113-119
    • /
    • 2000
  • The Pansori is a Korean traditional vocal music that has a unique story and melody which converts deep emotion into art. It has both verbal and emotional components. which can be coordinated by large-scale neural network. The purpose of this study is to illustrate the cortical network activated by a Korean traditional opera, Pansori, with different emotional valence using functional MRI (fMRI).Nine right-handed volunteers participated. Their mean age was 25.3 and the mean modified Edinburgh score was +90.1. Activation tasks were designed for the subjects to passively listen to the two parts of Pansories with sad or hilarious emotional valence. White noise was introduced during the control periods. Imaging was conducted on a 1.5T Siemens Vision Vision scanner. Single-shot echoplanar fMRI scans (TR/TE 3840/40 ms, flip angle 90, FOV 220, 64 x 64 matrix, 6mm thickness) were acquired in 20 contiguous slices. Imaging data were motion-corrected, coregistered, normalized, and smoothed using SPM-96 software.Bilateral posterior temporal regions were activated in both of Pansori tasks, but different asymmetry between the tasks was found. The Pansori with sad emotion showed more activation in the light superior temporal regions as well as the right inferior frontal and the orbitofrontal areas than in the right superior temporal regions as well as the right inferior frontal and the orbitofrontal areas than in the left side. In the Pansori with hilarious emotion, there was a remarkable activation in the left hemisphere especially at the posterior temporal and the temporooccipital regions as well as in the left inferior and the prefrontal areas. After subtraction between two tasks, the sad Pansori showed more activation in the right temporoparietal and the orbitofrontal areas, in contrast, the one with hilarious emotion showed more activation in the left temporal and the prefrontal areas. These results suggested that different hemispheric asymmetry and cortical areas are subserved for the processing of different emotional valences carried by the Pansories.

  • PDF

Neural Activation in the Somatosensory Cortex by Electrotactile Stimulation of the Fingers: A Human fMRI Study

  • Seok, Ji-Woo;Jang, Un-Jung;Sohn, Jin-Hun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.5
    • /
    • pp.395-405
    • /
    • 2014
  • Objective: The aim of this study is to investigate 1) somatotopic arrangement of the second and third fingers in SI area 2) difference of neural activation in the SI area produced by stimulation with different frequencies 3) correlation between the intensity of tactile perception by different stimulus intensity and the level of brain activation measurable by means of fMRI. Background: Somatosensory cortex can obtain the information of environmental stimuli about "where" (e.g., on the left palm), "what" (e.g., a book or a dog), and "how" (e.g., scrub gently or scrub roughly) to organism. However, compared to visual sense, the neural mechanism underlying the processing of specific electrotactile stimulus is still unknown. Method: 10 right-handed subjects participated in this study. Non-painful electrotactile stimuli were delivered to two different finger tips of right hand. Functional brain images were collected from 3.0T MRI using the single-shot EPI method. The scanning parameters were as follows: TR and TE were 3000, 35ms, respectively, flip angle 60, FOV $24{\times}24cm$, matrix size $64{\times}64$, slice thickness 4mm (no gap). SPM5 was used to analyze the fMRI data. Results: Significant activations produced by the stimulation were found in the SI, SII, the subcentral gyrus, the precentral gyrus, and the insula. In all participants, statistically significant activation was observed in the contralateral SI area and the bilateral SII areas by the stimulation on the fingers but ipsilaterally dominant. The SI area representing the second finger generally located in the more lateral and inferior side than that of the third finger across all the subjects. But no difference in brain area was found for the stimulation of the fingers by different frequencies. And two typical patterns were observed on the relationship between the perceived psychological intensity and the amount of voxels in the primary sensory cortex during the stimulation. Conclusion: It was possible to discriminate the representation sites in the SI by electrotactile stimulation of digit2 and digit3. But we could not find the differences of the brain areas according to different stimulation frequencies from 3 to 300Hz. Application: The results of the study can provide a deeper understanding of somatosensory cortex and offer the information for tactile display for blinds.

Evaluation of Cerebral Cortices Associated with Sexual Arousal in Healthy Male Using BOLD-based Functional MRI

  • Kim, Hyung-Joong;Seo, Jeong-Jin;Kang, Heoung-Keun;Jeong, Gwang-Woo;Park, Jin-Gyoon;Jeong, Yong-Yeon;Chung, Tae-Woong;Woong Yoon;Park, Kwang-Sung
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.137-137
    • /
    • 2001
  • Purpose: The purpose of this study was to identify cerebral cortices related with sexual arousal fro visual sexual stimulation in healthy males using BOLD-based functional MR imaging Method: Sixteen male volunteers with sexually potent(mean age:24) were examined for thi study. Functional MRI was performed on a 1.5T MR scanner(GE Signa Horizon) with birdcage-type head coil. In this study, blood oxygenation level dependent(BOLD) technique was utilized to create fMR image reflecting local brain activities. The BOLD-based fMRI d were obtained from 7 oblique planes using gradient-echo EPI with $90^{\circ}$flip angle, 50ms TE 6000ms TR, $26cm{\times}26$ cm FOV, $128{\times}128$ matrix, and 10mm slice thickness. The sexual stimulation paradigm consisted of two alternating periods of rest and activati and it began with a 1 minute rest, followed by a 2 minute stimulation by a documentary a erotic video film. Brain activation maps were generated by cross-correlation of imag acquired during rest and activation periods. The index of activation was used to compare t number of pixels activated by each task in each volunteer, where the significance of th differences was evaluated by using Students t-test.

  • PDF

Artifacts Improvement by using the Echo Planar Imaging and Pre-Saturation Pulse Band techniques of Reduced Field-Of-View in Breast Magnetic Resonance Imaging Examination (유방 자기공명영상검사에서 감소된 영상영역의 에코평면영상기법과 사전포화기법 사용에 의한 인공물 개선)

  • Lee, Jaeheun;Kim, Hyunjin;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.307-314
    • /
    • 2015
  • This study was conducted in reducing the involuntary motion artifacts because of lungs and heart movements as well as the aliasing artifacts generated during the use of the reduced-FOV EPI technique while performing breast MRI. Performed on a total of 38 obesity female subjects who visited the clinic for pre-examination before surgery within the period from August 1 to November 30, 2014. The 3.0T MRI scanner equipped with a breast scanning coil. Qualitative and quantitative analyses were each used for the evaluation of the acquired images while an Paired T-test and Wilcoxon rank test were performed to check the statistical significance. The variation ratio rose by 15.69% with the additional application of a pre-saturation pulse in the lesion, by 13.72% near the lesion, and 20.63% in the fat and the contrast-to-noise ratio rose by 10.58% in and near the lesion and by 12.03% in the lesion and fat, respectively. there were increases of 22.05% and 21.42% at 0 and 1000 respectively in qulitative evaluation and growth of 16.10% in apparent diffusion coefficient. it showed a statistically significant result(p<0.05) in signal to noise ratio, contrast to noise ratio, diffusion slope coefficient and apparent diffusion coefficient. The involuntary movements artifacts that occur in the phase encoding direction and the aliasing artifacts are considered to be reduced to obtain the best image in the additional use of the pre-saturation pulse as DWI is acquired.

Multi-screen Content Creation using Rig and Monitoring System (다면 콘텐츠 현장 촬영 시스템)

  • Lee, Sangwoo;Kim, Younghui;Cha, Seunghoon;Kwon, Jaehwan;Koh, Haejeong;Park, Kisu;Song, Isaac;Yoon, Hyungjin;Jang, Kyungyoon
    • Journal of the Korea Computer Graphics Society
    • /
    • v.23 no.5
    • /
    • pp.9-17
    • /
    • 2017
  • Filming using multiple cameras is required for the production of the multi-screen content. It can fill the viewer's field of view (FOV) entirely to provide an increased sense of immersion. In such a filming scenario, it is very important to monitor how images captured by multiple cameras are displayed as a single content or how the content will be displayed in an actual theatre. Most recent studies on creating the content of special format have been focused on their own purposes, such as stereoscopic and panoramic images. There is no research on content creation optimized for theatres that use three screens that are spreading recently. In this paper, we propose a novel content production system with a rig that can control three cameras and monitoring software specialized for multi-screen content. The proposed rig can precisely control the angles between the cameras and capture wide angle of view with three cameras. It works with monitoring software via remote communication. The monitoring software automatically aligned the content in real time, and the alignment of the content is updated according to the angle of camera rig. Futher, the producion efficiency is greatly improved by making the alignment information available for post-production.

Adaptive Strip Compression for Panorama Video Streaming (파노라마 동영상 스트리밍을 위한 적응적 스트립 압축 기법)

  • Kim Bo Youn;Jang Kyung Ho;Koo Sang Ok;Jung Soon Ki
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.33 no.1_2
    • /
    • pp.137-146
    • /
    • 2006
  • Traditional live video streaming systems support the limited field of view (FOV) of image to the remote users. A server system based on the pan/tilt camera provides a user with wide view by changing the view direction of the camera mechanically. But, when many clients try to access to the server, this system can not offer their own view to every user simultaneously, and moreover it has the delay by camera motion. In order to offer wide views to several users, we propose new streaming system using the panorama image that has wide view. Our system is a kind of implementation of software pan/tilt camera. The server acquires panorama video and sends a part of the video to clients. Then, each client can control their own view. We need the effective way to reduce the average transmission data size and server burden to the compression because generally the full size of panorama video is too big to be served by the real-time streaming. To solve this problem, we propose an strip-based video compression and adaptive transmission of the compressed multiple strip videos. Experimental results show that our system can be adapted quickly to the change of view and the number of clients. Furthermore, proposed method effectively reduce the transmission data.

Evaluation of MR-SENSE Reconstruction by Filtering Effect and Spatial Resolution of the Sensitivity Map for the Simulation-Based Linear Coil Array (선형적 위상배열 코일구조의 시뮬레이션을 통한 민감도지도의 공간 해상도 및 필터링 변화에 따른 MR-SENSE 영상재구성 평가)

  • Lee, D.H.;Hong, C.P.;Han, B.S.;Kim, H.J.;Suh, J.J.;Kim, S.H.;Lee, C.H.;Lee, M.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.245-250
    • /
    • 2011
  • Parallel imaging technique can provide several advantages for a multitude of MRI applications. Especially, in SENSE technique, sensitivity maps were always required in order to determine the reconstruction matrix, therefore, a number of difference approaches using sensitivity information from coils have been demonstrated to improve of image quality. Moreover, many filtering methods were proposed such as adaptive matched filter and nonlinear diffusion technique to optimize the suppression of background noise and to improve of image quality. In this study, we performed SENSE reconstruction using computer simulations to confirm the most suitable method for the feasibility of filtering effect and according to changing order of polynomial fit that were applied on variation of spatial resolution of sensitivity map. The image was obtained at 0.32T(Magfinder II, Genpia, Korea) MRI system using spin-echo pulse sequence(TR/TE = 500/20 ms, FOV = 300 mm, matrix = $128{\times}128$, thickness = 8 mm). For the simulation, obtained image was multiplied with four linear-array coil sensitivities which were formed of 2D-gaussian distribution and the image was complex white gaussian noise was added. Image processing was separated to apply two methods which were polynomial fitting and filtering according to spatial resolution of sensitivity map and each coil image was subsampled corresponding to reduction factor(r-factor) of 2 and 4. The results were compared to mean value of geomety factor(g-factor) and artifact power(AP) according to r-factor 2 and 4. Our results were represented while changing of spatial resolution of sensitivity map and r-factor, polynomial fit methods were represented the better results compared with general filtering methods. Although our result had limitation of computer simulation study instead of applying to experiment and coil geometric array such as linear, our method may be useful for determination of optimal sensitivity map in a linear coil array.

수삼 내부의 자기공명영상 특성

  • 손재룡;이강진;최동수;김기영;강석원;최규홍
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2003.10a
    • /
    • pp.151-152
    • /
    • 2003
  • 최근 NMR, MRI, x-선 등 전자파의 기술이 발전되면서 이들을 이용하여 내부품질을 검출하는 보다진보된 연구가 수행되고 있다. 관련 연구로는 자기공명영상을 이용하여 내공수삼 및 정상수삼의 내부를 촬영하여 T$_1$, T$_2$의 값을 측정하여 내부조직의 이상유무를 추정하였고, 또한 MRI에 의해 수삼의 내부품질 뿐만 아니라 연근 판정 가능성을 검토하는 등 많은 연구가 수행되고있다. 이 연구에서는 MRI 시스템을 이용하여 수삼의 내부단면 영상을 획득하여 내부결함 유무를 검출하고, 또한 동일한 수삼을 대상으로 홍삼 제조 후 내부품질의 변화 특성을 조사하고자 수행하였다. 공시재료는 충북 음성에 있는 인삼연초연구원에서 4~6년 근 된 수삼을 이용하였고, 시험 장비로는 국내 MRI 생산 전문 업체인 ISOL Tech. Co.에서 개발한 의료용 장비인 CHORUS 1.5T(자속밀도 1.5 Tesla)를 이용하였다. 슬라이스 두께/간격은 5mn/5mn, 촬영 단면수는 15장/시료, 영상영역(FOV)은 180mmx90mm, image size는 256$\times$128 pixels 그리고 TR/TE는 각각의 이완상수별로 500/13(Tl), 4,000/63(T2) 및 2,200/21(Pd)에 대한 단면영상을 얻었다. 5개의 수삼을 동시에 뇌두에서 뿌리 쪽으로 MR 단면영상을 획득하였다. 이완상수 T$_1$, T$_2$, Pd에 대해서 MR 영상을 획득하였으며, 총 15장의 단면 영상 중 내부 상태를 가장 잘 식별 할 수 있는 영상을 조사한 결과 T$_1$과 Pd에서 촬영한 영상에서는 내부상태가 잘 나타났으나, T$_2$에서 얻은 영상은 영상의 손실이 많이 발생되었다. 한편, T$_1$에 대해서 뇌두에서 뿌리쪽으로 가면서 각 위치에 따라 수삼 내부의 부패된 영상이 나타나 이에 대한 판정은 가능한 것으로 나타났다. 2000년도와 2001년도에 각각 수확.저장된 수삼을 부위별로 단면영상을 MRI로 측정하고, 그 시료를 인삼연초연구원(음성시험장)에서 홍삼으로 제조한 후 수삼 상태에서의 내부품질과 홍삼으로 제조된 후의 내부품질 변화를 조사하였다. 총 20본의 수삼을 MRI 시스템으로 영상을 획득하였고, 모든 시료에 대해서 내부조직의 상태를 관찰하였다. 수삼의 수분함량은 뇌두로부터 1cm부위를 절단하여 조사하였고, 수삼조직은 절단시 단면의 달관 조사에 의한 성적이며 홍삼품질은 제조삼의 조직상태를 절단하여 육안판별로 검사하였다. 총 20본의 수삼 중 정상은 16본 이었고, 이들은 홍삼으로 제조된 후 내공 내백 등이 혼재되어 나타났으며 정상수삼이 정상홍삼으로 나타난 경우는 5본이었고, 내백은 5본, 내공은 6본으로 조사되었다. 또한 수삼에서 4본은 썩은 부위가 포함되어있는 수삼이었는데 홍삼으로 제조되었을 때 3본은 내백으로 되었고 1 본은 수삼에서 썩은 부위가 1/4정도로 미미해서 홍삼 제조시 정상으로 나타났다. 일반적으로 홍삼 제조시 내공의 발생은 제조공정에서 나타나는 경우가 많으며, 내백의 경우는 홍삼으로 가공되면서 발생하는 경우가 있고, 인삼이 성장될 때 부분적인 영양상태의 불충분이나 기후 등에 따른 영향을 받을 수 있기 때문에 앞으로 이에 대한 많은 연구가 이루어져야할 것으로 판단된다.

  • PDF

The New Finding on BOLD Response of Motor Acupoint KI6(照海) by fMRI (fMRI를 이용하여 수지굴신운동(手指屈伸運動)과 조해(照海)(KI6) 자침(刺鍼)에 의(依)한 대뇌운동피질(大腦運動皮質)의 활성변화(活性變化)에 관(關)한 비교(比較) 연구(硏究))

  • Kwon, Cheol-hyeon;Lee, Jun-beom;Hwang, Min-seob;Yoon, Jong-hwa
    • Journal of Acupuncture Research
    • /
    • v.21 no.6
    • /
    • pp.177-186
    • /
    • 2004
  • Introduction : Recent studies Suggested that there is a strong correlation between acupuncture stimulation and its related cortical activation. Anther study showed that either positive or negative BOLD effects could be observed depending on anatomical structure in acupuncture stimulation. In ttis study, we investigated a new acupoint $KI_6$ (照海), which was known as motor-related acupoint and obtained an evidence that the stimulation of $KI_6$ resulted in either negative or positive BOLD response to stimulation. Methods & Results : 1. Subjects and paradigms : Two separate stimulation paradigms were performed on five healthy (aged 22-23 yrs) in this study. First, the paradigm of acupuncture stimulation was that the acupuncture needle was inserted in acupoints $KI_6$, which is located in lateral side of the foot and then continuously twisted(補瀉를 除外한 捻轉法) for 70 seconds for 10 cycles of activation. During rest period (70 seconds), the needle was completed removed from acupoint. Total 60 cycles were performed and 10 images were obtained per cycle. Second, nonacupoint was randomly selected and the same paradigm was performed as acupoint stimulation. The stimulation protocol comprised 10 cycles of alternating. activation and rest (10 images per cycle). Total 60 cycles were performed and each cycle take about 1.5 sec for motor task. Subjects take an at least 15 minutes break before starting anther paradigm. 2. fMRI mapping : Multi-slice functional images were obtained on a 1.5T Magnetom Vision MRI scanner (Simens Medical, Erlangen, Germany) equipped with high performance whole-body gradients. The BOLD T2 * - weighted images were acquired with acho planar imaging sequence (TR = 1.2 sec, TE = 60 msec, and flip angle = $90_{\circ}$). The other sequence parameter are : FOV = 210 mm, matrix=$64{\times}128$ or $64{\times}64$, slice number=10 and slice thickness = 5 or 8 mm. the anatomic images were obtained with Spin-echo T1-weighted images. The resulting images were then anaiyzed with STIMULATE (CMRR, U. of Minnesota) to generate functional maps using a student T-test (p < 0.005) and cluster analysis. Both positive and negative response were evaluated. Conclusions : We have observed the activation of the motor cortex by stimulating motor-related acupoint ($KI_6$). Among five subjects, negative BOLD response was shown in four and positive response in one. All subjects showed positive response to conventional finger flexion-extension task. To understand the detailed mechanisms of correlation between acupuncture stimulation and BOLD fMRI changes and two typs of response, further study strongly required.

  • PDF

Software development for the visualization of brain fiber tract by using 24-bit color coding in diffusion tensor image

  • Oh, Jung-Su;Song, In-Chan;Ik hwan Cho;Kim, Jong-Hyo;Chang, Kee-Hyun;Park, Kwang-Suk
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.133-133
    • /
    • 2002
  • Purpose: The purpose of paper is to implement software to visualize brain fiber tract using a 24-bit color coding scheme and to test its feasibility. Materials and Methods: MR imaging was performed on GE 1.5 T Signa scanner. For diffusion tensor image, we used a single shot spin-echo EPI sequence with 7 non-colinear pulsed-field gradient directions: (x, y, z):(1,1,0),(-1,1,0),(1,0,1),(-1,0,1),(0,1,1),(0,1,-1) and without diffusion gradient. B-factor was 500 sec/$\textrm{mm}^2$. Acquisition parameters are as follows: TUTE=10000ms/99ms, FOV=240mm, matrix=128${\times}$128, slice thickness/gap=6mm/0mm, total slice number=30. Subjects consisted of 10 normal young volunteers (age:21∼26 yrs, 5 men, 5 women). All DTI images were smoothed with Gaussian kernel with the FWHM of 2 pixels. Color coding schemes for visualization of directional information was as follows. HSV(Hue, Saturation, Value) color system is appropriate for assigning RGB(Red, Green, and Blue) value for every different directions because of its volumetric directional expression. Each of HSV are assigned due to (r,$\theta$,${\Phi}$) in spherical coordinate. HSV calculated by this way can be transformed into RGB color system by general HSV to RGB conversion formula. Symmetry schemes: It is natural to code the antipodal direction to be same color(antipodal symmetry). So even with no symmetry scheme, the antipodal symmetry must be included. With no symmetry scheme, we can assign every different colors for every different orientation.(H =${\Phi}$, S=2$\theta$/$\pi$, V=λw, where λw is anisotropy). But that may assign very discontinuous color even between adjacent yokels. On the other hand, Full symmetry or absolute value scheme includes symmetry for 180$^{\circ}$ rotation about xy-plane of color coordinate (rotational symmetry) and for both hemisphere (mirror symmetry). In absolute value scheme, each of RGB value can be expressed as follows. R=λw|Vx|, G=λw|Vy|, B=λw|Vz|, where (Vx, Vy, Vz) is eigenvector corresponding to the largest eigenvalue of diffusion tensor. With applying full symmetry or absolute value scheme, we can get more continuous color coding at the expense of coding same color for symmetric direction. For better visualization of fiber tract directions, Gamma and brightness correction had done. All of these implementations were done on the IDL 5.4 platform.

  • PDF