• Title/Summary/Keyword: FOV

Search Result 340, Processing Time 0.03 seconds

Hot plasmas in coronal mass ejection observed by Hinode/XRT

  • Lee, Jin-Yi;Raymond, John C.;Reeves, Katharine K.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.97-97
    • /
    • 2012
  • Hinode/XRT has observed coronal mass ejections (CMEs) since it launched on Sep. 2006. Observing programs of Hinode/XRT, called 'CME watch', perform several binned observations to obtain large FOV observations with long exposure time that allows the detection of faint CME plasmas in high temperatures. Using those observations, we determine the upper limit to the mass of hot CME plasma using emission measure by assuming the observed plasma structure. In some events, an associated prominence eruption and CME plasma were observed in EUV observations as absorption or emission features. The absorption feature provides the lower limit to the cold mass while the emission feature provides the upper limit to the mass of observed CME plasma in X-ray and EUV passbands. In addition, some events were observed by coronagraph observations (SOHO/LASCO, STEREO/COR1) that allow the determination of total CME mass. However, some events were not observed by the coronagraphs possibly because of low density of the CME plasma. We present the mass constraints of CME plasma and associated prominence as determined by emission and absorption in EUV and X-ray passbands, then compare this mass to the total CME mass as derived from coronagraphs.

  • PDF

MIRIS 우주관측 카메라 Calibration

  • Park, Yeong-Sik;Lee, Dae-Hui;Jeong, Ung-Seop;Mun, Bong-Gon;Lee, Deok-Haeng;Pyo, Jeong-Hyeon;Park, Gwi-Jong;Park, Seong-Jun;Nam, Uk-Won;Lee, Chang-Hui;Park, Jang-Hyeon;Han, Won-Yong;Lee, Seung-U;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.71-71
    • /
    • 2012
  • MIRIS(Multipurpose InfraRed Imaging System)는 과학기술위성 3호의 주 탑재체이며 우주관측카메라, 지구관측카메라, 전장박스로 구성되어 있다. MIRIS 우주관측 카메라는 0.9-2.0 ${\mu}m$ 영역에서 3.67 deg. ${\times}$ 3.67 deg. FOV로 우리 은하평면 survey 관측과 우주배경복사(CIB) 관측을 수행할 것이다. MIRIS는 2월 말에 비행모델 개발을 완료하였고, 향후 위성체와의 조립을 진행하고, 러시아 Dnepr 발사장으로 옮겨 2012년 하반기에 발사 예정이다. MIRIS 우주관측카메라에는 Teledyne PICNIC(256${\times}$256 pixel) array를 사용하였고, Dark current, Linearity, Read-out Noise, Gain, Flat 영상 측정 등의 calibration을 수행하였다. 본 발표에서는 Calibration 결과에 대해 논의 하고자 한다.

  • PDF

The Software Development for Diffusion Tensor Imaging

  • Song, In-Chan;Chang, Kee-Hyun;Han, Moon-Hee
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.112-112
    • /
    • 2001
  • Purpose: We developed the software for diffusion tensor imaging and evaluated its feasibility in norm brains. Method: Five normal volunteers, aged from 25 to 29 years, were examined on a 1.5 T MR system. the diffusion tensor pulse sequence used a SE-EPI with 6 diffusion gradie directions of (1, 1, 0), (-1, 1,0), (1, 0, 1), (-1, 0, 1), (0, 1, 1), (0, 1, -1) and also with no diffusion gradient. A b-factor of 500 sec/mm2 was used. Measurement parameter were as follows; TR/TE=10000 ms/99 ms, FOV=240 mm, matrix=128$\times$128, slice thickness/gap=6 mm/0 mm, bandwidth=91 kHz and the number of total slices=20. Four repeated axial diffusion images were averaged for diffusion tensor imaging. A total scan 11 of 4 min 30 sec was used. Six full diffusion tensor components of Dxx, Dyy, Dzz, Dxy, Dxz and Dyz were obtained using two-point linear regression model from 7 diffusion-weight images at each pixel and fractional anisotropy and lattice index images was estimated fr their eigenvectors and eigenvalues. Our program was written on a platform of IDL. W evaluated the qualities of fractional anisotropy and lattice index images of normal brains a knew whether our software for diffusion tensor imaging may be feasible.

  • PDF

Z-Score를 이용한 관류영상과 조영전후 감산에 의한 역동영상의 뇌관류 양상의 비교 관찰

  • 최순섭;오종영;남경진;이영일
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.171-171
    • /
    • 2001
  • 목적: 뇌 자기공명영상에서 Z-score를 이용한 관류 영상과 조영전후의 감산에 의한 역동 영상의 관류 양상을 비교 관찰 하고자 한다. 대상 및 방법: 뇌 자기공명영상에서 이상 소견이 없는 젊은 환자 1명, Moya moya 환자 1, 중대뇌동맥 폐색 환자 1명, 외상후 증후군 1명, 뇌종양 1예를 대상으로 하여, 뇌의 routine 자기공명 영상과 함께 Gd-DTPA 0.1 mmol/kg를 급속 주사 후 자화율 대조 EPI 영상을 얻었다. 영상 기기는 Magnetom Vision(Siemens Medical Systems, Erlangen, Germany)이며, EPI 영상 지표들은 TR/TE는 0.8/29 msec, slice 두께 6 mm, slice 수 10, 화소수 128 $\times$ 128, FOV 215 $\times$ 215 mm, 영상획득 1 회, 1회 검사시간 1.32 초, 검사수 30 회로서, 총 검사시간은 40 초였다. 검사 후 영상처리(post processing)는 Magnetom Vision의 VB31D 자체 프로그램을 이용하였는데, 2-score를 이용한 관류영상은 조영제 유입전 영상들, 조영제 최대 유입기 영상들, 그리고 조영제 배출기 영상들 4-5 회를 각각 한 군으로 하여, Z-score 1.2에서 2.0 사이에서 여러번 반복하여 영상을 재구성하였다. 감산에 의한 역동영상은 조영제 도달 전의 영상으로부터 조영제 유입 후의 영상을 차례로 빼어서 영상을 재구성하였으며, 이들 영상을 재정리하여 각 단면의 시간 경과에 따른 관류 양상을 연속하여 관찰하였다 두 방법에 의한 영상 재구성은 각각 약 10분 정도가 소요되었다.

  • PDF

회전자계 역수신 코일을 이용한 관벽의 자기공명영상

  • 문치웅;조종운;백문영;조지연;박청수;신운재;이현용;은충기
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.176-176
    • /
    • 2001
  • 목적: 기존의 역수신코일(inside-out receiver coil)로 관벽의 MR 영상을 얻을 때 영상영역이 좁고 수신감도가 불균일한 단점을 보완하면서 신호대 잡음비(S/N ratio)도 높일 수 있는 회전자계역수 신코일(quadratic inside-out receiver coil)의 개발을 목적으로 한다. 대상 및 방법: 8극형코일, 선형자계수신코일, 회전자계수신코일에 대하여 컴퓨터 모의실험으로 영상영역 및 감도의 균일성을 비교하였다. 회전자계수신코일은 안장 모양을 한 두 개의 선형자계코일이 서로 간섭이 일어나지 않도록 수직 방향으로 배열된 구조를 갖도록 하였다. 지름 3 cm 크기로 각 코일을 제작하였으며 지름 20 cm의 원통 중앙에 내경 4 cm의 관이 있는 팬텀을 만들어 MnC1$_2$를 섞은 물을 채운 다음 1.5T 초전도 MRI 장치와 0.3T 영구자석 MRI 장치에서 팬텀의 관벽 영상을 얻었다. 본 실험을 시행한 1.5T 장치의 구조 때문에 회전자계코일의 두 안장코일을 결합하는 회로를 제작하여 사용하였고 0.3T에서는 장치에 내장된 결합회로를 사용하였다. 또한 포르말린 용액에 보관된 소의 대장 조직 단면 영상을 FOV 10-12 cm로 얻어 회전자 계안장코일의 성능을 평가하였다.

  • PDF

PIV Measurements of Ventilation Flow from the Air Vent of a Real Passenger Car (거대 화상용 PIV 시스템을 이용한 실차 내부 공기벨트 토출흐름의 속도장 측정 연구)

  • Lee, Jin-Pyung;Kim, Hak-Lim;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.7 no.1
    • /
    • pp.3-8
    • /
    • 2009
  • Most vehicles have a heating, ventilating and air conditioning (HVAC) device to control the thermal condition and to make comfortable environment in the passenger compartment. The improvement of ventilation flow inside the passenger compartment is crucial for providing comfortable environment. For this, better understanding on the variation of flow characteristics of ventilation air inside the passenger compartment with respect to various ventilation modes is strongly required. Most previous studies on the ventilation flow in a car cabin were carried out using computational fluid dynamics (CFD) analysis or scale-down water-model experiments. In this study, whole ventilation flow discharged from the air vent of a real passenger car was measured using a special PIV (particle image velocimetry) system for large-size FOV (field of view). Under real recirculation ventilation condition, the spatial distributions of stream-wise turbulence intensity and mean velocity were measured in the vortical panel-duct center plane under the panel ventilation mode. These experimental data would be useful for understanding the detailed flow structure of real ventilation flow and validating numerical predictions.

A Study on Projective Calibration for Arbitrary Display Surface using Digital Moire Method. (Digital Moire를 이용한 임의의 영사면에 대한 투영보정에 관한 연구)

  • 유원재;김도훈;강영준;백성훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.292-295
    • /
    • 2003
  • Moire topography method is a well-known non-contacting 3-D measurement method. the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using digital projection moire topography is very attractive because of its high measuring speed and high sensitivity. In this study, digital two-wavelength phase shilling moire is applied to the entertainment fields. recently. as promoting the growth of the VR-Game, display devices which attract public attention such as HMD or Projector are being appeared in order to deliver effectively the absorption sense. this study realized the Auto-calibrating system for arbitrary display surface using digital moire method which satisfied the shape measurement of display surface and the request of FOV(Field of View) output. also when large screen wasn't prepared, this auto-calibrating system was applied to enjoy games or movies at home with a projector and walls

  • PDF

Conceptual Study of Brain Dedicated PET Improving Sensitivity

  • Shin, Han-Back;Choi, Yong;Huh, Yoonsuk;Jung, Jin Ho;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.236-240
    • /
    • 2016
  • The purpose of this study is to propose a novel high sensitivity neuro-PET design. The improvement of sensitivity in neuro-PET is important because it can reduce scan time and/or radiation dose. In this study, we proposed a novel PET detector design that combined conical shape detector with cylindrical one to obtain high sensitivity. The sensitivity as a function of the oblique angle and the ratio of the conical to cylindrical portion was estimated to optimize the design of brain PET using Monte Carlo simulation tool, GATE. An axial sensitivity and misplacement rate by penetration of ${\gamma}$ rays were also estimated to evaluate the performance of the proposed PET. The sensitivity was improved by 36% at the center of axial FOV. This value was similar to the calculated value. The misplacement rate of conical shaped PET was about 5% higher than the conventional PET. The results of this study demonstrated the conical detector proposed in this study could provide subsequent improvement in sensitivity which could allow to design high sensitivity PET for brain imaging.

MIRIS 우주관측 카메라 Noise Test

  • Park, Yeong-Sik;Lee, Dae-Hui;Mun, Bong-Gon;Jeong, Ung-Seop;Lee, Chang-Hui;Park, Seong-Jun;Lee, Deok-Haeng;Pyo, Jeong-Hyeon;Nam, Uk-Won;Park, Jang-Hyeon;Lee, Seung-U;Matsumoto, Toshio;Han, Won-Yong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.126.2-126.2
    • /
    • 2011
  • MIRIS(Multipurpose InfraRed Imaging System)는 과학기술위성 3호의 주 탑재체이며 2012년 하반기 발사예정이다. MIRIS 우주관측 카메라는 0.9-2.0 ${\mu}m$ 영역에서 3.67 deg. x 3.67 deg. FOV로 우리 은하평면 survey 관측과 우주배경복사(CIB) 관측을 수행할 것이다. 현재 MIRIS는 비행모델 개발 마무리 단계에 있으며, 검교정 시험, 열-진공 시험, 진동 시험 등을 수행하고 나면 2011년 말 위성 본체와의 조립을 진행할 것이다. 망원경이 복사냉각(Passive Cooling)을 통해 200K 이하로 냉각되면, dewar에 설치된 소형 냉각기를 가동하여 적외선 센서를 90K 정도로 냉각한다. MIRIS 우주관측카메라에는 PICNIC($256{\times}256$ pixel) 센서를 사용하였고, 상온과 냉각된 상태에서의 노이즈 특성을 측정하였다. PICNIC 센서와 dewar내부를 냉각하기 위해 RICOR사의 K-508 micro stirling cooler를 사용하는데, cooler가 동작하면서 전자부에 영향을 주어 주된 잡음으로 나타남을 확인하였다. Cooler에서 발생하는 잡음을 최소화 하기위해 fanout B/D와 LVPS 부분을 개선하였으며, 본 발표에서는 잡음 측정 결과에 대해 논의 하고자 한다.

  • PDF

An algorithm for autonomous driving on narrow and high-curvature roads based on AVM system. (좁고 곡률이 큰 도로에서의 자율주행을 위한 AVM 시스템 기반의 알고리즘)

  • Han, Kyung Yeop;Lee, Minho;Lee, SunWung;Ryu, Seokhoon;Lee, Young-Sup
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.11a
    • /
    • pp.924-926
    • /
    • 2017
  • 본 논문에서는 좁고 곡률이 큰 도로에서의 자율 주행을 위한 AVM 시스템 기반의 알고리즘을 제안한다. 기존의 전방을 주시하는 모노/스테레오 카메라를 이용한 차선 인식 방법을 이용한 자율주행 알고리즘은 모노/스테레오 카메라의 제한된 FOV (Field of View)로 인해 좁고 곡률이 큰 도로에서의 자율 주행에 한계가 있다. 제안하는 알고리즘은 AVM 시스템을 기반으로 하여 이 한계를 극복하고자 한다. AVM 시스템에서 얻은 영상을 차선의 색상 정보를 이용해 차선의 영역을 이진화 한다. 이진화 영상으로부터, 차량의 뒷바퀴 주변의 관심영역을 시작으로 재귀적 탐색법을 이용하여 좌, 우 차선을 검출한다. 검출된 좌, 우 차선의 중앙선을 차량의 경로로 삼고 조향각을 산출해 낸다. 제한하는 알고리즘을 실제 차량에 적용시킨 실험을 수행하였고, 운전면허 시험장의 코스를 차선의 이탈없이 주행 가능함을 실험적으로 확인하였다.