• Title/Summary/Keyword: FNAB

Search Result 36, Processing Time 0.078 seconds

Thyroglobulin Measurement in Fine Needle Aspirates for Diagnosing Cervical Lymphnode Metastasis from Differentiated Thyroid Malignancy (갑상선암의 경부 림프절 전이 진단을 위한 미세침세척액 티로글로불린 측정법)

  • Ko, Hee-Young;Kim, Seung-Su;Lee, Chun-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.181-185
    • /
    • 2010
  • Purpose: Several studies report that detection of thyroglobulin (Tg) in fine-needle aspiration (FNA) biopsy washout fluid from lymph nodes identifies recurrences or metastases of differentiated papillary thyroid cancer (DPTC) in the neck with higher sensitivity and specificity than fine-needle aspiration cytology (FNAC). We evaluate the diagnostic efficacy and usefulness of Tg measurement in FNA washout fluid (FNA-Tg) and compare with FNAC. Materials and Methods: Forty-eight FNA samples of 37 patients who undergone ultrasonography to detect cervical lymph node metastasis of DPTC, were included for this study. Lymph node metastasis was confirmed by histopathologic examination or long-term imaging follow-up. Sensitivity, specificity and accuracy of FNA-Tg and FNAC were calculated. In 34 patients, we evaluated diagnostic accuracy of FNA-Tg according to the presence or absence of Tg antibody. Results: Sensitivity, specificity and accuracy of FNAC were 75.0%, 97.2% and 91.7%, respectively, and those of FNA-Tg were 100%, 88.9% and 91.7%, respectively. The presence of Tg antibody was not relevant to the diagnostic accuracy of FNA-Tg. Conclusion: FNA-Tg is a as accurate as FNAC with higher sensitivity. FNA-Tg and FNAC are complement techniques for diagnosing lymph node metastasis of DTPC.

  • PDF

The Usefulness of FNAB for the Diagnosis of Thoracic Surgical Disease (흉부외과 질환의 진단시 FNAB 의 유용성과 객담세포검사 및 기관지 내시경 검사와의 비교 고찰)

  • 유정훈
    • Journal of Chest Surgery
    • /
    • v.23 no.6
    • /
    • pp.1225-1232
    • /
    • 1990
  • From March 1986 to June 1990, the percutaneous Fine Needle Aspiration Biopsy[FNAB] of 102 thoracic lesions were performed with Westcott needle [slotted 20G or 22G thin needle], for the purpose of identifying and diagnosing thoracic lesions. There were 94 lung lesions [67 malignant tumors, 27 benign lesions] and 8 mediastinal and chest wall lesions. The results of FNAB were compared with sputum cytology and bronchoscopic examinations. The sputum cytologic examinations were performed in 54 cases of malignant lung tumor and the malignant cell was found at the 18 cases [33%]. We bronchoscopic examinations were performed in 24 cases and the malignant cell was found at the 12 cases [55%]. The positive diagnostic rate of malignancy was 100% by FNAB. Among them, 55 cases [82%] were diagnosed by cytologic examinations and 43 cases[64%] by both. The specific diagnoses for benign lung lesions in 15 cases[55%] and for mediastinal and chest well lesions in 5 cases[62%]. The 7 patients[6.9%] developed the pneumothorax and 5 of them required the treatment. Therefore, the FNAB of thoracic lesions may be a preferred diagnostic method because of its safety, simplicity and accuracy.

  • PDF

Efficacy of Fine Needle Aspiration Biopsy in Parotid Gland Tumors (이하선 종양에서 세침흡인검사의 유용성)

  • Lee, Chang-Hee;Lee, Hyun-Sub;Jin, Sung-Min;Lee, Sang-Hyuk;Pyo, Jung-Soo;Sohn, Jin-Hee
    • Korean Journal of Head & Neck Oncology
    • /
    • v.27 no.2
    • /
    • pp.204-209
    • /
    • 2011
  • Background and Objectives : The usefulness of fine needle aspiration biopsy(FNAB) for diagnosis of parotid gland tumors is controversial, because of the generalized belief requiring surgery for most parotid tumors. The aim of this study was to evaluate the efficacy of FNAB for diagnosis in parotid gland tumors. Material and Methods : FNAB was performed in 91 patients who underwent parotid surgery at Kangbuk Samsung Hospital from January 2007 to December 2010. The result of FNAB, 11 malignancies and 75 benign tumors and 5 non-neoplasms were analyzed and compared with the final histopathologic diagnoses. Sensitivity, specificity, accuracy, positive predictive value(PPV), and negative predictive value(NPV) were calculated using final histopathologic diagnosis of the surgical specimen as the standard diagnostic reference for comparative analysis. Results : 86 specimens(94.5%) were suitable for evaluation. We compared the result of FNAB and the final histopathology in 79(89.4%) cases. The sensitivity, specificity, accuracy, PPV, and NPV of FNAB for detecting pleomorphic adenoma was 95.8%, 88.4%, 92.3%, 90.2%, and 95.0%. In Warthin's tumor, results were 86.4%, 94.2%, 92.3%, 82.6%, and 95.6%. Among 11 patients who were diagnosed with malignancy on final histopathologic report, only 3(30%) patients were diagnosed with the same as on FNAB, the other 8 patients were initially diagnosed incorrectly as benign tumors in FNAB. There were no complications related to FNAB. Conclusion : Diagnostic accuracy for FNAB in benign parotid tumors was high. However, in malignant tumors, FNAB shows low diagnostic usefulness compared with benign tumors. FNAB can be effective and safe diagnostic technique for evaluating the benign parotid glands tumors.

Comparison between Radiological and Invasive Diagnostic Modalities in Diagnosis of Breast Cancer

  • Onur, Gulcin Ozkan;Tarcan, Ercument;Onur, Asim;Can, Huseyin;Atahan, Murat Kemal;Yigit, Seyran Ceri;Cakalagaoglu, Fulya
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.10
    • /
    • pp.4323-4328
    • /
    • 2015
  • Background: Breast cancer is the most common cause of deaths of cancer in women. Nowadays, following completion of imaging methods, mainly fine needle aspiration biopsy (FNAB) and core biopsy methods have been used for establishing cytopathological diagnosis although discussions regarding superiority continue. Materials and Methods: Those with a complaint of "mass in breast" along with those diagnosed to have a mass as a result of routine physical examination among all patients applying to our clinic between 01.01.2009 and 31.12.2011 were retrospectively assessed. Totals of 146 and 64 patients with complete radiological observation who had undergone FNAB and core biopsies, respectively, were evaluated. Postoperative pathological results of patients of both groups receiving surgery were also taken into consideration. All results were compared in terms of false positivity/negativity, sensitivity/specifity, surgery types and distribution of postoperative results with regard to diagnoses along with those of malignant/benign masses with regard to quadrants determined. Results: Diagnostic malignancy power of mammographic BIRADS classification was 87.3%. However, the value was 75% in the core biopsy group. Sensitivity and specifity following comparison of FNAB and postoperative pathology results of those receiving surgery were 85.4% and 92.9% while they were 93.5% and 100% in the core biopsy group. Diagnostic malignancy power, calculated by determining AUC in ROC analysis, of FNAB was 89.1% while that of core biopsy was 96.7%. Conclusions: It was shown that core biopsy is superior to FNAB in terms of sensitivity, specificity and accurate histopathological classification. However; quick, cheap and basic diagnosis by means of FNAB should not be ignored. Sensitivity of FNAB is rather high in experienced hands and furthermore it would be expected to be lower than with core biopsy.

Clinical Value of fine Needle Aspiration Biopsy in Head and Neck Masses (두경부 종물에 대한 세침천자생검의 임상적 의의)

  • 김성근;강성호;김경래;이형석;김선곤
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1993.05a
    • /
    • pp.103-103
    • /
    • 1993
  • Fine needle aspiration biopsy(FNAB) is widely used in screening of head and neck(H&N) masses because it has high accuracy and few damage. The 235 cases of FNAB were performed on patient with H&N mass at the Department of Otolaryngology, Hanyang University Hospital during 1 years, from March 1985 to February 1992. The 188 of 235 were proven histologically, clinically. The results obtained were as follows ; 1) FNAB for malignant H&N mass shows sensitivity of 81.5% specificity of 96.8%. 2) FNAB for malignant LN shows sensitivity of 86.0%, specificity of 88.9%. 3) FNAB for salivary gland shows sensitivity of 66.7%, specificity 81.8%. 4) FNAB for soft tissues, bone, and intraoral lesions shows sensitivity of 90%, specificity 95.8%. 5) FNAB for tuberculosis shows false negative of 55.2%. 6) The result of FNAB was not closely related with location or size of neck nodes.

  • PDF

Diagnostic Value of Ultrasound-Guided Fine Needle Aspiration Biopsy in Malignant Thyroid Nodules: Utility for Micronodules

  • Unal, Betul;Sezer, Cem
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.20
    • /
    • pp.8613-8616
    • /
    • 2014
  • Background: The diagnostic approach to thyroid nodules involves ultrasound-guided fine needle aspiration biopsy (US-FNAB). We especially aimed to evaluate the contribution and the place of US-FNAB in preoperative evaluation of the malignant cases and draw attention to discordant cases diagnosed with papillary thyroid microcarcinoma (PTMC). Materials and Methods: A total of 276 cases were retrospectively reviewed who were subsequently diagnosed with a malignancy and who underwent US-FNAB. Results: Some 45 were found to have previously undergone the US-FNAB procedure. Of the patients in whom the surgical specimen was diagnosed with a malignancy, 21 (46.7%) were diagnosed as malignant or suspicious for malignancy, and 24 (53.3%) were concluded as benign or insufficient for diagnosis. Patients with the diagnosis of PTMC outnumbering the others was a striking finding (11 cases, 24%). Conclusions: We suggest performing repeat aspiration biopsy considering sampling errors in cases where inconsistency exists between clinical findings and cytological results in thyroid nodules smaller than 10 mm in diameter and with suspicious findings on ultrasonography.

Two Cases of Unilateral Thyroid Hematoma Inducing Airway Distress after Fine Needle Aspiration Biopsy (세침흡인검사 후 호흡곤란을 동반한 일측성 갑상선 혈종 2례)

  • Byun, Jang-Yul;Kwon, Kye-Won;Koh, Yoon-Woo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.23 no.1
    • /
    • pp.54-57
    • /
    • 2007
  • Fine needle aspiration biopsy(FNAB) has been used for many decades in the diagnosis of benign and malignant tumors of thyroid gland. Complications of thyroid fine-needle aspiration biopsy(FNAB) are extremely rare. Hematoma formation is the most commonly encountered complication. However, massive intrathyroid unilateral hemorrhage and hematoma formation inducing upper airway distress rarely occurs. Here, we report two cases diagnosed as having hematoma that caused upper airway distress after FNAB for thyroid nodule.

Performance Indices of Needle Biopsy Procedures for the Assessment of Screen Detected Abnormalities in Services Accredited by BreastScreen Australia

  • Farshid, Gelareh;Sullivan, Thomas;Jones, Simeon;Roder, David
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.24
    • /
    • pp.10665-10673
    • /
    • 2015
  • Background: We wished to analyse patterns of use of needle biopsy procedures by BreastScreen Australia (BSA) accredited programs to identify areas for improvement. Design: BSA services provided anonymous data regarding percutaneous needle biopsy of screen detected lesions assessed between 2005-2009. Results: 12 services, from 5 of 7 Australian states and territories provided data for 18212 lesions biopsied. Preoperative diagnosis rates were 96.84% for lesion other than microcalcification (LOTM) and 93.21% for microcalcifications. At surgery 97.9% impalpable lesions were removed at the first procedure. Of 11548 Microcalcification (LOTM) biopsied, 46.9% were malignant. The final diagnosis was reached by conventional core biopsy (CCB) in 72.46%, FNAB in 21.33%, VACB in 1.69% and open biopsy in 4.52% of lesions. FNA is being limited to LOTM with benign imaging After FNAB, core biopsy was required for 38% of LOTM. In LOTM the mean false positive rate (FPR) was 0.36% for FNAB, 0.06% for NCB and 0% for VACB. Diagnostic accuracy was 72.75% for FNAB and 92.1% for core biopsies combined. Of 6441 microcalcifications biopsied 2305 (35.8%) were malignant. Microcalcifications are being assessed primarily by NCB but 6.57% underwent FNAB, 45.6% of which required NCB. False positive diagnoses were rare. FNR was 5% for NCB and 1.53% for VACB. Diagnostic accuracy was 73.52% for FNAB, 86.29% for NCB and 88.63% for VACB. Only 8 of 12 services had access to VACB facilities. Conclusions: BSA services are selecting lesions effectively for biopsy and are achieving high preoperative diagnosis rates. Gaps in the present accreditation standards require further consideration.

Correlation of Serum Thyroglobulin and Thyroglobulin in the Wash out of the Needle in Thyroid Cancer (갑상선암에서의 혈중 Thyroglobulin 농도와 침생검 검체 Washout Solution의 Thyroglobulin 농도와의 상관관계)

  • An, Jae-Seok;Kim, Ji-Na;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.152-155
    • /
    • 2009
  • Purpose: The most widely accepted tool for follow up management of thyroid cancer patients is serum thyroglobulin (Tg) measurement, but its value is limited by the interference of anti-thyroglobulin antibodies (anti-Tg Ab). Recently thyroglobulin measurement in the wash out of fine-needle aspiration biopsy specimens (Tg-FNAB) is frequently used for differential diagnosis of recurrences/metastases. The aim of this study was the investigation of the diagnostic utility of Tg-FNAB compared with serum Tg. Materials and Methods: We enrolled 41 consecutive patients with thyroid cancer who were evaluated for Tg-FNAB between January 2007 and February 2008 retrospectively. We ruled out 6 patients who anti-Tg Ab positive (${\geq}$100 U/mL) in the RIA (BRAHMS anti-Tgn RIA 100Det; BRAHMS Aktiengesell schaft, Berlin, Germany). Serum Tg and Tg-FNAB were measured by immunoradiometric assay (BRAHMS Tg pluS RIA 100 Det; BRAHMS Aktienge sellschaft, Berlin, Germany). We evaluated for Tg-FNAB compared with serum Tg and corresponding cytological smear. To compare the values of the two the t-test was used. Results: Tg-FNAB values were significantly higher (median 1,060 ng/mL, range 0.2~434,000 ng/mL) than serum Tg (median 2.5 ng/mL, range 0.9~131 ng/mL) (p=0.0394). The rate of correspondence with Tg-FNAB between cytological result was 87.9% and 65.9% in the case of serum Tg. Tg-FNAB was positive in 28 (24 with positive and 4 with suspicious cytology). Of the remaining 13 patients with negative Tg-FNAB, 1 had suspicious and 12 had unsuspicious cytology. serum Tg was positive in 26 (17 with positive and 3 with suspicious and 6 with unsuspicious cytology), Of the remaining 15 patients with negative serum Tg, 8 was positive in cytological result and 1 had suspicious and 6 had unsuspicious cytology. Conclusions: Tg-FNAB measurement is more accurate with high sensitivity (87.9%) than serum Tg (65.9%). The Tg-FNAB was a useful predictor for detecting recurrences/metastases with serum Tg.

  • PDF

Cytologic Features of Well Differentiated Hepatocellular Carcinoma (분화도가 높은 간세포암종의 세침흡인 세포학적 소견 - 비종양성 병변과의 감별 -)

  • Khang, Shin-Kwang;Lee, Seung-Sook;Cho, Kyung-Ja;Ha, Hwa-Jeong
    • The Korean Journal of Cytopathology
    • /
    • v.8 no.1
    • /
    • pp.1-10
    • /
    • 1997
  • The fine needle aspiration biopsy(FNAB) has become a popular method to diagnose mass lesions of the liver. Although many reports have listed FNAB criteria to be used to diagnose hepatocellular carcinoma(HCC), a diagnostic dilemma still exists at the extreme ends of the spectrum, particularly for well differentiated HCC. The authors reviewed a series of FNAB specimens of the liver to distinguish well differentiated HCC from nonneoplastic liver. Fifteen cytologic features were examined in this study: high cellularity, large sheet formation, trabecular pattern, acinar pattern, dispersed pattern, irregular arrangement, increased nuclear/cytoplasmic ratio, naked nuclei, irregular chromatin, irregular nuclear contour, multinucleation, uniform macronucleoli, multiple nuclei, uniform small cytoplasm and monotony of atypia. These features were examined in a series of 76 FNAB specimens. Fifty two specimens were from patients with HCC and 24 specimens were from patients with nonneoplastic lesion or tumors other than HCC containg adequate amount of nonneoplastic hepatocytes in smear. All specimens were coded as to the presence or absence of the above cytologic features. With the use of step-wise logistic regression analysis, three features were identified as the key cytologic features predictive of HCC: irregular chromatin, monotony of atypia and absence of large sheet formation. When these criteria were used, the sensitivity diagnosing HCC by FNAB was 94.2%, specificity 100%, positive predictive value 100% and negative predictive value was 88.9%.

  • PDF