• Title/Summary/Keyword: FEP film

Search Result 14, Processing Time 0.024 seconds

A Study on the Way to Increase Heat Resistance of Teflon Type Thin Film Electret Applied for Industrial Sensor (산업용 센서에 사용하는 Teflon계 박막 일렉트렛의 내열성 향상에 관한 연구)

  • 김병수;이덕출
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.3
    • /
    • pp.60-63
    • /
    • 2003
  • For the increase the charge stability of teflon electrets for used at uncomfortable industrial circumstances with high temperature or humidity, We made an investigation into double layer effect of teflon electrets. Teflon AF film was spincoated on FEP film and then the charge storage property of AF/FEP dual film was investigated to be compared with FEP film. It was found that the AF/FEP dual film has higher surface potential than FEP film on the repeated charging and annealing process. It seems that AF/FEP dual film has higher thermal stability than FEP film through TSC measurement. If the investigations of the double layer effect of Teflon film carried out more closely with it's molecular structures and surface conditions, it may be effectively improved the stability of charge storage.

The Thermal Stability of Teflon AF/FEP Double Layer Film Electret (Teflon AF/FEP 이중 필름 일렉트렛트의 열적 안정성)

  • 김병수;이덕출
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.8
    • /
    • pp.693-699
    • /
    • 2003
  • To improve thermal stability of Teflon FEP which is the most widely used materials for electret application, Teflon AF film of 1 $\mu\textrm{m}$ thick was spin coated on FEP film and the charge storage properties were investigated. The surface potential depend on aging temperature. Thermal Stimulated Current(TSC), Atomic Force Microscopy(AFM), and Fourier Transform-Infrared Spectroscope(FT-lR) measurements were carried out. It is shown that the AF/FEP dual film have more higher electrical property and thermal stability than that FEP film have caused by charge stored at interface of AF and FEP.

Fabrication of 3D Multilayered Microfluidic Channel Using Fluorinated Ethylene Propylene Nanoparticle Dispersion (불소화 에틸렌 프로필렌 나노 입자 분산액을 이용한 3차원 다층 미세유체 채널 제작)

  • Min, Kyoung-Ik
    • Korean Chemical Engineering Research
    • /
    • v.59 no.4
    • /
    • pp.639-643
    • /
    • 2021
  • In this study, fluorinated ethylene propylene (FEP) nanoparticle as an adhesive for fabricating a three-dimensional multilayered microfluidic device was studied. The formation of evenly distributed FEP nanoparticles layer with 3 ㎛ in thickness on substrates was achieved by simple spin coating of FEP dispersion solution at 1500 rpm for 30 s. It is confirmed that FEP nanoparticles transformed into a hydrophobic thin film after thermal treatment at 300 ℃ for 1 hour, and fabricated polyimide film-based microfluidic device using FEP nanoparticle was endured pressure up to 2250 psi. Finally, a three-dimensional multilayered microfluidic device composed of 16 microreactors, which are difficult to fabricate with conventional photolithography, was successfully realized by simple one-step alignment of FEP coated nine polyimide films. The developed three-dimensional multilayered microfluidic device has the potential to be a powerful tool such as high-throughput screening, mass production, parallelization, and large-scale microfluidic integration for various applications in chemistry and biology.

A Study on the Graft Distribution of the FEP-g-PSSA Membranes Prepared by a Simultaneous Irradiation Method (방사선 동시조사법에 의해 제조된 FEP-g-PSSA 막의 그래프트 분포에 관한 연구)

  • Ko, Beom-Seok;Shin, Jun-Hwa;Sohn, Joon-Yong;Nho, Young-Chang;Kang, Phil-Hyun
    • Polymer(Korea)
    • /
    • v.33 no.3
    • /
    • pp.268-271
    • /
    • 2009
  • In this study, the distribution behaviors of the polystyrene sulfonic acid (PSSA) grafting polymer across the FEP-g-PSSA membranes prepared by a simultaneous irradiation method, were investigated by analyzing the cross-section of the membranes with a SEM-EDX instrument. The effects of irradiation conditions such as the degree of grafting, FEP film thickness, and grafting solvent on the distribution of the grafting polymer were mainly studied in this experiment. The results indicate that to obtain the evenly grafted FEP-g-PSSA membranes, the higher degree of grafting is required as the film thickness increases, and the lower dose rate are more effective than the higher dose rate at the given dose.

A study on Improvement of Electric charge storage characteristics using $Teflon^{(R)}FEP$ film ($Teflon^{(R)}FEP$ film을 사용한 전하보존특성 향상에 관한 연구)

  • Kim, Seong-Jun;Lee, Hyeon-Seok;Kwon, Jeong-Yeol;Kim, Ji-Kyun;Lee, Heon-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.539-540
    • /
    • 2006
  • In this paper, We examine that characteristics of formative electret with polymer film and electric charge storage using grid corona discharge. compound polymer of fluorine resin used for material in electret because of high electric charge accumulation, excellent electrical and physical characteristic. All experiments were carried out with circular samples of $Teflon^(R)FEP$ film, 12.5[${\mu}m$] thick. As experiment variables, we used voltage, electrode thickness, discharge electrode gap, and discharge time. According to this variables, we studied on characteristics of formative electret and electric charge storage. Additionally we make a comparative study of the result between the grid corona discharge and needle electrode discharge.

  • PDF

The Charge Storage Property of Teflon AF/FEP Dual Film Electret (Teflon AF/FEP 이중 필름 일렉트렛의 전하저장 특성)

  • Kim, B.S.;Lee, B.J;Shin, B.K.;Yuk, J.H.;Park, K.B.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1413-1414
    • /
    • 2003
  • 일렉트렛을 이용한 전자제품의 시공정에 주로 이용되고 있는 Teflon FEP 일렉트렛의 전하 저장 특성을 개선하기 위하여 FEP 필름 위에 Teflon AF 1${\mu}m$를 적충한 후 그 전기적 특성을 분석하였다. AF/FEP 이중 필름을 음극 코로나 방전에 의해 하전시켰으며, 반복 하전 및 열처리에 따른 표면전위 변화를 관찰하였다.

  • PDF

Theoretical Calculation and Experimental Verification of the Hf/Al Concentration Ratio in Nano-mixed $Hf_xAl_yO_z$ Films Prepared by Atomic Layer Deposition

  • Kil, Deok-Sin;Yeom, Seung-Jin;Hong, Kwon;Roh, Jae-Sung;Sohn, Hyun-Cheol;Kim, Jin-Woong;Park, Sung-Wook
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.5 no.2
    • /
    • pp.120-126
    • /
    • 2005
  • We have proposed a characteristic method to estimate real composition when multi component oxide films are deposited by ALD. Final atomic concentration ratio was theoretically calculated from the film densities and growth rates for $HfO_2$ and $Al_2O_3$ using ALD processed HfxAhOz mms.W e have transformed initial source feeding ratio during deposition to fins] atomic ratio in $Hf_xAl_yO_z$ films through thickness factors ($R_{HFO_2}$ ami $R_{Al_2O_3}$) ami concentration factor(C) defined in our experiments. Initial source feeding ratio could be transformed into the thickness ratio by each thickness factor. Final atomic ratio was calculated from thickness ratio by concentration factor. It has been successfully confirmed that the predicted atomic ratio was in good agreement with the actual measured value by ICP-MS analysis.

A Study on the Charging and discharging current of corona charged Teflon-FEP film (코로나 대전된 Teflon-FEP의 충.방전 전류 특성에 관한 연구)

  • Cheong, Ki-Seok;Lee, Seung-Woo;Park, Kwang-Hyun;Lee, Deok-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1988.05a
    • /
    • pp.60-62
    • /
    • 1988
  • In this study, the characteristic of charging current which flows into the polymer by applying the corona discharge carriers on the polymer surface was measured, so as to investigate the phenomenon of charge injection and movement if injected charge on polymer. Also. the characteristics of discharge current which flows by shorting both sides of corona charged polymers were measured. Experimental results are as follows; The amount of charges injected by corona discharge vary according to the state of surface and the type of carriers, and then the charging current varies according to the properties of injected carriers.

  • PDF

Study on the Physical Properties of the Gamma Beam-Irradiated Teflon-FEP and PET Film (Teflon-FEP 와 PET Film 의 감마선 조사에 따른 물리적 특성에 관한 연구)

  • 김성훈;김영진;이명자;전하정;이병용
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.11-21
    • /
    • 1998
  • Circular metal electrodes were vacuum-deposited with chromium on the both sides of Teflon-FEP and PET film characteristic of electret and the physical properties of the two polymers were observed during an irradiation by gamma-ray from $\^$60/Co. With the onset of irradiation of output 25.0 cGy/min the induced current increased rapidly for 2 sec, reached a maximum, and subsequently decreased. A steady-state induced current was reached about in 60 second. The dielectric constant and conductivity of Teflon-FEP were changed from 2.15 to 18.0 and from l${\times}$l0$\^$-17/ to 1.57${\times}$10$\^$-13/ $\Omega$-$\^$-1/cm$\^$-1/, respectively. For PET the dielectric constant was changed from 3 to 18.3 and the conductivity from 10$\^$-17/ to 1.65${\times}$10$\^$-13/ $\Omega$-$\^$-1/cm$\^$-1/. The increase of the radiation-induced steady state current I$\^$c/, permittivity $\varepsilon$ and conductivity $\sigma$ with output(4.0 cGy/min, 8.5 cGy/min, 15.6 cGy/min, 19.3 cGy/min) was observed. A series of independent measurements were also performed to evaluate reproducibility and revealed less than 1% deviation in a day and 3% deviation in a long term. Charge and current showed the dependence on the interval between measurements, the smaller the interval was, the bigger the difference between initial reading and next reading was. At least in 20 minutes of next reading reached an initial value. It may indicate that the polymers were exhibiting an electret state for a while. These results can be explained by the internal polarization associated with the production of electron-hole pairs by secondary electrons, the change of conductivity and the equilibrium due to recombination etc. Heating to the sample made the reading value increase in a short time, it may be interpreted that the internal polarization was released due to heating and it contributed the number of charge carriers to increase when the samples was again irradiated. The linearity and reproducibility of the samples with the applied voltage and absorbed dose and a large amount of charge measured per unit volume compared with the other chambers give the feasibility of a radiation detector and make it possible to reduce the volume of a detector.

  • PDF

Feasibility Study of Parallel- Plate Detector Using Dielectric film for 6 MV X-ray (6MV X-선 검출특성 조사를 위하여 유전체 필름을 이용하여 제작한 평행판 검출기의 유용성)

  • 조문준;김용은;이병용;김정기;임상욱;김현수;김기환
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.105-111
    • /
    • 2004
  • The parallel plate detector with dielectric film for dosimetry was designed to measure detection characteristic of 6 MV X-ray with medical linear accelerator. PTFE film was inserted into FEP films that are made by two one-side metal coated materials for ion source. The thicknesses of PTFE dielectric film was 100 ${\mu}{\textrm}{m}$ and the thickness of FEP dielectric film was 100 ${\mu}{\textrm}{m}$, respectively. This detector was fixed by two acrylic plate for physical hardness ad geometrical consistency. The geometrical condition for measurement with parallel-plate for detector was below; SSD=100 cm and the 5 cm depth between detector and phantom surface The major parameter of detector characteristics such as zero drift current, leakage current, charge response by applied voltage, reproducibility, linearity, TMR measurement, dose rate effect were measured. The zero drift currents are 8.3 pA and leakage currents are 10 pA. The charge response of applied voltage is showing linearity in 414 voltage. The measurement deviation of reproducibility in this detector is within 1% for dose and the linearity of applied dose shows in this detector. The TMR curves in phantom between this parallel plate detector and reference detector are matched within 3% deviation from maximum dose depth to 7.5 cm depth. It is considered that this dosimetric system is satisfactory for the purpose of the constancy check of the 6 MV x-ray from medical linear accelerator.

  • PDF