• 제목/요약/키워드: FEMA

검색결과 188건 처리시간 0.038초

Effects of near-fault records characteristics on seismic performance of eccentrically braced frames

  • Eskandari, Reyhaneh;Vafaei, Davoud
    • Structural Engineering and Mechanics
    • /
    • 제56권5호
    • /
    • pp.855-870
    • /
    • 2015
  • In this paper the effects of fling-step and forward-directivity on the seismic performance of steel eccentrically braced frames (EBFs) are addressed. Four EBFs with various numbers of stories (4-, 8-, 12- and 15-story) were designed for an area with high seismic hazard. Fourteen near-fault ground motions including seven with forward-directivity and seven with fling-step effects are selected to carry out nonlinear time history (NTH) analyses of the frames. Furthermore, seven more far-field records were selected for comparison. Findings from the study reveal that the median maximum links rotation of the frames subjected to three set of ground motions are in acceptable range and the links completely satisfy the requirement stated in FEMA 356 for LS performance level. The arrival of the velocity pulse in a near-fault record causes few significant plastic deformations, while many reversed inelastic cycles result in low-cycle fatigue damage in far-fault records. Near-fault records in some cases are more destructive and the results of these records are so dispersed, especially the records having fling-step effects.

격간벽 아파트 건물의 지진해석 (Seismic Analyses of Staggered Wall Apartment Buildings)

  • 전용;공지은;김진구
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2010년도 정기 학술대회
    • /
    • pp.2-5
    • /
    • 2010
  • 최근 공동주택 거주자의 공간변화 욕구에 대응하기 위하여 가변성 평면이 가능한 구조시스템에 대한 연구가 활발히 진행되고 있다. 이에 따라 건식벽체 구조시스템, 복합 무량 벽체 구조시스템, 격간벽 시스템 등 구조적으로 안정성이 확보되면서 공간가변성이 뛰어난 구조시스템이 대안으로 제시되었다. 본 연구에서는 격간벽 시스템의 지진해석을 통해 내진성능을 평가하였다. 비선형 정적해석 및 동적해석 결과 격간벽 시스템은 벽식 구조시스템에 비하여 초과강도가 작고, 연성이 다소 감소하지만 FEMA-356에서 정하는 붕괴 방지 수준을 만족하여 충분한 내진성능을 보유한 것으로 나타났다.

  • PDF

FMEA를 적용한 전자 의료기기의 신뢰성 평가 체계 구축 (Construction of Reliability Evaluation System for Electronic Medical Devices using FEMA)

  • 이하용;양해술;김혁주;이정림
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2006년도 추계학술발표대회
    • /
    • pp.535-538
    • /
    • 2006
  • FMEA(Failure Mode & Effect Analysis)는 발생 가능한 잠재 고장의 형태와 그 영향을 평가하고 고장을 예방할 수 있도록 표를 이용하여 체계적으로 접근하는 방법이다. FMEA를 활용하여 전자 의료기기의 신뢰성을 평가할 수 있는 방안에 대한 연구를 통해 의료기기의 신뢰성 향상을 위한 체계적인 접근이 요구된다. 본 연구에서는 소프트웨어의 신뢰성을 평가하기 위한 체계를 구축하기 위해 FMEA 기법을 근간으로 하여 전자 의료기기의 신뢰성 평가 체계 구축에 적용할 수 있는 방안을 수립하고자 한다.

  • PDF

Effect of connection rotation capacities on seismic performance of IMF systems

  • Han, Sang Whan;Moon, Ki-Hoon;Ha, Sung Jin
    • Earthquakes and Structures
    • /
    • 제10권1호
    • /
    • pp.73-89
    • /
    • 2016
  • The seismic performance of moment frames could vary according to the rotation capacity of their connections. The minimum rotation capacity of moment connections for steel intermediate moment frames (IMF) was defined as 0.02 radian in AISC 341-10. This study evaluated the seismic performance of IMF frames with connections having a rotation capacity of 0.02 radian. For this purpose, thirty IMFs were designed according to current seismic design provisions considering different design parameters such as the number of stories, span length, and seismic design categories. The procedure specified in FEMA P695 was used for conducting seismic performance evaluation. It was observed that the rotation capacity of 0.02 radian could not guarantee the satisfactory seismic performance of IMFs. This study also conducted seismic performance evaluation for IMFs with connections having the rotation capacity of 3% and ductile connections for proposing the minimum rotation capacity of IMF connections.

내진성능평가시 횡보강근이 없는 RC 보-기둥 접합부의 전단내력 평가 (Seismic Assessment of Shear Capacity of RC Beam-Column Joints Without Transverse Re-bars)

  • 이영욱
    • 한국지진공학회논문집
    • /
    • 제23권5호
    • /
    • pp.249-259
    • /
    • 2019
  • To study the seismic resistance of the shear capacity of the RC beam-column joints of two-story and four-story RC buildings, sample buildings are designed with ordinary moment resisting frame. For the shear capacity of joints, the equations of FEMA 356 and NZ seismic assessment are selected and compared. For comparison, one group of buildings is designed only for gravity loads and the other group is designed for seismic and gravity loads. For 16 cases of the designed buildings, seismic performance point is evaluated through push-over analysis and the capacity of joint shear strength is checked. Not only for the gravity designed buildings but also for seismic designed buildings, the demand of joint shear is exceeding the capacity at exterior joints. However, for interior joint, the demand of joint shear exceeds the capacity only for one case. At exterior joints, the axial load stress ratio is lower than 0.21 for gravity designed buildings and 0.13 for seismic designed buildings.

Assessment of seismic design coefficients for composite special moment frames with reinforced concrete columns and steel beams: Evaluation of code recommendations

  • Elmira Tavasoli Yousef Abadi;Mohammad T. Kazemi
    • Steel and Composite Structures
    • /
    • 제50권6호
    • /
    • pp.643-658
    • /
    • 2024
  • The main aim of this study is to quantify the code seismic design coefficients of the RCS system, which consisted of reinforced concrete columns and steel beams, based on the FEMA P-695 methodology. The underlying intention is to evaluate the seismic performance of the RCS system at the system level rather than the connection level. A set of 24 archetype buildings with a various number of stories, beam span lengths, gravity load levels, and seismic load levels are selected and designed based on the prevailing code requirements. Nonlinear analytical models are developed and validated by experimental tests. The pushover and response history dynamic analyses are conducted to evaluate the required data in the performance quantification process. The results show that the design coefficients suggested by the code are acceptable. However, the level of conservatism is very high. Thus, it is possible to use a larger R-factor in the design process or make some relaxations in the design requirements related to this structural system.

전산플랫폼을 이용한 초고층구조물의 감쇠장치 최적화 설계 (Optimization Design of Damping Devices for a Super-Tall Building Using Computational Platform)

  • 정보라;이상현;정란;최현철
    • 한국전산구조공학회논문집
    • /
    • 제28권2호
    • /
    • pp.145-152
    • /
    • 2015
  • 본 연구에서는 파라매트릭 모델링 기법을 통해 다양한 대안을 고려할 수 있도록 개발된 StrAuto(이하 전산플랫폼)을 이용하여 감쇠장치에 따른 감쇠비 증가 효과와 풍하중 저감효과를 평가하였다. 비정형 초고층구조물의 수많은 구조시스템 대안 선정을 지원하는 전산플랫폼은 설계자 또는 엔지니어에게 초기 대안을 결정하는데 있어 유용한 도구가 된다. 감쇠장치의 용량 및 추가 요구감쇠비의 크기를 산정하는 과정에서 중요한 원 구조물의 감쇠비에 대한 추정은 풍하중에 대한 실계측 자료를 기반으로 수행된 국내외 관련 연구의 결과를 사용하였다. 감쇠장치는 층간 설치형 수동형 감쇠장치와 질량형 능동형 감쇠장치 두 가지 유형을 고려하였다. 감쇠장치에 의해 추가되는 감쇠비는 FEMA에서 제안한 식을 이용하여 등가 정적 해석을 수행하여 산정하였다. 전산 플랫폼 내부에 감쇠장치의 용량을 최적화하는 알고리즘을 내장함으로써 최적의 감쇠장치 설계안을 자동적으로 도출할 수 있다. 감쇠장치 설치에 따른 물량저감 효과는 풍하중 저감계수로 평가될 수 있으며, 455m 높이의 초고층구조물을 대상으로 제안한 방법의 유효성을 검증하였다. 제안한 방법을 사용하여 비선형 시간이력 해석을 통해 얻어진 지붕층 변위와 층별 전단력을 근사적으로 추정할 수 있음을 확인하였다.

성능기반설계에 기초한 성능영향인자 변화에 따른 기둥의 거동분석 (Behavior of Columns Due to Variation of Performance Influencing Factors Based on Performance Based Design)

  • 윤성환;최민철;강윤식;박대효
    • 콘크리트학회논문집
    • /
    • 제22권4호
    • /
    • pp.489-498
    • /
    • 2010
  • 철근 콘크리트 구조물의 명확한 성능평가를 수행하기 위해 재료 및 구조적 특성이 구조물에 미치는 영향에 대한 분석이 필요하다. 구조물의 성능에 영향을 미치는 성능영향인자는 구조물의 재료적 특성인 콘크리트 강도, 종방향주철근, 횡구속 철근, 구조적 특성인 형상비, 축하중에 대하여 총 5가지로 정의하였다. 각각의 성능영향인자 변화에 따른 고유치 해석과 비선형 정적해석을 수행하여 각각의 성능영향인자들이 구조물의 항복 변위와 항복 기저전단력 및 연성비의 정적성능에 미치는 영향을 분석하였다. 또한 비선형 정적해석의 결과를 이용하여 FEMA-440에서 제안된 수정된 능력스펙트럼법을 이용하여 성능평가를 수행하였고, 이에 따라 구조물의 성능점을 도출하였으며 각각의 성능영향인자가 미치는 영향을 분석하였다. 성능영향인자 변화에 따른 해석 결과, 고유치해석과 비선형 정적해석의 따른 고유주기와 연성비는 구조적 특성이 재료적 특성에 비해 구조물에 더 큰 영향을 미치는 것으로 나타났고, 그 중 형상비의 영향이 가장 크게 작용하였으며, 수정된 능력스펙트럼법을 이용한 성능평가 결과, 고유주기와 연성비와 마찬가지로 구조적 특성 중 형상비의 영향이 가장 크게 작용하였다.

HAZUS를 이용한 충남지역의 지진피해 연구 (The Seismic Hazard Study on Chung-Nam Province using HAZUS)

  • 강익범;박정호
    • 한국방재학회 논문집
    • /
    • 제2권2호
    • /
    • pp.73-83
    • /
    • 2002
  • 미국 재난 관리청인 FEMA에서 개발한 지진피해예측 software인 HAZUS를 충청남도 지역에 적용하여 건물 인구 시추자료 등 1차적인 data를 가지고 지진재해규모를 산정해 보았다. 이번 연구에서는 과거 충남지역에서의 역사지진기록과 계기지진기록을 조사하여 가상최대지진 및 지진재래주기별 최대가속도 값을 계산한 후 지진피해를 산정하였다. 홍성에서 가상지진(지진규모 6.0)을 발생시켜 결정론적 방법에 의해 충남지역 용도별 구조별 건물과 인명피해를 계산하여 지진피해를 예측한 결과 주거용 상가용 콘크리트 건물은 모두 홍성군 예산군 보령시가 피해가 가장 심한 지역으로 나타났으며 인명피해는 통원 및 입원치료에 해당되는 부상정도가 홍성 및 예산에서 군 인구당 각각 1.1명 및 0.4명꼴로 나타났으며 확률론적 방법(5,000년 재래주기)에 의해 충남지역 용도별 구조별 건물과 인명피해를 계산하여 지진피해를 예측한 결과 대체로 주거 상가 콘크리트 건물피해는 공주지역의 지진피해가 높은 것으로 나타났으며 인명피해는 통원 및 입원치료에 해당되는 부상정도가 공주시 논산시가 가장 심한 지역으로 나타났으며 각각 시 인구당 0.1명꼴 0.15명꼴로 나타났다.

지진재해예측을 위한 HAZUS와 ShakeMap의 한반도에서의 적용가능성 연구 (A Preliminary Study of the Global Application of HAZUS and ShakeMap for Loss Estimation from a Scenario Earthquake in the Korean Peninsula)

  • 강수영;김광희;김동춘;유해수;민동주;석봉출
    • 한국지리정보학회지
    • /
    • 제10권1호
    • /
    • pp.47-59
    • /
    • 2007
  • 미국의 FEMA와 NIBS에서 개발한 HAZUS-MH는 GIS를 기반시스템으로 하는 자연재해 전후의 피해정도를 평가 및 분석하는 재해정보시스템이다. 본 연구에서는 HAZUS-MH를 한반도의 일부지역에 시범적으로 적용하고, 그 운영에서의 효율성 및 문제점을 제시한다. 한반도 지진관련 연구자료 및 역사지진자료를 토대로 경상남북도를 적용대상지역으로 선정하였다. 연구지역에서 발생한 지진 중 인명피해가 있었던 서기 779년 경주에서 발생한 규모 6.7의 지진을 선택하여, 이 지진이 2000년도에 재발생하였다는 가정 하에 HAZUS를 적용하였다. 이 시스템을 적용하여 연구지역의 지진재해를 예측할 때 USGS에서 제공하는 ShakeMap의 지진동자료를 이용하였다. 이러한 연구를 통하여 미국의 HAZUS가 한반도에도 적용가능하다는 것을 알 수 있었으며, 한반도 전 지역에서 발생하는 모든 자연재해에 대하여 HAZUS를 적용한다면 우리나라의 자연재해에 의한 피해를 예측하고 대응하는데 효율적으로 이용될 수 있을 것으로 기대된다.

  • PDF