• Title/Summary/Keyword: FEM simulations

Search Result 308, Processing Time 0.023 seconds

A Study about Effectiveness and Usefulness of a FEM Slug Test Model (유한 요소기법을 이용한 Slug시험 모델의 타당성 및 유용성 연구)

  • 한혜정;최종근
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.7 no.2
    • /
    • pp.89-96
    • /
    • 2000
  • Slug tests are the most widely used field method for quantification of hydraulic conductivity of porous media. Well recovery is affected by well casing, borehole radii, screened length, hydraulic conductivity, and specific storage of porous media. In this study, a new slug tests model was developed through finite element approximation and the validity and usefulness of the model were tested in various ways. Water level fluctuation in a well under slug test and cons-equent groundwater flow in the surrounding porous medium were appropriately coupled through estimation of well-flux using an iteration technique. Numerical accuracy of the model was verified using the Cooper et al. (1967) solution. The model has advantages in simulations for monitored slug tests, partial penetration, and inclusion of storage factor. Volume coverage of slug tests is significantly affected by storage factor. Magnitude and speed of propagation of head changes from a well increases as storage factor becomes low. It will be beneficial to use type curves of monitored head transients in the surrounding porous formation for estimation of specific storage. As the vertical component of groundwater flow is enhanced, the influence of storage factor on well recovery decreases. For a radial-vertical flow around a partially penetrated well, deviations between hydraulic estimates by various methods and data selection of recovery curve are negligible on practical purposes, whereas the deviations are somewhat significant for a radial flow.

  • PDF

Design of Integrated LTCC Front-End Module using Measurement-Based Behavioral Model for IEEE 802.11a WLAN Applications (측정기반 거동 모델을 이용한 IEEE 802.11a 무선랜용 LTCC Front-End 모듈 집적화 설계)

  • Han, A-Reum;Yoon, Kyung-Sik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.5A
    • /
    • pp.490-496
    • /
    • 2007
  • This paper describes the design and implementation of an integrated LTCC front-end module for the IEEE802.11a WLAN applications by performing the behavioral-level simulation using measurement-based behavioral model. To meet the IEEE802.11a WLAN standard, a system transmitting 1024 symbols through 64-QAM process at the rate of 54Mbps should be implemented and nonlinear properties are confirmed by simulations of ACPR and EVM in this circumstance. The right offsets of ACPR which are 30MHz, 20MHz, and 11MHz distant from the center frequency of 5.8GHz are 49.36dBc, 36.90dBc, and 24.58dBc, respectively. The left offsets are 50.14dBc, 30.04dBc, and 28.85dBc, respectively and EVM is 2.94%. The size of the module implemented with LTCC five-layer substrates is $13.4mm{\times}14.2mm$. The measured characteristics of the transmitter show P1dB of 16.2dBm and power gain of 16.73dB. Those of the receiver exhibit the small signal gain of 16.24dB and noise figure of 7.83dB.

Shear Capacity Evaluation of Steel Plate Anchors Using Folded Steel Plate in AU-composite Beam (절곡 강판을 이용한 AU합성보 덮개형 강재앵커의 전단성능 평가)

  • Lim, Hwan Taek;Choi, Byong Jeong
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.5
    • /
    • pp.389-400
    • /
    • 2017
  • Based on U-shaped composite beam, the new form of AU-composite beam were developed to create economical and efficient components reducing the cost and shortening the length of construction work. Because the U-shaped sections are open and needs to be fixed by topping concrete securely. Therefore, it is required to maintain the U-shaped sections in a structure and to work in the safe condition through construction. It also requires accessories that resist the horizontal shear force for synthesis between the top and bottom of the U-shaped section. To reinforce these shortcomings, a shear connector has been developed with various purposes of steel plate anchors. In this study, the steel plate anchors were directly tested and the shear force was evaluated by the horizontal shear force. The experiment was divided into two types, depending on the applicable deck plates. As a result of the experiment, the continuous type specimens showed greater resistance in both strength and displacement than the ones of stud anchor specimen. In discontinuous type case, due to shear simulations and simple element analysis, the less increase the ratio of width to height and the more shear strength decreased. Thus, the shear strength equation of the stud anchor was modified to suggest the new shear strength based on the testing results.

A Study on the Effect of Ice Impact Forces on an Ice-Strengthened Polar Class Ship After a Collision with an Iceberg (빙산과의 충돌 시 충격 하중이 극지운항선박의 내빙 구조에 미치는 영향에 관한 연구)

  • Kim, Sunghyug;Luo, Yu;Shi, Chu;Lee, Chang-Hyun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.1
    • /
    • pp.40-46
    • /
    • 2017
  • Shipping activities have become possible in the Arctic Ocean due to melting ice by global warming. An increasing number of vessels are passing through the Arctic Ocean consequently bringing concerns of ship-iceberg collisions. Thus, most classification societies have implemented regulations to determine requirements for ice strengthening in ship structures. This paper presents the simulation results of an ice-strengthened polar class ship after an iceberg collision. The ice-strengthened polar class ship was created in accordance with the Unified Requirements for a Polar-Ship (IACS URI). An elastic-perfect plastic ice model was adopted for this simulation with a spherical shape. A Tsai-Wu yield surface was also used for the ice model. Collision simulations were conducted under the commercial code LS-DYNA 971. Hull deformations on the ice-strengthened foreship structure and collision interaction forces have been analysed in this paper. A normal-strength ship structure in an iceberg collision was also simulated to present comparison results. Distinct differences in structural strength against ice impact forces were shown between the ice-strengthened and normal-strength ship structures in the simulation results. About 1.8 m depth of hull deformation was found on the normal ship, whereas 1.0 m depth of hull deformation was left on the ice-strengthened polar class ship.

Stress Distribution in Microvascular Anastomotic Coupler (AnaFix®) Micropins with Respect to the Fillet Radius (필렛효과에 따른 미세혈관 문합커플러(AnaFix®) 마이크로핀의 응력분포)

  • Jee, Dae-Won;Kim, Cheol-Woong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.11
    • /
    • pp.1139-1145
    • /
    • 2011
  • An automated anastomotic ring-pin system consisting of both the anastomotic ring-pin system and the coupler device has eliminated the drawbacks of the suture method. High density polyethylene (HDPE), a material with outstanding biocompatibility and injection molding capability, was used in the ring. SUS316 stainless steel, Ti-6Al-4Nb, Ti-6Al-4V, and unalloyed titanium were used in FEM simulations of the micropin. The authors categorized the microvascular anastomotic ring micropins into short neck (SN) and long neck (LN) groups in order to evaluate the effect of the micropin's fillet radius and neck length on the von Mises stress. The micropins were further divided into those with and without fillet. On the basis of the fillet radius rate (FRR), which represents the rate of change in the von Mises stress with respect to the availability and shape of the fillet, and the neck length rate (NLR), which represents the rate of change in the von Mises stress with respect to changes in the length of the neck within the fillet shape, it can be concluded that the SN-3 neck design is the most stable.

Development of a Software to Evaluate the CPES(Cable Penetration Fire Stop) System in Nuclear Power Plane I (원자력발전소 케이블관통부 충전시스템 평가용 소프트웨어 개발 I)

  • 윤종필;권성필;조재규;윤인섭
    • Fire Science and Engineering
    • /
    • v.18 no.1
    • /
    • pp.24-30
    • /
    • 2004
  • In this work the dynamic heat transfer occurring in a cable penetration fire stop system built in the firewall of nuclear power plants is three-dimensionally investigated to develop a test-simulator that can be used to verify effectiveness of the sealants. Here was carried out an experiment to observe the heat transfer in the cable penetration fire stop system made of DOW CORNING products. The dynamic heat transfer occurring in the fire stop system is formulated in a parabolic partial differential equation subjected to a set of initial and boundary conditions. And it was modeled, simulated, and analyzed. The simulation results were illustrated in three-dimensional graphics and were compared with experimental data. Through the simulations, it was shown clearly that the temperature distribution was influenced very much by the number, position, and temperature of the cable streams. It also was found that the dynamic heat transfer through the cable streams was one of the most dominant factors, and the feature of heat conduction could be understood as an unsteady-state process. It is certain that these numerical results are useful for making a performance-based design for the cable penetration fire stop system.

Numerical Simulation of Depth-Averaged Flow with a CDG Finite Element Method (CDG 유한요소법을 이용한 수심적분 흐름의 수치모의)

  • Kim, Tae Beom;Choi, Sung-Uk;Min, Kyung Duck
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5B
    • /
    • pp.447-457
    • /
    • 2006
  • This paper presents a numerical model for the simulations of 2D depth-averaged flows. The shallow water equations are solved numerically by the Characteristic Dissipative Galerkin (CDG) finite element method. For validation, the developed model is applied to the hydraulic jump. The computed results are compared with the analytical solution, revealing good agreement. In addition, flow in a contracting channel showing standing waves is simulated. The calculated water surface profile appears to be qualitatively consistent with the observed data. The foregoing results indicate that the model is capable of simulating the abrupt change in flow field. Next, the model is applied to the flow in a $180^{\circ}$ curved channel. The simulated results show that the velocity near the inner bank is faster than that near the outer bank and the water depth near the inner bank is shallower than that near the outer bank. However, the simulated results show that the velocity distribution across the channel is almost uniform in the bend except the reach close to the end of the bend. This is due to the limitation of the governing equations in which the transverse convection of momentum by the secondary flows along a channel bend is not taken into account.

Numerical Analysis of Collapse Behavior in Industrial Stack Explosive Demolition (산업용 연돌 발파해체에서 붕괴거동에 관한 수치해석적 연구)

  • Pu-Reun Jeon;Gyeong-Jo Min;Daisuke Fukuda;Hoon Park;Chul-Gi Suk;Tae-Hyeob Song;Kyong-Pil Jang;Sang-Ho Cho
    • Explosives and Blasting
    • /
    • v.41 no.3
    • /
    • pp.62-72
    • /
    • 2023
  • The aging of plant structures due to industrialization in the 1970s has increased the demand for blast demolition. While blasting can reduce exposure to environmental pollution by shortening the demolition period, improper blasting design and construction plans pose significant safety risks. Thus, it is vital to consider optimal blasting demolition conditions and other factors through collapse behavior simulation. This study utilizes a 3-D combined finite-discrete element method (FDEM) code-based 3-D DFPA to simulate the collapse of a chimney structure in a thermal power plant in Seocheon, South Korea. The collapse behavior from the numerical simulation is compared to the actual structure collapse, and the numerical simulation result presents good agreement with the actual building demolition. Additionally, various numerical simulations have been conducted on the chimney models to analyze the impact of the duct size in the pre-weakening area. The no-duct, duct, and double-area duct models were compared in terms of crack pattern and history of Z-axis displacement. The findings show that the elapse-time for demolition decreases as the area of the duct increases, causing collapse to occur quickly by increasing the load-bearing area.