I selected the theory of blood stasis and wetness-phlegm among the major 4 causes of Joong Poong(C.V.A.)(wind. fire. deficiency of vital energy and wetness-phlegm) and recent etiology of blood stasis. An experimental studies were done to investigate the effects of Danggieum (removing blood stasis and promoting blood circulation) and Ijintang(dissipating wetness-phlegm) on thrombosis and elevated blood viscosity. The results were as follows; 1. The number of platelets were significantly increased in only Danggieum group. 2. Related to the amount of fibrinogen. only Danggieum group revealed some increase. but both groups revealed no significance. 3. Related to the prothrombin time. Danggieum and Ijintang groups had significant decrease. but Danggieum group revealed more significance. 4. Related to the degree of concentration of FDP, only Danggieum group had significant decrease. 5. Whole blood viscosity and plasma viscosity in lower shear rates. both groups of Danggieum and Ijintang had significant decrease. 6. Related to the amount of RBC. both groups of Danggieum and Ijintang had significant decrease. 7. Related to the change of hematocrit. only Danggieum group, and the change of hemoglobin. only Ijintang group had significant decrease. 8. Related to the change of body temperature. only Ijintang group had significant raise. 9. Related to the changes of WBC. glucose, albumin, total protein and body weight. Danggieum and Ijintang groups had each increase or decrease. but no significance. According to the above results, Danggieum had more significant effect than Ijintang on the thrombosis. and Ijintang had more significant effect than Danggieum on the elevated blood viscosity. And it is considered that it might be more effective in treating Joong-Poong(C.V.A) to take medicines regarding patient's constitution and symptoms as well as the causes of Joong-Poong(C.V.A)
Thromboelastography(TEG) is the unique measure that gives rapid information about the whole clotting process. Simplifying the diagnosis of coagulopathy during operations, TEG can provide an adequate therapy for postoperative bleeding. Remarkable improvement in hemostasis after cardiopulmonary bypass(CPB) has been achieved by the treatment with proteinase inhibitor aprotinin, but the hemostatic mechanism of aprotinin during CPB is still unclear. This study was designed to evaluate the effects of aprotinin on coagulation system during CPB by using TEG. Forty patients who underwent CPB were divided into two groups: aprotinin(2u 106 kallikrein inhibition units, as a single dose into the cardiopulmonary bypass priming solution) treatment group(male 14, female 8, mean age=50.Byears) and no aprotinin treatment(control) group(male 10, female 8, mean age=53.4 years). TEG, activated clotting time, prothrombin time, activated partial thromboplastin time, platelet counts, fibrinogen an (ibrinogen degradation product(FDP) concentrations were checked before and after CPB(30 minutes after neutralization of heparin effect by protamine sulfate). There was no significant difference in other conventional coagulation tests of two groups except postcardiopulmonary bypass FDP concentration in control group, which was significantly increased compared to that in aprotinin group(p<0.05). In TEG variables of both groups, clot formation time(K) and alpha $angle(\alpha^{\circ})$ were significantly increased and decreased, respectively, after CPB(p<0.05), but fibrinolytic index(LYS60) was not changed during CPB. In aprotinin group, reaction time(R) was decreased significantly after CPB(p<0.05) but maximum amplitude(MA) was not changed(p>0.05). On the contrary, R was not changed markedly but MA was decreased significantly in control group after CPB(p<0.05). This result shows that main change in coagulation system during CPB is not hyperfibrinolysis but cecrease in clot strength by platelet dys unction, and the main effect of aprotinin during cardiopulmonary bypass is the maintenance of clot strength to the pre-CPB level by the preservation of platelet function.
Purpose: The purpose of this study was to compare the marginal fit of three-unit zirconia fixed dental prostheses (FDPs) fabricated using CAD/CAM and MAD/MAM system. Materials and methods: Dentiform maxillary central and lateral incisor were prepared for 3-unit FDP and fixed in yellow stone. This model was duplicated to epoxy resin die. On the resin die, fifteen 3-unit FDPs were fabricated. Metal-ceramic group was three-unit metal-ceramic FDPs, $Everest^{(R)}$ group was zirconia three-unit FDPs fabricated using the $Everest^{(R)}$ system (Kavo Dental GmbH, Biberach, Germany) and $Rainbow^{TM}$ group was zirconia three-unit FDPs fabricated using the $Rainbow^{TM}$ system (Dentium Co. Inc., Seoul, South Korea). They were cemented to resin dies with adhesive resin cement. After removing pontics, each retainers were separated and observed under measuring machine (Presize 440C) and analyzed through one-way ANOVA and Duncan test (${\alpha}$ = .05). Results: Mean values and standard deviations of marginal gap dimensions in each group for three-unit FDPs were $78.5{\pm}11.05\;{\mu}m$ for the metal-ceramic group, $59.30{\pm}11.63\;{\mu}m$ for the $Everest^{(R)}$ group and $70.34{\pm}13.98\;{\mu}m$ for the $Rainbow^{TM}$ group. Conclusion: 1. The $Everest^{(R)}$ group in comparison with metal-ceramic group showed better marginal fit, which had significant differences P<.05. 2. The mean marginal gap values between $Everest^{(R)}$ and $Rainbow^{TM}$ group did not showed significant differences (P>.05). 3. The mean marginal gap values between $Rainbow^{TM}$ group and metal-ceramic group did not showed significant differences (P>.05). 4. The mean marginal gaps of each group were within clinically acceptable range ($120\;{\mu}m$).
E. tarda, a fish pathogen, can survive in seawater under relatively high salt conditions as well as in fish under physiological salt conditions. Bacterial growth under different salt concentrations may influence the expression of genes involved in bacterial structure and physiology. The growth rate of E. tarda culture in high salt (3.5% NaCl) was similar to that in low salt (1.0% NaCl, physiological salt concentration). Interestingly, the strain moved much faster in low salt conditions than in high salt conditions. Electron microscopic observation demonstrated that the bacterial cells grown in high salt had less or no flagellation. Obvious flagellation was observed in the parental strain E. tarda CK41 grown in low-salt condition. Two putative genes coding flagellin were identified in the E. tarda genome sequences. The amino acid sequence comparison of each gene revealed 93% identities. A flagellin gene was PCR amplified and cloned into a cloning vector. Using an E. coli protein expression system, a part of flagellin protein was overexpressed. Using the purified protein, an anti-flagellin antibody was raised in the rabbit. Immunoblot analyses with flagellin specific antibody demonstrated that E. tarda CK41 expressed falgellin in low salt conditions, which is consistent with the results seen in motility assay and microscopic observation. This is the first report of salt regulated flagella expression in E. tarda.
Although Korea is a top market sharing and world leading producer and developer of flat panel display devices, relevant recycling technology is not up to her prestigious status. Besides, most of the waste glass arising from flat panel displays is currently land-filled. The present paper mainly reviews on development of recycling systems for waste TFT-LCD glass from end-of-life LCD TVs and monitors and TFT-LCD process waste of crushed glass particles with target end uses of raw material for high strength concrete pile and glass fibers, respectively. Waste LCD glass was recycled to fabricate ingredients for high strength concrete piles with enhanced physical properties and spherical foam products. The waste LCD glass recycling technology is already developed to fabricate long and short fibers at commercial level. In view of these, future R & D on waste LCD glass materials is to be directed toward implementation of commercial materials recycling system therefrom.
Applying perceptual hierarchy of facial feature points, a neural network model for recognizing facial expressions was designed. Input data were convolution values of 150 facial expression pictures by Gabor-filters of 5 different sizes and 8 different orientations for each of 39 mesh points defined by MPEG-4 SNHC (Synthetic/Natural Hybrid Coding). A set of multiple regression analyses was performed with the rating value of the affective states for each facial expression and the Gabor-filtered values of 39 feature points. The results show that the pleasure-displeasure dimension of affective states is mainly related to the feature points around the mouth and the eyebrows, while a arousal-sleep dimension is closely related to the feature points around eyes. For the filter sizes. the affective states were found to be mostly related to the low spatial frequency. and for the filter orientations. the oblique orientations. An optimized neural network model was designed on the basis of these results by reducing original 1560(39x5x8) input elements to 400(25x2x8) The optimized model could predict human affective rating values. up to the correlation value of 0.886 for the pleasure-displeasure, and 0.631 for the arousal-sleep. Mapping the results of the optimized model to the six basic emotional categories (happy, sad, fear, angry, surprised, disgusted) fit 74% of human responses. Results of this study imply that, using human principles of recognizing facial expressions, a system for recognizing facial expressions can be optimized even with a a relatively little amount of information.
Application areas of Knowledge Discovery in Database(KDD) have been expanded to many R&D management processes including technology trends analysis, forecasting and evaluation etc. Established research field such as informetrics (or scientometrics) has utilized techniques or methods of KDD. Various systems have been developed to support works of analyzing large-scale R&D related databases such as patent DB or bibliographic DB by a few researchers or institutions. But extant systems have some problems for korean users to use. Their prices is not moderate, korean language processing is impossible, and user's demands not reflected. To solve these problems, Korea Institute of Science and Technology Information(KISTI) developed stand-alone type information analysis system named as KnowledgeMatrix. KnowledgeMatrix system offer various functions to analyze retrieved data set from databases. KnowledgeMatrix's main operation unit is composed of user-defined lists and matrix generation, cluster analysis, visualization, data pre-processing. Matrix generation unit help extract information items which will be analyzed, and calculate occurrence, co-occurrence, proximity of the items. Cluster analysis unit enable matrix data to be clustered by hierarchical or non-hierarchical clustering methods and present tree-type structure of clustered data. Visualization unit offer various methods such as chart, FDP, strategic diagram and PFNet. Data pre-processing unit consists of data import editor, string editor, thesaurus editor, grouping method, field-refining methods and sub-dataset generation methods. KnowledgeMatrix show better performances and offer more various functions than extant systems.
Park, Joungsoon;Suh, Sang-Il;Oh, Yeonsu;Hyun, Changbaig
Journal of Veterinary Clinics
/
v.32
no.1
/
pp.5-8
/
2015
D-dimer is a fibrin degradation product (FDP), a small protein fragment present in the blood after a blood clot is degraded by fibrinolysis. D-dimer concentration is widely used for determining thrombosis and thromboembolism. Because one major cause of thromboembolism is congestive heart failure in human, we investigated the degree and risk of thromboembolism in dogs with different stage of congestive heart failure caused by chronic mitral valvular insufficiency (CMVI). The plasma level of d-dimer was evaluated in 20 healthy dogs and 30 dogs with different stage of congestive heart failure caused by CMVI. The d-dimer concentrations were measured by a commercialized assay kit. The plasma levels of d-dimer were not significantly different between healthy and CMVI dogs. Furthermore, there was no association of d-dimer concentrations to left atrium to aorta (LA/Ao) ratio, left ventricular dimension at diastole to aorta (LVIDd/Ao) ratio and severity of heart failure in our study population. Our study results implied that the degree of thromboembolism in canine heart failure might be minimal or the plasma d-dimer test might not be reliable for detecting thromboembolism in dogs.
Purpose: In hand injury, pedicle is usually damaged by avulsion injury or crushing injury. Because of postoperative pedicle obliteration, it is often hard to save the injured hand and fingers, even after successful replantation. The author introduces three cases of extensive hand injury, and successful results after applicatoin of multiple venous grafts to these patients. Methods: In all cases there was no circulation in any finger. In the first case, some vessels were extracted, so venous graft was applied to two sites of severely damaged venous sites. In the second case, venous grafts were applied to all four digital arteries of all fingers except thumb which got severely crushed, and two sites of dorsal veins. In the third case, venous graft was applied to all four digital arteries of all five fingers, and two sites of dorsal veins and palmar veins each. Results: In all cases, survival of hands and fingers was successful. In the second case, however, amputation in thumb and little finger at DIP joint level was inevitable, because of its severe damage, and the large dorsal defect on index finger was filled with DIEP free flap. Thumb was reconstructed with toe-to-thumb free flap, and additional debulking procedures and contracture release is furtherly needed. In the first case, additional surgery was done, as FDP tendon got re-ruptured, but in long term follow-up, satisfactory range of motion was attained. In the third case, FTSG on dorsal skin region was planned. as flap on dorsal area got partial necrosis. Conclusion: In hand injury, there are many structures to be repaired, but sometimes venous graft is avoided for its long operating time. Even though the length of damaged vessel is enough for anastomosis, the endothelium is often damaged (zone of injury). In extensive hand injury, successful reconstruction would be possible with active venous graft to all vessels suspicious for damage.
Purpose: This in vitro study aimed to compare the trueness of 3-unit fixed dental provisional prostheses (FDPs) fabricated by three different additive manufacturing and subtractive manufacturing procedures. Methods: A reference model with a maxillary left second premolar and the second molar prepped and the first molar missing was scanned for the fabrication of 3-unit FDPs. An anatomically shaped 3-unit FDP was designed on computer-aided design software. 10 FDPs were fabricated by subtractive (MI group) and additive manufacturing (stereolithography: SL group, digital light processing: DL group, liquid crystal displays: LC group) methods, respectively (N=40). All FDPs were scanned and exported to the standard triangulated language file. A three-dimensional analysis program measured the discrepancy of the internal, margin, and pontic base area. As for the comparison among manufacturing procedures, the Kruskal-Wallis test and the Mann-Whitney test with Bonferroni correction were evaluated statistically. Results: Regarding the internal area, the root mean square (RMS) value of the 3-unit FDPs was the lowest in the MI group (31.79±6.39 ㎛) and the highest in the SL group (69.34±29.88 ㎛; p=0.001). In the marginal area, those of the 3-unit FDPs were the lowest in the LC group (25.39±4.36 ㎛) and the highest in the SL group (48.94±18.98 ㎛; p=0.001). In the pontic base area, those of the 3-unit FDPs were the lowest in the LC group (8.72±2.74 ㎛) and the highest in the DL group (20.75±2.03 ㎛; p=0.001). Conclusion: A statistically significant difference was observed in the RMS mean values of all the groups. However, in comparison to the subtractive manufacturing method, all measurement areas of 3-unit FDPs fabricated by three different additive manufacturing methods are within a clinically acceptable range.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.