• Title/Summary/Keyword: FDG-PET/CT

Search Result 415, Processing Time 0.029 seconds

When We Consider Neurolymphomatosis in Patient with Lumbosacral Plexopathy with an Extreme Leg Pain? (통증을 동반한 신경총병증에서 언제 신경림프종증을 고려해야 하는가?)

  • Ahn, Jun Young;Seok, Hyun;Kim, Sang-Hyun;Kim, Hyun Jung;Cho, Yeon Hee;Oh, Back Min;Lee, Seung Yeol
    • Clinical Pain
    • /
    • v.20 no.1
    • /
    • pp.53-57
    • /
    • 2021
  • We report a case of neurolymphomatosis of lumbosacral plexus. A 63-year-old man, who had no past history except for diabetes mellitus, complained of severe pain and weakness on left lower extremity. Idiopathic lumbosacral plexopathy was diagnosed by electromyography. There were no abnormal findings except for FDG-PET/CT and MRI. They showed high uptake and thickening lesion in sciatic nerve and sacral plexus. However, about 7 months later, mass like lesion in left thigh was detected by FDG-PET/CT and MRI. Also, multiple hypermetabolic lesions were found in brain. Through brain biopsy, diffuse large B-cell lymphoma was confirmed. When a patient with idiopathic lumbosacral plexopathy complains of severe pain, it is necessary to consider FDG-PET/CT and MRI to differentiate neurolymphomatosis, even in patients who have no past history of lymphoma before. Especially, if FDG-PET/CT and MRI show sciatic and/or lumbosacral plexus lesion, neurolymphomatosis of lumbosacral plexus should be considered.

Evaluation of Reasonable $^{18}F$-FDG Injected Dose for Maintaining the Image Quality in 3D WB PET/CT (PET/CT 검사에서 영상의 질을 유지하기 위한 적정한 $^{18}F$-FDG 투여량의 평가)

  • Moon, A-Reum;Lee, Hyuk;Kwak, In-Suk;Choi, Sung-Wook;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.36-40
    • /
    • 2011
  • Purpose: $^{18}F$-FDG injected dose to the patient is quite different between the recommended dose from manufacturer and the actual dose applied to each of hospitals. injection of inappropriate $^{18}F$-FDG dose may not only increase the exposed dose to patients but also reduce the image quality. we thus evaluated the proper $^{18}F$-FDG injected dose to decrease the exposed dose to patients considering the image quality. Materials And Methods: NEMA Nu2-1994 phantom was filled with $^{18}F$-FDG increasing hot cylinder radioactivity concentration to 1, 3, 5, 7, 9 MBq/kg based on the ratio of 4:1 between the hot cylinder and background activity. after completing the transmission scan using ct, emission scan was acquired in 3D mode for 2 minutes 30 seconds/bed. ROI was set up on hot cylinder and background radioactivity region. after measuring $SUV_{max}$ those regions, then analyzed SNR at the points. clinical experiment has been conducted the object of patients who have came to smc from november 2009 to august 2010, 97 patients without having a hepatic lesions were selected. ROI was set up in the liver and thigh area. after measuring $SUV_{max}$, the image quality was compared following the injected dose. Results: in phantom study, as the injected radioactivity concentration per unit mass was 1, 3, 5, 7, 9 MBq/kg, $SUV_{max}$ was 23.1, 24.1, 24.3, 22.8, 23.6 and SNR was shown 0.48, 0.54, 0.56, 0.55, 0.55. according to increment of the injected dose, $SUV_{max}$ and SNR was increased under 5 MBq/kg but they were decreased over 7 MBq/kg. in case of clinical experiment, as increased the injected radioactivity concentration per unit mass was 4.72, 5.34, 6.16, 7.41, 8.68 MBq/kg, $SUV_{max}$ was 2.68, 2.67, 2.26, 1.88, 1.95 and SNR was shown 0.52, 0.53, 0.46, 0.46, 0.44. if the injected dose exceeds 5 MBq/kg, showed a decrease pattern as phantom study. Conclusion: increasing $^{18}F$-FDG injected dose considered patient's body weight improve image quality within a certain range. if it exceeds the range, it can be reduced image quality due to random and scatter coincidences. this study indicates that the optimal injected dose was 5 MBq/kg per unit mass the injected radioactivity concentration in 3d wb pet/ct.

  • PDF

Clinical Application of $^{18}F-FDG$ PET in Head and Neck Cancer (두경부 종양에서 $^{18}F-FDG$ PET의 임상이용)

  • Kim, Jae-Seung;Bae, Jin-Ho
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.6-13
    • /
    • 2008
  • Head and neck cancer is the sixth most common type of human cancer worldwide. Squamous cell carcinoma is the most common cancer of the head and neck. Since $^{18}F-FDG$ PET is very sensitive to detecting squamous cell carcinoma, it has been widely used in patients with head and neck cancers for initial staging, management of recurrent cancers, and therapeutic monitoring. According to clinical research data, $^{18}F-FDG$ PET is expected to be a very helpful diagnostic tool in the management of head and neck cancer.

Combination of 18F-Fluorodeoxyglucose PET/CT Radiomics and Clinical Features for Predicting Epidermal Growth Factor Receptor Mutations in Lung Adenocarcinoma

  • Shen Li;Yadi Li;Min Zhao;Pengyuan Wang;Jun Xin
    • Korean Journal of Radiology
    • /
    • v.23 no.9
    • /
    • pp.921-930
    • /
    • 2022
  • Objective: To identify epidermal growth factor receptor (EGFR) mutations in lung adenocarcinoma based on 18F-fluorodeoxyglucose (FDG) PET/CT radiomics and clinical features and to distinguish EGFR exon 19 deletion (19 del) and exon 21 L858R missense (21 L858R) mutations using FDG PET/CT radiomics. Materials and Methods: We retrospectively analyzed 179 patients with lung adenocarcinoma. They were randomly assigned to training (n = 125) and testing (n = 54) cohorts in a 7:3 ratio. A total of 2632 radiomics features were extracted from the tumor region of interest from the PET (1316) and CT (1316) images. Six PET/CT radiomics features that remained after the feature selection step were used to calculate the radiomics model score (rad-score). Subsequently, a combined clinical and radiomics model was constructed based on sex, smoking history, tumor diameter, and rad-score. The performance of the combined model in identifying EGFR mutations was assessed using a receiver operating characteristic (ROC) curve. Furthermore, in a subsample of 99 patients, a PET/CT radiomics model for distinguishing 19 del and 21 L858R EGFR mutational subtypes was established, and its performance was evaluated. Results: The area under the ROC curve (AUROC) and accuracy of the combined clinical and PET/CT radiomics models were 0.882 and 81.6%, respectively, in the training cohort and 0.837 and 74.1%, respectively, in the testing cohort. The AUROC and accuracy of the radiomics model for distinguishing between 19 del and 21 L858R EGFR mutational subtypes were 0.708 and 66.7%, respectively, in the training cohort and 0.652 and 56.7%, respectively, in the testing cohort. Conclusion: The combined clinical and PET/CT radiomics model could identify the EGFR mutational status in lung adenocarcinoma with moderate accuracy. However, distinguishing between EGFR 19 del and 21 L858R mutational subtypes was more challenging using PET/CT radiomics.

The Evaluation for Attenuation Map using Low Dose in PET/CT System (PET/CT 시스템에서 감쇠지도를 만들기 위한 저선량 CT 평가)

  • Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Lee, Chang-Lae;Lim, Han-Sang;Park, Hoon-Hee;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.134-138
    • /
    • 2007
  • The current PET/CT system with high quality CT images not only increases diagnostic value by providing anatomic localization, but also shortens the acquisition time for attenuation correction than primary PET system. All commercially available PET/CT system uses the CT scan for attenuation correction instead of the transmission scan using radioactive source such as $^{137}Cs,\;^{68}Ge$. However the CT scan may substantially increase the patient dose. The purpose of this study was to evaluate quality of PET images reconstructed by CT attenuation map using various tube currents. in this study, images were acquired for 3D Hoffman brain phantom and cylindrical phantom using GE DSTe PET/CT system. The emission data were acquired for 10 min using phantoms after injecting 44.03 MBq of $^{18}F-FDG$. The CT images for attenuation map were acquired by changing tube current from 10 mA to 95 mA with fixed exposure time of 8 sec and fixed tube voltage of 140 kVp. The PET images were reconstructed using these CT attenuation maps. Image quality of CT images was evaluated by measuring SD (standard deviation) of cylindrical phantom which was filled with water and $^{18}F-FDG$ solution. The PET images were evaluated by measuring the activity ratio between gray matter and white matter in Hoffman phantom images. SDs of CT images decrease by increasing tube current. When PET images were reconstructed using CT attenuation maps with various tube currents, the activity ratios between gray matter and white matter of PET images were almost same. These results indicated that the quality of the PET images using low dose CT data were comparable to the PET images using general dose CT data. Therefore, the use of low dose CT is recommended than the use of general dose CT, when the diagnostic high quality CT is not required. Further studies may need to be performed for other system, since this study is limited to the GE DSTe system used in this study.

  • PDF

Diagnostic Usefulness of FDG-PET in Cervical Metastasis of Squamous Cell Carcinoma of the Head and Neck (두경부 편평세포암종의 경부 전이에 대한 F-18 FDG PET의 진단적 유용성)

  • Kim Chan-Jong;Kim Jae-Seung;Kang Woo-Seuk;Nam Soon-Yuhl;Choi Seung-Ho;Kim Sang-Yoon
    • Korean Journal of Head & Neck Oncology
    • /
    • v.19 no.2
    • /
    • pp.142-147
    • /
    • 2003
  • Purpose: Accurate evaluation of metastatic cervical lymph nodes plays a decisive role in the treatment and prognosis of patients with squamous cell carcinoma of the head and neck. The purpose of this study is to investigate the usefulness of FDG-PET for diagnosis of cervical metastasis in the head and neck cancer by comparing with the conventional imaging study. Materials and Methods: The subjects on this study were 30 patients (24 males and 6 females, aged 39 to 76, mean 57.1) diagnosed as pathologic-proven squamous cell carcinomas of the head and neck. All patients underwent preoperative FDG-PET, CT(n=27) or MRI (n=3). Their medical records were reviewed retrospectively. Using pathologic reports as a golden standard, the results of FDG-PET were compared with conventional imaging study (CT/MRI) in the evaluation of cervical metastasis. Results: Thirty patients had five different primary sites which were tongue (11), supraglottis (10), glottis (6), hypopharynx (2) and tonsil (1). A total of 40 neck dissections were performed unilaterally in 20 patients and bilaterally in 10 patients. Of these, 16 showed pathologically positive for lymph node metastasis. The sensitivity and specificity of FDG-PET for the diagnosis of cervical metastasis was 75% and 100% respectively, compared with conventional imaging of 56.3% and 95.8%, respectively. The difference of sensitivity was not statistically significant (p=0.453). Of 5 cases with small metastatic node (<1cm), 3 were detected on PET detected correctly but none were detected by CT. Conclusion: FDG-PET was more accurate than conventional imaging study in the diagnosis of metastatic lymph nodes in squamous cell carcinomas of the head and neck, especially detection of small metastatic node. FDG-PET might be useful adjunct to conventional image in the preoperative evaluation of head and neck squamous cell carcinoma.

A Study on the Reduction of Kidney Uptake of 18F-FDG due to the Water Intake at the Time of Additional Examination in the PET/CT scan (PET/CT 검사에서 추가 검사 시 수분섭취에 따른 18F-FDG의 신장 섭취 감소에 대한 고찰)

  • Lee, Yi Lang;Kim, Sang Gyu;Ham, Jun Chul;Nam-Koong, Hyuk;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.47-51
    • /
    • 2016
  • Purpose By ingestion of 18F-FDG of kidney of PET/CT during the inspection, if additional examination is required, depending on whether you want to water intake, we want to confirm a change in the rate of decrease of F-18 FDG of the kidney. Materials and Methods The 80 patients without kidney disease were performed PET/CT examination. Device was analyzed after setting the kidney to a three-dimensional region of interest. In patients require additional examination, and inspection after 30 minutes, a PET/CT torso examination after the water of the 500 cc ingested at a time. After the addition of both water intake group and no hydration group of kidney of SUV, it was compared with PET/CT torso scan. Results High and low of the kidney SUV did not show a significant difference in the rate of decrease. Reduction rates of background (BKG) of additional examination was 2.8% and reduction rates of SUV was 49.7% (Hydration) : -6.8% (No hydration), so did show a significant difference. In the image blind test, the average point score of hydration and no hydration was 34.25 : 17.25. Conclusion An undercurrent of 18F-FDG in the kidney at the time of torso examination, it was confirmed that the reduction rate after the addition of water intake is high. It is considered that can be expected to improve the quality of an image due to a decrease in elongation through the kidneys examination with additional fluid intake as needed intake.

  • PDF

The Role of $^{18}F-fluorodeoxyglucose$ Positron Emission Tomography in Gastrointestinal Stromal Tumors (위장관 간질 종양(Gastrointestinal stromal tumor)에서 $^{18}F-fluorodeoxyglucose$ positron emission tomography의 역할)

  • Yoo, Ie-Ryung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.46-51
    • /
    • 2008
  • Gastrointestinal stromal tumors (GIST) are the most common mesenchymal neoplasm of the gastrointestinal tract, and can be distinguished from the smooth muscle or neural tumors in approximately 95% of patients by expression of the KIT receptor tyrosine kinase (CD117). GISTs are known to have high malignant potential and none can be labeled definitely as benign. However, GISTs are unresponsive to standard sarcoma chemotherapy, and only complete surgical resection provides chance for cure. Although the imaging modality of choice is enhanced CT scan in patients with GIST, FDG PET can reflect the malignant potential of GIST. Clinical management of patients with GISTs has dramatically changed with the introduction of novel therapeutics, such as imatinib mesylate (Glivec). This has created a need to re-evaluate the existing criteria used to assess treatment response. FDG PET as functional imaging modality proved to be significantly more accurate than CT alone when assessing GIST response to imatinib. And, FDG PET and PET ICT have been found to be highly sensitive in detecting early response, and to be useful in predicting long-term response to imatinib in patients with recurrent or metastatic GISTs.

Usefulness of $^{18}F$-FDG Fusion PET for Diagnosing an Early Stage Cancer (조기 암 진단을 위한 $^{18}F$-FDG Fusion PET의 유용성)

  • Jeon, Jae-Hwan;Kim, Byeong-Jin;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.145-149
    • /
    • 2010
  • Purpose: Recently, $^{18}F$-FDG Fusion PET which has a high sensitivity for diagnosing cancer is being used for purpose of health examination. This study is to demonstrate that $^{18}F$-FDG fusion PET study is useful for diagnosing an early stage cancer. Materials and Methods: This research has been conducted with 2790 patients visited Seoul National University Hospital Healthcare System (SNUHHS) for $^{18}F$-FDG fusion PET study for a health examination from February, 2004 to December 2008. PET/CT images were acquired from skull base to femur after 1 hour from injecting $^{18}F$-FDG 0.14 mCi/kg to the patients. GEMINI GS (Philips, Netherlands) was used for scanning. Results: From February 2004 to December 2008, $^{18}F$-FDG Fusion PET study was performed for 99,009 patients among all patients who visited SNUHHS and 2,790 patients was performed. Diagnostic rate for malignant cancer was 0.95% for the patients who were not examined by $^{18}F$-FDG Fusion PET study. 1.94% was for the patients who were. The rate of malignant tumor was showed 10% and benign tumor was 90% among 542 patients who showed abnormality in the PET/CT images. Types and rates of malignant tumor showed thyroid cancer: 31.5%, lung cancer: 14.8%, stomach cancer: 9.3%, rectum cancer: 3.7%, breast cancer: 3.7%, metastasis cancer: 16.7%. Nonspecific lymph node in the mediastinum, physiologic uptake in the colon, diffuse mild hypermetabolism in bilateral thyroid gland were shown as a benign tumor. Conclusion: The diagnostic rate of malignant tumor with $^{18}F$-FDG Fusion PET for a purpose of health examination was relatively higher than general medical examination. Consequently, it is superior and useful for applying $^{18}F$-FDG Fusion PET study for health examination.

  • PDF

Effectiveness of Positron Emission Tomography in the Pre-operative Staging of Gastric Cancer (위암환자의 술 전 병기 결정에서 PET-CT의 유용성)

  • Park, Shin-Young;Bae, Jung-Min;Kim, Se-Won;Kim, Sang-Woon;Song, Sun-Kyo
    • Journal of Gastric Cancer
    • /
    • v.9 no.3
    • /
    • pp.110-116
    • /
    • 2009
  • Purpose: The aim of this study was to examine the usefulness of positron emission tomography (PET)-computed tomography (CT) in the pre-operative staging of gastric cancer. Materials and Methods: Between February 2006 and August 2008, PET-CT and CT were performed on 70 patients diagnosed with gastric cancer by gastrofiberscopic biopsy. The sensitivities, specificities, Positive predictive value (PPV), and negative predictive value (NPV) of PET-CT and CT imaging for the detection of gastric cancer TNM staging were compared. Results: The detection rates for the primary tumor were as follows: PET-CT, 81.4% (57/70); and CT, 42.9% (30/70). For both early gastric cancer (EGC) and advanced gastric cancer (AGC), PET-CT was more accurate than CT in detecting the lesions. As the size of the tumor exceeded 3 cm, the detection rate increased. The sensitivities, specificities, PPV, and NPV of PET-CT for lymph node staging were 55.6%, 81%, 86.2%, and 45.9%, while the sensitivities, specificities, PPV, and NPV of CT were 40.0%, 85.7%, 85.7% and 40%, respectively. One case of multiple liver metastasis and two cases of dual primary cancer (rectal and pancreatic cancers) were detected by PET-CT. PET-CT also had a higher detection rate for all histologic types of primary tumors. PET-CT was more accurate than CT in detecting primary gastric cancer lesions. The detection of nodal metastasis by PET-CT was similar to CT; small-sized tumors or EGC detection rates were not high. However, PET-CT provided additional information to detect distant metastases and dual primary cancers and reduced unnecessary laparotomies to detect peritoneal seeding or carcinomatosis. Conclusion: It would be useful to make a pre-operative diagnosis of gastric cancer and determine treatment if PET-CT were added to other routine pre-operative studies.

  • PDF