국내 수용가계통에서의 초전도한류기 적용가능성 검토 (A study on the application of HTS-FCL in Korean Customer Power System)

  • 이승렬;김종율;윤재영
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권3호
    • /
    • pp.44-49
    • /
    • 2004
  • As the load density of KEOCO system is higher, the fault current can be much higher than SCC(Short Circuit Capacity) of circuit breaker. Fault current exceeding the rating of circuit breaker is a very serious problem in high density load area, which can threaten the stability of whole power system. Even though there are several alternatives to reduce fault current, as the superconductivity technology has been developed, the HTS-FCL(High Temperature Superconductivity Fault Current Limiter) can be one of the attractive alternatives to solve the fault current problem. This study presents the application of 154kV HTS-FCL in Korean power system.

삼상형 dc reactor형태 한류기의 단락회로실험을 위한 시뮬레이션 (Simulation of the Three-phase DC Reactor Type Fault Current Limiter for the Short-circuit Test)

  • 이응로;이승제;이찬주;고태국;현옥배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.717-719
    • /
    • 2001
  • This paper deals with simulation of the three-phase dc reactor type fault current limiter(FCL). This is a preliminary step to develop the FCL's faculties for an application to high voltage transmission line. A three-phase dc reactor type FCL consists of transformers, diodes, and a superconducting coil. By this simulation for the short-circuit test we can investigate the safety of FCL's elements. And, result of simulation will contribute parameter toward optimal design.

  • PDF

퀸칭 특성을 고려한 EMTDC 저항형 초전도 한류기 모텔링 (Modeling of the HTS Fault Current Limiter Considering Quenching Characteristic)

  • 윤재영;김종율;이승렬
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권2호
    • /
    • pp.73-79
    • /
    • 2004
  • Nowadays, one of the serious problems in KEPCO system is the larger fault current than the SCC(Short Circuit Capacity) of circuit breaker. There are many alternatives to reduce the increased fault current such as isolations of bus ties, enhancement of SCC of circuit breaker, applications of HVDC-BTB(Back to Back) and FCL(fault current limiter). However, these alternatives have some drawbacks in viewpoints of system stability and cost. As the superconductivity technology has been developed, the HTS-FCL(High Temperature Superconductor-Fault Current Limiter) can be one of the attractive alternatives to solve the fault current problem. Under this background, this paper presents the EMTDC model for resistive type HTS-FCL considering the nonlinear characteristic of final resistance value when quenching Phenomena occur.

Monte Carlo Simulation을 이용한 초전도 한류기 EMTDC 모델의 파라메터 최적 설계 (Optimal Design of HTS Fault Current Limiter using Monte Carlo Simulation Method)

  • 윤재영;김종율;이승렬
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권3호
    • /
    • pp.135-139
    • /
    • 2004
  • Nowadays, one of the serious problems in KEPCO system is large fault current which exceeds the SCC(Short Circuit Capacity) of circuit breaker, As the superconductivity technology has been developed, the HTS-FCL(High Temperature Superconductor-Fault Current Limiter) can be one of the attractive alternatives to solve the fault current problem. However, the parameters of HTS-FCL should be designed optimally to have a best performance. Under this background, this paper presents the optimal design method of parameters for resistive type HTS-FCL using stochastic analysis technique.

초전도한류기의 최적 적용위치 선정 프로그램 개발 (Development of HTS-FCL Location Selection Program in Power System)

  • 최흥관;윤재영;김종율;이승렬;이병준
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.205-208
    • /
    • 2003
  • Maximum short circuit current of modern power system is becoming so large that the current should transmission capability. Although there are various kinds of method to solve this, approached from super conductivity Fault Current Limiter application viewpoint among them. High Temperature Superconductor-Fault Current Limiter (HTS-FCL) development is progressing according to HTS technology development, and system application is tried. For actual system application of such super conductivity FCL, an efficient method to find FCL locations suitable for reduction of short circuit currents of more than one fault location is developed.

  • PDF

?칭 특성을 고려한 EMTDC 저항형 초전도 한류기 모텔링 (Modeling of the HTS Fault Current Limiter Considering Quenching Characteristic)

  • 윤재영;김종율;이승렬
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권2호
    • /
    • pp.73-73
    • /
    • 2004
  • Nowadays, one of the serious problems in KEPCO system is the larger fault current than the SCC(Short Circuit Capacity) of circuit breaker. There are many alternatives to reduce the increased fault current such as isolations of bus ties, enhancement of SCC of circuit breaker, applications of HVDC-BTB(Back to Back) and FCL(fault current limiter). However, these alternatives have some drawbacks in viewpoints of system stability and cost. As the superconductivity technology has been developed, the HTS-FCL(High Temperature Superconductor-Fault Current Limiter) can be one of the attractive alternatives to solve the fault current problem. Under this background, this paper presents the EMTDC model for resistive type HTS-FCL considering the nonlinear characteristic of final resistance value when quenching Phenomena occur.

초전도한류기의 계통적용점 선정 프로그램 개발 (Development of HTS-FCL Location Selection Program in Power System)

  • 최흥관;윤재영;김종율;이승렬;이병준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.321-323
    • /
    • 2003
  • Maximum short circuit current of modern power system is becoming so large that the current should transmission capability. Although there are various kinds of method to solve this, approached from super conductivity Fault Current Limiter application viewpoint among them. High Temperature Superconductor-Fault Current Limiter(HTS-FCL) development is progressing according to HTS technology development, and system application is tried. For actual system application of such super conductivity FCL, an efficient method to find FCL locations suitable for reduction of short circuit currents of more than one fault location is developed.

  • PDF

감도계수를 고려한 초전도한류기의 계통적용점 선정 연구 (Development of HTS-FCL Location Selection Program using Sensitivity Factor)

  • 최흥관;윤재영;김종율;이승렬;이병준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.240-242
    • /
    • 2004
  • Maximum short circuit current of modern power system is becoming so large that the current should transmission capability. Although there are various kinds of method to solve this, approached from super conductivity Fault Current Limiter application viewpoint among them. High Temperature Superconductor-Fault Current Limiter (HTS-FCL) development is progressing according to HTS technology development, and system application is tried. For actual system application of such super conductivity FCL, an more efficient method was developed to find suitable FCL application locations using sensitivity factor comparing previous paper.

  • PDF

급성 위염 동물 모델에서 감국(甘菊) 추출물과 아마인유(亞麻仁油) 혼합물의 위 점막 보호 효과 (Protective Effects of Chrysanthemi Indici Flos Extract and Flaxseed Oil Mixture on HCl/ethanol-induced Acute Gastric Lesion Mice)

  • 이진아;김수현;김민주;안정현;박해진;이우락;노성수
    • 대한본초학회지
    • /
    • 제33권6호
    • /
    • pp.19-28
    • /
    • 2018
  • Objectives : The objective of this study was to investigate the protective effect of Flaxseed oil and Chrysanthemi Indici Flos 50% ethanol extract in an HCl/ethanol induced acute gastritis model. Methods : ICR mice were divided into 6 groups; normal mice (Nor), gastritic mice with distilled water (Veh), gastritic mice with 10 mg/kg sucralfate (SC), gastritic mice with 16 g/㎏ Flaxseed oil (FO), gastritic mice with FO + 50 mg/kg Chrysanthemi Indici Flos (FCL), and gastritic mice with FO + 100 mg/kg Chrysanthemi Indici Flos (FCH). Then, mice were orally administered with 150 mM HCl/60% ethanol and caused acute gastritis. After 1 hr, mice were sacrificed, and blood and stomach tissue were collected. Results : Administration of FCL and FCH to mice prior to the induction of gastritis was found to reduce gastric injury. reactive oxygen species (ROS) and peroxy nitrite ($ONOO^-$) levels of stomach tissues were significantly decreased in FO, FCL, and FCH compared to Veh group. As results of stomach protein analyses, FCL and FCH effectively reduce inflammatory-related factors such as inducible nitric oxide synthase (iNOS), interleukin-6 (IL-6), and interleukin 1 beta ($IL-1{\beta}$) in gastric lesion mice. In addition, nuclear factor kappa B p65 ($NF-{\kappa}B$ p65) and phosphorylation inhibitor of nuclear factor kappa $B{\alpha}(p-I{\kappa}B{\alpha})$ were down-regulated in FCL and FCH administrated gastric lesion mice. Conclusions : These results suggest that FCL and FCH has an inhibitory effect against gastric injury. Therefore, FCL and FCH has the potential to be used as a natural therapeutic drug.