• Title/Summary/Keyword: FAN

Search Result 3,629, Processing Time 0.037 seconds

Survey of ICT Apply to Plastic Greenhouse, Rack·Pinion Adaption to Single Span and CFD Analysis (온실 ICT융복합 실태조사와 복숭아형 랙피니언천창 적용 단동온실 및 CFD 유동해석)

  • Cho, Kyu Jeong;Kim, Ki Young;Yang, Won Mo
    • Journal of Bio-Environment Control
    • /
    • v.24 no.4
    • /
    • pp.308-316
    • /
    • 2015
  • This study was conducted to investigate the situation of ICT apply to plastic greenhouse, and the results be apply to design of new one. A CFD analysis were conducted to monitering the ventilation and energy saving of the single span greenhouse newly designed. The causes of delay to apply ICT to plastic greenhouse are the high cost for installation(24%), insufficiency of after services(19%), often disorder(16%), unskillful management of soft ware(15%), insufficient ICT efficiency(13%) and unsatisfying of income increase(12%). The parts of problem occurred in ICT plastic greenhouse are the structure, actuator, environmental control system and sensor(approximate 14%, respectively), remote control technique(13%), plant management technique(12%), energy saving technique(10%) and utilization of software(8%). In the condition of lateral window closed, the average wind speed changed to slow, but it was faster in the condition of leeward side window opened than in the condition of lee and winward side window opened. The air movement in the condition of lateral window closed occur by air moving fan not by out air. It is not affect the room temperature but effective the uniformity of room temperature. The average temperature of low height greenhouse was uniform than high height one. The average temperature in condition of 3rd curtain opened become same with outside temperature after 2 hours, but take more 5 hours in condition of 3rd curtain closed.

Analysis of Temperature and Humidity Distributions according to Arrangements of Air Circulation Fans in Single-span Tomato Greenhouse (토마토 단동온실에서 공기순환팬 설치 방법에 의한 온실 내 온습도 분포 분석)

  • Lee, Tae Seok;Kang, Geum Choon;Paek, Yee;Moon, Jong Pil;Oh, Sung Sik;Kwon, Jin Kyung
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.277-282
    • /
    • 2016
  • This study was aimed to investigate the effect of air-circulation fans on air temperature and relative humidity in a single-span tomato greenhouse (W: 7m, L: 25m, H: 3.2m). According to standard of fan layout by ASAE (1997), a total of 10 fans were bilaterally arranged in 2 rows in the experimental greenhouse. The distributions of air temperature and relative humidity were measured from 6 pm to 8 am under different conditions, with and without fans. The measurement heights were 0.7m, 1.7m and 2.7m. Under the condition of "fans off", the spatial differences of air temperature and relative humidity between upper and lower sides were $1.7^{\circ}C$ and 10.8%, respectively. The operation of 10 fans showed their differences to $0.1^{\circ}C$ and 3.2%. The number of fans and installation direction were evaluated their performance on reducing the spatial variation of air temperature and relative humidity. The experimental layouts were 5 and fans in 2 rows (bilaterally) and 10 fans in the one (same) direction. Under the condition of "6 fans on" and "5 fans on", the spatial differences of air temperature and relative humidity between upper and lower side were $0.3^{\circ}C$, 3.4% and $0.3^{\circ}C$ and 4.0%. The operation of 10 fans in the one direction reduced their differences to $0.5^{\circ}C$ and 4.9%. The overall findings of this study showed that there was no significant differences under each condition. Therefore, this study suggested that it is more economic and effective to install five fans in 2 rows (bilaterally) in the greenhouse (W: 7m, L: 25m, H: 3.2m).

Heating Performance Analysis of the Heat Pump System for Agricultural Facilities using the Waste Heat of the Thermal Power Plant as Heat Source (발전소 폐열을 이용한 농업시설용 히트펌프시스템의 난방 성능 분석)

  • Kang, Youn Koo;Kang, Suk Won;Paek, Yee;Kim, Young Hwa;Jang, Jae Kyung;Ryou, Young Sun
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.317-323
    • /
    • 2017
  • In this study, the heating performance and the energy saving effect of the heat pump system using hot waste water(waste heat) of the thermal power plant discharged from a thermal power plant to the sea were analyzed. The greenhouse area was $5,280m^2$ and scale of the heat pump system was 120 RT(Refrigeration Ton), which was divided into 30 RT, 40 RT and 50 RT. The heat pump system consisted of the roll type heat exchangers, hot waste water transfer pipes, heat pumps(30, 40, 50 RT), a heat storage tank and fan coil units. The roll type heat exchangers was made of PE(Poly Ethylene) pipes in consideration of low cost and durability against corrosion, because hot waste water(sea water) is highly corrosive. And the heating period was 5 months from October to February. During the heating performance test(12 hours), the inlet water temperature of evaporator was changed from $32^{\circ}C$ to $26^{\circ}C$, and heat absorption of he evaporator was changed from 175 kW to 120 kW. The inlet water temperature of the condenser rose linearly from $15^{\circ}C$ to $50^{\circ}C$, and the heat release of condenser was reduced by 40 kW from 200 kW to 160 kW. And the power consumption of the heat pump system increased from 30 kW to 42 kW. When the inlet water temperature of condenser was $15^{\circ}C$, the heating COP(Coefficient Of Performance) was over 7.0. When it was $30^{\circ}C$, it dropped to 5.0, and when it was above $40^{\circ}C$, it decreased to less than 4.0. It was analyzed that the reduction of heating energy cost was 87% when compared to the duty free diesel that the carbon dioxide emission reduction effect was 62% by recycling the waste heat of the thermal power plant as a heat source of the heat pump system.

Analysis of Air Temperature and Humidity Distributions and Energy Consumptions according to Use of Air Circulation Fans in a Single-span Greenhouse (단동온실 내 공기순환팬 사용에 따른 온습도 및 에너지소비량 비교 분석)

  • Lee, Tae Seok;Kang, Geum Choon;Kim, Hyung Kweon;Moon, Jong Pil;Oh, Sung Sik;Kwon, Jin Kyung
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.276-282
    • /
    • 2017
  • The aim of this study was to compare and analyze air temperature and humidity distribution and energy consumptions according to using air circulation fans in single-span greenhouses. The greenhouses located in Cheongnam-myeon, Cheongyang-gun, Chungcheongnam-do, Korea. There were cherry tomatoes in the greenhouses and the size of greenhouses was as follows;ridge height : 3.2 m, wide : 6 m, length : 95 m. The heating system was composed of a hot-water boiler and 6 FCUs(Fan Coil Unit)-4 FCUs were on bottom with duct and 2 FCUs were installed at 2.0 m. A total of 18 air circulation fans(impeller's diameter : 230 mm) were bilaterally arranged in 2 rows in the experimental greenhouse. The sensors for measuring air temperature and humidity were located at a quarter and three quarters of a length. The height of sensors were 0.8 m, 1.8 m. To calculate energy consumption in greenhouses, water temperature at inlet and outlet in a water pump, volume of water were measured. Form February 3rd to March 23th, temperature, humidity and energy consumptions were measured during heating time(6pm~7am). In a greenhouse without fans, the average differences of temperature and humidity were $0.75^{\circ}C$, 2.31%, respectively. The operation of fans showed their differences to $0.42^{\circ}C$, 1.8%. The standard deviation of temperature and humidity between measuring points in the greenhouse with fans was lower than the greenhouse without fans. Total energy consumptions in a greenhouse without fans were 4,673 kWh. In the greenhouse with fans, the total energy consumptions were 4,009 kWh. The energy consumptions in a greenhouse with fans 14.2% were less than the greenhouse without fans. Therefore, air circulation makes temperature and humidity uniform and saves energy consumptions for heating.

A study on the effect of air velocity through a damper on smoke extraction performance in case of fire in road tunnels (도로터널 화재 시 집중배기방식의 배기포트 통과풍속이 배연성능에 미치는 영향에 관한 연구)

  • Ryu, Ji-Oh;Na, Kwang-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.4
    • /
    • pp.347-365
    • /
    • 2020
  • In order to resolve traffic problems in urban areas and to increase the area of green spaces, tunnels in downtown areas are being increased. Additionally, the application of large port smoke extraction ventilation systems is increasing as a countermeasure to smoke extraction ventilation for tunnels with high potential for traffic congestion. It is known that the smoke extraction performance of the large port smoke extraction system is influenced not only by the amount of the extraction flow rate, but also by various factors such as the shape of the extraction port (damper) and the extraction air velocity through a damper. Therefore, in this study, the design standards and installation status of each country were investigated. When the extraction air flow rate was the same, the smoke extraction performance according to the size of the damper was numerically simulated in terms of smoke propagation distance, compared and evaluated, and the following results were obtained. As the cross-sectional area of the smoke damper increases, the extraction flow rate is concentrated in the damper close to the extraction fan, and the smoke extraction rate of the damper in downstream decreases, thereby increasing the smoke propagation distance on the downstream side. In order to prevent such a phenomenon, it is necessary to reduce the cross-sectional area of the smoke damper and increase the velocity of passing air through the damper so that the pressure loss passing through the damper increases, thereby reducing the non-uniformity of smoke extraction flow rate in the extraction section. In this analysis, it was found that when the interval distance of the extraction damper was 50 m, the air velocity passing through damper was 4.4 m/s or more, and when the interval distance of the extraction dampers was 100 m, the air velocity passing through damper was greater than 4.84 m/s, it was found to be advantageous to ensure smoke extraction performance.

Association of Six Susceptibility Loci with Prostate Cancer in Northern Chinese Men

  • Zhang, Yu-Rong;Xu, Yong;Yang, Kuo;Liu, Ming;Wei, Dong;Zhang, Yao-Guang;Shi, Xiao-Hong;Wang, Jian-Ye;Yang, Fan;Wang, Xin;Liang, Si-Ying;Zhao, Cheng-Xiao;Wang, Fei;Chen, Xin;Sun, Liang;Zhu, Xiao-Quan;Zhu, Ling;Yang, Yi-Ge;Tang, Lei;Jiao, Hai-Yan;Huo, Zheng-Hao;Yang, Ze
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.12
    • /
    • pp.6273-6276
    • /
    • 2012
  • Background/Aim: Six prostate cancer (PCa) susceptibility loci were identified in a genome-wide association study (GWAS) in populations of European decent. However, the associations of these 6 single-nucleotide polymorphisms (SNPs) with PCa has remained tobe clarified in men in Northern China. This study aimed to explore the loci associated with PCa risk in a Northern Chinese population. Methods: Blood samples and clinical information of 289 PCa patients and 288 controls from Beijing and Tianjin were collected. All risk SNPs were genotyped using polymerase chain reaction (PCR)-high resolution melting curve technology and gene sequencing. Associations between PCa and clinical covariates (age at diagnosis, prostate-specific antigen [PSA], Gleason score, tumor stage, and level of aggressiveness) and frequencies of alleles and genotypes of these SNPs were analyzed using genetic statistics. Results: Among the candidate SNPs, 11p15 (rs7127900, A) was associated with PCa risk (P = 0.02, odds ratio [OR] = 1.64, 95% confidence interval [CI] = 1.09-2.46). Genotypes showed differences between cases and controls on 11p15 (rs7127900, A), 11q13 (rs7931342, T), and HNF1B (rs4430796, A) (P = 0.03, P = 0.01, and P = 0.04, respectively). The genotype TG on 11q13 (rs7931342, T) was positively associated with an increased Gleason score (P = 0.04, OR = 2.15, 95% CI = 1.02-4.55). Patients carrying TG on 17q24 (rs1859962, G) were negatively associated with an increased body mass index (BMI) (P = 0.03, OR = 0.44, 95% CI = 0.21-0.92) while those with AG on HNF1B (rs4430796, A) were more likely to have PSA increase (P = 0.002). Conclusion: Our study suggests that 11p15 (rs7127900, A) could be a susceptibility locus associated with PCa in Northern Chinese. Genotype TG on 11q13 (rs7931342, T) could be related to an increased Gleason score, AG on HNF1B (rs4430796, A) could be associated with PSA increase, and TG on 17q24 (rs1859962, G) could be negatively associated with an increased BMI in Chinese men with PCa.

Studies on Deacidification of Citrus Fruit and Juice for Juice Products by Heating Treatment and Electrodialysis (열처리 및 전기투석에 의한 초기수확 밀감의 탈산에 관한 연구)

  • Ko Won-Joon;Yang Min-Ho;Kang Yeung-Joo
    • Food Science and Preservation
    • /
    • v.13 no.2
    • /
    • pp.144-153
    • /
    • 2006
  • The effects on deacidification of citrus fruits produced at early harvesting season for juice products were examined by heating treatment of raw fruits and electrodialysis of juice. Weight and total acidities were decreased by heating treatment for 40 hr at $25^{\circ}C,\;30^{\circ}C,\;35^{\circ}C\;and\;40^{\circ}C$, but $^{\circ}Brix$ and pH increased Sugar to acid ratio also increased. Total acidities were decreased from 1.25 (Oct30, 2004), 1.24 (Nov.5, 2004), 0.99 (Nov.13, 2004) and 0.98% (Nov.19, 2004) to 0.48 (Oct30, 2004), 0.51 (Nov.05, 2004), 0.37 (Nov.13, 2004) and 0.42% (Nov.19, 2004) by electrodialysis for 100 min respectively, and $^{\circ}Brix$ also slightly decreased, but solid to acid ratio was increased as a result. However pH and color remained almost unchanged by electodialysis. Also, free sugar contents of citrus juice little were changed, but organic acid content were decreased fairly. Narirutin and hesperidin content among flavonoids were slightly decreased by electrodialysis, but they were not significantly different. $K^+,\;PO_4^{2-},\;SO_4^{2-}\;and\;Cl^-$ content were decreased by electrodialysis, and $K^+$ contents decreased by more than 80% However, $Na^+$ consent was increased by about 2 times. Total polyphenol contents and electron donating abilities were decreased a little by electrodialysis but nitrite scavenging abilities were little changed. By acceptability test citrus juice prepared by electrodialysis for 100 min was superior to original citrus juice.

20-Year Experience of Surgical Treatment for Postpneumonectomy Empyema (전폐절제술 후 사강에 발생한 농흉의 치료)

  • 김형렬;김영태;성숙환;김주현
    • Journal of Chest Surgery
    • /
    • v.35 no.7
    • /
    • pp.542-547
    • /
    • 2002
  • Background: Postpneumonectomy empyema(PPE) is an infrequent but potentially life-threatening complication. To date, various surgical efforts have been made to manage this complication. We reviewed our 20-year surgical experience of PPE and long-term follow-up data. Material and Method: Total of 37 patients who were treated for PPE between fan, 1980 and Jun, 2000 were included. Various clinical factors such as micro-organism, operative method and timing, presence of bronchopleural fistula(BPF), underlying disease and fate of empyema cavity were retrospectively reviewed and analyzed. Result: Majority of patients(34) underwent Eloesser operation for effective drainage. There was only one operative mortality. The causative organisms were Staphylococcus species and Pseudomonas species in 46% BPF was found in 20 cases, among which spontaneous closures took place in 4 cases. The chest wall was closed in 40%(8/20) of patients with BPF, compared to 59%(10/17) without BPF. The closure rate was statistically better in patients without BPF(p=0.006). Even though the patients with benign disease showed higher closure rate(50%) than those with lung cancer (31%), the difference was not significant(p=0.25). Conclusion: Eloesser procedure was an effective method for initial drainage of PPE cavity with low operative mortality. Given the findings of low spontaneous closure rate of BPF, aggressive approach to close the BPF is mandatory to achieve the final goal of chest wall closure. It was found that majority of patients still left their chest cavity opened, even after controlling the active inflammation of the empyema cavity. More aggnessive approach for chest wall closure is recommended in all patents with benign disease and in selective patients with lung cancer if there is no evidence of recurrence at several years after the initial operation.

Susceptibility Loci Associations with Prostate Cancer Risk in Northern Chinese Men

  • Wang, Na-Na;Xu, Yong;Yang, Kuo;Wei, Dong;Zhang, Yao-Guang;Liu, Ming;Shi, Xiao-Hong;Liang, Si-Ying;Sun, Liang;Zhu, Xiao-Quan;Yang, Yi-Ge;Tang, Lei;Zhao, Cheng-Xiao;Wang, Xin;Chen, Xin;Hui, Juan;Zhang, Yu-Hong;Zhu, Ling;Yang, Fan;Zhang, Yu-Rong;Yang, Ze;Wang, Jian-Ye
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.5
    • /
    • pp.3075-3078
    • /
    • 2013
  • Background: KLK3 gene products, like human prostate-specific antigen (PSA), are important biomarkers in the clinical diagnosis of prostate cancer (PCa). G protein-coupled receptor RFX6, C2orf43 and FOXP4 signaling plays important roles in the development of PCa. However, associations of these genes with PCa in northern Chinese men remain to be detailed. This study aimed to investigate their impact on occurrence and level of malignancy. Methods: All subjects were from Beijing and Tianjin, including 266 cases with prostate cancer and 288 normal individuals as controls. We evaluated associations between clinical covariates (age at diagnosis, prostate specific antigen, Gleason score, tumor stage and aggressive) and 6 candidate PCa risk loci, genotyped by PCR- high resolution melting curve and sequencing methods. Results: Case-control analysis of allelic frequency of PCa associated with PCa showed that one of the 6 candidate risk loci, rs339331 in the RFX6 gene, was associated with reduced risk of prostate cancer (odds ratio (OR) = 0.73, 95% confidence interval (CI) =0.57-0.94, P = 0.013) in northern Chinese men. In addition, subjects with CX (CC+TC) genotypes had a decreased risk for prostrate cancer compared to those carrying the TT homozygote (OR =0.64, 95% CI = 0.45- 0.90, P = 0.008). The TT genotype of 13q22 (rs9600079, T) was associated with tumor stage (P=0.044, OR=2.34, 95% CI=0.94-5.87). Other SNPs were not significantly associated with clinical covariates in prostate cancer (P > 0.05). Conclusions. rs339331 in the RFX6 gene may be associated with prostate cancer as a susceptibility locus in northern Chinese men.

Effects of a traditional Chinese medicine formula and its extraction on muscle fiber characteristics in finishing pigs, porcine cell proliferation and isoforms of myosin heavy chain gene expression in myocytes

  • Yu, Qin Ping;Feng, Ding Yuan;He, Xiao Jun;Wu, Fan;Xia, Min Hao;Dong, Tao;Liu, Yi Hua;Tan, Hui Ze;Zou, Shi Geng;Zheng, Tao;Ou, Xian Hua;Zuo, Jian Jun
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.11
    • /
    • pp.1620-1632
    • /
    • 2017
  • Objective: This study evaluated the effects of a traditional Chinese medicine formula (TCMF) on muscle fiber characteristics in finishing pigs and the effects of the formula's extract (distilled water, ethyl acetate and petroleum ether extraction) on porcine cell proliferation and isoforms of myosin heavy chain (MyHC) gene expression in myocytes. Methods: In a completely randomized design, ninety pigs were assigned to three diets with five replications per treatment and six pigs per pen. The diets included the basal diet (control group), TCMF1 (basal diet+2.5 g/kg TCMF) and TCMF2 (basal diet+5 g/kg TCMF). The psoas major muscle was obtained from pigs at the end of the experiment. Muscle fiber characteristics in the psoas major muscle were analyzed using myosin ATPase staining. Cell proliferation was measured using 3-(4,5-dimethyl-2-thiazolyl)-2,5-diphenyl-2H-tetrazolium bromide (MTT) dye and cytometry. Isoforms of MyHC gene expression were detected by real-time quantitative polymerase chain reaction. Results: The final body weight and carcass weight of finishing pigs were increased by TCMF1 (p<0.05), while the psoas major muscle cross-sectional area was increased by TCMF (p<0.05). The cross-sectional area and diameter of psoas major muscle fiber Ι, IIA, and IIB were increased by TCMF2 (p<0.05). The cross-sectional area and fiber diameter of psoas major muscle fiber IIA and IIB were increased by diet supplementation with TCMF1 (p<0.05). Psoas major muscle fiber IIA and IIB fiber density from the pigs fed the TCMF1 diet and the type IIB fiber density from the pigs fed the TCMF2 diet were lower compared to pigs fed the control diet (p<0.05). Pigs fed TCMF2 had a higher composition of type Ι fiber and a lower percentage of type IIB fiber in the psoas major muscle (p<0.05). The expression levels of MyHC Ι, MyHC IIa, and MyHC IIx mRNA increased and the amount of MyHC IIb mRNA decreased in the psoas major muscle from TCMF2, whereas MyHC Ι and MyHC IIx mRNA increased in the psoas major muscle from TCMF1 (p<0.05). Peroxisome proliferator-activated receptor ${\gamma}$ $coactivator-1{\alpha}$ and CaN mRNA expression in the psoas major muscle were up-regulated by TCMF (p<0.05). Porcine skeletal muscle satellite cell proliferation was promoted by $4{\mu}g/mL$ and $20{\mu}g/mL$ TCMF water extraction (p<0.05). Both $1{\mu}g/mL$ and $5{\mu}g/mL$ of TCMF water extraction increased MyHC IIa, MyHC IIb, and MyHC IIx mRNA expression in porcine myocytes (p<0.05), while MyHC Ι mRNA expression in porcine myocytes was decreased by $5{\mu}g/mL$ TCMF water extraction (p<0.05). Porcine myocyte MyHC Ι and MyHC IIx mRNA expression were increased, and MyHC IIa and MyHC IIb mRNA expression were down-regulated by $5{\mu}g/mL$ TCMF ethyl acetate extraction (p<0.05). MyHC Ι and MyHC IIa mRNA expression in porcine myocytes were increased, and the MyHC IIb mRNA expression was decreased by $1{\mu}g/mL$ TCMF ethyl acetate extraction (p<0.05). Four isoforms of MyHC mRNA expression in porcine myocytes were reduced by $5{\mu}g/mL$ TCMF petroleum ether extraction (p<0.05). MyHC IIa mRNA expression in porcine myocytes increased and MyHC IIb mRNA expression decreased by $1{\mu}g/mL$ in a TCMF petroleum ether extraction (p<0.05). Conclusion: These results indicated that TCMF amplified the psoas major muscle cross-sectional area through changing muscle fiber characteristics in finishing pigs. This effect was confirmed as TCMF extraction promoted porcine cell proliferation and affected isoforms of MyHC gene expression in myocytes.