• Title/Summary/Keyword: FA(Fly ash)

Search Result 260, Processing Time 0.025 seconds

The Strength Characteristics of Activated Multi-Component Cement with Kaolinite (카올린을 혼합한 활성화된 다성분계 시멘트의 강도 특성)

  • Kim, Tae-Wan;Kim, Im-Gon
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.5
    • /
    • pp.593-600
    • /
    • 2016
  • The paper presented investigates the effects of kaolinite on strength properties of alkali-activated multi-component cement. The binders of this study was blended of ground granulated blast furnace slag (GGBFS), fly ash (FA), silica fume (SF) and kaolinite (KA). In this study, the specimens of combination of 20%~70% GGBFS, 10%~60% FA, 10% SF (constant ratio) and 10%~50% KA binder were used for strength properties tests. The water/binder ratio was 0.5. The binders (GGBFS + FA + SF + KA) was activated by sodium hydroxide (NaOH) and sodium silicate ($Na_2SiO_3$) was 10% by total binder weight (10% NaOH + 10% $Na_2SiO_3$). The research carried out is on the compressive strength, water absorption, ultrasonic pulse velocity (UPV) and X-ray diffraction (XRD). The compressive strength decreased as the contents of KA increase. One of the major reason for this is the low reactivity of KA compared with other raw materials used as precursors such as GGBFS or FA. The presence of remaining KA indicates that the initially used quantity has not fully reacted during hydration. Moreover, the results have indicated that increased of KA contents decreased UPV under all experimental conditions. The drying shrinkage and water absorption increased as the content of KA increase. Test result clearly showed that the strength development of multi-component blended cement were significantly dependent on the content of KA and GGBFS.

Analysis of Permeability Characteristics for Fly Ash Concrete According to Aggregate Size and Mixing Ratio (골재크기와 배합비에 따른 플라이애시 콘크리트의 투기특성 분석)

  • Eun-A Seo;Do-Gyeum Kim;Chul-Woo Jung;Ho-Jae Lee
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.400-406
    • /
    • 2023
  • In this study, the relationship between the material properties and air permeability characteristics was examined, an experimental method to analyze the air permeability characteristics was presented, and experimental results were derived. The effects of compressive strength and apparent density of hardened concrete on air permeability characteristics were evaluated experimentally. Focusing on the mix proportions used in nuclear power plant concrete structures, concrete test specimens were manufactured and air permeability characteristics were measured according to changes in binder, maximum aggregate size, and water-binder ratio. The apparent density was over 2,400 kg/m3 for the OPC mix and the FA-35 mix, and the air permeability for both mixes were low, in the range of 0.1-0.2 L/min. On the other hand, in the case of the combination of FA-40, FA-45, and FA-M, the apparent density was measured to be less than 2,400 kg/m3 and the air permeability was measured to be more than 0.3 L/min, experimentally verifying that the apparent density is an important factor in air permeability characteristics.

Effects of High Temperature Maintenance Time and Curing Method on Compressive Strength of FA Large Volume Replacement Mortar after Application of Resuscitation Material (소생재 도포 후 고온 유지시간 및 양생방법 변화가 Fly Ash 다량치환 모르타르의 압축강도에 미치는 영향)

  • Choi, Yoon-Ho;Lee, Hyuk-Ju;Lee, Young-Jun;Hyun, Seung-Yong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.141-142
    • /
    • 2019
  • In this study, we conducted a comparative analysis of the effects of retention time and resuscitation method on the degree of resuscitation after reapplying mortar with much FA replacement. Results After applying NaOH to the top surface of 60 % FA-substituted mortar, the degree of resuscitation at $40^{\circ}C$ was high enough to increase the overall curing time, but there was no significant difference. However, with regard to the curing method, middle curing showed the greatest manifestation, followed by wrapping and underwater curing, but there was no significant difference. The resuscitation level on the 28th of the lumber was found to be revived to about 70~80 % at around 30 % without resuscitation.

  • PDF

The effects of replacement fly ash with diatomite in geopolymer mortar

  • Sinsiri, Theerawat;Phoo-ngernkham, Tanakorn;Sata, Vanchai;Chindaprasirt, Prinya
    • Computers and Concrete
    • /
    • v.9 no.6
    • /
    • pp.427-437
    • /
    • 2012
  • This article presents the effect of replacement fly ash (FA) with diatomite (DE) on the properties of geopolymer mortars. DE was used to partially replace FA at the levels of 0, 60, 80 and 100% by weight of binder. Sodium silicate ($Na_2SiO_3$) and sodium hydroxide (NaOH) solutions were used as the liquid portion in the mixture in order to activate the geopolymerization. The NaOH concentrations of 15M, $Na_2SiO_3$/NaOH ratios of 1.5 by weight, and the alkaline liquid/binder (LB) ratios by weight of 0.40, 0.50, 0.60 and 0.70 were used. The curing at temperature of $75^{\circ}C$ for 24 h was used to accelerate the geopolymerization. The flows of all fresh geopolymer mortars were tested. The compressive strengths and the stress-strain characteristics of the mortar at the age of 7 days, and the unit weights were also tested. The results revealed that the use of DE to replace part of FA as source material in making geopolymer mortars resulted in the increased in the workability, and strain capacity of mortar specimens and in the reductions in the unit weights and compressive strengths. The strain capacity of the mortar increased from 0.0028 to 0.0150 with the increase in the DE replacement levels from 0 to 100%. The mixes with 15M NaOH, $Na_2SiO_3$/NaOH of 1.5, LB ratio of 0.50, and using $75^{\circ}C$ curing temperature showed 7 days compressive strengths 22.0-81.0 MPa which are in the range of normal to high strength mortars.

Chloride Penetration Analysis of Fly Ash Concrete using Potentiometric Titration and XRF (플라이애시를 혼입한 콘크리트의 전위차 적정법과 XRF를 이용한 염화물 침투 분석 )

  • Eun-A Seo;Ji-Hyun Kim;Ho-Jae Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.16-22
    • /
    • 2023
  • In this study, a salt water immersion test was performed on concrete specimens simulating the concrete mix design of the nuclear power plant, and the correlation between the amount of chloride and the XRF component according to the depth of the concrete was analyzed. The amount of chloride on the surface of the nuclear power plant concrete increased slightly with increasing immersion time in salt water, but the amount of chloride in the depth of 5.5 mm or more showed a clear tendency to increase with increasing immersion time in salt water. As a result of analyzing the correlation between the amount of chloride in concrete and the XRF component, the concrete with 20% FA substitution compared with the OPC concrete showed a very high correlation between the composition ratio of Cl ions and the evaluation result of salt damage resistance by XRF component analysis. Accordingly, it was confirmed that chlorine ion analysis and salt damage resistance performance evaluation by XRF component analysis were possible through repeated data accumulation in the nuclear power plant concrete mix with 20% fly ash replacement.

Seawater Attack Resistance of Mortars Containing Mineral Admixtures (광물질혼화재 혼합 모르타르의 해수침식 저항성)

  • 문한영;이승태;최강식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.527-530
    • /
    • 2002
  • In the present study, immersion test using artificial seawater was performed to evaluate the resistance of mortar specimens with or without ground granulated blast-furnace slag (SG) and fly ash (FA). Another variable was the fineness levels of SG (4,450, 6,000 and 8,000 ㎠/g). From the results of the immersion test for 270 days of exposure, the excellent resistance to seawater attack for SG mortar mixtures, especially in a high fineness levels, was confirmed. However, the reductions in compressive strength of FA mortar specimens was similar to those of OPC mortar specimens irrespective of replacement of FA.. In order to understand the deterioration mechanism due to seawater attack, X-ray diffraction (XRD) analysis were also carried out. Some reactants such as ettringite, gypsum, brucite and Friedel's salt were possibly detected through XRD technique.

  • PDF

Effect of Silica Fume and Slag on Compressive Strength and Abrasion Resistance of HVFA Concrete

  • Rashad, Alaa M.;Seleem, Hosam El-Din H.;Shaheen, Amr F.
    • International Journal of Concrete Structures and Materials
    • /
    • v.8 no.1
    • /
    • pp.69-81
    • /
    • 2014
  • In this study, portland cement (PC) has been partially replaced with a Class F fly ash (FA) at level of 70 % to produce high-volume FA (HVFA) concrete (F70). F70 was modified by replacing FA at levels of 10 and 20 % with silica fume (SF) and ground granulated blast-furnace slag (GGBS) and their equally combinations. All HVFA concrete types were compared to PC concrete. After curing for 7, 28, 90 and 180 days the specimens were tested in compression and abrasion. The various decomposition phases formed were identified using X-ray diffraction. The morphology of the formed hydrates was studied using scanning electron microscopy. The results indicated higher abrasion resistance of HVFA concrete blended with either SF or equally combinations of SF and GGBS, whilst lower abrasion resistance was noted in HVFA blended with GGBS.

A Study of Rheological Properties on Cement Paste System Mixed with Mineral Admixtures (광물혼화재가 혼합된 시멘트 페이스트 시스템의 레올로지 특성에 관한 연구)

  • 박대효;노명현;박춘근
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.505-508
    • /
    • 2003
  • The rheological properties of cement paste system mixed with mineral admixture for the purpose of increasing the strength and improving durability and rheology of concrete were investigated. The results were as follows: The rheological properties of one-ingredient paste system were improved with increasing the dosage of superplasticizer. For two-ingredients paste system, increasing the replacement rate of BFS(blast furnace slag) and FA(fly ash), the yield value and plastic viscosity were decreased compared with non-replacement. In the OPC(ordinary portland cement)-SF(silica fume) system, increasing the replacement rate of SF, the plastic viscosity and yield value increased linearly. In three-ingredients paste system, both OPC-BFS-SF and OPC-FA-SF system, the rheological properties were improved compared with the only replacement of SF. Both two- and three- ingredients paste system, the rheological properties using BFS were improved more than FA.

  • PDF

A Study on the Rheology Properties of Cement Paste with Variation of Quantity and! Type of Mineral Admixture (광물혼화재의 종류별 함량에 따른 시멘트 페이스트의 유동 특성에 관한 연구)

  • 박춘근;노명현;김학연;이종필;박대효
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.107-113
    • /
    • 2003
  • The rheology properties of cement paste with variation of quantity and type of mineral admixture were investigated. The rheology of the paste was assessed by using a HAAKE Rotovisco(RT 20) rheometer having cylindrical serrate spindle. The results were as follows: The viscosity and the yield stress of cement paste were decreased by the only replacement of 10% BFS(blast furnace slag) or the only replacement of 30% FA(fly ash), whereas SF(silica fume) increased them as the replacement quantity was increased. Increasing the dosage of HRWR(high-range water reducer), the rheology properties were improved significantly in cement paste with the replacement of SF. In addition, rheology properties of two ingredient blended pastes, such as BFS(20%)-SF(5%), FA(20%)-SF(5%), were improved more than those of three ingredient blended paste, BFS(20%)-FA(20%)-SF(5%).

  • PDF

Utilization of Improved Durometer when Estimating Setting Time of FA Replacement Concrete Using CGS for Fine Aggregate (CGS를 잔골재로 활용하는 FA치환 콘크리트의 응결시간 추정시 개량형 듀로미터 사용 가능성 분석)

  • Lee, Hyuk-Ju;Shin, Yong-Sub;Seo, Hang-Goo;Han, In-Deok;Han, Min-Choel;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.81-82
    • /
    • 2019
  • In this study, the Proctor penetration resistance test value and the hardness value of the improved Durometer were compared and analyzed for the change in the FA replacement rate of the concrete using CGS fine aggregate. The results are summarized as follows. It is. 1) The Proctor penetration resistance test value and the hardness value of the improved Durometer showed a high correlation in the form of a curve. 2) About surface finish Super-resolution with the improved Durometer is considered to be useful when using about 50 HD and about 80 HD in the end to determine the surface finishing work time.

  • PDF