• Title/Summary/Keyword: F1_Weighted

Search Result 159, Processing Time 0.028 seconds

Automated Areal Feature Matching in Different Spatial Data-sets (이종의 공간 데이터 셋의 면 객체 자동 매칭 방법)

  • Kim, Ji Young;Lee, Jae Bin
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.1
    • /
    • pp.89-98
    • /
    • 2016
  • In this paper, we proposed an automated areal feature matching method based on geometric similarity without user intervention and is applied into areal features of many-to-many relation, for confusion of spatial data-sets of different scale and updating cycle. Firstly, areal feature(node) that a value of inclusion function is more than 0.4 was connected as an edge in adjacency matrix and candidate corresponding areal features included many-to-many relation was identified by multiplication of adjacency matrix. For geometrical matching, these multiple candidates corresponding areal features were transformed into an aggregated polygon as a convex hull generated by a curve-fitting algorithm. Secondly, we defined matching criteria to measure geometrical quality, and these criteria were changed into normalized values, similarity, by similarity function. Next, shape similarity is defined as a weighted linear combination of these similarities and weights which are calculated by Criteria Importance Through Intercriteria Correlation(CRITIC) method. Finally, in training data, we identified Equal Error Rate(EER) which is trade-off value in a plot of precision versus recall for all threshold values(PR curve) as a threshold and decided if these candidate pairs are corresponding pairs or not. To the result of applying the proposed method in a digital topographic map and a base map of address system(KAIS), we confirmed that some many-to-many areal features were mis-detected in visual evaluation and precision, recall and F-Measure was highly 0.951, 0.906, 0.928, respectively in statistical evaluation. These means that accuracy of the automated matching between different spatial data-sets by the proposed method is highly. However, we should do a research on an inclusion function and a detail matching criterion to exactly quantify many-to-many areal features in future.

Evaluation of MR Based Respiratory Motion Correction Technique in Liver PET/MRI Study (Liver PET/MRI 검사 시 MR 기반 호흡 움직임 보정 방법의 유용성 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2018
  • Purpose Respiratory motion during PET/MRI acquisition may result in image blurring and error in measurement for volume and quantification of lesion. The aim of this study was to evaluate changes of quantitative accuracy, tumor size and image quality by applying MR based respiratory motion correction technique (MBRMCT) using integrated PET/MR scanner. Materials and Methods Data of 30 patients (aged $62.5{\pm}10.2y$) underwent $^{18}F-FDG$ liver PET/MR (Biograph mMR 3.0T, Siemens) study were collected. PET listmode data for 7 minutes was simultaneously acquired with maximum average gate (MAG), minimum time gate (MTG) and non gate (NG) T1 weighted MR images. Gated PET reconstruction was performed using mu-maps generated from MAG and MTG by setting 35% of efficiency window. Maximum SUV ($SUV_{max}$), peak SUV ($SUV_{peak}$), tumor size and full width at half maximum (FWHM) in the z-axis direction of MAG, MTG and NG PET images were evaluated. Results Compared to NG, mean $SUV_{max}$ and $SUV_{peak}$ were increased in MAG 13.15%(p<0.0001), 8.66%(p<0.0001), MTG 13.27%(p<0.0001), 8.80%(p<0.0001) and mean tumor size and FWHM were decreased in MAG 14.47%(p<0.0001), 15.49%(p=0.0004), MTG 14.89%(p<0.0001), 15.79%(p=0.0003) respectively. Mean $SUV_{max}$ and $SUV_{peak}$ of MTG were increased by 0.07%(p=0.8802), 0.13%(p=0.7766). Mean tumor size and FWHM of MTG were decreased by 0.49%(p=0.2786), 0.36%(p=0.2488) compared to MAG. There was no statistically significant difference between MAG and MTG which increase total scan time for about 7 and 2 minutes. Conclusion SUV, accuracy of tumor size and spatial resolution were improved in both of MAG and MTG by applying MBRMCT without installing additional hardware in liver PET/MR study. More accurate information can be provided with the increase of 2 minutes scan time if applying MTG of MBRMCT to various abdominal PET/MR studies affected by respiratory motion.

A Study on the Quality Assuranc of Chemical Analysis Data of Precipitation Samples (강수 분석자료의 신뢰성 검토에 관한 연구)

  • 강공언
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.3
    • /
    • pp.85-98
    • /
    • 1995
  • In order to ensure that all major cations and anions were accurately measured, the quality assurance checks of chemical analysis data by considering ion and conductivity balance of each precipitation sample were performed. To check the quality assurance of chemical analysis data, precipitation samples were collected by wet- only precipitation sampler at Seoul site and their chemical components were analyzed. By checking the problems for the screening methods of chemical analysis data used until recently, the f value expressed as the ratio of the sum of cations and anions equivalent concentration( $\Sigma $C/$\Sigma $A ) was found to be not ap priorate for data screening. Also, the scattering plot between cation and anion equivalent concentrations in each sample was found to show the general tendency of ion balance but was proved to not quantitate the standard of data screening at a set of samples of various concentration levels.4 more appropriate value was therefore required, h value is defined as (A-C)/C for C≥A and ( A-C)/A for C<4. This value was showed to check the ion balance in a viewpoint of quantitative as well as qualitative and to be useful in applying this expression to a measurement data set. However, the standard o( data screening must vary in response to the ion concentration of sample. In this study, the quality assurance of chemical analysis data was checked by considering both the ion balance evaluating by h value and the electrical conductivity. As these quality assurance checks were applied to Seoul data serf 67 valid samples were obtained. The result of statistical summary in the analytical parameter of precipitation samples collected for a certain period was found to be computed in the precipitation volume- weighted mean( VWM) rather than the arithmetic mean( AM), but PH In the VWM of hydrogen ion concentration. The annual VWM of pH values was 5.0(4.9 ∼ 5.1).

  • PDF

An Analysis of Long-term Trends in Precipitation Acidity of Seoul, Korea (서울지역 강수 산성도의 장기적인 경향분석)

  • 강공언;임재현;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.1
    • /
    • pp.9-18
    • /
    • 1997
  • Precipitation samples were collected by the wet- only event sampling method from Seoul during September 1991 to April 1995. These samples were analyzed for the concentrations of the major ionic components (N $O_3$$^{[-10]}$ , N $O_2$$^{[-10]}$ , S $O_4$$^{2-}$, C $l^{[-10]}$ , $F^{[-10]}$ , N $a^{+}$, $K^{+}$, $Ca^{2+}$, $Mg^{2+}$, and N $H_4$$^{+}$), pH, and electric conductivity. During the study period, a total of 182 samples were collected, but only 163 samples were used for the data analysis via quality assurance of precipitation chemistry data. The volume-weighted pH was found to be 4.7. The major acidifying species from our precipitation studies were identified to be non-seasalt sulfate (84$\pm$9 $\mu$eq/L) and nitrate (24$\pm$2 $\mu$eq/L) except for chloride. Because the Cl/Na ratio in the precipitation was close to the ratio in seawater. If all of the non-seasalt sulfate and nitrate were in the form of sulfuric and nitric acids, the mean pH in the precipitation could have been as low as 3.7 lower than the computed value. Consequently, the difference between two pH values indicate that the acidity of precipitation was neutralized by alkaline species. The equivalent concentration ratio of sulfate to nitrate was 3.5, indicating that sulfuric and nitric acids can comprise 78% and 22% of the precipitation acidity, respectively. Analysis of temporal trend in the measured acidity and ionic components were also performed using the linear regression method. The precipitation acidity generally showed a significantly decreasing trend, which was compatible with the pattern of the ratio (N $H_4$$^{+}$+C $a^{2+}$)/ (nss-S $O_4$$^{2-}$+N $O_3$$^{[-10]}$ ).).

  • PDF

Disrupted Association Between Empathy and Brain Structure in Attention-Deficit/Hyperactivity Disorder

  • Lee, Jeonghwan;Son, Jung-Woo;Kim, Siekyeong;Kim, Ji-eun;Chung, Seungwon;Ghim, Hei-Rhee;Lee, Sang-Ick;Shin, Chul-Jin;Ju, Gawon
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.32 no.4
    • /
    • pp.129-136
    • /
    • 2021
  • Objectives: To investigate the relationship between brain structure and empathy in early adolescents with attention-deficit/hyperactivity disorder (ADHD). Methods: Nineteen early adolescents with ADHD and 20 healthy controls underwent 3T MRI. All the participants were assessed for different aspects of empathy using measures including the Interpersonal Reactivity Index and Empathy Quotient. Cortical thickness and subcortical structural volume based on T1-weighted scans were analyzed using FreeSurfer. Results: Cognitive empathy (t=-2.52, p=0.016) and perspective taking (t=-2.10, p=0.043) were impaired in the ADHD group compared with the control group. The cluster encompassing the left posterior insular, supramarginal, and transverse temporal cortices [cluster-wise p-value (CWP)=0.001], which are associated with emotional empathy, was significantly smaller in the ADHD group, and the volume of the left nucleus accumbens was greater than that of the control group (F=10.12, p=0.003, effect size=0.22). In the control group, the left superior temporal (CWP=0.002) and lingual cortical (CWP=0.035) thicknesses were positively associated with cognitive empathy, while the right amygdala volume was positively associated with empathic concern (Coef=14.26, t=3.92, p=0.001). However, there was no significant correlation between empathy and brain structure in the ADHD group. Conclusion: The ADHD group had a smaller volume of the cortical area associated with emotional empathy than the control group, and there was no brain region showing significant correlation with empathy, unlike in the control group.

A Study on Multilayer Sub-contracting in Construction Industry of Hong Kong

  • Cheng, T.F.;Lam, H.C.;Leung, K.L.;Liu, W.T.;Zayed, Tarek;Sun, Yi
    • International conference on construction engineering and project management
    • /
    • 2020.12a
    • /
    • pp.23-29
    • /
    • 2020
  • Multilayer sub-contracting is a significant practice among the world, including Hong Kong. When a principal contractor secured a project from a developer, the specific jobs will usually be breaking down and sub-contractors with the lowest bid [1]. The adoption of multilayer sub-contracting has been a controversy issue which is considered as a two-side blade. While certain studies have been carried out to examine both the contributions, damages and improvements for multi-layer subcontracting, the construction industry and researchers are still waiting for a solid measure to enhance the system. Hence, this research attempts to study the advantages, disadvantages, conducts a comparison between single and multilayer sub-contracting and measures of current Hong Kong construction industry based on literature review, questionnaire and in-depth interviews. To achieve the objectives, Analytic Hierarchy Process (AHP) and total weighted score methods are adopted to examine and rank the criterion. The findings of this study provide a good basis for understanding the major reasons and problems caused by the adoption of multilayer sub-contracting. Besides, the identified safety perspective explores a new perspective regarding to issues of multi-layer subcontracting, which will serve as a solid foundation for further research to enhance safety performance. Finally, the findings of measurements towards improvement of multilayer sub-contracting will also provide a solidsolution for construction industry.

  • PDF

Transient Splenial Lesions in the Splenium of Corpus Callosum in Seven Patients: MR Findings and Clinical Correlations (뇌량 팽대의 일과성 병변: 7명의 환자에서의 자기공명 영상소견과 임상 양상의 연관성)

  • Park, Ju Young;Lee, In Ho;Song, Chang June;Hwang, Hee Youn
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Purpose : The purpose of this study is to correlate the imaging findings and the clinical findings in patients with transient splenial lesions (TSL). Materials and Methods: Total of 7 patients (M: F = 4: 3; age range 11 - 38 years, mean age 25.5 years) were studied between November 2006 and April 2011. The MRI findings and clinical findings in all patients were retrospectively reviewed. The location, MR signal intensity, restricted diffusion, enhancement pattern and reversibility from the follow up images were reviewed. Clinical features were reviewed with respect to the presented symptoms, signs, treatment and outcome. Results: The lesions were located in the splenium of corpus callosum in all patients. All lesions showed high signal intensity on diffusion weighted imaging (DWI), and six patients showed restricted diffusion on the apparent diffusion coefficient (ADC) map. ADC map was not available in one patient. All lesions (n = 7) showed high signal intensity on the T2 weighted image (T2WI). Five of the patients (71.4%) with follow up images (range 7 - 34 days) showed complete resolution of focal high signal intensity on DWI, with recovery of ADC values as well as T2WI. After contrast media administration, none of the lesions showed any enhancements. All lesions with various etiologies including TB medication were developed in younger age patients and showed reversibility after the acceptable period of minimum 7 days with conservative treatment. Conclusion: All TSL showed nonspecific imaging findings, including restricted diffusion on DWI and ADC map on the initial images. However, reversibility of the lesions and the young age preference can be a characteristic finding of TSL with acceptable period of minimum 7 days. In addition, to keep it in mind that various etiologies including TB medication may cause TSL, is important for radiologists as well as clinicians.

Ionic composition and pollution characteristics of precipitation in Jeju Island during 2009-2014 (2009-2014년 제주지역 강수의 이온조성 및 오염특성)

  • Bu, Jun Oh;Song, Jung Min;Shin, Su Hyun;Kim, Won Hyung;Kang, Chang Hee
    • Analytical Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.19-28
    • /
    • 2016
  • The objective of this study was to determine the acidification of precipitation in the Jeju area. Precipitation samples were collected from the Jeju area from 2009-2014, and the major ionic species were analyzed. In the regression analysis, through a comparison of ion balance, electric conductivity, and acid fraction, the correlation coefficients showed a good linear relationship within the range of 0.927~0.983. The volume-weighted means of the pH and electric conductivity were 4.9 and 22.7 µS/cm, respectively. The ionic strength of precipitation was 0.27±0.38 mM, indicating about 35.9 % of total precipitation within the pure precipitation criteria. The volume-weighted mean concentrations (ìeq/L) of the ionic species in the precipitation were in the order of Na+ > Cl > nss-SO42− > NO3 > NH4+ > Mg2+ > H+ > nss-Ca2+ > PO43− > K+ > HCOO > CH3COO > NO2 > F > HCO3 > CH3SO3 . The acidification contributions by sulfuric and nitric acids were 54.5 % and 36.5 %, respectively. Meanwhile the acidification contributions by formic and acetic acids were 4.8 % and 4.2 %, respectively. Thus, it was found that the acidification of the precipitation in the Jeju area was mainly due to the inorganic acids. The neutralization factors by NH3 and CaCO3 were also 33 % and 20 %, respectively.

Usefulness of Registration in the Evaluation of Parkinson′s Disease (영상 융합하여 분석한 파킨슨씨병 환자영상의 유용성)

  • 주라형;김재승;문대혁;최보영;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.268-278
    • /
    • 2003
  • Purpose:The aim of this study was to evaluate the striatal binding ratio, the anterior/posterior ratio and reproducibility using a template based registration method using the standard MR template as a replacement for each patients MR image. Materials and Methods:This study analyzed the 123I IPT SPECT images of 30 patients with IPD, who were subdivided into 17 patients (56.6$\pm$10.8 yr, M/F : 8/9.) with mild IPD, and 13 patients (56.4$\pm$11.1 yr, M/F : 8/5) with severe IPD. In addition, 11 normal controls (57.8$\pm$14.4 yr, M/F : 4/7) were also analyzed. The ROIs were positioned manually in the same slice showing the highest striatal activity using the traditional manual method, whereas those were positioned automatically in a mid striatal slice of the SPECT image coregistered to the standard T1 weighted MR template. Results : The specific binding ratio (SBR) obtained using the template based registration method strongly correlated with those using the manual method in all groups : normal controls (r=0.85, P<0.001), mild IPD (r=0.84, P<0.001) and severe IPD (r=0.7, P=0.01). The SBRs obtained using both methods were significantly different among the three groups (P=0.05) and the SBRs obtained by the template based registration method were higher than those by the manual method (P=0.05) in all three groups. The APRs obtained by the template based registration correlated with those using manual method in only mild IPD (r=0.72, P=0.0). The APRs obtained by the template based registration method were significantly different from the normal controls and those with mild or severe IPD (P<0.05), whereas those obtained using the manual method were not significantly different among the three groups (P>0.1). The reproducibility (rmsCV) of the template based registration method was 7.2% (normal controls:5.2%, mild IPD:4.2%, severe IPD:10.8%), whereas the reproducibility of the manual method was 31% (normal controls:19.7%, mild IPD:21.7%, severe IPD:46.2%). Conclusion:These results show that the use of $^{123}$ I-IPT SPECT for assessing IPD is affected by the methods used to position the striatal ROI. The template based registration method using the standard MR template can be useful in diagnosing IPD and assessing the disease severity with a high reproducibility. Therefore, the template based registration method appears to be a good replacement for the manual method.

  • PDF

Effect of the Dose Reduction Applied Low Dose for PET/CT According to CT Attenuation Correction Method (PET/CT 저선량 적용 시 CT 감쇠보정법에 따른 피폭선량 저감효과)

  • Jung, Seung Woo;Kim, Hong Kyun;Kwon, Jae Beom;Park, Sung Wook;Kim, Myeong Jun;Sin, Yeong Man;Kim, Yeong Heon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.127-133
    • /
    • 2014
  • Purpose: Low dose of PET/CT is important because of Patient's X-ray exposure. The aim of this study was to evaluate the effectiveness of low-dose PET/ CT image through the CTAC and QAC of patient study and phantom study. Materials and Methods: We used the discovery 710 PET/CT (GE). We used the NEMA IEC body phantom for evaluating the PET data corrected by ultra-low dose CT attenuation correction method and NU2-94 phantom for uniformity. After injection of 70.78 MBq and 22.2 MBq of 18 F-FDG were done to each of phantom, PET/CT scans were obtained. PET data were reconstructed by using of CTAC of which dose was for the diagnosis CT and Q. AC of which was only for attenuation correction. Quantitative analysis was performed by use of horizontal profile and vertical profile. Reference data which were corrected by CTAC were compared to PET data which was corrected by the ultra-low dose. The relative error was assessed. Patients with over weighted and normal weight also underwent a PET/CT scans according to low dose protocol and standard dose protocol. Relative error and signal to noise ratio of SUV were analyzed. Results: In the results of phantom test, phantom PET data were corrected by CTAC and Q.AC and they were compared each other. The relative error of Q.AC profile was been calculated, and it was shown in graph. In patient studies, PET data for overweight patient and normal weight patient were reconstructed by CTAC and Q.AC under routine dose and ultra-low dose. When routine dose was used, the relative error was small. When high dose was used, the result of overweight patient was effectively corrected by Q.AC. Conclusion: In phantom study, CTAC method with 80 kVp and 10 mA was resulted in bead hardening artifact. PET data corrected by ultra- low dose CTAC was not quantified, but those by the same dose were quantified properly. In patients' cases, PET data of over weighted patient could be quantified by Q.AC method. Its relative difference was not significant. Q.AC method was proper attenuation correction method when ultra-low dose was used. As a result, it is expected that Q.AC is a good method in order to reduce patient's exposure dose.

  • PDF