• Title/Summary/Keyword: F127

Search Result 308, Processing Time 0.029 seconds

Study of 68Ga Labelled PET/CT Scan Parameters Optimization (68Ga 표지 PET/CT 검사의 최적화된 매개변수에 대한 연구)

  • In Suk Kwak;Hyuk Lee;Si Hwal Kim;Seung Cheol Moon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.111-127
    • /
    • 2023
  • Purpose: Gallium-68 (68Ga) is increasingly used in nuclear medicine imaging for various conditions such as lymphoma and neuroendocrine tumors by labeling tracers like Prostate Specific Membrane Antigen (PSMA) and DOTA-TOC. However, compared to Fluorine-18 (18F) used in conventional nuclear medicine imaging, 68Ga has lower spatial resolution and relatively higher Signal to Background Ratio (SBR). Therefore, this study aimed to investigate the optimized parameters and reconstruction methods for PET/CT imaging using the 68Ga radiotracer through model-based image evaluation. Materials and Methods: Based on clinical images of 68Ga-PSMA PET/CT, a NEMA/IEC 2008 PET phantom model was prepared with a Hot vs Background (H/B) ratio of 10:1. Images were acquired for 9 minutes in list mode using DMIDR (GE, Milwaukee WI, USA). Subsequently, reconstructions were performed for 1 to 8 minutes using OS-EM (Ordered Subset Expectation Maximization) + TOF (Time of Flight) + Sharp IR (VPFX-S), and BSREM (Block Sequential Regularized Expectation Maximization) + TOF + Sharp IR (QCFX-S-400), followed by comparative evaluation. Based on the previous experimental results, images were reconstructed for BSREM + TOF + Sharp IR / 2 minutes (QCFX-S-2min) with varying β-strength values from 100 to 700. The image quality was evaluated using AMIDE (freeware, Ver.1.0.1) and Advanced Workstation (GE, USA). Results: Images reconstructed with QCFX-S-400 showed relatively higher values for SNR (Signal to Noise Ratio), CNR (Contrast to Noise Ratio), count, RC (Recovery Coefficient), and SUV (Standardized Uptake Value) compared to VPFX-S. SNR, CNR, and SUV exhibited the highest values at 2 minutes/bed acquisition time. RC showed the highest values for a 10 mm sphere at 2 minutes/bed acquisition time. For small spheres of 10 mm and 13 mm, an inverse relationship between β-strength increase and count was observed. SNR and CNR peaked at β-strength 400 and then decreased, while SUV and RC exhibited a normal distribution based on sphere size for β-strength values of 400 and above. Conclusion: Based on the experiments, PET/CT imaging using the 68Ga radiotracer yielded the most favorable quantitative and qualitative results with a 2 minutes/bed acquisition time and BSREM reconstruction, particularly when applying β-strength 400. The application of BSREM can enhance accurate quantification and image quality in 68Ga PET/CT imaging, and an optimization process tailored to each institution's imaging objectives appears necessary.

Cardiac Phenotyping of SARS-CoV-2 in British Columbia: A Prospective Echo Study With Strain Imaging

  • Jeffrey Yim;Michael Y.C. Tsang;Anand Venkataraman;Shane Balthazaar;Ken Gin;John Jue;Parvathy Nair;Christina Luong;Darwin F. Yeung;Robb Moss;Sean A Virani;Jane McKay;Margot Williams;Eric C. Sayre;Purang Abolmaesumi;Teresa S.M. Tsang
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.3
    • /
    • pp.125-132
    • /
    • 2023
  • BACKGROUND: There is limited data on the residual echocardiographic findings including strain analysis among post-coronavirus disease (COVID) patients. The aim of our study is to prospectively phenotype post-COVID patients. METHODS: All patients discharged following acute COVID infection were systematically followed in the post-COVID-19 Recovery Clinic at Vancouver General Hospital and St. Paul's Hospital. At 4-18 weeks post diagnosis, patients underwent comprehensive echocardiographic assessment. Left ventricular ejection fraction (LVEF) was assessed by 3D, 2D Biplane Simpson's, or visual estimate. LV global longitudinal strain (GLS) was measured using a vendor-independent 2D speckle-tracking software (TomTec). RESULTS: A total of 127 patients (53% female, mean age 58 years) were included in our analyses. At baseline, cardiac conditions were present in 58% of the patients (15% coronary artery disease, 4% heart failure, 44% hypertension, 10% atrial fibrillation) while the remainder were free of cardiac conditions. COVID-19 serious complications were present in 79% of the patients (76% pneumonia, 37% intensive care unit admission, 21% intubation, 1% myocarditis). Normal LVEF was seen in 96% of the cohort and 97% had normal right ventricular systolic function. A high proportion (53%) had abnormal LV GLS defined as < 18%. Average LV GLS of septal and inferior segments were lower compared to that of other segments. Among patients without pre-existing cardiac conditions, LVEF was abnormal in only 1.9%, but LV GLS was abnormal in 46% of the patients. CONCLUSIONS: Most post-COVID patients had normal LVEF at 4-18 weeks post diagnosis, but over half had abnormal LV GLS.

Similarities of Scaritoxin to Ciguatoxin on the Chromatographic Behaviours (Scaritoxin과 Ciguatoxin의 크로마토그라피상에서의 몇가지 유사성)

  • Joh, Yong-Goe;Scheuer, Paul J.
    • Korean Journal of Food Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.121-127
    • /
    • 1985
  • In studying the structural work on ciguatoxin, parrot fish collected were identified as Scarus sordidus, S. frenatus, S. scaber and S. pectarlis, in which only S. sordidus contained toxic materials. Crude toxins obtained by silicic acid column chromatography, could be separated on a DEAE-cellulose column into two fractions, ST-1(less polar) and ST-2(polar) eluted with chloroform and chloroform-methanol(1:1). Furthermore ST-1 could be changed into ST-2 by repeated chromatography on DEAE-cellulose. Rf values of ST-1 and ST-2 were 0.60-0.75 and 0.30-0.54 on TLC coated with silica gel 60F-254 developed by chloroform-methanol-water-acetic acid (90:9.5:0.2:0.3) mixture. The peaks of ST-1 and ST-2 were not observed on each HPLC chromatogram at low sensitivity(2X), but by bioassay they were detected in the fraction of 24-27ml(less polar toxin, 120ng) and 22-27 ml (polar toxin, 150 ng). Less polar ciguatoxin from morey eel viscera also showed its peak in the same elution volume(25ml). Being subjected to chromatography on basic aluminum oxide (activity grade I) or to alkaline treatment, followed by basic aluminum oxide (activity grade I) chromatography ST-1 toxin was remarkably converted into the polar toxic component supposed to be polar ciguatoxin in both cases. In the latter case, approximately 74% of the residual toxicity was changed into the polar component, accompanied by about 50% loss of the initial toxicity. More than 26% of ST-2 toxicity was transformed into the less polar toxic component supposed to be less polar ciguatoxin on a deactivated aluminum oxide (activity grade V) column.

  • PDF

Effect of the Dose Reduction Applied Low Dose for PET/CT According to CT Attenuation Correction Method (PET/CT 저선량 적용 시 CT 감쇠보정법에 따른 피폭선량 저감효과)

  • Jung, Seung Woo;Kim, Hong Kyun;Kwon, Jae Beom;Park, Sung Wook;Kim, Myeong Jun;Sin, Yeong Man;Kim, Yeong Heon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.127-133
    • /
    • 2014
  • Purpose: Low dose of PET/CT is important because of Patient's X-ray exposure. The aim of this study was to evaluate the effectiveness of low-dose PET/ CT image through the CTAC and QAC of patient study and phantom study. Materials and Methods: We used the discovery 710 PET/CT (GE). We used the NEMA IEC body phantom for evaluating the PET data corrected by ultra-low dose CT attenuation correction method and NU2-94 phantom for uniformity. After injection of 70.78 MBq and 22.2 MBq of 18 F-FDG were done to each of phantom, PET/CT scans were obtained. PET data were reconstructed by using of CTAC of which dose was for the diagnosis CT and Q. AC of which was only for attenuation correction. Quantitative analysis was performed by use of horizontal profile and vertical profile. Reference data which were corrected by CTAC were compared to PET data which was corrected by the ultra-low dose. The relative error was assessed. Patients with over weighted and normal weight also underwent a PET/CT scans according to low dose protocol and standard dose protocol. Relative error and signal to noise ratio of SUV were analyzed. Results: In the results of phantom test, phantom PET data were corrected by CTAC and Q.AC and they were compared each other. The relative error of Q.AC profile was been calculated, and it was shown in graph. In patient studies, PET data for overweight patient and normal weight patient were reconstructed by CTAC and Q.AC under routine dose and ultra-low dose. When routine dose was used, the relative error was small. When high dose was used, the result of overweight patient was effectively corrected by Q.AC. Conclusion: In phantom study, CTAC method with 80 kVp and 10 mA was resulted in bead hardening artifact. PET data corrected by ultra- low dose CTAC was not quantified, but those by the same dose were quantified properly. In patients' cases, PET data of over weighted patient could be quantified by Q.AC method. Its relative difference was not significant. Q.AC method was proper attenuation correction method when ultra-low dose was used. As a result, it is expected that Q.AC is a good method in order to reduce patient's exposure dose.

  • PDF

A Study on the adequate Aggregate Selection of the Exposed Aggregate PCC Pavements (골재노출 콘크리트포장의 적정 골재 선정에 대한 연구)

  • Kim, Young-Kyu;Chae, Sung-Wook;Lee, Seung-Woo;Yoo, Tae-Seok
    • International Journal of Highway Engineering
    • /
    • v.9 no.4
    • /
    • pp.117-127
    • /
    • 2007
  • The exposed aggregate PCC(EAP) pavements have been successfully used in Europe and Japan as low-noise pavements. Coarse aggregate are exposed on the pavement surface texture of EAP by removing mortar of surface. The pavement surface texture should maintain not only low-noise characteristic but also adequate skid resistance level during the performance period. Skid resistance decreased with wearing and polishing of tire and pavement surface due to the repetition of tire-pavement contact. Since the tires mainly contact the exposed coarse aggregate, the shape and rock type of coarse aggregate significantly influence wearing and polishing of EAP pavements. The test for resistance to abrasion coarse aggregate by use of the Los Angeles machine(KS F 2508) and the method of test for resistance to abrasion coarse aggregate by use of the Accelerated Polishing Machine(ASTM D 3319-90) are generally used to evaluate polishing characteristics of aggregate. In this study, polishing of coarse aggregate of different five rock types were evaluated by KS F 2508(LA abrasion test) and ASTM D 3319-90(PSV method). The results of LA abrasion test and PSV method were contrary to each other. Since LA abrasion test is estimated the quantity of abrasion by the impact of aggregate, it may not be adequate to evaluate the polishing of aggregate by the repetition of tire. In the case of PSV method, the resistance of polishing is estimated the skid resistance variation of polished aggregate after repetition of tire. The PSV method is adequate for the evaluation on polishing of coarse aggregate. From the test results of PSV method, it was founded that rock type, specific gravity, coarse aggregate angularity, flat or elongated particles in coarse aggregate are significant to the resistance characteristic of coarse aggregate.

  • PDF

Incidence of Fusarium Wilt of Sesame (Sesamum indicum L.) in Relation to Air Temperature (참깨 시들음병(病) 발병(發病)과 재배기간중(栽培期間中) 온도(溫度)와의 관계(關係))

  • KANG, S.W.;CHO, D.J.;Lee, Y.S.
    • Korean journal of applied entomology
    • /
    • v.24 no.3 s.64
    • /
    • pp.123-127
    • /
    • 1985
  • Incidence of the Fusarium wilt caused by F. oxysporum f. sp. vasinfectum of sesame (var. Kwangsan) was remarkably influenced by seeding date and mean air temperature in the field of two or three year's continuous cropping with sesame in 1983 and 1985. Sesame were seeded on six different dates from April 20 to July 5. Air temperature was checked daily at the meteorological station near the experimental field. Low($16{\sim}20^{\circ}C$) and high temperature($20{\sim}25^{\circ}C$) periods were provisionally devided, based on every ten-day mean daily temperature during field experiment for last ten years, which corresponded to before and after June 15 in Jinju, Gyeong-nam. Infection rates were 83.7%, 68.2% and 59.4% in the plants grown for 55 days (seeding date: April 20), 40 days(May 5) and 25 days(May 20) under low temperature. On the other hand, infection rates were below 3% in those plots seeded during high temperature period. The longer the growth period exposed to low temperature, the higher was infection rates. It is interesting to note that 40 days old seedling or older are prone to severe infection compared to the younger ones, in higher temperature of $20{\sim}25^{\circ}C$. Therefore, seedlings in vegetative growth stage are less prone to infection than these in reproductive growth stage. The result showed that air temperature during sesame growth was one of the most important factor affecting the incidence of Fusarium wilt. This suggested that sesame crop, which is of tropical origin, has been predisposed to Fusarium wilt, when the plants were exposed to low temperature of $16{\sim}20^{\circ}C$.

  • PDF

Use of Noninvasive Mechanical Ventilation in Acute Hypercapnic versus Hypoxic Respiratory Failure (급성 환기부전과 산소화부전에서 비침습적 환기법의 비교)

  • Lee, Sung Soon;Lim, Chae-Man;Kim, Baek-Nam;Koh, Younsuck;Park, Pyung Hwan;Lee, Sang Do;Kim, Woo Sung;Kim, Dong Soon;Kim, Won Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.6
    • /
    • pp.987-996
    • /
    • 1996
  • Background : We prospectively evaluated the applicability and effect of noninvasive ventilation (NIV) in acute respiratory failure and tried to find out the parameters that could predict successful application of NIV. Methods : Twenty-six out of 106 patients with either acute ventilatory failure (VF: $PaCO_2$ > 43 mm Hg with pH < 7.35) or oxygenation failure (OF: $PaO_2/AO_2$ < 300 mm Hg with $pH{\geq}7.35$) requiring mechanical ventilation were managed by NIV (CPAP + pressure suppon, or BiPAP) with face mask. Eleven out of 19 cases with VF (57.9%) (M : F=7 : $55.4{\pm}14.6$ yrs) and 15 out of 87 cases with OF (17.2%) (M : F=12 : 3, $50.6{\pm}15.6$ yrs) were s uilable for NIY. Respiratory rates, arterial blood gases and success rate of NIV were analyzed in each group. Results: 81.8% (9/11) of YF and 40% (6/15) of OF were successfully managed on NIV and were weruled from mechanical ventilator without resorting to endotracheal intubation. Complications were noted in 2 cases (nasal skin necrosis 1, gaseous gastric distension 1). In NIV for ventilatory failure, the respiration rate was significantly decreased at 12 hour of NIV ($34{\pm}9$ /min pre-NIV, $26{\pm}6$ /min at 12 hour of NIV, p=0.045), while $PaCO_2$ ($87.3{\pm}20.6$ mm Hg pre-NIV, $81.2{\pm}9.1$ mm Hg at 24 hour of NIV) and pH ($7.26{\pm}0.04$, $7.32{\pm}0.02$, respectively, p <0.05) were both significantly decreased at 24 hour of NIV In NIV for oxygenation failure, $PaCO_2$ were not different between the successful and the failed cases at pre-NIV and till 12 hours after NIV. The $PaO_2/FIO_2$ ratio, however, significantly improved at 0.5 hour of NIV in successful cases and were maintained at around 200 mm Hg (n=6 : at baseline, 0.5h, 6h, 12h : $120.0{\pm}19.6$, $218.9{\pm}98.3$, $191.3{\pm}55.2$, $232.8{\pm}17.6$ mm Hg, respectively, p=0.0211), but it did not rise in the failed cases (n=9 : $127.9{\pm}63.0$, $116.8{\pm}24.4$, $100.6{\pm}34.6$, $129.8{\pm}50.3$ mm Hg, respectively, p=0.5319). Conclusion : From the above results we conclude that NIV is effective for hypercapnic respiratory failure and its success was heralded by reduction of respiration rale before the reduction in $PaCO_2$ level. In hypoxic respiratory failure, NIV is much less effective, and the immediate improvement of $PaO_2/FIO_2$ ratio at 0.5h after application is thought to be a predictor of successful NIV.

  • PDF

A Study on the Surgical Hand Scrub and Surgical Glove Perforation (외과적 손씻기 및 외과용 장갑의 천공율에 대한 연구)

  • 윤혜상
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.4
    • /
    • pp.653-667
    • /
    • 1995
  • Post - operative wound infections have been a serious problem in nursing care in the operating room and appear to be strongly related to the infection occurring during the performance of operation. The purpose of this study is to identify patterns in duration of surgical hand scrub (SHS), to evaluate the method of SHS and to examine the rate of glove perforation. Subjects for this study include 244 doctors and 169 nurses working in the operative theatre of a hospital in Seoul area. Test samples and related data were collected from this medical facility between April 1, through 15, and July 1, through 5, 1995 by the author and a staff member working in the operating room. For the study, data on the SHS of doctors and nurses were obtained at the time of operation and multiple batches of surgical gloves worn by the operating doctors were collected after each operation. The duration of SHS was measured with a stop watch and the method of SHS was evaluated according to Scoring Hand Scrub Criteria (SHS Criteria) and expressed as SHS scores. For the analysis of the data, t-test was used to compare the differences in the duration and the SHS scores of doctors and nurses, and Pearson's correlation coefficient was used to examine the relationship between the SHS duration and the SHS scores. The results of the study are summarized as follows. 1) The mean time spent in each SHS was 167 seconds in nurses, and 127 seconds in doctors. The data comparing nurses and doctors indicated that there were significant differences in Our ation of SH S between these two groups (t=5.58, p=.000). 2) The mean time spent in the first SHS was 145 seconds and that in the End SHS, 135 seconds, and there was not a significant difference in the duration of the SHS between doctors and nurses (t=1.44, P=.156). 3) The mean time spent in the SHS by OS (Orthopaedic surgery) doctors was 162 seconds, 150 seconds by NS(Neurologic surgery), 121 seconds by GS(General surgery), 94 seconds by OPH(Opthalmology) and DS(Dental surgery), 82 seconds by URO(Urology), 78 seconds by PS(Plastic surgery) and 40 seconds by ENT(Ear, Nose & Throat) These also showed a significant difference in the duration of the SHS among the medical specialities (t=4.8, P=.0001). 4) The average SHS score of the nurses was 15.2, while that of doctors was 13.1. The statistical analysis showed that t-value was 3.66, p was. 000. This indicates that the nurses actually clean their hands more thoroughly than the doctors do. 5) The average SHS score of NS doctors was 15.5, 15.3 for doctors for OPH,14.3 for OS,12.7 for GS, 12.0 for DS, 11.7 for URO, 10.1 for PS, 7.5 for ENT. Comparison of the average SHS scores from 8 specialties showed that there was a significant differences in the patterns of the SHS (F=5.08, P=.000) among medical specialties. 6) It appears that the operating personnel scrub the palms and dorsum of their hand relatively well, however, less thorough the nails and fingers. 7) The more the operating personnel spend their time in hand scrubbing, the more correctly they clean their hands(r=.6427, P<.001). 8) The overall frequencies of perforation in all post-operative gloves tested was 38 out of 389 gloves (10.3%). The perforation rate for PS was 13%, 12.1% for GS,8.8% for 05, and 3.3% for NS.

  • PDF