• 제목/요약/키워드: F-wave

검색결과 615건 처리시간 0.024초

백회(百會)(GV20).신회(顖會)(GV22) 자침이 뇌파에 미치는 영향 (The Effects of Acupuncture at the GV20 and GV22 on the Electroencephalogram(EEG))

  • 이상훈;류연희;권오상;손인철
    • Korean Journal of Acupuncture
    • /
    • 제29권3호
    • /
    • pp.467-475
    • /
    • 2012
  • Objectives : The aim of this study was to examine the effects of Acupuncture at the GV20 and GV22 on normal human beings using power spectrum analysis. Methods : Electroencephalogram(EEG) power spectrum exhibits site-specific and state-related differences in various frequency bands. 8 channels Background Electroencephalogram (EEG) was carried out in 30 subjects(24 females and 4 males). Results : In ${\delta}$(theta) band, the power values decreased significantly at the 8-channel average value(p=0.03) and especially at T3(p=0.02), T4(p=0.001) and P3(p=0.03). In ${\alpha}$(alpha) band, the power values have no significant changes. In ${\beta}$(beta)band, the power values increased significantly at the 8-channel average value (p=0.02) and especially at T4(p=0.003), P3 (p= 0.03) and P4(0.02). In ${\beta}/{\delta}$(beta/theta) ratio, the value increased significantly at the 8-channel average value(p=0.002) and especially at Fp2(p=0.05), F4(p=0.007), T3(0.012), T4(0.005), P3 (0.007) and P4(0.03) Conclusions : Through this data, we conclude that acupuncture at the GV20 and GV22 on normal human beings could have possibility to awake the cerebral cortex by the functional mechanism.

압전소자를 이용한 볼트토크 및 크랙의 정량적평가에 관한 연구 (Quantitative Assessment of the Fastening Condition and the Crack Size with Using Piezoceramic(PZT) Sensors)

  • 홍동표;홍용;왕고평;김병진;김영문
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.603-606
    • /
    • 2006
  • We present a study on the development of a practical and quantitative technique for the assessment of the structural health condition with using piezoceramic(PZT) sensors. The electro-impedance-based technique with the PZT patches is very sensitive for evaluation of the incipient and small damage in a high frequency range, and however the commonly traditional modal analysis method is effective only for considerably larger damages in low frequency range. The paper presents the technique in detecting and characterizing real-time damage on the specimen that is an aluminum plate fastened with bolts and nuts by different torques and as well a plate with a crack. By using the special arrangement of the PZT sensors, the required longitudinal wave is generated through the specimen. A large number of experiments are conducted and the different conditions of the specimens, i.e. the location and extent of loosening bolts, and the plate with a crack are simulated. respectively. Since fixing and loosening the loosened bolt is controlled by a torque wrench, we can control exactly the experiment of the different torques. Compared with the simulated healthy condition, we can find whether or not there is a damage in the specimen with using an impedance analyzer with the PZT sensors. Several indices are discussed and used for assessing the different simulated damages. As for the location of bolt loosening, the RMSD is found to be the most appropriate index for numerical assessment and as well the RMSD shows strongly linear relationship for assessing the extent of the bolt loosening, and the frequency peak shift ${\Delta}F$ is used to assess the cracked plate. The possibility of repeatability of the pristine condition signatures is also presented and the appropriate frequency range and interval are uniquely selected through large numbers of experiments.

  • PDF

실시간 탄성초음파를 이용한 만성 뇌졸중 후 편마비 환자의 상지 강직에 대한 사암침 효과 연구 (Study of the Effects of Sa-am Acupuncture on Upper Limb Spasticity in Patients with Chronic Post-stroke Hemiparesis using Real-time Sonoelastography)

  • 백경민;권동락;박기영
    • 대한한방내과학회지
    • /
    • 제35권1호
    • /
    • pp.1-11
    • /
    • 2014
  • Objectives : To investigate the effects of Sa-am acupuncture on muscle architecture and elastic properties of the spastic elbow flexor and to evaluate the correlation between clinical findings and parameters of real-time sonoelastography (RTS) in patients with chronic post-stroke hemiparesis. Materials and Methods : Seven patients (five males, two females) with chronic post-stroke hemiparesis were included. Sa-am acupuncture of Ganseunggyeok (肝勝格: LU8 LR4 補, HT8 LR2 瀉) was applied to the unaffected side 3 times a week for 4 weeks. During each acupuncture treatment period, patients were requested to exercise their affected arm, and spasticity and functional recovery outcomes of the affected arm were evaluated before and after Sa-am acupuncture treatment. Clinical outcomes were assessed using motricity index (MI), modified Ashworth scale (MAS), Fugl-Meyer assessment scale (FMA) and modified Barthel index (MBI) for elbow flexor spasticity. RTS images indicate the relative hardness of the examined muscles ranged from red (hard) to purple (soft) for color-scale, and from black (hard) to white (soft) for hue scale. Color and hue histograms of the biceps brachii and brachialis were analyzed using Image J software, and median red, blue, and hue pixel intensity were obtained. Results : MI and FMA score significantly increased and MAS score significantly decreased (p<0.05). F-wave maximal amplitude of affected abductor pollicis brevis significantly decreased (p<0.05). Muscle thickness of affected brachialis significantly increased (p<0.05). Red and green pixel intensity of affected brachialis significantly decreased (p<0.05). Conclusions : Our study revealed that Sa-am acupuncture is effective as a useful and safe treatment for spasticity in chronic post-stroke hemiparesis.

식품수요(食品需要)의 연령계층별(年齡階層別) 특성분석(特性分析) (An Analysis on the Age Specific Characteristics in Korean Diet)

  • 이정환;조덕래
    • 한국식생활문화학회지
    • /
    • 제1권3호
    • /
    • pp.231-247
    • /
    • 1986
  • Age specific characteristics in Korean diet and their changes were analyzed with the demand model including the number of family members by age group as independent vasiables Urban household budget data, 773 household data in 1977 and 947 household data in 1983, was applied to the demand model. A series of F-test was carried out to set up the age groups by food item. The main results can be summarized as follows; 1. Food consumption patterns are remarkably different between 0-13 years old age generation and over 40 years old generation. The 0-13 years old generation reveals higher preference for milk, wheat product, fruit and milk and lower preference for rice and vegetable than any other age generation. This characteristics of the childhood diet has been formed In the generation born after 1970's and thus will be reserved as their generational characteristics. On the other hand, over 40 years old age group prefers rice and fish to fruit, milk and wheat product. Therefore we can conclude that over 40 years old age group maintains the traditional Korean diet pattern. 2. The preference for fish is low. in 20-30 years old age group than in any other age group and wheat product is Preferred highest in 6-13 years old age group of all age groups. Meanwhile the most remarkable change In food consumption pattern is shown in meats and vegetables. Namely in 30 40 years old age group the preference for meat has increased substantially and that vegetable has decreased to a great extent. 3. The declining per capita consumption of rice spreads like a wave to higher age. groups, but over 40 years old age group bas played an important role in reducing the decreasing rate of rice consumption. In order to restrain the declining rice consumption a special integrated food policy is required to induce rice consumption in less 30 years old generation.

  • PDF

음식물쓰레기 소멸제의 쓰레기 소멸특성에 관한 연구( I ) (A Study on the garbage decomposing Characteristics of the garbage-decomposing accelerant( I ))

  • 홍정희;안용근;정진도
    • 환경위생공학
    • /
    • 제18권1호
    • /
    • pp.58-67
    • /
    • 2003
  • The characteristics of the commercial garbage-decomposing accelerant, Raw Material of Pomia(RMP), Pomia and Vitabio. were analyzed. In HPLC pattern, Pomia and Vitabio showed main peak of about 30kDa in 280nm wave length. RMP, Pomia and Vitabio showed three, two and two peaks in 210nm. K and Na ion content of RMP were 2,620 and 1,590ppm, respectively, and their content were the largest one among others. Ca, Mg and Mn ion content of RMP were also the largest one, but Zn ion content was the least one. $Cl^{-}$, $F^{-}$ and $NO_3^{-}$ ion content of RMP were the largest one, especially $Cl^{-}$ content was 3,553ppm. pH values of RMP and Pomia were in neutral region, but Vitabio was 9.03. Dried residue content of RMP, Pomia and Vitabio were 1.4%, 0.55% and 0.4%, respectively. The number of general bacteria on PCA plate from RMP, Pomia and Vitabio were 2.2{\times}10^{6}cfu/ml,{\;}6.5{\times}10^{3}cfu/ml{\;}and{\;}1.1{\times}10^{3}cfu/ml$, respectively. The number of facultative anaerobes of RMP was $4.4{\;}{\times}{\;}10^{4}cfu/ml$, and it was biggest one. Lactobacilli and yeasts were found less than 10cfu/ml at best. The bacterium exists in RMP in high frequency was identified as Bacillus subtilis. Volatile sulfur compound amount of garbage samples treated with Pomia and Vitabio in concentration of 1/500 at $33^{\circ}C$ for 8 days were 1,273ppb and 1,902ppb, respectively, and control showed 3,015ppb. Volatile organic compound amount of the garbage samples treated were 68,312ppb, 124,317ppb and 263,954ppm, respectively. Diethylamine that known as malodor compound were 5,107ppb, 261ppb and 11,124ppb, respectively.

Ordering of manganese spins in photoconducting $Zn_{1-x}Mn_xTe$

  • Kajitani, T.;Kamiya, T.;Sato, K.;Shamoto, S.;Ono, Y.;Sato, T.;Oka, Y.
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 1998년도 PROCEEDINGS OF THE 14TH KACG TECHNICAL MEETING AND THE 5TH KOREA-JAPAN EMGS (ELECTRONIC MATERIALS GROWTH SYMPOSIUM)
    • /
    • pp.39-43
    • /
    • 1998
  • Single crystals of{{{{ { Zn}_{ 1-x} {Mn }_{x }{Te} }}}} with x=0.3-0.6 were prepared by the standard Bridgeman method. Diffuse neutron diffraction intensities due to the short range magnetic ordering is found in the vicinities of 1 1/2 0 reciprocal point and its equivalent point, indicating that the magnetic correlation of the clusters is the type III antiferromangetic one do the F-type Bravais class crystals, being identical with that of {{{{{ Cd}_{ 1-x} {Mn }_{x }Te }}}}. Neutron inelastic scattering measure-ment has been performed for {{{{{ Zn}_{ 0.6} { Mn}_{ 0.4}Te }}}} sample using the cold neutron spectrometer. AGNES. High resolution measurement with the energy resolution of {{{{ TRIANGLE E= +- .01meV}}}} was carried out in the temperature range from 10K to the ambient. Critical scattering, closely related with the spin glass transition, has been observed for the first time in this semimagnetic semi-conductor. The critical scattering is observed at temperatures in the vicinity of the spin glass transition temperature, 17K. The scattering is observed as a kind of quasielastic scattering in the reciprocal range where the elastic magnetic diffuse scattering has been observed, e.g., 11/20 reciprocal point, indicating the spin fluctuation has dynamic components in this material. Photoconductivity has been discovered below 150K in {{{{{ Zn}_{ 0.4} {Mn }_{0.6 } Te}}}}. The electric AC conductivity has been increased dramatically under the laser light with the wave lengths of {{{{ lambda =6328,5145 and4880 }}}}$\AA$ ,respectively. After the light was darkened, the conductivity was reduced to the original level after about 2000 seconds at 50K, being above the spin glass transition temperature. This phenomenon is the typical persistent photoconductivity; PPC which was similarly found in {{{{ { Zn}_{ 1-x} { Mn}_{x} Te}}}}.

  • PDF

Particle-in-cell simulation feasibility test for analysis of non-collective Thomson scattering as a diagnostic method in ITER

  • Zamenjani, F. Moradi;Asgarian, M. Ali;Mostajaboddavati, M.;Rasouli, C.
    • Nuclear Engineering and Technology
    • /
    • 제52권3호
    • /
    • pp.568-574
    • /
    • 2020
  • The feasibility of the particle-in-cell (PIC) method is assessed to simulate the non-collective phenomena like non-collective Thomson scattering (TS). The non-collective TS in the laser-plasma interaction, which is related to the single-particle behavior, is simulated through a 2D relativistic PIC code (XOOPIC). For this simulation, a non-collective TS is emitted from a 50-50 DT plasma with electron density and temperature of ne = 3.00 × 1013 cm-3 and Te = 1000 eV, typical for the edge plasma at ITER measured by ETS system, respectively. The wavelength, intensity, and FWHM of the laser applied in the ETS system are λi,0 = 1.064 × 10-4 cm, Ii = 2.24 × 1017 erg=s·㎠, and 12.00 ns, respectively. The electron density and temperature predicted by the PIC simulation, obtained from the TS scattered wave, are ne,TS = 2.91 × 1013 cm-3 and Te,TS = 1089 eV, respectively, which are in accordance with the input values of the simulated plasma. The obtained results indicate that the ambiguities rising due to the contradiction between the PIC statistical collective mechanism caused by the super-particle concept and the non-collective nature of TS are resolved. The ability and validity to use PIC method to study the non-collective regimes are verified.

Irradiation of Intense Characteristic X-rays from Weakly Ionized Linear Plasma

  • Sato, Eiichi;Hayasi, Yasuomi;Tanaka, Etsuro;Mori, Hidezo;Kawai, Toshiaki;Takayama, Kazuyoshi;Ido, Hideaki
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.396-399
    • /
    • 2002
  • Intense quasi-monochromatic x-ray irradiation from the linear plasma target is described. The plasma x-ray generator employs a high-voltage power supply, a low-impedance coaxial transmission line, a high-voltage condenser with a capacity of about 200 nF, a turbo-molecular pump, a thyristor pulse generator as a trigger device, and a flash x-ray tube. The high-voltage main condenser is charged up to 55 kV by the power supply, and the electric charges in the condenser are discharged to the tube after triggering the cathode electrode. The x-ray tube is of a demountable triode that is connected to the turbo molecular pump with a pressure of approximately 1 mPa. As electron flows from the cathode electrode are roughly converged to the molybdenum target by the electric field in the tube, the weakly ionized plasma, which consists of metal ions and electrons, forms by the target evaporating. In the present work, the peak tube voltage was almost equal to the initial charging voltage of the main condenser, and the peak current was about 20 kA with a charging voltage of 55 kV. When the charging voltage was increased, the linear plasma x-ray source grew, and the characteristic x-ray intensities of K-series lines increased. The quite sharp lines such as hard x-ray lasers were clearly observed. The quasi-monochromatic radiography was performed by a new film-less computed radiography system.

  • PDF

Far infrared를 이용한 생체정보 인터페이싱에 대한 연구 (Research of human body information interfacing with Far infrared and application to physical therapy)

  • 박래준;김재윤
    • The Journal of Korean Physical Therapy
    • /
    • 제13권3호
    • /
    • pp.509-527
    • /
    • 2001
  • The Sun's ray is composed of Infrared(49%), Visible light(40%) and Ultra violet(11%), however the ray getting to the earth is FIR(Far infrared; 60%), IR(Infrared; 20%), and UV(Ultra Violet; 20%). Human beings has utilized FIR already from time immemorial. Hershel found out Infrared for the first time. in the Industrial Revolution the Infrared and FIR had been begun to use making products. In these days, with contemporary science FIR would be begun to clear up the implication in the human body and organic compound. IR classified by wavelength three parts NlR, MIR, FIR. There is FIR which is radiated from healthy human body the wave length is 8-l4m. The human body is composed of proteins which get easily changed by a thermal factor (about 42 $^{\circ}$C over). FIR with low temperature can deeply penetrate on the human body composed things without troublesomes, since FIR has effectively operated on the human body at low temperature (35-40 $^{\circ}$C). When FlR penetrated on the human body. it would inhibit the abnormal genes and cells expression, and then information of DNA and RNA would be reexpressed for arranging DNA and RNA abnormal state. As FlR's receptors in the body, it could be presumed that N-glycosyl linkage of purine and deoxyribose, RNA splicing process, and Heat shock protein. To take the FIR which was a optimized wavewlength and strength, at first, we induced the characteristic algorithm and the computerized programing. Then we formed that the formular of optimized FIR with physical, mathematical logic and theory. especially, Plank, Kirchhoff, Wien, Stefan-Boltzmann's logic and law. In the long run, the formular was induced with integration mathematical, since we had to know the molecular wavelength. Based on the induced formular as above, we programmed the optimized FlR radiating computerized program. In this research, we designed the eletronic circuit f3r interfacing with human body to diagnosis and treatment with FIR sensor which radiated FIR wavelength optimized.

  • PDF

2-파라메타 모델에 의한 고주파 연소불안정 해석 (2-Parameter High Frequency Combustion Instability Model)

  • 조용호;윤웅섭
    • 한국추진공학회지
    • /
    • 제1권2호
    • /
    • pp.74-83
    • /
    • 1997
  • 본 연구에서는 원통형 연소실에서 발생하는 고주파 연소불안정을 연소응답함수와 n-$\tau$ 음향 불안정 해석방법을 사용하여 예측하였다. 열역학적 변수들과 속도는 시간 평균성분 및 변화성분으로 분리하여 선형으로 전개하였으며, 유동은 비회전류로 가정하여 속도 포텐샬 함수를 위한 지배방정식으로 수식화하였다. 연소응답의 계산에는 화염면 상, 하류에서의 연소실반응과 화염면에서의 연속조건이 적용되었다. 연소응답은 압력간섭계수 n과 감응시간지연 $\tau$로 변환되어 중립불안정한계를 결정하였다. LOX-RP1 추진제 조합의 원통형 연소실에서 연소압력 및 추진제 혼합비의 변화는 연소 음향반응과 중립불안정에 영향을 주지 않으나, 긴 거주시간에 의한 화염면 발생의 지연과 화염면 하류에서의 공간은 고주파 연소불안정의 발생에 강한 영향을 주는 것으로 예측되었다. 결과적으로 연소의 음향응답에는 추진제의 거주시간, 연소실 형상조건과 노즐에 의한 감쇠효과가 중요한 파라메터인 것으로 나타났다.

  • PDF