• Title/Summary/Keyword: F-wave

Search Result 611, Processing Time 0.032 seconds

F-Wave Analysis in Patients with Clinically Diagnosed Carpal Tunnel Syndrome (임상적으로 진단된 수근관증후군 환자에서 F파 분석)

  • Kim, Seong-Hee;Yoo, Bong-Goo;Kim, Kwangsoo;Yoo, Kyung-Moo
    • Annals of Clinical Neurophysiology
    • /
    • v.4 no.2
    • /
    • pp.108-113
    • /
    • 2002
  • Background and Objective : Carpal tunnel syndrome (CTS) is the most common mononeuropathy encountered in clinical practice. No single procedure or group of procedures has demonstrated adequate sensitivity. F-wave study in CTS is very rarely reported. To determine the diagnostic usefulness of new parameters of F-wave and comparative study of F-wave parameters of median and ulnar nerves in patients with CTS. Methods : F-wave responses of median and ulnar nerves were analyzed from 27 patients with clinically diagnosed CTS and 22 age and gender-matched normal control. Conventional F-wave parameters were studied. Also, the usefulness of new parameters such as mean and maximal ulnar-median F-wave latency differences, ulnar-median F-wave persistence and chronodispersion differences, median/ulnar F-wave amplitude ratio, and F-wave conduction velocity (FCV) using mean and maximal latency were assessed. Results : Compared with controls, median F-wave minimal, maximal and mean latencies, mean F-wave amplitude/M-wave amplitude, minimal, mean and maximal ulnar-median F-wave latency differences, and FCVs using minimal, maximal and mean latency were significant (P<0.05~0.001). Median F-wave minimal, maximal and mean latencies, mean ulnar-median F-wave latency difference, and FCVs using minimal, maximal and mean latency showed high sensitivity and specificity. Mean ulnar-median F-wave latency difference and FCVs using maximal and mean latency were new parameters. Conclusion : New F-wave parameter including mean ulnar- median F-wave latency difference and FCVs using maximal and mean latency may be a useful to assess the CTS. Also, median F-wave minimal, maximal and mean latencies, and FCV using minimal latency may be included in routine diagnostic tests in CTS.

  • PDF

Median and ulnar F-wave inversion as a supplementary criterion for diagnosis of carpal tunnel syndrome

  • Kim, Yoohwan;Jang, Jae-Hong;Cho, Charles S.;Kim, Byung-Jo
    • Annals of Clinical Neurophysiology
    • /
    • v.19 no.1
    • /
    • pp.13-19
    • /
    • 2017
  • Background: Median F-wave latencies are physiologically shorter than ulnar latencies, but they are often longer relative to ulnar latencies in carpal tunnel syndrome (CTS). This study aimed to investigate the value of absolute F-waves and relative latency changes compared to ulnar latencies in the diagnosis of CTS. Methods: F-wave latencies of median and ulnar nerves in 339 hands from 339 patients with CTS and 60 hands from 60 control subjects were investigated. Mean F-wave minimal latencies of median and ulnar nerves were compared between groups. Patients were further divided into subgroups based on Canterbury grading and then analyzed using F-wave latency differences (FWLD) and F-wave ratio (FWR). Results: Of 339 hands in the CTS group, 236 hands exhibited F-wave inversion based on the FWLD criterion and 277 hands had F-wave inversion based on the FWR criterion. F-wave inversion had a sensitivity of 81.7% using the FWR criterion to diagnose CTS. The mean FWLD and FWR were significantly greater in all patient subgroups compared to the control group (p < 0.001). In addition, mean FWLD and FWR showed significant correlations (r = -0.683 and r = 0.674, respectively, p < 0.001) with disease severity. Conclusions: F-wave studies are effective supplementary diagnostic tools comparing to other standard electrophysiologic criteria for screening patients with CTS.

The Research of Vibration Power Generation with Two Degree of Freedom Using Ocean Wave (파도를 이용한 2자유도 파력진동발전시스템에 대한 연구)

  • Han, Ki-Bong;Lee, Hyoung-Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.8
    • /
    • pp.1028-1034
    • /
    • 2011
  • This paper have been studied that ocean wave power vibration generation system with two D.O.F.(degree of freedom) consists of buoy and vibration generation system with two D.O.F. for using efficiency of ocean wave energy. It selected main frequencies ${\omega}_1$, ${\omega}_2$ in frequency with ocean wave and it fitted them to the natural frequencies of vibration system with two D.O.F. in the vibrational power generation system. Then each the relative velocity of between the winding coil and the permanent magnet is faster than the velocity of ocean wave up and down motion by resonance phenomenon. Also the ocean wave power generation with two D.O.F. obtained the more electric energy then the ocean wave power generation with one D.O.F. by coupling effect for two D.O.F. vibration system. Therefore ocean wave power vibration generation system with two degree of freedom that is proposed in this paper has merits which not only using more energy in the ocean wave but also obtaining more electronic energy.

Self Oscillating Double Conversion Mixer for low cost mm-wave system (밀리미터파 대역에서 저가격화 시스템을 위한 Self Oscillating Double Conversion Mixer)

  • Lee, Sang-Jin;Ahn, Dan;Lee, Mun-Kyo;Kwon, Hyuk-Ja;Baek, Tae-Jong;Jun, Byoung-Chul;Park, Hyun-Chang;Rhee, Jin-Koo
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.491-492
    • /
    • 2006
  • The MMIC (Microwave Monolithic Integrated Circuit) self oscillating double conversion mixer was designed and fabricated for the V-band transmitter applications. The MMIC self oscillating double conversion mixer which dose not need external local oscillator was designed using GaAs PHEMT technology. The first self oscillating mixer use PHEMT technology. The first self oscillating mixer use PHEMT for $f_{LO}$ signal generation and $f_{IF}$ signal is applied at gate port and $f_{RF1}$ signal is generated at a drain port of first stage. The second gate mixer use PHEMT for $f_{LO}$ signal and $f_{RF1}$ signal is applied at gate port and $f_{RF2}$ signal is output at a drain port of second stage.

  • PDF

The Effects of EEG Power and Coherence on Cognitive Function in Normal Elderly, Non-Demented Elderly With Mild Cognitive Impairment, and Demented Elderly During Working Cognition Task

  • Han, Dong-Wook
    • Physical Therapy Korea
    • /
    • v.15 no.4
    • /
    • pp.70-79
    • /
    • 2008
  • The purpose of this study was to find out the effects of electroencephalograph (EEG) power and coherence on cognitive function in normal elderly, non-demented elderly with mild cognitive impairment, and demented elderly during working cognition tasks. Forty elderly women (19 demented elderly, 10 non-demented elderly with mild cognitive impairment, 11 norma1 elderly) participated in this study, All subjects performed working cognition tasks with Raven's CPM while EEG signal was recorded, EEGs were measured continuously at rest and during the working cognition task. EEG power and coherence was computed over 21 channels: right and left frontal, central, parietal, temporal and occipital region. We found that there were more correct answers among normal elderly women than in other groups Owing the working cognition task, ${\Theta}$ wave at Fp1, Fp2 and F8, a wave at Fp2, ${\beta}$ wave at Fp1, Fp2. F4 and F8 of the frontal region was increased significantly in the demented elderly group. On the other hand. ${\Theta}$ wave at Fp1, Fp2 and F7, ${\beta}$ wave at Fp1, Fp2, F3 and F7 of the frontal region was increased significantly in the group of non-demented elderly with mild cognitive impairment. In contrast. in the normal elderly group, all of the ${\Theta}$ wave and ${\beta}$ wave at Fp1, Fp2, F3, F4, F7 and F8 of the frontal region (except ${\beta}$ wave at F3) was increased significantly, These results suggest that the nerves in prefrontal and right hemisphere regions were most active in the demented elderly group during problem solving, and the nerves in the prefrontal and left hemisphere lobe were most active in the group of non-demented elderly with mild cognitive impairment. In contrast, me majority of nerves in the frontal region were active in the normal elderly group.

  • PDF

Airside Performance of Fin-and-Tube Heat Exchangers Having Round Wave Fins (둥근 웨이브 핀-관 열교환기의 공기 측 전열 성능)

  • Kim, Nae-Hyun
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.105-116
    • /
    • 2015
  • In this study, airside performance of round fin-and-tube heat exchangers are compared with that of the herringbone wave fin-and-tube heat exchangers with an aim to investigate the effect of fin shape on thermal performance. Results show that j factors of the round wave fin are 1.2~22% larger than those of herringbone wave fin. The f factors of the round wave fin are -1.0~29% smaller than those of herringbone wave fin for 1 or 2 row configuration. For 3 row configuration, f factors of the round wave fin are 8.3~23% larger. The reason may be attributed to the reduced recirculation zone in the valley of the fin for round wave fin as compared with that of the herringbone wave fin. For round wave fin, the effect of fin pitch on j and f factor is not significant. In addition, j factors decrease as the number of tube row increases. On the other hand, f factors are independent of the number of tube row. A new correlation was developed based on the present data.

Fabrication of holographic zone plate using dichromated gelatin hologram (Dichromated Gelatin 박막을 이용한 홀로그래픽 Zone Plate 제작 및 해석)

  • 임용석;이영락;곽종훈;최옥식
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.1
    • /
    • pp.19-25
    • /
    • 1997
  • Holographic zone plate (HZP) is fabricated by interfering a plane wave and a spherical wave in a dichromated gelatin (DCG) film obtained from Agfa 8E75HD plates. We have developed a simple theory for HZP considering optical nonlinearity of DCG material. Analysis of our theory for HZP shows that it has infinite focal points at distances f,f/2, f/3,,…. In experiment, we observed the corresponding focal points of up to f/6 when illuminating HZP by a plane wave. It is also shown that the beam profile around the first focal point measured by using a knife-edge scanning method has a Gaussian shape.

  • PDF

Clinical importance of F-waves as a prognostic factor in Guillain-Barré syndrome in children

  • Lee, Eung-Bin;Lee, Yun Young;Lee, Jae Min;Son, Su Min;Hwang, Su-Kyeong;Kwon, Soonhak;Kim, Sae Yoon
    • Clinical and Experimental Pediatrics
    • /
    • v.59 no.6
    • /
    • pp.271-275
    • /
    • 2016
  • Purpose: A limited number of studies have examined the link between F-wave abnormalities and clinical presentation in pediatric Guillain-$Barr{\acute{e}}$ syndrome (GBS). Therefore, this study examined the importance of F-wave abnormalities as a prognostic factor in pediatric GBS patients. Methods: The records and electrodiagnostic studies (EDS) of 70 GBS patients were retrospectively evaluated, and divided into 2 groups according to the results of EDS. Group A (n=33) presented with F-wave abnormalities, and group B (n=26) exhibited normal findings. We compared laboratory reports, clinical features, response to treatment, and prognosis between the 2 groups. Results: Motor weakness was the most frequently observed symptom for either group. Clinically, the incidence of fever and upper respiratory symptoms differed between the 2 groups, while the prevalence of abnormal deep tendon reflex (DTR) was significantly higher in group A than B (P<0.05). Patients diagnosed with GBS had received intravenous immunoglobulin treatment: 94% in group A and 58% in group B. Furthermore, significantly greater numbers of patients in group A showed H-reflex abnormalities and poor prognosis compared with group B (P<0.05). Conclusion: This study demonstrated that F-waves are a clinically important prognostic factor in GBS. F-wave abnormalities were associated with abnormal DTR and poor prognosis in patients. Limited studies have examined the link between F-wave abnormalities and clinical results; therefore, further randomized controlled studies are needed to confirm the clinical characteristics and efficacy of treatments.

Peak mooring forces in the horizontal interlaced multi-layered moored floating pipe breakwater

  • Mane, Vishwanath;Rajappa, Sacchi;Rao, Subba;Vittal, Hegde A.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.3 no.2
    • /
    • pp.150-158
    • /
    • 2011
  • Present study aims to investigate the influence of relative breakwater width W/L (W=width of breakwater, L=wavelength), wave steepness $H_i/gT^2$ (Hi=incident wave height, T=wave period) and relative wave height d/W (d=water depth) on forces in the moorings of horizontal interlaced multi-layered moored floating pipe breakwater (HIMMFPB) model. Studies were conducted on scaled down physical models having three layers of Poly Vinyl Chloride (PVC) pipes, wave steepness $H_i/gT^2$ varying from 0.063 to 0.849, relative width W/L varying from 0.4 to 2.65 and relative spacing S/D=2 (S=horizontal centre-to-centre spacing of pipes, D=diameter of pipes). Peak mooring forces were also measured and data collected is analyzed by plotting non-dimensional graphs depicting variation of $f_s/{\gamma}W^2$ ($f_s$=Sea side Mooring force, ${\gamma}$=specific weight of water) & $f_l/{\gamma}W^2$ ($f_l$=Lee side Mooring force) with $H_i/gT^2$ for d/W varying from 0.082 to 0.276 and also variation of $f_s/{\gamma}W^2$ and $f_l/{\gamma}W^2$ with W/L for $H_i$/d varying from 0.06 to 0.400.

Millimeter-wave Dielectric Ceramics of Alumina and Forsterite with High Quality factor and Low Dielectric Constant

  • Ohasto, Hitoshi;Tsunooka, Tsutomu;Ando, Minato;Ohishi, Yoshihiro;Miyauchi, Yasuharu;Kakimoto, Ken ichi
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.4
    • /
    • pp.350-353
    • /
    • 2003
  • Millimeter-wave dielectric ceramics have been used like applications for ultrahigh speed wireless LAN because it reduces the resources of electromagnetic wave, and Intelligent Transport System (ITS) because of straight propagation wave. For millimeterwave, the dielectric ceramics with high quality factor (Q$.$f), low dielectric constant($\varepsilon$), and nearly zero temperature coefficient of resonant frequency ($\tau$) are needed. No microwave dielectric ceramics with these three properties exist except Ba(Mg$\_$1/3/Ta/sub1/3/)O$_3$ (BMT), which has a little high s: In this paper, alumina (Al$_2$O$_3$) and fosterite (Mg$_2$SiO$_4$), candidates for millimeter-wave applications, were studied with an objective to get high q$.$f and nearly zero $\tau$$\_$f/ For alumina ceramics, q$.$f more than 680,000 GHz was obtained but it was difficult to obtain nearly zero Qf. On the other hand, for forsterite ceramics, q$.$f was achieved from 10,000 GHz of commercial for sterite to 240,000 GHz of highly purified MgO and SiO$_2$ raw materials, and $\tau$$\_$f/ was reduced a few by adding TiO$_2$ with high positive $\tau$$\_$f/.