• Title/Summary/Keyword: F-Measure

Search Result 1,394, Processing Time 0.025 seconds

Collimation testing of a white light beam and measurement of chromatic aberration of a lens by using vernier Moire fringe patterns (버니어 무아레 무늬를 이용한 백색광의 시준 검사 및 렌즈의 색수차 측정)

  • 송종섭
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.4
    • /
    • pp.232-238
    • /
    • 2000
  • The new collimation testing technique of a white light beam using vernier Moire fringes of two line or circular gratings with different pitches is presented. We can visually measure the defocusing ($\Deltaf$), the divergence angle ($\theta$), and the longitudinal chromatic aberration $(L_{ch})$ of a collimating lens by using the technique. For example, we obtained $\Deltaf$= 21.9 mm and $\theta=0.0038^{\circ}$ for a testing lens with the focallengthf = 120.0 mm and F-number of F/2.4. The longitudinal chromatic aberration $L_{ch}$ of another testing lens withf = 65.0 mm, F/1.6, and the Abbe number V = 64.1 for the incident wavelengths of $\lambda_1=480 nm and \lambda_2=640 nm$ is easily measured by same technique. It is found that the measured value $L_{ch}=1.59mm(\pm0.01mm)$ is well agreed with $L_{ch}=1.58mm(\pm0.01mm)$ obtained by the autofocus method.

  • PDF

Correlations among Sleep Quality, Depression and Satisfaction with Enrolled in the Nursing College Students (간호대 재학생의 수면의 질, 우울, 학과만족도 간의 상관관계 연구)

  • Jeong, Gyeongsun;Park, Euijeung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.4 no.3
    • /
    • pp.93-100
    • /
    • 2016
  • Purpose : The purpose of this research is to measure the correlations among sleep quality, depression and department satisfaction in the students enrolled in the nursing college located in the B city. Method : 268 students enrolled in the nursing college located in the B city participated in this research from the 1st May 2016 to the 31st May 2016. SPSS 18.0 was applied to the collected data to calculate the frequency, percentage, average and standard deviation. In addition, t-test, ANOVA, Scheffe test and Pearson correlation coefficient were used for the analysis. Result : The result of the average sleep quality, depression and department satisfaction in the nursing college students were measured to be $2.41{\pm}0.57$, $3.59{\pm}0.50$ and $3.56{\pm}0.57$ respectively. The sleep quality based on the general characteristics indicated a significant difference when applied to the health status(F=4.46, p=.012). The depression indicated a significant difference when applied to the living with parents(t=-2.18, p=.030) and relationship with friends(F=8.62, p=.000). The department satisfaction indicated a significant difference when applied to the grade(F=3.45, p=.017), personality(F=3.46, p=.033), and reason for applying for their department(F=2.49, p=.044). As a result of analyzing the correlations among sleep quality, depression and department satisfaction in the nursing college students, the sleep quality indicated a negative correlation with the depression(r=-.528, p=.000) and a positive correlation with the department satisfaction(r=.144, p=.018). The depression indicated a negative correlation with the department satisfaction(r=.119, p=.051). Conclusion : It is necessary to conduct a replication research by increasing the number of the research subjects. In addition, it is necessary to conduct a systematic research on the factors influential on sleep quality, depression and department satisfaction in order to develop a program capable of enhancing the sleep quality and decreasing the depression.

Noise Characteristics of Readout Electronics for 64-Channel DROS Magnetocardiography System (64채널 DROS 심자도 시스템을 위한 검출 회로의 잡음 특성)

  • Kim J. M.;Kim K. D.;Lee Y. H.;Yu K. K.;Kim K. W.;Kwon H. C.;Sasada Ichiro
    • Progress in Superconductivity
    • /
    • v.7 no.1
    • /
    • pp.46-51
    • /
    • 2005
  • We have developed control electronics to operate flux-locked loop (FLL), and analog signal filters to process FLL outputs for 64-channel Double Relaxation Oscillation SQUID (DROS) magnetocardiography (MCG) system. Control electronics consisting of a preamplifier, an integrator, and a feedback, is compact and low-cost due to larger swing voltage and flux-to-voltage transfer coefficients of DROS than those of dc SQUIDs. Analog signal filter (ASF) serially chained with a high-pass filter having a cut-off frequency of 0.1 Hz, an amplifier having a gain of 100, a low-pass filter of 100 Hz, and a notch filter of 60 Hz makes FLL output suitable for MCG. The noise of a preamplifier in FLL control electronics is $7\;nV/{\surd}\;Hz$ at 1 Hz, $1.5\;nV/{\surd}\;Hz$ at 100 Hz that contributes $6\;fT/{\surd}\;Hz$ at 1 Hz, $1.3\;fT/{\surd}\;Hz$ at 100 Hz in readout electronics, and the noise of ASF electronics is $150\;{\mu}V/{\surd}\;Hz$ equivalent to $0.13\;fT/{\surd}\;Hz$ within the range of $1{\sim}100\;Hz$. When DROSs are connected to readout electronics inside a magnetically shielded room, the noise of 64-channel DROS system is $10\;fT/{\surd}\;Hz$ at 1 Hz, $5\;fT/{\surd}\;Hz$ at 100 Hz on the average, low enough to measure human MCG.

  • PDF

An Analysis of Farm household Economy by Family Life Cycle (가정생활주기에 따른 농가경제 분석)

  • 최현자;최은숙
    • Journal of Families and Better Life
    • /
    • v.4 no.2
    • /
    • pp.35-51
    • /
    • 1986
  • The purpose of this study is to establish family life cycle of farm and to analyze changes of economic conditions-income, consumption expenditures, savings, assets, and debts-in farm household according to the family life cycle. Income, consumption expenditures, savings, assets, and debts functions are also estimated by age of household head. The data of Farm Household Economy Survey which was conducted in 1983 by Ministry of Agriculture and Fisheries is used in this study. Among total data of 2000, 1603 are analyzed for mean, percentage, and regression using CRISP Program at Office of Rural Development. The results of study can be summarized as follows; 1) Eight stages of family life cycle of farm are established according to the growth of the first child. They are: Establishment stage, Child bearing and preschool stage, Elementary school stage, Middle and high school stage, College and vocational adjustment stage, Period of children's marriage, Re-adjustment stage, and isorganizing stage. 2) The economic conditions of farm household are significantly fluctuated by family life cycle. Among the eight stages, stage Ⅱ is considered relatively comfortable living period and stage Ⅲ, Ⅳ are the most difficult periods of farm household economy. 3) The estimated functions of income, consumption expenditures, savings, assets, and debts by age of household head are as follows; Y(income) = 2, 354, 832+98,456T-1,036T2(F=11.746) C(consumption expenditures) = 81,876+154,976T-1,552T2 (F=37.272) S(savings) = 2,272,956+56,511T+516T2(F=4.262) D(debts) = 903,929+28,300T-438T2(F=3.339) A(assets) = 200,816+1,213,336T-12,930T2(F=21.069) To carry on a reasonable farm household management, a suitable measure to cope with the desire of family and the economic conditions of farm household should be prepared.

  • PDF

Effect of Different Raising Techniques on In vivo Performance and Carcass and Meat Traits of Ischia Grey Rabbit

  • Bovera, Fulvia;Di Meo, Carmelo;Nizza, Sandra;Piccolo, Giovanni;Nizza, Antonino
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.9
    • /
    • pp.1361-1366
    • /
    • 2008
  • One-hundred and twenty Ischia grey rabbits, traditionally raised in pits, were equally divided after weaning (32 days) into three groups: group C, housed in cages (4 rabbits/cage) and fed a commercial concentrate; group GF, housed as C group and fed grasses collected on the island and crushed faba beans supplemented with an appropriate mineral vitamin mix; group P, housed in pits (8 rabbits/pit) and fed as GF group. Feed intake was recorded daily and live weight monthly up to slaughter (92 days). At slaughter, 10 rabbits per group were used to measure carcass and meat traits. The carcasses were weighed and measured according to the standard procedures and meat samples from the Longissimus dorsi and left hind leg were analysed for water holding capacity and chemical composition, respectively. During the entire trial, group C consumed significantly (p<0.01) a higher quantity of feed than the other groups (126.1 vs. 63.4 and 66.5 g/d, resp. for groups C, GF and P) and at slaughter showed a significantly (p<0.01) higher body weight (2,529.7 vs. 1,324.4 and 1,375.4 g, resp. for groups C, GF and P). Significant differences (p<0.01) were found also for dressing out percentage (68.6 vs. 66.6 and 66.9%, resp. for groups C, GF and P) and for meat chemical composition, in particular lipid percentage (4.13 vs. 1.84 and 1.93%, resp., for groups C, GF and P, p<0.01) and moisture (73.7 vs. 76.4 and 76.3%, resp. for groups C, GF and P, p<0.01). The results suggest the opportunity to obtain heavier animals raised in the pits if their diets were integrated with commercial feed.

The Study on the Development of Self Efficacy Expectation Promoting Program and It's Effect for Breast Self Examination (유방자가검진을 위한 효능기대 증진 프로그램의 개발 및 효과)

  • Jung, Myung-Ok;Tae, Young-Sook
    • Asian Oncology Nursing
    • /
    • v.2 no.1
    • /
    • pp.50-60
    • /
    • 2002
  • Breast self-exam is easiest, safe and cost effective to be recommended as an important method for early detection of breast cancer. This experimental research with non-equal control design was to develop the efficacy expectation program for breast self-exam based on Bandura's self-efficacy information source. The study objects selected from two local churches in Busan. Twenty from S church were selected as a study group, twenty from D church as a control group. Efficacy expectation promoting program was based on Bandura's efficacy promoting source and was two hour lecture including slide, video tape, demonstration, pamphlet. After this, there were individual interviews with them and consultations through telephone f or verbal persuasion on the weekly basis between the first week and the fifth week. The effect from the experiment were measured on the first week after education and on the fifth week. Data from control group was collected during the period from Jan 11, 2 001 to Feb 15, 2001 and data from study group was collected during the period from Jan 12, 2001 to Feb 16, 2001. Measurement instrument for this study was developed by the author with the advice of specialist in order to measure self-efficacy and breast self-exam practice. Data analysis was done by using SPSS/10.0 PC program $with^2-$ test. t-test and ANCOVA. Proved results for hypothesis were as follows. 1) It was supported that "Study group educated by efficacy expectation promoting program has higher score in change rat e of self-efficacy than control group." (1 week after education F=18.395, p=.000 5 weeks after education F=28.972, p=.000) 2) It was supported that "Study group educated by efficacy expectation promoting program has higher score in change rate of exam practice than control group." (1 week after education F=37.984, p=.000 5 weeks after education F=28.972, p=.000) In conclusion, efficacy expectation promoting program for breast self-exam developed by this study may increase s elf-efficacy and breast self-exam practice.

  • PDF

The Effect of Electroacupuncture at the PC6(Naegwan) and TE5 (Oegwan) on the EEG (내관, 외관 전침 자극이 뇌파변화에 미치는 영향)

  • Yim, Jin-Teck;Kim, Su-Hyun;Lee, Sang-Ryong
    • Journal of Pharmacopuncture
    • /
    • v.6 no.3
    • /
    • pp.91-106
    • /
    • 2003
  • Objectives : The aim of this study was to examine the effects of electroacupuncture(EA) at the PC6(Naegwan) and the TE5 (Oegwan) on nounal humans using power spectral analysis. Methods : EEG power spectrum exhibit site-specific and state-related differences in specific frequency bands. In this study, power spectrum was used as a measure of complexity. 30 channel EEG study was carried out in 30 subjects(30 males ; age=23.7 years). Results : In ${\alpha}$(alpha) band, the power values at F7 channels(p<0.05) during the PC6-acupoint treatment were significantly were decreased. In ${\beta}$(beta) band, the power values at Fp1, Fz, TT1, T5, P3, P4, Po1, P02, O1, Oz, O2 channels(p<0.05) during the non-acupoint treatment and at Fp1, F4, F8 channels(p<0.05) during the TE5-acupoint treatment significantly were increased. In ${\theta}$(theta) band, the power values at Fp1 channels(p<0.05) during the non-acupoint treatment and at Oz channels(p<0.05) the TE5-acupoint treatment significantly were increased. but, the power values at F7 channels(p<0.05) during the non-acupoint treatment were significantly were decreased. In ${\delta}$(delta) band, the power values at TCP1, TCP2, CP1, T5 channels(p<0.05) during PC6-acupoint treatment were increased and the power values at F7, TT2 channels(p<0.05) during non-acupoint treatment were increased. but, the power values at the TE5-acupoint treatment significantly was decreased than the before-acupuncture treatment.

A novel retentive type of dental implant prosthesis: marginal fitness of the cementless double crown type implant prosthesis evaluated by bacterial penetration and viability

  • Hong, Seoung-Jin;Kwon, Kung-Rock;Jang, Eun-Young;Moon, Ji-Hoi
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.4
    • /
    • pp.233-238
    • /
    • 2020
  • PURPOSE. This study aims to compare the marginal fitness of two types of implant-supported fixed dental prosthesis, i.e., cementless fixation (CL.F) system and cement-retained type. MATERIALS AND METHODS. In each group, ten specimens were assessed. Each specimen comprised implant lab analog, titanium abutment fabricated with a 2-degree tapered axial wall, and zirconia crown. The crown of the CL.F system was retained by frictional force between abutment and relined composite resin. In the cement-retained type, zinc oxide eugenol cement was used to set crown and abutment. All specimens were sterilized with ethylene oxide, immersed in Prevotella intermedia culture in a 50 mL tube, and incubated with rotation. After 48 h, the specimens were washed thoroughly before separating the crown and abutment. The bacteria that penetrated into the crown-abutment interface were collected by washing with 500 µL of sterile saline. The bacterial cell number was quantified using the agar plate count technique. The BacTiter-Glo Microbial Cell Viability Assay Kit was used to measure bacterial adenosine triphosphate (ATP)-bioluminescence, which reflects the bacterial viability. The t-test was performed, and the significance level was set at 5%. RESULTS. The number of penetrating bacterial cells assessed by colony-forming units was approximately 33% lower in the CL.F system than in the cement-retained type (P<.05). ATP-bioluminescence was approximately 41% lower in the CL.F system than in the cement-retained type (P<.05). CONCLUSION. The CL.F system is more resistant to bacterial penetration into the abutment-crown interface than the cement-retained type, thereby indicating a precise marginal fit.

Changes of Nurse's Image Perceived by Nursing Student as every Clinical Experience (임상실습시기별 간호학생이 지각하는 간호사의 이미지 변화)

  • Kim, Won-Ock;Kang, Hyun-Sook
    • Journal of East-West Nursing Research
    • /
    • v.10 no.1
    • /
    • pp.68-74
    • /
    • 2004
  • Purpose: This study aims to identify changing image of nurse before and after the first clinical experience, and before graduate. Method: The subjects were 69 nursing students. All of them had their first clinical experience for 1 week during sophomore year. The Nurse's Image was measured before and after the 1st clinical experience, and before graduation. Collected data were analyzed by using repeated measure ANOVA and pair wise comparison method. Results: 1. The mean score for the Nurse's Image overall held by after 1st clinical experience($3.78{\pm}.38$) was more positive than those held by before graduation($3.50{\pm}.49$) and before 1st clinical experience($3.35{\pm}.36$). 2. For the four subscales (F=25.673 p= .000), the mean score of traditional(F=10.394 P= .000), Social(F=11.673 P= .000), Professional(F=17.341 P= .000) and personal Image(F=19.463 P= .000) were more positive than before graduation and before 1st clinical experience. Conclusion: Summarizing, after the nursing students had their 1st clinical training, the nurse's image perceived by them was positively improved compared to before the training. However, by the time of graduation the improved nurse's image was declined back. Therefore it is necessary to develop proper out-to field training program that will help to maintain and furthermore improve nurse's image.

  • PDF

Upgrade of Neutron Energy Spectrometer with Single Multilayer Bonner Sphere Using Onion-like Structure

  • Mizukoshi, Tomoaki;Watanabe, Kenichi;Yamazaki, Atsushi;Uritan, Akira;Iguchi, Tetsuo;Ogata, Tomohiro;Muramatsu, Takashi
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.185-190
    • /
    • 2016
  • Background: In order to measure neutron energy spectra, the conventional Bonner Sphere Spectrometers (BSS) are widely used. In this spectrometer, several measurements with different size Bonner spheres are required. Operators should, therefore, place these spheres in several times to a measurement point where radiation dose might be relatively high. In order to reduce this effort, novel neutron energy spectrometer using an onion-like single Bonner sphere was proposed in our group. This Bonner sphere has multiple sensitive spherical shell layers in the single sphere. In this spectrometer, a band-shaped thermal neutron detection medium, which consists of a LiF-ZnS mixed powder scintillator sheet and a wavelength-shifting (WLS) fiber readout, was looped to each sphere at equal angular intervals. Amount of LiF neutron converter is reduced near polar region, where the band-shaped detectors are concentrated, in order to uniform the directional sensitivity. The LiF-ZnS mixed powder has an advantage of extremely high light yield. However, since it is opaque, scintillation photons cannot be collect uniformly. This type of detector shows no characteristic shape in the pulse height spectrum. Subsequently, it is difficult to set the pulse height discrimination level. This issue causes sensitivity fluctuation due to gain instability of photodetectors and/or electric modules. Materials and Methods: In order to solve this problem, we propose to replace the LiF-ZnS mixed powder into a flexible and Transparent RUbber SheeT type $LiCaAlF_6$ (TRUST LiCAF) scintillator. TRUST LiCAF scintillator can show a peak shape corresponding to neutron absorption events in the pulse height spectrum. Results and Discussion: We fabricated the prototype detector with five sensitive layers using TRUST LiCAF scintillator and conducted basic experiments to evaluate the directional uniformity of the sensitivity. Conclusion: The fabricated detector shows excellent directional uniformity of the neutron sensitivity.