• Title/Summary/Keyword: F-Measure

Search Result 1,394, Processing Time 0.023 seconds

Development of A Fractionated Stereotactic Radiotherapy System (분할 정위방사선 치료 시스템 개발 연구)

  • 이동한;지영훈;이동훈;조철구;김미숙;유형준;류성렬
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2002
  • We invented the newly developed Fractionated Stereotactic Radiotherapy(F.S.R.T) system using combined techniques of couch mounting and pedestal mounting system. Head fixation frame consists of a milled alluminium alloy(duralumin) and is placed to the couch. This frame immobilized patient head using the dental bite, 3.2 mm frontal and occipital thermoplastic mask. To evaluate the coordinate of target isocenter, Brown-Revert-Walls C.T localizer can be attached to this frame. And also, we developed the frame mounting system by developing the modification of pedestal mounting system. This system is fixed to couch floor and can be used to evaluate the isocenteric accuracy of gantry, couch and collimator in Q.A procedure. In order to measure the relocation accuracy, the acrylic phantom and the accurate pointers have been made. The repositioning of the targets in the phantom were estimated by comparing C.T coordinates and E.C.L portal films taken with anterior-posterior and right-left direction. From the results of experiments, the average distance errors between the target isocenter and its mean position were 0.71$\pm$0.19 for lateral, 0.45$\pm$0.15 for inferior-superior, 0.63$\pm$0.18 for anterior-posterior. And the maximum distance error was less than 1.3 mm. The new head fixation frame and frame mounting system were non-invasive, accurately relocatable, easy to use, very light and well tolerable by the results of phantom tests. The major advantage of using this frame mounting system is complete access to any point in the Patients cranium especially posterior direction

  • PDF

The Influence of Health Literacy and Social-Support on Medication Adherence in Eldery with Chronic Disease (만성질환노인의 건강정보이해능력, 사회적지지가 약물복용이행에 미치는 영향)

  • Jeong, Hyun-Ju;Bae, Jeong-Hee
    • Journal of Digital Convergence
    • /
    • v.16 no.7
    • /
    • pp.419-428
    • /
    • 2018
  • Purpose: The study was done to investigate the correlation among health literacy, social support and medication adherence in elderly with chronic diseases. Method: Participants were 100 patients with chronic diseases in two small hospitals in J do H. A structured questionnaires was used to measure the study variables from July 14, 2017 to August 14, 2017. Data was analyzed using descriptive statistics, t-test, ANOVA, Spearman correlation coefficient, and Multiple regression by SPSS/WIN 18.0 program. Result: Medication adherence and health literacy were positively correlated(r=.398, p<.001), Medication adherence and social support were positively correlated (r=.453, p<.001) and health literacy and social support were positively correlated(r=.731, p<.001). The factors influencing on medication adherance are Experience of adverse drug effect. The explanation is that medication adherence is total 25.9%(F=3.91, p<.001). Conclusion: Thus this suggests that in order to enhance medication adherence of the elderly with chronic diseases, educational programs are needed for offering customized medical information considering unique characteristics of the area and objects.

The remineralization effect of topical fluoride agents using confocal laser scanning microscope on artificial enamel caries aspects of convergence observation (공초점 레이저 주사 현미경을 이용한 우치 인공우식법랑질에서 불소도포 전·후의 재광화 효과에 대한 융합적 관찰)

  • Lee, Min-Sun;Kim, Hyo-Jin
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.6
    • /
    • pp.139-145
    • /
    • 2017
  • The aim of this study was to measure the remineralization effect of APF gel and fluride varnish on artificial enamel caries using CLSM in vitro. The samples were divided into 3 groups: control, 1.23% APF gel, 5% NaF varnish. The specimen surfaces were observed by CLSM and measured average fluorescence of the lesion(AFL). The results were analyzed using one-way ANOVA and Pearson's correlation analysis at a significance level off 0.05(PSWA 18.0, SPSS Inc., USA). There were significant differences between AFL at baseline and 1 day after fluoride application(p<0.05) but there are no significant differences between ${\Delta}$ AFL of all groups (p=0.222). Result of Pearson's correlation analysis, there are no significant correlation between VHN and AFL, but there were significant correlation between AFL at baseline and 1 day after fluoride application(r=0.811, p<0.001). Although AFL decreased after fluoride application, but there was no difference between the groups. In the future, it is necessary to test the oral environment model or in situ experiment supplemented the limitations of this study.

Reduction of the residual stress of various oxide films for MEMS structure fabrication (MEMS 공정을 위한 여러 종류의 산화막의 잔류응력 제거 공정)

  • Yi, Sang-Woo;Kim, Sung-Un;Lee, Sang-Woo;Kim, Jong-Pal;Park, Sang-Jun;Lee, Sang-Chul;Cho, Dong-Il
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.265-273
    • /
    • 1999
  • Various oxide films are commonly used as a sacrificial layer or etch mask in the fabrication of microelectromechanical systems (MEMS). Large residual strain of these oxide films causes the wafer to bow, which can have detrimental effects on photolithography and other ensuing processes. This paper investigates the residual strain of tetraethoxysilane (TEOS), low temperature oxide (LTO), 7 wt% and 10 wt% phosphosilicate glass (PSG). Euler beams and a bent-beam strain sensor are used to measure the residual strain. A poly silicon layer is used as the sacrificial layer, which is selectively etched away by $XeF_2$. First, the residual strain of as-deposited films is measured, which is quite large. The residual strain of the films is also measured after annealing them not only at $500^{\circ}C$, $600^{\circ}C$, $700^{\circ}$ and $800^{\circ}C$ in $N_2$ environment for 1 hour but also at the conditions for depositing a $2\;{\mu}m$ thick polysilicon at $585^{\circ}C$ and $625^{\circ}C$. Our results show that the 7 wt% PSG is best suited as the sacrificial layer for $2\;{\mu}$ thick polysilicon processes.

  • PDF

Study on frequency response of implantable microphone and vibrating transducer for the gain compensation of implantable middle ear hearing aid (이식형 마이크로폰과 진동체를 갖는 인공중이의 이득 보상을 위한 주파수 특성 고찰)

  • Jung, Eui-Sung;Seong, Ki-Woong;Lim, Hyung-Gyu;Lee, Jang-Woo;Kim, Dong-Wook;Lee, Jyung-Hyun;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.361-368
    • /
    • 2010
  • ACROSS device, which is composed of an implantable microphone, a signal processor, and a vibrating transducer, is a fullyimplantable middle ear hearing device(F-IMEHD) for the recovery of patients with hearing loss. And since a microphone is implanted under skin and tissue at the temporal bones, the amplitude of the sound wave is attenuated by absorption and scattering. And the vibrating transducer attached to the ossicular chain caused also the different displacement from characteristic of the stapes. For the gain control of auditory signals, most of implantable hearing devices with the digital audio signal processor still apply to fitting rules of conventional hearing aid without regard to the effect of the implanted microphone and the vibrating transducer. So it should be taken into account the effect of the implantable microphone and the vibrating transducer to use the conventional audio fitting rule. The aim of this study was to measure gain characteristics caused by the implanted microphone and the vibrating transducer attached to the ossicle chains for the gain compensation of ACROSS device. Differential floating mass transducers (DFMT) of ACROSS device were clipped on four cadaver temporal bones. And after placing the DFMT on them, displacements of the ossicle chain with the DFMT operated by 1 $mA_{peak}$ current was measured using laser Doppler vibrometer. And the sensitivity of microphones under the sampled pig skin and the skin of 3 rat back were measured by stimulus of pure tones in frequency from 0.1 to 8.9 kHz. And we confirmed that the microphone implanted under skin showed poorer frequency response in the acoustic high-frequency band than it in the low- to mid- frequency band, and the resonant frequency of the stapes vibration was changed by attaching the DFMT on the incus, the displacement of the DFMT driven with 1 $mA_{rms}$ was higher by the amount of about 20 dB than that of cadaver's stapes driven by the sound presssure of 94 dB SPL in resonance frequency range.

A study on Symptom Experience, Spiritual Well-Being, and Depression in Patients Undergoing Hemodialysis (혈액투석 환자의 증상경험, 영적 안녕 및 우울에 관한 연구)

  • Song, Ju Yeon;Oh, Pok-Ja
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.660-670
    • /
    • 2016
  • This cross-sectional descriptive investigation attempted to identify the relationship among the symptoms, spiritual well-being, and depression experienced by patients undergoing hemodialysis. Data were collected from 146 patients at 6 hemodialysis clinics from October 15th, 2014 to January 15th, 2015. The Dialysis Symptom Index (DSI) was used to measure symptom experience, spiritual well-being was measured using the Spiritual Well-being Scale, and depression was assessed using the Center for Epidemiologic Studies Depression Scale (CES-D). The data were analyzed using ANOVA, the t-test, Scheffe's test, Pearson correlation, and hierarchical regression analysis. The mean score of the symptom experience was 26.43 (range: 0~85), the mean spiritual well-being score was 47.79 (range: 20~80), and the mean depression score was 10.56 (range: 0~35). It was found that greater existential well-being leads to lower depression (r=-.23, p=.004) and symptom experience (r=-.17, p=.045). Greater physical (B=.09) and emotional (B=.64) symptom experience leads to higher depression and the explanatory power of these factors was 52.1% (F=18.54, p<.001). Therefore, a comprehensive nursing intervention that can help reduce the symptom experience and increase the existential well-being in hemodialysis patients is needed to reduce their depression.

Effects of air-abrasion pressure on the resin bond strength to zirconia: a combined cyclic loading and thermocycling aging study

  • Al-Shehri, Eman Z.;Al-Zain, Afnan O.;Sabrah, Alaa H.;Al-Angari, Sarah S.;Dehailan, Laila Al;Eckert, George J.;Ozcan, Mutlu;Platt, Jeffrey A.;Bottino, Marco C.
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.3
    • /
    • pp.206-215
    • /
    • 2017
  • Objectives: To determine the combined effect of fatigue cyclic loading and thermocycling (CLTC) on the shear bond strength (SBS) of a resin cement to zirconia surfaces that were previously air-abraded with aluminum oxide ($Al_2O_3$) particles at different pressures. Materials and Methods: Seventy-two cuboid zirconia specimens were prepared and randomly assigned to 3 groups according to the air-abrasion pressures (1, 2, and 2.8 bar), and each group was further divided into 2 groups depending on aging parameters (n = 12). Panavia F 2.0 was placed on pre-conditioned zirconia surfaces, and SBS testing was performed either after 24 hours or 10,000 fatigue cycles (cyclic loading) and 5,000 thermocycles. Non-contact profilometry was used to measure surface roughness. Failure modes were evaluated under optical and scanning electron microscopy. The data were analyzed using 2-way analysis of variance and ${\chi}^2$ tests (${\alpha}=0.05$). Results: The 2.8 bar group showed significantly higher surface roughness compared to the 1 bar group (p < 0.05). The interaction between pressure and time/cycling was not significant on SBS, and pressure did not have a significant effect either. SBS was significantly higher (p = 0.006) for 24 hours storage compared to CLTC. The 2 bar-CLTC group presented significantly higher percentage of pre-test failure during fatigue compared to the other groups. Mixed-failure mode was more frequent than adhesive failure. Conclusions: CLTC significantly decreased the SBS values regardless of the air-abrasion pressure used.

Forecasting KOSPI 200 Volatility by Volatility Measurements (변동성 측정방법에 따른 KOSPI200 지수의 변동성 예측 비교)

  • Choi, Young-Soo;Lee, Hyun-Jung
    • Communications for Statistical Applications and Methods
    • /
    • v.17 no.2
    • /
    • pp.293-308
    • /
    • 2010
  • In this paper, we examine the forecasting KOSPI 200 realized volatility by volatility measurements. The empirical investigation for KOSPI 200 daily returns is done during the period from 3 January 2003 to 29 June 2007. Since Korea Exchange(KRX) will launch VKOSPI futures contract in 2010, forecasting VKOSPI can be an important issue. So we analyze which volatility measurements forecast VKOSPI better. To test this hypothesis, we use 5-minute interval returns to measure realized volatilities. Also, we propose a new methodology that reflects the synchronized bidding and simultaneously takes it account the difference between overnight volatility and intra-daily volatility. The t-test and F-test show that our new realized volatility is not only different from the realized volatility by a conventional method at less than 0.01% significance level, also more stable in summary statistics. We use the correlation analysis, regression analysis, cross validation test to investigate the forecast performance. The empirical result shows that the realized volatility we propose is better than other volatilities, including historical volatility, implied volatility, and convention realized volatility, for forecasting VKOSPI. Also, the regression analysis on the predictive abilities for realized volatility, which is measured by our new methodology and conventional one, shows that VKOSPI is an efficient estimator compared to historical volatility and CRR implied volatility.

The reliability physics of SiGe hetero-junction bipolar transistors (실리콘-게르마늄 이종접합 바이폴라 트랜지스터의 신뢰성 현상)

  • 이승윤;박찬우;김상훈;이상흥;강진영;조경익
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.4
    • /
    • pp.239-250
    • /
    • 2003
  • The reliability degradation phenomena in the SiGe hetero-junction bipolar transistor (HBT) are investigated in this review. In the case of the SiGe HBT the decrease of the current gain, the degradation of the AC characteristics, and the offset voltage are frequently observed, which are attributed to the emitter-base reverse bias voltage stress, the transient enhanced diffusion, and the deterioration of the base-collector junction due to the fluctuation in fabrication process, respectively. The reverse-bias stress on the emitter-base junction causes the recombination current to rise, increasing the base current and degrading the current gain, because hot carriers formed by the high electric field at the junction periphery generate charged traps at the silicon-oxide interface and within the oxide region. Because of the enhanced diffusion of the dopants in the intrinsic base induced by the extrinsic base implantation, the shorter distance between the emitter-base junction and the extrinsic base than a critical measure leads to the reduction of the cut-off frequency ($f_t$) of the device. If the energy of the extrinsic base implantation is insufficient, the turn-on voltage of the collector-base junction becomes low, in the result, the offset voltage appears on the current-voltage curve.

Environment in Apartment Verandas at Three Floors, and Change in Growth of Selected Ornamental Plants under Simulated Light Intensities (아파트 베란다 층별 기상환경 측정과 이에 따른 모의 광도가 오색마삭줄과 피토니아의 생육에 미치는 영향)

  • Son, Moon-Sook;Song, Ju-Yeon;Jeong, Byoung-Ryong
    • Journal of agriculture & life science
    • /
    • v.45 no.3
    • /
    • pp.43-51
    • /
    • 2011
  • This project was conducted to measure actual temperature, relative humidity (RH), and light intensity at different apartment floors and to suggest suitable indoor plants by investigating morphological changes of Treophelosparmum asiatioum and Fittonia verchaffeltii var. argyroneura as affected by light intensity. Temperature and RH in apartment verandas were measured in three different (2nd, 9th, and 16th) floors on three different buildings for 30 days seasonally. The light intensity, temperature, and RH were recorded outside (parking area) and inside apartment verandas for 24 hours on a selected sunny summer day (between Aug. 19 and Sept. 14, 2008). Based on the first study, we investigated effect of simulated light intensity (40, 70, 100, and $600{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$) on changes in growth and development of T. asiatioum and F. verchaffeltii var. argyroneurain growth chambers. However, daily mean light intensity of 2nd, 9th, and 16th floors was different each other as it was about 40, 70, and $100{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, respectively. In the growth chamber experiment, plant height, internode length, and leaf length and width were not affected significantly by light intensity, but changes in leaf color were apparent in the new leaves with the increasing light intensity. The results suggest that T. asiatioum could be best fit to high, and F. verchaffeltii var. argyroneura to lower floor verandas, considering their aesthetic values.