• Title/Summary/Keyword: F-18 FDG-PET/CT

Search Result 330, Processing Time 0.025 seconds

Uptake of $^{18}F-FDG$ in the Angioleiomyoma of the Leg ($^{18}F-FDG$ 섭취를 보인 하지의 혈관평활근종)

  • Kim, Ho-Kyun;Park, Young-Chan
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.1
    • /
    • pp.59-61
    • /
    • 2007
  • Angioleiomyoma is a rare benign tumor arising from the vascular smooth muscle (tunica media) and characterized by either a painful or painless, solitary subcutaneous nodule occurring most often in the lower extremity. We report a case of intense FDG uptake in the angioleiomyoma of right lower leg on $^{18}F-FDG$ PET/CT.

Non-specific Inflammatory Disease Showed Abnormal FDG Uptake in Lower Extremities ($^{18}F-FDG$ PET/CT 에서 하지골 골수에 다발성 이상섭취를 보인 비특이성 염증성질환)

  • Chun, Kyung-Ah;Kong, Eun-Jung;Cho, Ihn-Ho;Hong, Young-Hoon;Lee, Choong-Ki
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.79-80
    • /
    • 2008
  • Including malignancy, various disease can show abnormal uptake in bone marrow. We report a case of non-specific inflammatory FDG uptake in bone marrow mimicking malignancy. A 35-year old woman with fever of unknown origin (FUO) underwent $^{18}F$-FDG PET/CT to find out fever $^{18}F$-FDG and unknown malignancy. $^{18}F$-FDG was injected and imaged 1hr after injection with Discovery ST (GE, USA), $^{18}F$-FDG PET/CT whole body image showed abnormal uptake in lower extremities (Fig. 1). MRI and biopsy was also done in the sites of abnormal uptake. PET and MRI suspect malignancy (Fig. 2, 3), but biopsy result was non-specific inflammatory process (Fig. 4). The patient was improved her clinical condition after antibiotics therapy.

Clinical Significance of Incidental Asymmetric Palatine Tonsillar Uptake on $^{18}F$-FDG PET/CT ($^{18}F$-FDG PET/CT에서 우연히 관찰되는 구개편도의 비대칭적 섭취증가의 임상적 의의)

  • Chae, Sun-Young;Baek, So-Ra;Ryu, Jin-Sook;Moon, Dae-Hyuk;Kim, Jae-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.402-410
    • /
    • 2009
  • Purpose: The aim of this study was to determine the incidence and malignant rate of incidental asymmetric palatine tonsillar uptake (ATU) on $^{18}F$-FDG PET/CT in various clinical indications and to evaluate the clinical and PET/CT findings suggesting malignancy. Materials and Methods: We retrospectively reviewed a total of 2,901 patients ($58.4{\pm}12.3$ yrs, range 20~88 yrs, M:F = 1,841:1,060) who underwent $^{18}F$-FDG PET/CT during an 1-year period with various indications except primary tonsillar cancer and lymphoma evaluation. On $^{18}F$-FDG PET/CT, metabolic abnormality of the palatine tonsil and cervical lymph node were visually assessed. ATU was defined as increased palatine tonsillar uptake with diffuse, focal, or irregular pattern compared to contralateral side. The incidence and malignant ratio of ATU were evaluated according to clinical and PET/CT findings. Results: Of 2,901 cases, 290(10,0%) showed ATU. The incidence of ATU showed seasonal variation and was high in the winter (12.1%). Of 209 cases with ATU confirmed pathologically and/or clinically, five (2.4%) were malignant lesions. ATU with irregular uptake pattern (2/2) and in cases referred for cervical lymph node metastasis of unknown origin (3/5) were frequently associated with malignant lesion (p<0.05). Conclusion: ATU was not infrequently observed on $^{18}F$-FDG PET/CT, and the malignant risk of ATU was low. However, ATU with cervical lymph node metastasis or with irregular pattern on PET/CT would be further evaluated by the histopathologic examination.

F-18 FDG PET Scan findings in Patients with Pulmonary Involvement in the Hypereosinophilic Syndrome (원발성 과호산구증가 증후군 환자들 중 폐침범을 보이는 환자군의 F-18 FDG PET 소견)

  • Lee, Jae-Hoon;Kim, Tae-Hoon;Yun, Mi-Jin;Hur, Jin;Kim, Tae-Sung;Kim, Sang-Jin;Kim, Hyung-Joong;Pai, Moon-Sun;Ryu, Young-Hoon;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.239-245
    • /
    • 2005
  • Purpose: Hypereosinophilic syndrome (HES) is an infiltrative disease of eosinophils affecting multiple organs including the iung. F-18 2-fluoro-2-deoxyglucose (F-18 FDG) may accumulate at sites of inflammation or injection, making interpretation of whole body PET scan difficult in patients with cancer. This study was to evaluate the PET findings of HES with lung involvement and to find out differential PET features between lung malignancy and HES with lung involvement. Material and Methods: F-18 FDG PET and low dose chest CT scan was performed for screening of lung cancer. light patients who showed ground-glass attenuation (GGA) and consolidation on chest CT scan with peripheral blood eosinophilia werr included in this study. The patients with history of parasite infection, allergy and collagen vascular disease were excluded. CT features and FDG PET findings were meticulously evaluated for the distribution of GGA and consolidation and nodules on CT scan and mean and maximal SUV of abnormalities depicted on F-18 FDG PET scan. In eight patients, follow-up chest CT scan and FDG PET scan were done one or two weeks after initial study. Results: F-18 FDG PET scan identified metabolically active lesions in seven out of eight patients. Maximal SUV was ranged from 2.8 to 10.6 and mean SUV was ranged from 2.2 to 7.2. Remaining one patient had maximal SUV of 1.3. On follow-up FDG PET scan taken on from one to four weeks later showed decreased degree of initially noted FDG uptakes or migration of previously noted abnormal FDG uptakes. Conclusions: Lung involvement in the HES might be identified as abnormal uptake foci on FDG PET scan mimicking lung cancer. Follow-up FDG PET and CT scan for the identification of migration or resolution of abnormalities and decrement of SUV would be of help for the differentiation between lung cancer and HES with lung involvement.

Quantitative Comparisons between CT and $^{68}Ge$ Transmission Attenuation Corrected $^{18}F-FDG$ PET Images: Measured Attenuation Correction vs. Segmented Attenuation Correction (CT와 $^{68}Ge$ 감쇠보정 $^{18}F-FDG$ PET 영상의 정량적 비교: 측정감쇠보정대 분할감쇠보정)

  • Choi, Joon-Young;Woo, Sang-Keun;Choi, Yong;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.1
    • /
    • pp.49-53
    • /
    • 2007
  • Purpose: It was reported that CT-based measured attenuation correction (CT-MAC) produced radioactivity concentration values significantly higher than $^{68}Ge$-based segmented attenuation correction (Ge-SAC) in PET images. However, it was unknown whether the radioactivity concentration difference resulted from different sources (CT vs. Ge) or types (MAC vs. SAC) of attenuation correction (AC). We evaluated the influences of the source and type of AC on the radioactivity concentration differences between reconstructed PET images in normal subjects and patients. Material and Methods: Five normal subjects and 35 patients with a known or suspected cancer underwent $^{18}F-FDG$ PET/CT. In each subject, attenuation corrected PET images using OSEM algorithm (28 subsets, 2 iterations) were reconstructed by 4 methods: CT-MAC, CT-SAC, Ge-MAC, and Ge-SAC. The physiological uptake in normal subjects and pathological uptake in patients were quantitatively compared between the PET images according to the source and type of AC. Results: The SUVs of physiological uptake measured in CT-MAC PET images were significantly higher than other 3 differently corrected PET images. Maximum SUVs of the 145 foci with abnormal FDG uptake in CT-MAC images were significantly highest among 4 differently corrected PET images with a difference of 2.4% to 5.1% (p<0.001). The SUVs of pathological uptake in Ge-MAC images were significantly higher than those in CT-SAC and Ge-MAC PET images (p<0.001). Conclusion: Quantitative radioactivity values were highest in CT-MAC PET images. The adoption of MAC may make a more contribution than the adoption of CT attenuation map to such differences.

Radiation Exposure Dose of Handlers Using 18F-FDG in Small Animal Image Acquisition Experiments

  • Ik Soo Kim;Sun Young Yoon;Hwa Yeon Yeo
    • Journal of Radiation Industry
    • /
    • v.17 no.3
    • /
    • pp.233-238
    • /
    • 2023
  • This study was conducted to confirm the safety of the operator's radiation exposure in the micro PET-CT image acquisition experiment using the 18F-FDG. The usage of 18F-FDG and the exposure dose of handlers were measured at University B in Metropolitan City A, which uses 18F-FDG for micro PET-CT image acquisition. As a result of the measurement, the exposure dose is far below the effective dose limit of radiation workers, 50 mSv per year, and the equivalent dose limit of 500 mSv per year for hands, feet, and skin. has been measured Since these exposure doses can be further increased according to the number of times of use of 18F-FDG, it is judged that the exposure dose compared to the handling amount of 18F-FDG shown in this study can be used as reference data. In addition, as changed environments such as the use of materials other than unopened RI are occurring in education and research environments, such as the use of 18F-FDG at University B, radiation exposure with more interest in safety management by checking the factors of radiation exposure of the handler concerned We will always do our best to reduce it.

Comparison of F-18 FDG Radioacitivity to Determine Accurate Dose Calibrator Activity Measurements (방사능 측정기를 이용한 F-18 FDG 방사능의 비교)

  • Jin, Gye-Hwan;Kweon, Dae-Cheol;Oh, Ki-Baek;Park, Hoon-Hee;Kim, Jung-Yul;Park, Min-Soo;Park, Dae-Sung
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.159-166
    • /
    • 2009
  • Obviously, the administration of the prescribed amount of activity to the patient requires proper operation of the dose calibrator, which shall be verified by implementing the required quality control on the instrument. This investigation examined the accuracy and precision of dose calibrator activity measurement of the radiopharmaceutical F-18 FDG. To investigate the status of the nuclear medicine centers in Korea for the performance of dose calibrators, 10 centers providing PET/CT system services in Korea were inspected in 2008. We measured accuracy and precision in 10 equipments in consideration of PET/CT model, installation area, and installation time. According to the results of comparative analysis of 10 dose calibrators used to measure radioactivity of F-18 FDG, accuracy was -5.00~4.50% and precision was 0.05~0.45%, satisfying the international standards, which are accuracy ${\pm}$10% and precision ${\pm}$5%. This study demonstrated that, for accurate measurements, no adjustment is necessary for a dose calibrator setting when measuring different dose calibrators of F-18 FDG activity prescriptions.

  • PDF

Imaging of Gastric Cancer Metabolism Using 18 F-FDG PET/CT

  • Yun, Mijin
    • Journal of Gastric Cancer
    • /
    • v.14 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Aerobic glycolysis has been the most important hypothesis in cancer metabolism. It seems to be related to increased bioenergetic and biosynthetic needs in rapidly proliferating cancer cells. To this end, F-18 fluorodeoxyglucose (FDG), a glucose analog, became widely popular for the detection of malignancies combined with positron emission tomography/computed tomography (PET/CT). Although the potential roles of FDG PET/CT in primary tumor detection are not fully established, it seems to have a limited sensitivity in detecting early gastric cancer and mainly signet ring or non-solid types of advanced gastric cancer. In evaluating lymph node metastases, the location of lymph nodes and the degree of FDG uptake in primary tumors appear to be important factors affecting the diagnostic accuracy of PET/CT. In spite of the limited sensitivity, the high specificity of PET/CT for lymph node metastases may play an important role in changing the extent of lymphadenectomy or reducing futile laparotomies. For peritoneal metastases, PET/CT seems to have a poorer sensitivity but a better specificity than CT. The roles of PET/CT in the evaluation of other distant metastases are yet to be known. Studies including primary tumors with low FDG uptake or peritoneal recurrence seem suffer from poorer diagnostic performance for the detection of recurrent gastric cancer. There are only a few reports using FDG PET/CT to predict response to neoadjuvant or adjuvant chemotherapy. A complete metabolic response seems to be predictive of more favorable prognosis.

Basic principles and applications of $^{18}F$-FDG-PET/CT in oral and maxillofacial imaging: A pictorial essay

  • Omami, Galal;Tamimi, Dania;Branstetter, Barton F.
    • Imaging Science in Dentistry
    • /
    • v.44 no.4
    • /
    • pp.325-332
    • /
    • 2014
  • A combination of positron emission tomography (PET) with $^{18}F$-labeled fluoro-2-deoxyglucose ($^{18}F$-FDG) and computed tomography ($^{18}F$-FDG-PET/CT) has increasingly become a widely used imaging modality for the diagnosis and management of head and neck cancer. On the basis of both recent literature and our professional experience, we present a set of principles with pictorial illustrations and clinical applications of FDG-PET/CT in the evaluation and management planning of squamous cell carcinoma of the oral cavity and oropharynx. We feel that this paper will be of interest and will aid the learning of oral and maxillofacial radiology trainees and practitioners.

A Significant Discrepancy of Uptake between I-131 MIBG and F-18 FDG in a Patient With Malignant Paraganglioma (I-131 MIBG와 F-18 FDG 섭취의 불일치를 보였던 악성 부신경절종 1례)

  • Kim, Jong-Su;Kim, Hyun-Keun;Choi, Kyu-Young;Park, Hyung-Ki;Kim, Eun-Sil;Kim, Yun-Kwon;Kim, So-Yon;Kim, Young-Jung;Lee, Hyo-Jin
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.247-251
    • /
    • 2007
  • A 38-year-old man who was diagnosed with malignant paraganglioma underwent computed tomography (CT) and I-131 metaiodobenzylguanidine (MIBG) san. CT showed extensive lymph node enlargement in right iliac area and retroperitoneum with severe hydronephrosis and mass on posterior bladder wall. However, I-131 MIBG scan didn't showed abnormal uptake. He also underwent F-18 fluorodeoxyglucose (FDG) positron emisson tomography/CT for localizing accurate tumor site. F-18 FDG PET/CT showed multiple metastases of left supraclavicular, hilar, mediastinal para-aortic, inguinal, right iliac lymph nodes, lung, vertebrae, and pelvis. There are a few reports showing that the F-18 FDG PET/CT is helpful for staging and localizing tumor site of patients who are diagnosed with negative on the MIBG scans. Thus, we report a case with paraganglioma which showed negative I-131 MIBG scan, but revealed multiple intense hypermetabolic foci in F-18 FDG PET/CT.