• Title/Summary/Keyword: Eye protection

Search Result 86, Processing Time 0.03 seconds

A preliminary evaluation of the implementation of a radiation protection program for the lens of the eye in Korean nuclear power plants

  • Kong, Tae Young;Kim, Si Young;Cho, Moonhyung;Jung, Yoonhee;Son, Jung Kwon;Jang, Han;Kim, Hee Geun
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.3035-3043
    • /
    • 2021
  • Epidemiological research has revealed that radiation exposure can cause cataracts. The Korean nuclear regulatory body has proposed the reduction of the occupational dose limit for the lens of the eye from 150 mSv/y to 100 mSv/5y, with an additional limitation of not exceeding 50 mSv/y for a specific year, taking into account the recommendations of the International Commission on Radiological Protection, and the International Atomic Energy Agency. This means that radiation workers should receive the same level of radiation safety for the lens of the eye as for whole-body protection. Korean nuclear power plants (NPPs) are conducting research to establish the radiation protection program for the lens of the eye. In terms of the preliminary results of the implementation of the radiation protection program for the lens of the eye dedicated to Korean NPPs, this review article summarizes the current state of understanding of the regulations, technical guidance, eye lens dosimeters, and radiation field conditions resulting in lens dose.

An Analysis of Cross-eye Characteristics for Electronic Protection of Radar (레이다의 전자 보호용 위상정합 특성 분석)

  • Chae Gyoo-Soo;Lim Joong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.1
    • /
    • pp.52-56
    • /
    • 2006
  • This paper presents a cross-eye characteristics of multi-path wave scattering. Cross-eye method uses the phase differences of multi signals and is used fur electronic protection. When a signal is propagated from transmitter to receiver on the ground surface, direct wave and reflected wave signals are combined in front of the receiving antenna with different phases. To calculate and control the amplitude and phase of reflected signal, we have developed a cross eye electronic protection method for radar system and studied the variation of electric power density.

  • PDF

Ultraviolet Protection Property of Green Tea Extract Dyed Fabrics (녹차추출물로 염색한 직물의 자외선 차단성에 관한 연구)

  • Kim, Sin-Hee
    • Textile Coloration and Finishing
    • /
    • v.18 no.6 s.91
    • /
    • pp.80-87
    • /
    • 2006
  • Nowadays, interests of ultraviolet(UV) protection increased, since the UV dosage on the earth surface has increased over years. Overdose of UV can cause various skin, eye, and even DNA damages. Therefore, it is need to develop a proper mean to protect human skin and eye from UV radiation. In this study, the UV protective effect of green tea extract dyed fabrics with various fiber types were examined. Green tea has an active moiety called 'catechin' having benzene rings in its structure, which would exert a proper UV protective property. Green tea dyed fabrics showed the increase in UV protection, and silk showed the highest increase in UV protection (from 52.2% to 84.5% in UV-A, from 66.1% to 90% in UV-B). The order of UV-A protection increase is silk, wool, nylon and acrylic, PET, and cotton. The order of UV-B protection increase is silk nylon, wool, acrylic, cotton, and PET. In case of silk and nylon, the UV protection property gradually increased as the concentration of green tea extract increased. As a result, it was proven that green tea extract dyeing can improve UV protection property of dyed fabrics in environment-friendly and biocompatible manners.

Development of Eye Protection App using Realtime Eye Tracking and Distance Measurement Method (실시간 시선 추적과 거리 측정 기법을 활용한 눈 보호 앱 개발)

  • Lee, Hye-Ran;Lee, Jun Pyo
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2019.07a
    • /
    • pp.223-224
    • /
    • 2019
  • 본 논문에서는 카메라의 실시간 영상에서 얻을 수 있는 데이터를 수집 및 분석하여 일반인들에게 스마트폰의 실제 사용량, 최적화면 표현, 그리고 건조증 위험도의 정보를 제공하는 "i-eye" 응용 앱을 제안하여 눈 건강관리를 가능하게 한다. 제안하는 앱은 발전된 스마트 폰을 기반으로 동작되며 아이트래킹(eye-gaze tracking), 영상거리측정(image distance measurement), 눈 데이터분석(eye data analysis)의 3가지 핵심기술을 제안한다.

  • PDF

Experimental Evaluation of Scattered X-Ray Spectra due to X-Ray Therapeutic and Diagnosis Equipment for Eye Lens Dosimetry of Medical Staff

  • Kowatari, Munehiko;Nagamoto, Keisuke;Nakagami, Koich;Tanimura, Yoshihiko;Moritake, Takashi;Kunugita, Naoki
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.1
    • /
    • pp.39-49
    • /
    • 2022
  • Background: For proper monitoring of the eye lens dose, an appropriate calibration factor of a dosimeter and information about the mean energies of X-rays are indispensable. The scattered X-ray energy spectra should be well characterized in medical practices where eye lenses of medical staffs might be high. Materials and Methods: Scattered X-ray energy spectra were experimentally derived for three different types of X-ray diagnostic and therapeutic equipment, i.e., the computed tomography (CT) scan, the angiography and the fluoroscopy. A commercially available CdZnTe (CZT) spectrometer with a lead collimator was employed for the measurement of scattered X-rays, which was performed in the usual manner. Results and Discussion: From the obtained energy spectra, the mean energies of the scattered X-rays lied between 40 and 60 keV. This also agreed with that obtained by the conventional half value layer method. Conclusion: The scattered X-rays to which medical workers may be exposed in the region around the eyes were characterized by means of spectrometry. The obtained mean energies of the scattered X-rays were found to match the flat region of the dosimeter response.

A STUDY ON THE EFFECTS OF SCATTERING DOSE ON EYES AND THYROID FOR PANORAMAGRAPHY (Focus on TLD and PLD)

  • Jung, Yeun;Dong, Kyung-Rae;Kweon, Dae-Cheol;Dieter, Kevin;Goo, Eun-Hoe;Ahn, Se-Youn;Chung, Jae-Eun
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.1-5
    • /
    • 2010
  • This study concerning the surface dose of eye and thyroid from panoramagraphy used thermoluminescent dosimeter (TLD) and photoluminescent dosimeter (PLD) to take measurements at ten hospitals in the Gwangju metropolitan area. The recommendations from ICRP 60 and ICRP 73 on the allowance standard for eye are 15 mSv and for thyroid is 1 mSv. The left eye TLD and PLD values are 0.19 mSv and 0.24 mSv respectively. The right eye TLD and PLD values are 0.23 mSv and 0.25 mSv respectively. Thyroid TLD and PLD values are 0.08 mSv and 0.25 mSv respectively and did not exceed the allowance standards(p<0.001). Also comparisons are made between TLD and PLD for each organ and PLD has higher dose measurements than TLD. There are statistically significant differences in left eye measurements and thyroid measurements (p<0.01). There is no significant difference in measurements for the right eye (p>0.05). The TLD and PLD measured dose from panoramagraphy instruments on eyes and thyroid from each hospital did not exceed the recommended dose from ICRP 60 for surface dose measurements. However, due to the probability of influence, consideration should be made for all levels of dose.

A Feasibility Study on the Lens of Eye Dose Assessment Using the System of Multi-Element TLD (다중소자 열형광선량계에 의한 수정체 등가선량 평가의 적정성 연구)

  • Lee, Na-Rae;Han, Seung-Jae;Lee, Byung-Il;Cho, Kun-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.96-102
    • /
    • 2012
  • International Commission on Radiological Protection (ICRP) has revised its recommendations concerning the tissue reaction to ionizing radiation in accordance with consideration of the detriment arising from non-cancer effects of radiation on health based on recent epidemiological basis. Particularly, for the lens of the eye, the threshold in absorbed dose revised to be 0.5 Gy, for occupational exposure in planned exposure situation the commission recommended "An equivalent dose limit for the lens of the eye of 20 mSv in a year, averaged over defined periods of 5 years, with no single year exceeding 50 mSv." To monitor the radiation exposure of radiation worker, TLD is typically provided and the lens of eye dose can be assessed by run of dose calculation algorithm with TL element response data. This study is to assess equivalent dose of the lens of eye using the Harshaw TLD system and its two different dose calculation algorithms. The result provides the Harshaw TLD system showed the assessment of the lens of eye dose with 48.84% error range.

Development of a New Hibiscus Cultivar 'Daewangchun' with Vigorous Growth and Unique Red Eye through Interspecific Hybridization

  • Ha, Yoo-Mi;Lim, Ki-Byung;Shim, Kyung-Ku
    • Horticultural Science & Technology
    • /
    • v.33 no.3
    • /
    • pp.453-458
    • /
    • 2015
  • A new Hibiscus cultivar 'Daewangchun', having vigorous growth, uniform plant habit, upright, compact branches, and a long red eye was developed through interspecific crosses between H. syriacus 'Samchully' (♀) and H. sinosyriacus 'Seobong' (♂). The Hibiscus breeding program was initiated in 2005 and Hibiscus ${\times}$ 'Daewangchun' was preliminarily selected as '05-R-204' in 2 008 due to its vigorous growth and stable flower quality w ith rich pink flowers. The s elected line was further evaluated for different growth characteristics, leaf shape, leaf size, and flowering characteristics, as well as tested for distinctness, homogeneity, and stability during 2010-2012. The new cultivar 'Daewangchun' had violet pink flowers (RHS N80C) with a long red eye spot, medium size and fan petals. The size of flower was 12.0 cm and size of the red eye was 3.0 cm. Leaves were 8.7 cm long and 4.7 cm wide. After plant characteristic evaluation for 3 years (2010-2012), 05-R-204 was registered as cultivar 'Daewangchun' (4731, No. of plant variety protection rights) in 2013. This newly developed cultivar 'Daewangchun' has tall vigorous growth and unique flowers with a long red eye and can be used as specimen plants in landscaping.

Development of Detailed Korean Adult Eye Model for Lens Dose Calculation

  • Han, Haegin;Zhang, Xujia;Yeom, Yeon Soo;Choi, Chansoo;Nguyen, Thang Tat;Shin, Bangho;Ha, Sangseok;Moon, Sungho;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.1
    • /
    • pp.45-52
    • /
    • 2020
  • Background: Recently, the International Commission on Radiological Protection (ICRP) lowered the dose limit for the eye lens from 150 mSv to 20 mSv, highlighting the importance of accurate lens dose estimation. The ICRP reference computational phantoms used for lens dose calculation are mostly based on the data of Caucasian population, and thus might be inappropriate for Korean population. Materials and Methods: In the present study, a detailed Korean eye model was constructed by determining nine ocular dimensions using the data of Korean subjects. The developed eye model was then incorporated into the adult male and female mesh-type reference Korean phantoms (MRKPs), which were then used to calculate lens doses for photons and electrons in idealized irradiation geometries. The calculated lens doses were finally compared with those calculated with the ICRP mesh-type reference computational phantoms (MRCPs) to observe the effect of ethnic difference on lens dose. Results and Discussion: The lens doses calculated with the MRKPs and the MRCPs were not much different for photons for the entire energy range considered in the present study. For electrons, the differences were generally small, but exceptionally large differences were found at a specific energy range (0.5-1 MeV), the maximum differences being about 10 times at 0.6 MeV in the anteroposterior geometry; the differences are mainly due to the difference in the depth of the lens between the MRCPs and the MRKPs. Conclusion: The MRCPs are generally considered acceptable for lens dose calculations for Korean population, except for the electrons at the energy range of 0.5-1 MeV for which it is suggested to use the MRKPs incorporating the Korean eye model developed in the present study.

Radiation Exposure Evaluation of Visual Organs using Bismuth Shielding Material on Head CT Scan (두부 CT촬영 시 비스무스 차폐체를 활용한 시각 기관의 방사선피폭평가)

  • Kang, Se-Sik;Kim, Changsoo;Kim, Jung-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.7
    • /
    • pp.451-456
    • /
    • 2016
  • To analyse the absorbed radiation dose of the visual organs (eyes, corneas, lenses) during a head CT scan, a with the purpose of radiation protection was designed. Afterwards, the reduction rate of radiation dose when using an eye-shielding was analyzed. The results showed that the higher the energy, the higher the absorbed dose of the eyes. Excluding the head, the organs with high dose were the eyes, corneas, and lenses, respectively. Furthermore, the dose reduction rate before and after shielding was between 38% and 55% for the eyes, and between 35% and 52% for the corneas. In the case of the lenses, when the front was shielded, the reduction rate was 51%, and when the front and the side were shielded simultaneously, the reduction rate was 67%.