• Title/Summary/Keyword: Eye ball movement

Search Result 5, Processing Time 0.019 seconds

Development of compact environment control system using eye-ball movement

  • Shin, Young-Kyun;Muhammad, Arif;Hikaru, Inooka
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.77.4-77
    • /
    • 2002
  • Communicating devices for the seriously disabled using eye-ball movement or some body movement are proposed. The first one is a device to use image processing, whose input signal is eyeball movement, A feature of this device is that the device can be readily realized using a note-book computer with USB (Universal Serial Bus) interface bus. This device is incorporated with a word processing software called Nearly Ladder. The second one is an emergency call switch which is used by a patient who can move his finger slightly. The patients can switch on the emergency switch only by touching a switch with his finger. The essence of this sensor is a touch sensor. The sensor can be realized using onl...

  • PDF

Domestic Occupational Therapist Awareness Survey for the Need to Apply Artificial Intelligence Measurement Technology for Clinical Observation Evaluation Based on Sensory Integration (감각통합에 기초한 임상 관찰 평가의 AI 측정 기술 적용 필요성을 위한 국내 작업치료사 인식 조사)

  • Cho, Sun-Young;Jung, Young-Jin;Kim, Jung-Ran
    • Therapeutic Science for Rehabilitation
    • /
    • v.12 no.1
    • /
    • pp.23-35
    • /
    • 2023
  • Objective : This study is to examine the practical use of clinical observational evaluation of sensory integration therapy and the difficulty and importance of measuring results for each sub-item, and through this, to confirm the usefulness of the application of Artificial Intelligence measurement technology in clinical observational measurement and the need for application. Methods : The questionnaire consisted of the actual use of the sensory integration evaluation tool, the difficulty of measurement for each detailed item of clinical observation, the usefulness of AI measurement technology, the importance of evaluation for each detailed item, and the need for developing AI measurement technology. Results : The detailed items that were difficult to measure during clinical observation were the Finger-to-Nose Test and Postural control (71.0%), followed by Eye movement and Protective Extension Test (67.7%). 83.9% of the study subjects answered that it would be useful to apply AI measurement technology when observing images. Postural control (on the ball) (90.3%) was the highest item that answered that AI measurement technology was needed, followed by Eye movement (83.9%), and Prone Extension and Protective Extension Test (77.4%). Conclusion : The results confirmed the desire of therapists that clinical observation is an important evaluation tool in the field of child occupational therapy in Korea.

A Clinical Case Report of Oculomotor Nerve Palsy (동안신경마비 사시환자 1례 증례보고)

  • Eom, Yu-Sik;Sim, Seong-Yong;Nam, Hye-Jeong;Kim, Gyeong-Jun
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.17 no.3
    • /
    • pp.126-130
    • /
    • 2004
  • Oculomotor nerve palsy presents itself with sudden onset unilateral ptosis and inability to turn the eye upward, downward, or inward, which causes visual disturbances. Strabismus caused oculomotor nerve palsy refers to muscle imbalance that results in improper alignment of the visual axes of the two eyes It may be divided into paralytic and non paralytic strabismus. paralytic strabismus is primarily a neurologic problem. Characteristic clinical disturbances result from lesions of the third, fourth, and sixth cranial nerves. Lesions of the third nerve result in a paralysis of lateral or outward movement and a crossing of the visual axes. Objective: This study was designed to evaluate the effects of oriental medicine therapy on a peripheral oculomotor nerve palsy. Methods & Result: The clinical data was analyzed on a patient with oculomotor nerve palsy whose main symptoms were right side ptosis and inability to turn the eye inward. The patient was treated by the electroacupucture(4Hz frequency, intensity was adjusted so that localized muscle contractions could be seen). As the result, symptoms are improved remarkably. Conclusion: The patient showed right eye ptosis and unilateral deviation of the right eye ball in neutral position. After acupuncture treatment and electroacupuncture treatment, the ptosis and deviation of the patient's right eye was recovered six weeks after the onset. The study suggests that oriental medicine therapy is significantly effective on the treatment of peripheral oculomotor nerve palsy.

  • PDF

The Effect of Visual Health Promotion Program in Elementary School-Age Children (초등학생 시력건강증진 프로그램 효과)

  • Oh, Jin-Joo;Shin, Hee-Sun
    • Research in Community and Public Health Nursing
    • /
    • v.12 no.2
    • /
    • pp.397-405
    • /
    • 2001
  • The vision disturbances of school- age children has been recognized as and important school health problem. As the visual disturbances of the school-age children is recognized as the nation's health problem. the importance of the development of educational program for visual health should be emphasized. Recently, eyeball movement and other visual health management method has been introduced for prevention or recovery of decrease in visual acuity. But, the effect of eyeball movement was not confirmed yet. And, the controversy around the treatment effect is continued. The decrease of visual acuity is one of the important school health problem as well as it causes discomfort in daily life of the students. So, it should be considered as an important subject for school health and there is a need to develop an effective intervention program for visual health. The purpose of this study is to develop and evaluate the program with the recognition of the need of the intervention for visual health. The visual health promotion program was developed by the researcher and the program was initiated by the school. Nonequivalent control group pretest-posttest design was applied for study which examined the effect of the visual health promotion program. The subjects were 742 children (experimental group: 398; control group: 344). The experiment was composed of health education and eyeball movement. Health education was provided 5 times to the children in the class room. Children of experimental group exercised eyeball movement in the class, watching video for 10 minutes two times a day. The exercise was continued for 10 weeks. The result of the study were as follows. 1) change of visual acuity Before the intervention, mean of the visual acuity was .86 for the experimental group and .91 for control group. After the intervention, mean of visual acuity was .95 for the experimental group and. 90 for the control group. There was no significant difference in the change of visual acuity between experimental and control group. 2) change of refraction. In the experimental group, 327 eyes (41.08%) were normal vision and 469 eyes (58.98%) were eyes of refraction errors, 38.82 % of the total eyes were myopia. There was no significant change in the refraction in the children with myopia after the intervention. 3) Awareness of visual acuity, change of knowledge, behavior. and attitude (1) After the intervention, there was a significant difference in the awareness of visual acuity (experimental group: 70.10%. control group: 50.97%, p<.01). (2) After the intervention, there was a significant knowledge increase in the experimental group (pp<.01). (3) There was no significant difference in the visual health behavior after the intervention. (4) There was a significant positive change in the attitude related to visual health in the experimental group ( pp<.05). 4) There was a significant positive change in the subjective discomfort of the students. But, there was no significant change in the objective eye symptom after the intervention. Even though there was no effect in the visual acuity and the change of the refraction. subjective visual health as well as the attitude and knowledge' of the children and parents toward visual health was improved significantly. Also, there was an increase in the intention of change and the awareness for the visual health management. It is suggested that various educational strategies for visual health promotion should be developed and examined for the visual health promotion of the students.

  • PDF

Optical System Design for Real-Time 3-Dimension Ophthalmoscope (실시간 3차원 검안경의 광학설계)

  • Lee, Soak-Hee;Yang, Yun-Sik;Choe, Oh-Mok;Sim, Sang-Hyun;Doo, Ha-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.35-39
    • /
    • 2003
  • The display technology on the retina is the key role in inspecting the condition of the patients. 2-dimensional retina image is widely used in the eye examination as of today. Recently, 3-dimensional retina image ones have been introduced to this area, but the quality of the image is not fully satisfied to the operator. For the purpose of developing 3-D retina imaging instrument, the optimization of a 3-D retina imaging system using Code-V tool was investigated in this thesis. He-Ne laser having the wavelength 632.8 nm was used to make a power source to detect the retina. Several lenses and mirrors installed on sledge which were developed to perform focus control on 3-D device were designed to make a beam focusing and direct line. Polygon scanner having 24 mirror facets and galvanometer making tilting movement were utilized to make a 2-D laser plane. Also, design of eye ball had been fulfilled to see the focus of the 2-D plane. Reflected ray from retina detected on the sensor array with the same path. All cognitive components were optimized for aberration correction in order to focus on retina. Results of optimization were compared to those of initial designed optics system. On the basis of above results, the result of third aberration has been corrected to stable values to the optical system. MTF evaluating the resolution of an image has been closely correlated to the diffraction limit and PSF indicating the strength distribution of an image has shown the SR value as 0.9998 having high performance. The possibility of new and powerful 3-D retina image instrument was verified by simulating each component of the instrument by Code-V.

  • PDF