• Title/Summary/Keyword: Extraction efficiency

Search Result 1,153, Processing Time 0.029 seconds

Influences of direction for hexagonal-structure arrays of lens patterns on structural, optical, and electrical properties of InGaN/GaN MQW LEDs

  • Lee, Kwang-Jae;Kim, Hyun-June;Park, Dong-Woo;Jo, Byoung-Gu;Oh, Hye-Min;Hwang, Jeong-Woo;Kim, Jin-Soo;Lee, Jin-Hong;Leem, Jae-Young
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.153-153
    • /
    • 2010
  • Recently, to develop GaN-based light-emitting diodes (LEDs) with better performances, various approaches have been suggested by many research groups. In particular, using the patterned sapphire substrate technique has shown the improvement in both internal quantum efficiency and light extraction properties of GaN-based LEDs. In this paper, we discuss the influences of the direction of the hexagonal-structure arrays of lens-shaped patterns (HSAPs) formed on sapphire substrates on the crystal, optical, and electrical properties of InGaN/GaN multi-quantum-well (MQW) LEDs. The basic direction of the HSAPs is normal (HSAPN) with respect to the primary flat zone of a c-plane sapphire substrate. Another HSAP tilted by 30o (HSAP30) from the HSAPN structure was used to investigate the effects of the pattern direction. The full width at half maximums (FWHMs) of the double-crystal x-ray diffraction (DCXRD) spectrum for the (0002) and (1-102) planes of the HSAPN are 320.4 and 381.6 arcsecs., respectively, which are relatively narrower compared to those of the HSP30. The photoluminescence intensity for the HSAPN structure was ~1.2 times stronger than that for the HSAP30. From the electroluminescence (EL) measurements, the intensity for both structures are almost similar. In addition, the effects of the area of the individual lens pattern consisting of the hexagonal-structure arrays are discussed using the concept of the planar area fraction (PAF) defined as the following equation; PAF = [1-(patterns area/total unit areas)] For the relatively small PAF region up to 0.494, the influences of the HSAP direction on the LED characteristics were significant. However, the direction effects of the HSAP became small with increasing the PAF.

  • PDF

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2006.11a
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF

The Evaluation of Recovery Rate of Radioimmunoassay Using Certified Reference Material (CRM) (인증표준물질(CRM)을 이용한 방사면역측정법의 회수율 평가)

  • Choi, Sung Hee;Shin, Sun Young;Lim, So Hee;Hong, Mee Kyung;Noh, Gyeong Woon;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.158-162
    • /
    • 2014
  • Purpose: Reference material (RM) is defined as material that is safe and homogeneous enough about specified characteristic that is made with a purpose of using test of measurement or nominal characteristic. Certified reference material (CRM), which is issued by authorized organization, is defined as reference material that provides characteristic value, link uncertainty and retroactivity. The purpose of this paper was to evaluate recovery of radioimmunoassay by Certified Reference Material enclosed with a certificate and therefore to enhance reliability of test. Materials and Methods: WHO certified reference material is purchased from NIBSC (National Institute for Biological Standard and Control, United Kingdom) and made of 3 levels that are C-1 (low concentration), C-2 (medium concentration) and C-3 (high concentration) and measured for kit at the Seoul National University Hospital. Recovery rate is evaluated after measurement at four different days. Results: Recovery rate results using WHO certified reference material are T4 90%, Ferritin 88%, PSA 94%, Prolactin 99%, AFP 94% and TSH 93%. Conclusion: A procedure that appropriate accuracy, precision, specificity, sensitivity, reproducibility, and validate on the subject of kit for radioimmunoassay is essential. Recovery rate assay as extraction efficiency of analysis process is percent about already measuring results of analysis result after all measuring process. This is very important assessment standards of performance evaluation of immunoassay kit. Recovery rate results of 6 type used WHO CRM are satisfactory to 88~99%. This demonstrates that the radioimmunoassay is a very accurate measurement, which is very effectively utilized in clinical practice.

  • PDF

A Study on the Quantitative Recovery of Dissolved Inorganic Carbonates in Ground Water for Radiocarbon Measurement (방사성탄소 측정을 위한 지하수 중에 용존된 무기탄소 화합물의 정량적 회수 연구)

  • Chun, Sang-Ki;Woo, Hyung-Joo;Cho, Soo-Young;Kim, Nak-Bae;Lee, Jong-Dae
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.284-289
    • /
    • 1999
  • Dissolved inorganic carbonates in ground water were quantitatively recovered by using gas evolution method. Gas evolution method was found to be less time-consuming, less susceptible to the contamination fromatmospheric $CO_2$ and little affected by the sulfate ions in comparison to the direct precipitation method. Extraction efficiency of nearly 99% could be achieved by gas evolution method in two hours using recirculated gas at a sweeping rate of 4 liter per minute. Samples for carbon isotope fractionation study were collected in three fractions with collection times. The evolution time for the first fraction was one hours, and then second and third fractions were collected at intervals of 30 minutes, respectively. A small portion of each fraction was analyzed to evaluate ${\delta}^{13}C$ values, which were measured to be -7.9‰, -3.0‰ and +0,4‰ for the each fraction. The result clearly indicated that gas evolution method generates isotopically lighter carbon at the beginning of the purging process and heavier isotopes at the end. However, this isotope fractionation effect could be neglected by the almost complete recovery of carbonates.

  • PDF

Electrochemical Characteristics of Lithium Battery Anode Materials Using Petroleum Pitches (석유계 피치를 사용한 리튬전지 음극소재의 전기화학적 특성)

  • Hwang, Jin Woong;Lee, Jong Dae
    • Applied Chemistry for Engineering
    • /
    • v.28 no.5
    • /
    • pp.534-538
    • /
    • 2017
  • In this study, the molecular weight controlled pitches derived from pyrolyzed fuel oil (PFO) were prepared using solvent extraction and were carbonized. Electrochemical characteristics of lithium battery anode materials were investigated using these petroleum pitches. Three pitch samples prepared by the thermal reaction were 3903 (at $390^{\circ}C$ for 3 h), 4001 (at $400^{\circ}C$ for 1 h) and 4002 (at $400^{\circ}C$ for 2 h). The prepared hexane insoluble pitches were analysed by XRD, TGA, SEM and Gel permeation Chromatography (GPC). The electrochemical characteristics of the PFO-derived pitch as an anode material were investigated by constant current charge/discharge, cyclic voltammetry and electrochemical impedance tests. The coin cell using pitch (4001) and the electrolyte of $LiPF_6$ in organic solvents (EC : DMC = 1 : 1 vol%, VC 3 wt%) has better initial capacity (310 mAh/g) than that of other pitch coin cells. Also, this carbon anode showd a high initial efficiency of 82%, retention rate capability at 2 C/0.1 C of 90% and cycle retention of 85%. It was found that modified pitches improved the cycling and rate capacity performance.

A Study on the Solubilization of $\alpha$-Chymotrypsin Using AOT Reverse Micelles; Effects of pH and salts (AOT 역미셀을 이용한 $\alpha$-chymotrypsin의 가용화에 대한 연구;pH와 염의 영향)

  • 노선균;강춘형
    • KSBB Journal
    • /
    • v.15 no.6
    • /
    • pp.664-669
    • /
    • 2000
  • Micellar aggregates are known to be useful for the selective isolation of biologically active materials such as amino acids, proteins, and enzymes from crude mixtures sparsely dispersed in water. In this study, the effects of pH, salt type and its concentration on the solubilization of $\alpha$-chymotrypsin into the organic micellar phase, which consisted of AOT (sodium 야(2-ethylhexy)sulfosuccinate) and iso-octane, were comprehensively examined. It was found that maximum extraction efficiency was attained at a pH below the isoelectric point of $\alpha$-chymotrypsin; at pH=5.0 for NaCl and KCl, and at pH=7.0 for $CaCl_2$and $MgCl_2$. In order to avoid complications stemming from the precipitationof protein at low pH interfaces, the protein concentrations in the organic and aqueous phases were directly measured. The size of the micelle water pool was estimated by measuring the molar ratio of the surfactant to the water, W(sub)o. The resulting values of W(sub)o were nearly constant at 30 and 19 for NaCl and KCl, respectively, and were independent of pH. The addition of 1:2 salts like $MgCl_2$and $CaCl_2$ led to much lower, but a constant value of, W(sub)o than the 1:1 salts.

  • PDF

Looking for an Adequate Methodology for the Korean Reservoir Using Canonical Correspondence Analysis (CCA를 통한 한국 호소 연구 방법론 탐색)

  • Chung, Sang-Ok;Jeon, Hyoung-Joo;Hong, Kwan-Eui;Kim, Jong-Hwa;Park, Young-Seuk
    • Korean Journal of Environment and Ecology
    • /
    • v.20 no.4
    • /
    • pp.365-373
    • /
    • 2006
  • With a few exceptions, Korean lakes are artificially constructed for multi-purposes throughout the country. In the majority of cases, a lake is in a multiple series of reservoirs along a river or is an estuary Moreover, nutrient supplying activities (including sand extraction) and biomanipulation(esp., overfishing and fish introduction) are omnipresent in most cases. Furthermore, there is an Asian monsoon every year. In brief, europhication and algal blooms break out as a result of complicated causes. However limnological monitoring and scientific working programs are in the course of beginning. The question is what kind of strategy is desirable to establish a solid limnological database for the efficiency of the restoration process in each Korean reservoir We present light monitoring cases on the basis of algal and some physicochemical data in 2005. Do they give some useful informations despite their simplicity. Based on physicochemical factors and phytoplankton data using Utermohl method and Canonical Correspondence Analysis(CCA) were performed for Lake Cheongpyeong, Lake ASan, Lake Namyang, and Lake SapGyo. The results of CCA showed that Lake Cheongpyeong was different from the other three Lakes at estuary. Also each Lake at estuary was slightly different from one other. This result would encourage to initiate building an adequate Korean reservoir-ecosystem understanding and models for better ecological management despite the limited data. However, the results also indicate to sustain collecting ecological data and building database to interpret the Korean ecological reservoir model.

Effect of $\gamma$-Irradiation of Volatile Organic Compounds of Houttuynia cordata Thunb. (방사선 조사에 의한 어성초의 휘발성 유기성분 변화)

  • Ryu, Keun-Young;Shim, Sung-Lye;Jung, Min-Seok;Jun, Sam-Nyeo;Jo, Cheor-Un;Song, Hyun-Pa;Kim, Kyong-Su;Kim, Youn-Soon
    • Food Science and Preservation
    • /
    • v.15 no.3
    • /
    • pp.411-420
    • /
    • 2008
  • This study was performed to examine the effect of $\gamma$-irradiation on the volatile organic compounds in Houttuynia cordata Thunb.(H. cordata). 1be volatile compounds of non-irradiated and 10 kGy $\gamma$-irradiated H. cordata were isolated using SDE apparatus and analyzed by GC/MS. For each treatment the number of volatile compounds were detected at 83 and 85, respectively, 1be predominant functional groups of volatile organic compounds from H. cordata were identified as alcohols and ketones. H. cordata was mainly composed of hexahydrofarnesyl acetone (12.81 %), phytol, decanoic acid, dodecanoic acid, octadecanol, caryophyllene oxide, 2-undecanone and menthol. Houttuynum which is characteristic compound of H. cordata was found in all samples and there was no significant difference with irradiation doses. Consequently, $\gamma$-irradiation of H. cordata would be an effective process for sanitation and to increase extraction efficiency.

Reduction in Residual Pesticides and Quercetin Yields in Onion Peel Extracts by Washing (세척방법에 따른 양파껍질추출물의 Quercetin수율 및 잔류농약 제거효과)

  • Jeong, Eun-Jeong;Cha, Yong-Jun
    • Journal of Life Science
    • /
    • v.22 no.12
    • /
    • pp.1665-1671
    • /
    • 2012
  • This study was conducted to assess the removal of residual pesticides and to obtain high amounts of quercetin in onion peel extracts (OPEs) by 4 washing treatments. Washing is one of the standard processing steps in obtaining functional food ingredients from onion peel. After a first detergent wash (0.2% w/v) (DW) and hot air drying ($80^{\circ}C$, 24 hr) (B), 4 washing treatments were tested, including a second DW (C), ultrasonication ($50^{\circ}C$, 10 min) plus DW (D), 0.3% $H_2O_2$ (v/v) plus DW (E), and blanching ($95-97^{\circ}C$, 2 min) plus DW (F). This was followed by 60% (v/v) ethanol extraction and vacuum freeze drying of the OPE. The E treatment yielded 89.04% OPE and a quercetin content of 96.84% in the OPE compared with the B treatment, and had the highest efficiency of all treatments tested. The OPE was tested for the presence of 177 residual pesticides and three compounds were detected in all treatments: cyhalothirn, fluquinconazole and procymidone. Cyhalothirn and fluquinconazole levels were below the permitted levels for fresh onion, while procymidone was present in the high level range of 128.01~133.46 mg/kg in all samples. The E treatment was a better washing method than the others for removal of residual pesticides. It could reduce the level of residual pesticides without changing the functional properties of the OPE.

Applicability Test of Various Stabilizers for Heavy Metals Contaminated Soil from Smelter Area (제련소 주변 오염토양의 중금속 안정화를 위한 다양한 안정화제의 적용성 연구)

  • Jeon, Jonwon;Bae, Bumhan;Kim, Younghun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.11
    • /
    • pp.63-75
    • /
    • 2010
  • There are several remediation technologies for heavy metal contaminated soils but increasing cost limits the application of the technology if the contaminated area is large. Therefore, stabilization, which blocks the release of heavy metals or makes slow the release, is one of the applicable technology for the heavy metal contaminated soil. Current study is an applicability test for a smelter area with various stabilizer such as magnetite, hematite, zeolite-A, zeolite-X, zeolite-Y, zinc oxide, calcium oxide, carbon trioxide, manganese oxide, manganese dioxide, fish bone, sodium phosphate. The soil contaminated with arsenic, lead, copper, nickel, and zinc could not be stabilized only one stabilizer which is known to have stability for certain metal. Many of the stabilizer works for a few metal but not all of the heavy metal. In several cases, stabilizers increase the release of the other metals while they stabilize some metals. In general, the stabilizing efficiency was increased with time. For Ni, Pb, calcium oxide, carbon trioxide, manganese oxide had good stabilizing effect in water extractable portion. For Cu, manganese oxide, zeolite showed good results especially in the exchangeable portion of the sequential extraction. For As, magnetite had good ability but most of the metal oxide which showed good result for other heavy metals increased with the release of As. Current study suggest that multiple stabilizers are needed for the contaminated soil and dose of the stabilizer and stabilizing time should be carefully considered for the soil contaminated with various metals.