• Title/Summary/Keyword: Extraction constant

Search Result 251, Processing Time 0.023 seconds

Analysis of Symmetric Coupled Line with New Crossbar Embedded on Si-based Lossy Structure using the FDTD Method (실리콘에 기초한 새로운 크로스바 구조의 손실있는 대칭 결합선로에 대한 유한차분법을 이용한 해석)

  • Kim, Yoonsuk
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.4 no.2
    • /
    • pp.122-129
    • /
    • 2001
  • A characterization procedure for analyzing symmetric coupled MIS(Metal-Insulator-Semiconductor) transmission line is used the same procedure as a general single layer symmetric coupled line with perfect dielectric substrate from the extraction of the characteristic impedance and propagation constant for even- and odd-mode. In this paper, an analysis for a new substrate shielding symmetric coupled MIS structure consisting of grounded crossbar at the interface between Si and SiO2 layer using the Finite- Difference Time-Domain(FDTD) method is presented. In order to reduce the substrate effects on the transmission line characteristics, a shielding structure consisting of grounded crossbar lines over time-domain signal has been examined. Symmetric coupled MIS transmission line parameters for even- and odd-mode are investigated as the functions of frequency, and the extracted distributed frequency- dependent transmission line parameters and corresponding equivalent circuit parameters as well as quality factor for the new MIS crossbar embedded structure are also presented. It is shown that the quality factor of the symmetric coupled transmission line can be improved without significant change in the characteristic impedance and effective dielectric constant.

  • PDF

Improved Parameter Computation Method Applications of Storage Function Model for the Han River Basin (저류함수모형 매개변수 산정 개선방법의 한강유역 적용)

  • Jeong, Dong-Kug;Jeon, Yong-Woon;Lee, Beum-Hee
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.2
    • /
    • pp.149-158
    • /
    • 2008
  • The parameters of each basin, required for the accurate analysis of flood runoff using Storage Function Model, are estimated. Prior to the estimation, sensitivity analysis and extraction of new regional topographic factors for Han River basin are conducted. Based on the result, the outflow constant of basin model is calculated through regression analysis in relation with pre-flood runoff depth. The storage constant of basin model is derived by the optimum storage constant equation, according to the flood event of each basin. The model using the mentioned parameters was compared with K-Water model of Korea Water Resources Corporation and the model of Han River Flood Control Office, and proved to correspond to the observed hydrograph more.

A Multi-Indexes Based Technique for Resolving Collision in a Hash Table

  • Yusuf, Ahmed Dalhatu;Abdullahi, Saleh;Boukar, Moussa Mahamat;Yusuf, Salisu Ibrahim
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.9
    • /
    • pp.339-345
    • /
    • 2021
  • The rapid development of various applications in networking system, business, medical, education, and other domains that use basic data access operations such as insert, edit, delete and search makes data structure venerable and crucial in providing an efficient method for day to day operations of those numerous applications. One of the major problems of those applications is achieving constant time to search a key from a collection. A number of different methods which attempt to achieve that have been discovered by researchers over the years with different performance behaviors. This work evaluated these methods, and found out that almost all the existing methods have non-constant time for adding and searching a key. In this work, we designed a multi-indexes hashing algorithm that handles a collision in a hash table T efficiently and achieved constant time O(1) for searching and adding a key. Our method employed two-level of hashing which uses pattern extraction h1(key) and h2(key). The second hash function h2(key) is use for handling collision in T. Here, we eliminated the wasted slots in the search space T which is another problem associated with the existing methods.

A simple model and parameter extraction method for the description of ON-current of LT-PS TFT

  • Chung, De-Will;Park, Jun-Young;Park, Sang-Gyu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.759-762
    • /
    • 2006
  • A simple SPICE model for the description of the on-current of low-temperature poly-silicon thin film transistors is proposed. By employing constant mobility, $V_GS$ dependent alpha parameter, and exponential kink effect, very good agreements between the model and measurement were obtained.

  • PDF

FDTD Simulations of Electromagnetic Resonance Scattering for the Extraction of the Dielectric Constant (유전율 추출을 위한 공진산란의 FDTD 시뮬레이션)

  • 전상봉;정용화;안창희
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2002.11a
    • /
    • pp.113-117
    • /
    • 2002
  • 최근 산란함수의 곱셈전개에 근거를 둔 새로운 공명 산란이론이 개발되어 공명성분의 크기와 위상을 수치적으로 정확하게 얻게 해 주었다. 또한 음파분야에서는 공명스펙트럼을 얼기 위해 MIIR 라는 실험방법을 개발되어 사용하여 왔다. 본 논문에서는 원통형 유전체에 의한 산란장 문제에 공진 산란이론을 적용하여 공진 주파수를 얻고, MIIR 의 실험 모델에 수치 해석방법인 FDTD를 적용하여 이로부터 역으로 유전율 등에 관한 정보를 얻기 위한 산란장 스펙트럼을 예측하였다.

  • PDF

불포화 자연토의 포화도에 따른 동전기 정화특성에 관한 실험적 연구

  • 김병일;김익현;김기년;김수삼
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.302-305
    • /
    • 2003
  • The electrokinetic remediation tests for natural soil contaminated by lead are performed on unsaturated conditions, in which the degree of saturation is controlled through the changes in water content and the constant unit weight. At the degree of saturation of 70% the small acid range and electrical potential is developed. The changes in the water content are little above the saturation of 90%. But it is increased by 1.7 times at the degree of saturation of 70%. Finally, the efficiency of extraction is improved at 70% than 100%.

  • PDF

Measurement of the Propagation Constant of a Power Cable Using a Two-Port Time-Domain Reflectometry Technique (Two-Port Time Domain Reflectometry 방법을 이용한 XLPE 전력용 케이블의 전파 특성 측정)

  • Shin, Dong Sik;Cho, Hyeon Dong;Park, Wee Sang;Yi, Sang-Hwa;Sun, Jong-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.3
    • /
    • pp.310-315
    • /
    • 2013
  • This paper presents a two-port time-domain reflectometry(TDR) measurement technique for extracting the complex propagation constant of a cross-linked polyethylene(XLPE) cable. For the extraction, a short pulse transmitted through the cable is measured in the time domain and analyzed in the frequency domain. The propagation constant of a 22.9 kV XLPE cable with a conductor area of 325 $mm^2$ is extracted up to a frequency of approximately 2.14 GHz. The $S_{21}$ measured using a network analyzer and the two-port TDR technique are compared for verification. As a result compared with previous TDR method, the upper possible frequency limit for extracting the propagation constant increases and the measurement error decreases.

Supercritical $CO_2$ Extraction of Sesame Oil with High Content of Tocopherol (초임계 이산화탄소를 이용한 토코페롤 고함유 참기름 추출)

  • Ju Young-Woon;Son Min-Ho;Lee Ju-Suk;Byun Sang Yo
    • KSBB Journal
    • /
    • v.20 no.3
    • /
    • pp.210-214
    • /
    • 2005
  • The characteristics of sesame oil containing one of natural antioxidant, ' $\gamma$-tocopherol', were studied with the supercritical $CO_2$ extraction. Although $\gamma$-tocopherol has a lower vitamin E value in biological systems than $\alpha$-tocopherol, it is a more potent antioxidant with in oils. For the research of various factors influence to the $\gamma$-tocopherol contents increment, we have checked roasting time and temperature, as well as pressure, temperature and flow rate of supercritical fluid. As a result, we found that the $\gamma$-tocopherol content was maintained constant under the condition of roasting temperature over $200^{\circ}C$. With the longer roasting time, $\gamma$-tocopherol content was increased. Except 250 bar, the $\gamma$-tocopherol content was maintained constant under the condition of the various pressure of supercritical fluid. But $\gamma$-tocopherol content was increased with lower flow rate of supercritical fluid from 1 $m{\ell}$/L to 3 $m{\ell}$/L. When the extraction performance with the supercritical fluid was compared to the conventional compressed extraction, $\gamma$-tocopherol content was increased up to 1.6 times.

Extraction of Glabridin from Licorice Using Supercritical Carbon Dioxide (초임계 이산화탄소를 이용한 감초 중의 glabridin 추출)

  • Cho Yun-Kyoung;Kim Hyun-Seok;Kim Ju-Won;Lee Sang-Yun;Kim Woo-Sik;Ryu Jong-Hoon;Lim Gio-Bin
    • KSBB Journal
    • /
    • v.19 no.6 s.89
    • /
    • pp.427-432
    • /
    • 2004
  • The purpose of this study is to investigate the feasibility of a cosolvent-modified supercritical $CO_2\;(scCO_2)$ extraction technique for the production of licorice extracts with high levels of glabridin. The effects of various parameters such as the type and amount of modifiers, extraction temperature ($40{\sim}80^{\circ}C$) and pressure ($10{\sim}50.0\;MPa$) on the extraction efficiency were examined at a fixed flow rate of 1 mL/min. The organic solvent extraction with pure methanol was also conducted for a quantitative comparison with the $scCO_2$ extraction. The recovery of glabridin from licorice was found to be extremely small for pure $scCO_2$. However, the addition of modifiers such as ethanol and acetone to $scCO_2$ resulted in a significant improvement in the recovery of glabridin. The recovery of glabridin was observed to increase with pressure at a constant temperature. Furthermore, the purity of the glabridin obtained from the $scCO_2$ extraction was higher compared with the organic solvent extraction.

About Chromium (VI) Extraction from Fertilizers and Soils

  • Sager Manfred
    • Economic and Environmental Geology
    • /
    • v.38 no.6 s.175
    • /
    • pp.657-662
    • /
    • 2005
  • Extractions fro fertilizer and soil samples were performed to yield the operationally defined fractions 'soluble' chromate (extractable with $NH_4NO_3$), 'exchangeable' chromate (extractable with phosphate buffer pH 7.2), and these results were compared with the data obtained by extractions with ammonium sulfate, borate buffer pH 7.2, saturated borax pH 9.6, and polyphosphate (Graham's salt). In order to maintain the pH of extractant solution about constant, the concentration of extractant buffer had to be raised to at least 0.5 M. The results strongly depended on the kind of extractant, and the solid: liquid ratio. For most of the samples investigated, the extraction efficiency increased in the order borate-sulfate-nitrate-phosphate. Whereas the recovery of $K_2CrO_4\;and\;CaCrO_4$ added to the samples of basic slags prior to the extraction was about complete, the recovery of added $PbCrO_4$ was highly variable. In soil extracts, the color reaction was interfered from co-extracted humics, which react with the chromate in weak acid solution during the time period necessary for color reaction (1 hour). However, this problem can be overcome by standard addition and subtraction of the color of the extractant solution. In soil extract of about pH < 7, organic material reduced chromate during the extraction period also, and standard addition of soluble chromate is recommended to prove recovery and the stability of chromate in the samples. In admixtures of soils and basic slags, results for hexavalent chromium were lower than from the mere basic slags. This effect was more pronounced in phosphate than in nitrate extracts. As a proficiency test, samples low in organic carbon from contaminated sites in Hungary were tested. The results from $NH_4NO_3$ extracts satisfactorily matched the results of the Hungarian labs obtained from $CalCl_2$ extractants.