• 제목/요약/키워드: Extinction voltage

검색결과 73건 처리시간 0.031초

부분 방전에 의한 실리콘 케이블의 열화 특성에 관한 연구 (A Study on Degradation Properties of Silicone Cable due to Partial Discharge)

  • 이성일
    • 한국전기전자재료학회논문지
    • /
    • 제28권1호
    • /
    • pp.34-39
    • /
    • 2015
  • In this study, the characteristics of partial discharge was measured for the four core silicone cable (0.6/1.0 kV, $1.0SQ{\times}4C$) with insulated part of 15 cm and conductor of 1cm. The following results have been confirmed as a result of this study. When the first line of cable is connected to the positive electrode and the second, third line of cable is connected to the negative electrode, it found that the inception voltage and extinction voltage decreased with increasing the line of negative electrode, and the partial discharge charge quantity(Q) increases, while the number of discharge occurrence has decreased. The inception voltage and extinction voltage of partial discharge has decreased with increasing the degradation rate in the 33%, 67%, 100%. Also, it confirmed that the partial discharge charge quantity(Q) and the number of discharge occurrence has decreased.

Some Problems of the Partial Discharge Burning Time

  • Kinsht Nikolay V.;Katz Marat A.
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권6호
    • /
    • pp.319-323
    • /
    • 2006
  • The problem of the partial discharge (PD) extinction is investigated. The transient process takes place in a small spherical inclusion which is located in the dielectric. Both the losses caused by polarization and ohmic losses as the dielectric parameters are taken into account. From the inclusion standpoint the dielectric is considered as an active two-pole element (equivalent generator) and inclusion represents by own current-voltage curve. PD extinction voltage was shown to depend on the polarization loss tangent.

$SF_6$ 개스 중에시 wire형 도전성 입자가 절연파괴전압에 미치는 영향 (The Effect of Wire-shaped Conducting Particles on the Breakdown Voltage in Compressed $SF_6$)

  • 이동인;이형호;최병주;김영배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.258-262
    • /
    • 1988
  • Investigations were made on the effects of wire-shaped conducting particles in compressed gas chamber on breakdown voltage. The objective was to recognize the relationship between the length of wire-shaped conducting particles and a.c breakdown voltage. Also the influence of conducting particles on corona inception voltage and extinction voltage were investigated. The values of breakdown voltage and corona inception, extinction voltages were calculated by wire shaped-conducting particles lengths.

  • PDF

부분방전에 의한 주계전기의 절연성능 평가 (Insulation Performance Estimation of Main Relays by Partial Discharges)

  • 길경석;김일권;박대원;송재용;이강원;조은제
    • 한국철도학회논문집
    • /
    • 제10권4호
    • /
    • pp.388-392
    • /
    • 2007
  • A new dielectric test on main relays of electric traction vehicles, the partial discharge(PD) test, is proposed. The PD test will not affect the insulation performance of specimen during the test and provide much more detailed information on insulation, the types of defects, and so on. Insulation performance of relays is estimated by discharge inception voltage(DIV), discharge extinction voltage (DEV), and apparent charge as a function of test voltage and time. Three main relays of different manufacturing date were estimated by applying AC voltage with three patterns in ranges of $0{\sim}1,200[V]$. From the results, we could estimate insulation state and which types of defects exist in them.

고장 전압의 correlation을 이용한 2차 아크 소호 판별 (A Detection Scheme of a Secondary Arc Extinction Using Correlation of a Fault Voltage)

  • 장원혁;서훈철;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.340_341
    • /
    • 2009
  • This paper suggests a detection scheme of a secondary arc extinction using the peak value of a fault voltage estimated by correlation algorithms. The system implemented in this paper is based on a Korean 765 kV system and the suggested proposed scheme is tested on the system. The performance of the method is analyzed by using Electro-Magnetic Transients Program (EMTP)/ATPDraw.

  • PDF

대향류 확산화염의 소염특성에 미치는 직류전기장의 영향에 관한 실험적 연구 (Experimental Study on the Effect of DC Electric Field on Extinction Characteristics of Counterflow Diffusion Flame)

  • 박익형;김민국;원상희;차민석;정석호
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제33회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.253-259
    • /
    • 2006
  • The effect of DC electric fields on the flame extinction was investigated experimentally in counterflow configurations for the methane/oxygen/nitrogen diffusion flame. The electric fields was applied by connecting the high voltage and ground terminals to the upper and lower burners, respectively. In case of having electric fields, several modes of flame extinction was observed according to the electric field intensity and strain rate defined by the exit velocity. To visualize and characterize the flame structure and intensity, planar LIF technique was adopted for OH radicals. Consequently, several length scales, including the flame width, thickness, and height from the burner tip, were introduced to explain the various flame behaviors and to characterize the flame extinctions. It was found that the variation of flame width and the chemical reaction are strongly related to a critical electric field intensity, thus the various modes of diffusion flame extinction could be observed due to the electric fields.

  • PDF

접점 개방시 아크 형성과 외부자계에 의한 효과적인 아크 소호 (Forming the Are at Opening contacts and Arc Extinction by External Magnetic Force)

  • 조현길;이은웅;김준호;이화수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.699-701
    • /
    • 2003
  • This paper compare the Townsend theory with the Molten metal bridge theory of Holm for the arc discharge at opening contacts. And we measured the arc voltage at opening contacts of the 3 types arc extinction unit used in DC magnetic contactor. So, we sure that the molten metal bridge contributes to form the arc. By the experiment of the 3 types arc extinction unit, we know that the magnetic force acting on the arc doesn't effect forming arc but contribut the arc extinction.

  • PDF

765kV 1회선 선로의 2차아크 모의결과 분석 (Analysis of Simulation Results for Secondary Arc in 765kV single transmission line)

  • 안상필;김철환;박남옥;주형준;심응보
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.36-38
    • /
    • 2004
  • In many countries, including Korea, in order to transmit the more electric power, the higher transmission line voltage is inevitable. So, a rapid reclosing scheme is important for UHV transmission lines to ensure requirements for high reliability of main lines. But, because of the high voltage and long span of UHV lines, the secondary arc current flows across the fault point even after the interruption of the fault current. i.e. A critical aspect of reclosing operation is the extinction of the secondary arc since it must extinguish before successful reclosure can occur. In Korea transmission lines, it is scheduled to energize 765kV single transmission line(79km) between Sin-Ansung S/S and Sin-Gapyeong S/S at June 2006. Therefore this paper analyzes characteristics of the secondary arc extinction on 765kV single transmission line using EMTP. Simulation results shows that the average value of the secondary arc is $30A_{rms}$ and the auto-extinction time of it is longer at closer point to Sin-Gapyeong S/S.

  • PDF

다중공진 영전류 스위칭을 이용한 고주파 유도가열용 인버터 (High Frequency Inverter for Induction Heating with Multi-Resonant Zero Current Switching)

  • 라병훈;서기영;이현우;김광태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.38-40
    • /
    • 2002
  • In the case of conventional high frequency inverter, with damage of switch by surge voltage when switch gets into compulsion extinction by load accident and so on because reactor is connected by series to switch, or there was problem of conduction loss by reactor's resistivity component, Also, it has controversial point of that can not ignore conduction loss of switch in complete work kind action of soft switching. In this paper, as high frequency induction heating power supply, we propose half bridge type multi resonance soft switching high frequency inverter topology that can realize high amplitude operation of load current with controlling switch current by multiplex resonance, mitigating surge voltage when switch gets into compulsion extinction and to be complete operation of zero current switching by opposit parallel connected reactor to inverter switch. and do circuit analysis for choice of most suitable circuit parameter of circuit

  • PDF

NaCl에 의한 PVC 케이블의 부분방전 열화 특성에 관한 연구 (A Study on Partial Discharge Degradation Properties of PVC Cable due to NaCl)

  • 이성일
    • 한국전기전자재료학회논문지
    • /
    • 제28권10호
    • /
    • pp.636-641
    • /
    • 2015
  • In this study, the partial discharge degradation properties for 2-core PVC cable($2cores{\times}1.5mm^2$ cross section, length of 10 cm, 20 cm, 30 cm) following immersion with the salt water that the 2%, 4%, 8% of NaCl is dissolved in 100 g of distilled water for 48 and 96 hours has been measured. The results of this study are as follows. When the degradation time in salt water of 2% NaCl is 48 hours, it found that the number of partial discharge increased as about 40 pps, 50 pps, 90 pps with increasing the length of cable to 10 cm, 20 cm, 30 cm. In case the concentration and degradation time is same, the inception and extinction voltage decreased with increasing the length of cable. When the degradation time in salt water is 96 hours and the length of cable is 20 cm, it found that the number of partial discharge decreased as 3,000 pps, 500 pps, 100 pps with increasing the concentration of NaCl to 2%, 4%, 8%.