• Title/Summary/Keyword: External post-tensioning

Search Result 33, Processing Time 0.019 seconds

A Study on the Reinforcement of Steel Composite Beam Using the External Post-Tensioning Method (외부 후 긴장 공법을 이용한 강합성보의 보강에 관한 연구)

  • Park, Yong-Gul;Park, Young-Hoon;Lee, Seung-Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.5 s.48
    • /
    • pp.549-558
    • /
    • 2000
  • In strengthening structure, the external post-tensioning method which secure clearness in the structure analysis process is adopted to bridges as well as architecture structure. In this study, to investigate the behavior of composite beam in the process of post-tensioning, the amount of prestress force loss, the amount of prestressed compression stress at the lower flange and the behavior of lower flange connected with anchorage are analyzed by comparing the results of finite element analysis with the measured results of installed strain gauges. After finishing the post-tensioning, the strengthening effect of external post-tensioning method is analyzed by static loading test. It is also investigated that the strengthening effect of shear section in the harped external post-tensioning specimens.

  • PDF

Fiber method analysis of rc beam retrofitted with turnbuckle external post-tensioning

  • Lejano, Bernardo A.
    • Computers and Concrete
    • /
    • v.17 no.1
    • /
    • pp.67-86
    • /
    • 2016
  • Strengthening as well as correcting unsightly deflections of reinforced concrete (RC) beam may be accomplished by retrofitting. An innovative way to do this retrofitting that is proposed in this study utilizes turnbuckle to apply external post-tensioning. This Turnbuckle External Post-Tensioning (T-EPT) was experimentally proven to improve the serviceability and load carrying capacity of reinforced concrete beams. The T-EPT system comprises a braced steel frame and a turnbuckle mechanism to provide the prestressing force. To further develop the T-EPT, this research aims to develop a numerical scheme to analyze the structural performance of reinforced concrete beams with this kind of retrofitting. The fiber method analysis was used as the numerical scheme. The fiber method is a simplified finite element method that is used in this study to predict the elastic and inelastic behavior of a reinforced concrete beam. With this, parametric study was conducted so that the effective setup of doing the T-EPT retrofitting may be determined. Different T-EPT configurations were investigated and their effectiveness evaluated. Overall, the T-EPT was effective in improving the serviceability condition and load carrying capacity of reinforced concrete beam.

Shear Strengthening by Externally Post-tensioning Steel Rods in Damaged Reinforced Concrete (RC) Beams (손상입은 철근콘크리트 보의 포스트텐셔닝 강봉을 이용한 전단 보강)

  • Lee, Swoo-Heon;Lee, Hee-Du;Park, Seong-Geun;Shin, Kyung-Jae
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.1
    • /
    • pp.3-10
    • /
    • 2018
  • This experimental investigation was conducted to observe the shear strengthening behavior of pre-damaged reinforced concrete (RC) beams strengthened with externally post-tensioning steel rods. A total of six simply supported beams - two control beams and four post-tensioned beams using external steel rods - were tested to failure in shear. The external steel rods of 18 mm or 28 mm diameter were respectively employed as post-tensioning material. The four post-tensioned beams have a V-shaped profile with a deviator (or saddle pin) located at mid-span, and the post-tensioning system increased the low load-carrying capacity and overcame a little bit of deflection caused by damage. Concretely, the load-carrying capacity and flexural stiffness were respectively increased by about 25~57% and 263~387% due to the post-tensioning when compared with the unstrengthened control beams.

Reinforcement of RC Structures with External Post-Tensioning Method (외부 포스트텐셔닝공법에 의한 콘크리트 구조물의 보강사례 연구)

  • 정원용;김승익
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.387-392
    • /
    • 2002
  • In many years, post-tensioning method has been used for structural reinforcement of RC structures due to easy installation and good quality control. This study presents practical application results for the effectiveness of structural post-tensioning reinforcement of the FCM bridge girders, cement silos and building girders. For the FCM bridges deflected excessively at the end of girders, for cement silos cracked vertically at silo surface and for building girders deflected due to heavy load from roof, the external post-tensioning method was used for uplifting deflected girders and closing cracks with increasing resisting capacity of the structures. It was demonstrated that all the items were rehabilitated nearly to the initial construction status according to the field test results.

  • PDF

Strengthening of Continuous Composite Grid-girder Bridges by Using the Post-tensioning (후긴장을 이용한 연속 합성 격자형교의 보강 방법에 관한 연구)

  • Back, Dong Hoon;Lee, Woo Hyun;Kim, Ki Bong
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.441-455
    • /
    • 1997
  • The need for rehabilitation of the existing bridges is a growing concern in many countries and has been emphasized in various research reports and publications. Many bridges constructed between 1960s and 1970s in Korea were designed for relatively light traffic volumes, speeds and the weight, thus they are inadequate for the present traffic conditions. This together with some design deficiencies, has resulted in deficiencies of various degrees of many bridges. One strengthening method which has significant advantages is the application of external post-tensioning tendons. This paper presents an example of three span continuous composite bridge strenghtened by application of external post-tensioning.

  • PDF

Shear Strengthening Effect by Deviator Location in Externally Post-tensioning Reinforcement (외적 포스트텐셔닝 보강에서 데비에이터의 위치에 따른 전단보강효과)

  • Lee, Swoo-Heon;Shin, Kyung-Jae;Lee, Hee-Du
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.6
    • /
    • pp.3-10
    • /
    • 2018
  • This paper described the shear strengthening effect by deviator location in pre-damaged reinforced concrete (RC) beams strengthened with externally post-tensioning steel rods. Three reinforced concrete beams as control beam and eight post-tensioned beams using external steel rods were tested to fail in shear. The externally post-tensioning material was a steel rod of 22 mm diameter, and it had a 655 MPa yield strength and an 805 MPa tensile strength. Specimens depend on multiple variables, such as the number of deviators, location of deviator, and load pattern. The pre-damaged loads up to about 2/3 of ultimate shear capacities were applied to specimens using displacement control and the diagonal shear crack just occurred at these loading levels. And then, the post-tensioning up to when a strain of steel rod reaches about $2000{\mu}{\varepsilon}$ was continuously applied to beam. A displacement control was changed to a load control during post-tensioning. The post-tensioning resulted in increase of load-carrying capacity and restoration of existing deflection. Also, it prevented the existing diagonal cracks from excessively growing. Two deviators effectively improved the load capacity when compared with in case of test which one deviator at mid-span installed. When deviators were located near region which the diagonal crack occurred on, the strengthening impact by post-tensioning was greater.

A Study on the Effective Stress of RC Beams in Applying the Adhesion Reinforced and the External Post-Tensioning Method (RC보의 부착보강공법과 외부강선보강공법의 유효응력에 관한 연구)

  • Park, Yong-Gul;Choi, Jung-Youl;Choi, Jun-Hyeok
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.2 s.39
    • /
    • pp.186-194
    • /
    • 2007
  • This study was performed to compare the load-carrying capacities of the reinforced concrete structure between the carbon fiber adhesion reinforcement method and the external post-tensioning method and further estimate the effective stress of the reinforced material by analyzing the experimental reinforcing effect of each method and the behavior resulting from each method. As a result, it was found out that the effective stress of the carbon fiber reinforcement according to the carbon fiber adhesion reinforcement method had an unexpected value, and also, bearing of the stress was found to be far from sharing thereof. That is to say, while the carbon fiber was bearing the whole stress to some limits, it got to be momentarily ruptured as soon as it went beyond such limits. On the other hand, the external post-tensioning method has the advantage of inducing an initial effective stress by introducing a strain, and thus, it was found that behavior or bearing of the stress was also found to be a solid behavior of the steel wire. This method was also found to be more efficient and excellent than the carbon fiber adhesion reinforcement method in the reinforcing effect or securing the effective stress. Accordingly, we were to discuss the effective stress as comparatively examined, focusing on deriving of the more enhanced reinforcing effect on the basis of the experiment to which the field characteristic is added.

An Experimental Study on Thermal Prestressing Method for Strengthening Concrete Bridge (콘크리트 교량의 보강을 위한 온도 프리스트레싱 공법의 실험적 연구)

  • Ahn, Jin-Hee;Kim, Jun-Hwan;Choi, Kyu-Tae;Kim, Sang-Hyo
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.483-490
    • /
    • 2007
  • Traditional external post-tensioning method using either steel bars or tendons is commonly used as a retrofitting method for concrete bridges. However, the external post-tensioning method has some disadvantages such as stress concentration at anchorages and inefficient load carrying capability regarding live loads. Thermal prestressing method is a newly proposed method for strengthening and rehabilitation of concrete girder bridges. Founded on a simple concept of thermal expansion and contraction of steel, the method is a hybrid method of external post-tensioning and steel plate bonding, combining the merits of two methods. In this paper, basic concepts of the method are presented and an illustrative experiment is introduced. From actual experimental data, the thermal prestressing effect is substantiated and the FEM approach for its analysis is verified.

A Study on Strengthening of PSC Beam by Static Experiment - Glass fiber sheeting and External post-tensioning methods - (PSC 부재의 성능개선기법에 관한 정적 실험 연구 - 유리섬유 부착 공법과 외부 후긴장 보강 공법 -)

  • Kim, Hyun-Ho;Song, Jae-Pil;Kim, Ki-Bong;Chung, Young-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.1
    • /
    • pp.157-163
    • /
    • 2003
  • Recently, the number of Prestressed Concrete(PSC) bridges needed repair and retrofit because of the increase of heavy traffic loads and aging of concrete materials. But there are a few related researches about strengthening PSC bridges. In this study, the practicability of strengthening methods for PSC beam were studied by the static experimental method. PSC beams in length of 6m were made with concrete slabs. Glass fiber sheeting and external post-tensioning methods were used for strengthening PSC beams. Some beams were strengthened after cracks to investigate the applicability for cracked bridges. As a result, there strengthening methods were efficient at increasing the cracking loads and the failure load, to decrease deflection and prevent cracks. In the case of using glass fiber retrofit methods, it should be careful in the anchorage problems for preventing the bonding failure.

A Study on Strengthening of PSC Beam by Fatigue Experiment (피로 실험에 의한 PSC 부재의 성능개선기법에 관한 연구)

  • Kim, Hyun-Ho;Song, Jae-Pil;Kim, Ki-Bong;Chung, Young-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.1
    • /
    • pp.165-172
    • /
    • 2003
  • The fatigue problem of Prestressed Concrete(PSC) bridges are more serious than the other type of concrete bridges, because the cross sectional area and self weight of PSC bridges are smaller. The endurance of strengthening methods for PSC bridges are tested in this study. Glass fiber sheeting and external post-tensioning methods were applied. 1/5 scale PSC beams were made for fatigue test, same as static test. The range of repeated load is from 10% to 80% of yielding load with sine curve. The experimental results show that the failure cycle of strengthened members are increased compare to non-strengthened members. The members strengthened with glass fiber show better enhancement in fatigue problem than the members strengthened with external post-tensioning method, though the adhesion of glass fiber and concrete is failed, as increase of crack. With these experimental results, it can be said that the strengthening methods used in this study are efficient at extending the life time of aged PSC bridges.