• Title/Summary/Keyword: External irradiation

Search Result 241, Processing Time 0.024 seconds

Desulfurization efficiency in photobioreactors dependent on the irradiation type of light sources (광생물반응기내 광조사 유형별 탈황 효율)

  • An, Jin Young;Kim, Byung Woo
    • Clean Technology
    • /
    • v.6 no.1
    • /
    • pp.71-78
    • /
    • 2000
  • Removal rates of hydrogen sulfide were investigated to known effects of several light sources with external and internal irradiation on the desulfurization using C. thiosulfatophilum. In the case of internal illumination system, optical-fiber photobioreactor was applied to increase the light availability. Furthermore, sunlight was used as the main light energy in the daytime and metal-halide lamp was applied as an additional light energy at night. Light energy of 99% was saved by the application of the LED's array in comparison with the incandescent light source. $H_2S$ removal rates at 5,000 lux in a 4-L photobioreactor were shown as 0.040, 0.138, 0.136, and 0.134 (${\mu}mol$ $H_2S/min$)/(mg protein/L), respectively, in the following order of light sources, when several light sources such as fluorescent, energy-saving, incandescent, halogen lamp, and filtered light at 460 nm were applied. Removal rate per unit cell concentration with the internal light diffused optical-fibers increased about 1 six times as much as that with the external light sources. Removal rate per unit cell concentration, using sunlight in the daytime and a metal-halide lamp at night, was 0.41 less than 0.869 (${\mu}mol$ $H_2S/min$)/(mg protein/L) using a 400 W metal-halide lamp day and night, since the automatic sunlight collection system can transmit the light intensity as only 10% of that with a metal-halide lamp.

  • PDF

A Clinical Review of Radioactive Iodine-131 Therapy in Differentiated Thyroid Carcinoma (갑상선(甲狀線) 분화암(分化癌)의 방사성 요드-131 치료(治療)에 대한 임상적(臨庶的) 고찰(考察))

  • Park Yoon-Kyu;Lee Dae-Young;Chon Seong-Eun;Oh Sung-Soo;Chung Eul-Sam
    • Korean Journal of Head & Neck Oncology
    • /
    • v.12 no.1
    • /
    • pp.32-42
    • /
    • 1996
  • This study was desinged to evaluate the effect of radioactive iodine-131 therapy in differentiated thyroid carcinoma treated at the Presbyterian Medical Center, Chonju during the 20-year period from 1975 to 1994. The authors reviewed 246 patients who received radioactive iodine-131. An analysis of the therapeutic response and survival rates of the 246 patients has been carried out. The male to female ratio was 1 : 3.6. The peak incidence was in the 4th and 6th decades. The histologic findings in the 246 patients were papillary adenocarcinoma in 200 cases, follicular adenocarcinoma in 29 cases, mixed type in 14 cases, and others in 3 cases. Combined treatment modalities of 246 patients consisted of sugery and radioiodine in 222 cases, surgery with radioiodine and external irradiation in 11 cases, and surgery with radioiodine, external irradiation and chemotherapy in 5 cases. 42 of the 246 cases showed recurrence and the commonest type of combined treatment for recurrent case was surgery followed by radioiodine-131. The highest accumulated total dosage of radioiodine-131 was 480mCi in that case femoral metastasis was noticed. The most common locoregional metastatic site was ipsilateral cervical node, and neighbouring muscle, vessel, trachea, recurrent layngeal nerve, in order of frequency. The determinate 10-year survival rate was 91.8% in the group receiving surgery followed by radioiodine-13l and 71.4% in patients receiving surgery, radioiodine-13l with XRT. The determinate 10-year survival rate was better for patients under 40 years of age who received radioiodine as compared to patients over 40 year of age(85.7% vs. 33.3%). The most usual primary therapeutic dosage in the group of cervical lesion was 90$\sim$120mCi after surgery.

  • PDF

Transition Phenomenon from a Flat Flame to Turbulent Flame Motions by External Laser (외부 레이저에 의한 평면화염에서 난류화염거동까지의 천이현상)

  • Park, June Sung;Choi, Byung Chul;Fujita, Osamu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.12
    • /
    • pp.1209-1215
    • /
    • 2012
  • Experiments with premixed flames in a tube have been conducted to investigate the transition phenomenon from a laminar flat flame to turbulent motions. To induce this phenomenon, a flat flame is formed in a tube. Then, the local velocity at the center of the flat flame surface is increased using $CO_2$ laser irradiation. The deformed flame front propagates with an increase in the total flame surface and oscillating instability. Eventually, the flame front accelerates explosively, and it shows turbulent flame motions with a strong noise. The dynamic behaviors of the flame front prior to the turbulent motions are analyzed in this study to elucidate this process. The physical model of the process is presented according to observations.

A Study on the Combustion Characteristics of Phenol Foam (페놀 폼의 연소특성에 관한 연구)

  • Park, Hyung-Ju
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.122-127
    • /
    • 2010
  • The combustion characteristics of phenol foam were analysed using variable external irradiation level (20, 25, 35, 50, and $70kW/m^2$) and in the mixture gas of oxygen/nitrogen. The oxygen index were carried out from the oxygen index tester (KS M ISO 4589-2) and ignition time, critical heat flux, and mass loss rate were carried out from the mass loss calorimeter (ISO 5660-1). As the results of this study, the critical heat flux and average mass loss rate were $28.99kW/m^2$ and $0.56{\sim}1.77g/m^2s$ respectively at the variable external irradiation level. And the limited oxygen index were 45.1% in mixture gas of oxygen/nitrogen. In conclusion, we knew that phenol foam had the best performance than other foam materials in fire safety from all data of this study.

High Fidelity Calculation of Thermal Load in a Satellite Orbit (고정확도의 인공위성 궤도 열하중 계산 기법)

  • Kim, Min-Ki
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.10
    • /
    • pp.898-906
    • /
    • 2017
  • This paper discusses the efficient high fidelity calculation of external thermal loads of a spacecraft on its orbit. Thermal loads to a spacecraft consist of three major components, direct solar radiation, earth reflection of solar rays, and earth irradiation. With the assumption that both earth reflection and earth emission are diffuse, thermal loads from earth surface divided into pieces of segments to satellite surfaces are individually calculated and summed over. By using analytical integration of both reflected and emitted heat load by earth, high rate of numerical convergence is achieved and the results are even exactly calculated in special cases. Moreover, KD tree ray tracing is employed in the calculation of thermal load to determine whether the radiated ray is obstructed or not by satellite structure.

A Verification for Multiple Arc Stereotaxic Radiotherapy (정위 다방향 방사선조사의 선량분포를 위한 증명)

  • Yoon, Sei-Chul;Jang, Hong-Seok;Kim, In-Ah;Shinn, Kyung-Sub;Bahk, Yong-Whee
    • Radiation Oncology Journal
    • /
    • v.8 no.1
    • /
    • pp.111-114
    • /
    • 1990
  • External stereotaxic irradiation of intracranial lesions has recently gained its interest in the fields of not only radiation oncolgy but also neurosurgery. Its main goal is to deliver large doses to a relatively small target volume. Authors present methods of the stereotaxic radiosurgical irradiation using 6 MV linear accelerator (Nelac-6) and isodose distribution by therapeutic computer (Therac 2000). We attempt to demonstrate the dose distribution on verification films.

  • PDF

A nuclear battery based on silicon p-i-n structures with electroplating 63Ni layer

  • Krasnov, Andrey;Legotin, Sergey;Kuzmina, Ksenia;Ershova, Nadezhda;Rogozev, Boris
    • Nuclear Engineering and Technology
    • /
    • v.51 no.8
    • /
    • pp.1978-1982
    • /
    • 2019
  • The paper presents the electrical performance measurements of a prototype nuclear battery and two types of betavoltaic cells. The electrical performance was assessed by measuring current-voltage properties (I-V) and determining the short-circuit current and the open-circuit voltage. With 63Ni as an irradiation source, the open-circuit voltage and the short-circuit current were determined as 1 V and 64 nA, respectively. The prototype consisted of 10 betavoltaic cells that were prepared using radioactive 63Ni. Electroplating of the radioactive 63Ni on an ohmic contact (Ti-Ni) was carried out at a current density of 20 mA/㎠. Two types of betavoltaic cells were studied: with an external 63Ni source and a 63Ni-covered source. Under irradiation of the 63Ni source with an activity of 10 mCi, the open-circuit voltage Voc of the fabricated cells reached 151 mV and 109 mV; the short-circuit current density Jsc was measured to be 72.9 nA/cm2 and 64.6 nA/㎠, respectively. The betavoltaic cells had the fill factor of 55% and 50%, respectively.

Characterization of Photovoltaic Module Encapsulant According to UV Irradiation Dose (자외선 조사량에 따른 태양전지 모듈 봉지재의 특성 분석)

  • Lee, Song-Eun;Bae, Joon-Hak;Shin, Jae-Won;Jeon, Chan-Wook
    • Current Photovoltaic Research
    • /
    • v.6 no.3
    • /
    • pp.81-85
    • /
    • 2018
  • The photovoltaic modules installed in the actual field are affected by various external environments and the electrical performance output value is generally lowered compared to initial output value. The most of photovoltaic modules consists of low iron glass, encapsulant (EVA), back sheet, frame and junction box assembly based on the solar cells. In this paper, the characteristics of encapsulant which is an important constituent material of photovoltaic module were verified by maximum power determination, electro luminescence images, yellowness index measurement, and gel content measurement after ultraviolet (UV) irradiation exposure. The most commonly installed 72 cells crystalline photovoltaic modules were tested after various UV exposure of 0, 15, 30, and $60kWh/m^2$ and compared with the reference module. After UV exposure of $15kWh/m^2$, which is the current international test condition, a small amount of change was observed in yellowness index and electroluminescence, while a gell content rapidly increased. At a cumulative dose of $60kWh/m^2$, which will be a new international test condition in the near future, however, the yellowness index increased sharply and showed the greatest output power drop.

Preparation and Characterization of Acrylic Acid-grafted Poly (vinyl alcohol) Hydrogel Actuators Using γ-ray Irradiation (감마선을 이용한 아크릴산이 그라프트된 폴리비닐알코올 하이드로겔 엑츄에이터의 제조)

  • An, Sung-Jun;Lim, Youn-Mook;Gwon, Hui-Jeong;Kim, Yun-Hye;Youn, Min-Ho;Kim, Chong-Yeal;Han, Dong-Hyun;Nho, Young-Chang
    • Journal of Radiation Industry
    • /
    • v.2 no.1
    • /
    • pp.1-7
    • /
    • 2008
  • Active polymer gels expand and contract in response to certain environmental stimuli, such as the application of an electric field or a change in the pH level of the surroundings. This ability to achieve large, reversible deformations with no external mechanical loading has generated much interest in the use of these gels as biomimetic actuators and artificial muscles. In this study, poly (vinyl alcohol)(PVA) grafted acrylic acid monomer (PVA-g-AAc) hydrogels were prepared by $^{60}Co$ ${\gamma}-ray$ irradiation and their properties such as degree of grafting and weight swelling in electrostimulation as an artificial muscle and actuator were investigated.

Validation of a Model for Estimating Individual External Dose Based on Ambient Dose Equivalent and Life Patterns

  • Sato, Rina;Yoshimura, Kazuya;Sanada, Yukihisa;Sato, Tetsuro
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.2
    • /
    • pp.77-85
    • /
    • 2022
  • Background: After the Fukushima Daiichi Nuclear Power Station (FDNPS) accident, a model was developed to estimate the external exposure doses for residents who were expected to return to their homes after evacuation orders were lifted. However, the model's accuracy and uncertainties in parameters used to estimate external doses have not been evaluated. Materials and Methods: The model estimates effective doses based on the integrated ambient dose equivalent (H*(10)) and life patterns, considering a dose reduction factor to estimate the indoor H*(10) and a conversion factor from H*(10) to the effective dose. Because personal dose equivalent (Hp(10)) has been reported to agree well with the effective dose after the FDNPS accident, this study validates the model's accuracy by comparing the estimated effective doses with Hp(10). The Hp(10) and life pattern data were collected for 36 adult participants who lived or worked near the FDNPS in 2019. Results and Discussion: The estimated effective doses correlated significantly with Hp(10); however, the estimated effective doses were lower than Hp(10) for indoor sites. A comparison with the measured indoor H*(10) showed that the estimated indoor H*(10) was not underestimated. However, the Hp(10) to H*(10) ratio indoors, which corresponds to the practical conversion factor from H*(10) to the effective dose, was significantly larger than the same ratio outdoors, meaning that the conversion factor of 0.6 is not appropriate for indoors due to the changes in irradiation geometry and gamma spectra. This could have led to a lower effective dose than Hp(10). Conclusion: The estimated effective doses correlated significantly with Hp(10), demonstrating the model's applicability for effective dose estimation. However, the lower value of the effective dose indoors could be because the conversion factor did not reflect the actual environment.