• Title/Summary/Keyword: External injection

검색결과 280건 처리시간 0.024초

2.2L 직분사 디젤 엔진에서 LNT 촉매 재생을 위한 환원제 분사 방법 비교 (Comparison of the LNT Regeneration Methods in 2.2L Common Rail Direct Injection Diesel Engine)

  • 남충우;한만배
    • 한국자동차공학회논문집
    • /
    • 제23권2호
    • /
    • pp.169-177
    • /
    • 2015
  • In this study we investigated the regeneration methods for the lean $NO_x$ trap (LNT) catalyst in a 2.2L direct injection diesel engine. The regeneration methods were 1) in-cylinder post fuel injection and 2) external fuel injection strategy. The in-cylinder post fuel injection method uses in-cylinder injectors with the addition of the post fuel injection to supply enough reductants such as CO, $H_2$, THC. The external fuel injection method was enabled by installing a fuel injector with a wide spray angle before the LNT catalyst. Through the engine experiment, the $NO_x$ conversion efficiency, the amount of reductant exhaust gases, fuel consumption, and temperature behavior in the LNT catalyst were evaluated and compared for the two regeneration methods.

Characteristics of Semiconductor Laser Using Optical Injection Locking Scheme

  • Kim, Jung-Tae
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2004년도 SMICS 2004 International Symposium on Maritime and Communication Sciences
    • /
    • pp.66-69
    • /
    • 2004
  • We have investigated the spectral characteristics of semiconductor lasers locked to the external light injected from a modulated laser. The numerical model for semiconductor lasers under the external optical injection is based on the Lang's equation and has been extended in order to take into account the simultaneous injection of the multiple sidebands of the current-modulated laser. In this paper, we have analyzed characteristics of semiconductor laser using optical injection locking

  • PDF

SBR에서 아세트산을 이용한 양돈폐수의 질소·인 제거 특성 (Removal Characteristics of Nitrogen and Phosphorus in swine wastewater by Using Acetic acid on the SBR Process)

  • 허목;강진영
    • 유기물자원화
    • /
    • 제12권1호
    • /
    • pp.84-93
    • /
    • 2004
  • 본 연구는 생물학적 처리공정의 하나인 SBR을 이용하여, 양돈폐수중의 유기물과 질소, 인의 동시 제거를 목적으로 적정의 수리학적 체류시간(HRT)과 반응기간 중 교반/폭기 시간비(M/A) 및 적정의 교반/폭기 시간비에서의 외부탄소원의 주입기간(Injection Time)에 따른 변화에 따른 실험 결과로부터 다음과 같은 결론을 얻었다. (1) $NH_4{^+}-N$의 제거효율은 M/A가 0.0/22.0일 때(Run 1) 가장 효율이 좋았으며, 외부탄 소원을 주입했을 경우 탈질균의 증식으로 인해서 질산화가 잘 이루어지지 않기 때문에 주입시간이 길어질수록 증가하였다. T-N의 제거효율은 M/A가 증가할수록, 외부탄소원 주입시간이 길어질수록 증가하였다. (2) T-P의 제거효율은 운전조건에 따라 큰 차이를 보이고 있으며, M/A가 증가할수록 제거효율은 증가하였으며, 외부탄소원의 주입기간을 두고 보았을때, 주입기간을 짧게 할 경우 탈질균의 증식으로 인해서 탈질이 더 효율적으로 이루어지기 때문에 그 제거효율은 증가하였다. (3) 총 반응시간 22시간 중 M/A 16.5/5.5, 무산소 기간의 16.5시간 중 15시간동안 외부탄소원을 주입했을 경우(Run 4-1)의 운전조건에서 유기물 및 질소 제거에 가장 효율적이었다. 각각의 효율을 살펴보면, $COD_{Cr}$, $COD_{Mn}$ 그리고 $BOD_5$인 경우, 각각 90.6%, 87.7% 그리고 96.1%이고, T-N의 경우 86.6%, T-P인 경우는 84.5%로 나타났다.

  • PDF

EVALUATION OF AN ACCIDENT MANAGEMENT STRATEGY OF EMERGENCY WATER INJECTION USING FIRE ENGINES IN A TYPICAL PRESSURIZED WATER REACTOR

  • PARK, SOO-YONG;AHN, KWANG-IL
    • Nuclear Engineering and Technology
    • /
    • 제47권6호
    • /
    • pp.719-728
    • /
    • 2015
  • Following the Fukushima accident, a special safety inspection was conducted in Korea. The inspection results show that Korean nuclear power plants have no imminent risk for expected maximum potential earthquake or coastal flooding. However long- and short-term safety improvements do need to be implemented. One of the measures to increase the mitigation capability during a prolonged station blackout (SBO) accident is installing injection flow paths to provide emergency cooling water of external sources using fire engines to the steam generators or reactor cooling systems. This paper illustrates an evaluation of the effectiveness of external cooling water injection strategies using fire trucks during a potential extended SBO accident in a 1,000 MWe pressurized water reactor. With regard to the effectiveness of external cooling water injection strategies using fire engines, the strategies are judged to be very feasible for a long-term SBO, but are not likely to be effective for a short-term SBO.

THE FACTORS WHICH AFFECT THE EXTERNAL RADIATION DOSE RATE OF PET-CT PATIENTS

  • Cho, Ihn Ho;Kim, Su Jin;Han, Eun Ok
    • Journal of Radiation Protection and Research
    • /
    • 제37권4호
    • /
    • pp.231-236
    • /
    • 2012
  • This study derived measures to reduce exposure doses by identifying factors which affect the external radiation dose rate of patients treated with radiopharmaceuticals for PET-CT tests. The external radiation dose rates were measured on three parts of head, thorax and abdomen at a distance of 50cm from the surface of 60 PET-CT patients. It showed there are changes in factors affecting the external radiation dose rate over time after the administration of F-18 FDG. The external radiation dose rate was lower in the patients with more water intake than those with less water intake before the injection of radiopharmaceuticals at all three points: right after the injection of radiopharmaceuticals (average 4.17 mins), after the pre-PEET-CT urination step (average 77.47 mins), and right after the PET-CT test (average 114.15 mins). The study also found there is a need to increase the amount of water intake before the injection of radiopharmaceuticals in order to maintain a low external radiation dose rate in patients. This strategy is only possible under the assumption that the quality of the video has not changed after conducting this study on the relations between the image and quality. This study also found a need to use radiopharmaceuticals with the minimum amount needed for each patient because F-FDG doses affects the external radiation dose rate at the point right after the injection of radiopharmaceuticals. Urination frequency was the most significant factor to affect the external radiation dose rates at the point right after the PET-CT test and the point after the pre-PET-CT urination step. There is a need to realize the strategy to increase the urination frequency of patients to maintain the external radiation dose rate low (average 77.47 mins) before and after the injection of radiopharmaceuticals. In addition, at this point, there is a need to take advantage of personal strategies because the external radiation dose rate is lower if the fasting time is shorter, the contrast medium is used, and the amount of water intake is increased after the administration of radiopharmaceuticals. Finally this study found the need to be able to generalize these findings through an in-depth research on the factors affecting the external radiation dose rate, which includes radiopharmaceutical dose, urination frequency, the amount of water intake, fasting time and the use of contrast medium.

Analyses of Spectral Behaviors of Semiconductor Lasers under Weak Optical Injection Locked to External Light Injected

  • Kim, Jung-Tae
    • Journal of information and communication convergence engineering
    • /
    • 제7권4호
    • /
    • pp.556-560
    • /
    • 2009
  • We have investigated the spectral characteristics of semiconductor lasers locked to the external light injected from a modulated laser. study on FM sideband injection locking has shown that when SLs are locked to the target sidebands of the directly modulated ML, the presence of the unselected sidebands influences the resulting microwave signals. The unselected signals can produce the unwanted beat signals around the desired beat signal, which degrade the overall system performance. This analysis way to generate Giga HZ signal generation.

Design Study of an Axial Injection System for MC50 Cyclotron at KIRAMS

  • Kim, Jae-Hong;Cho, Sung-Jin;Choi, Jun-Yong;Hong, Seung-Pyo;Yu, In-Gong;Park, Hyun;Lee, Ji-Sup
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.262-262
    • /
    • 2012
  • A multi-purpose cyclotron, MC50 has been operated to provide multi-ions of proton, deuteron and alpha at Korea Institute of Radiological and Medical Sciences (KIRAMS). Neutron is also produced through the (p,n) nuclear process with a Be target. However, a wide spectrum of current of ions is requested by beam users for carrying their various application fields. Therefore a simulation study is requested on the design of an axial injection system for high current proton and alpha beam extraction for radio-isotope productions and scientific researches. The purpose of this study is seeking a relatively simple method for the MC50 having higher alpha beam capability and also improving proton and deuteron beams currently used. We are considering two possibilities to improve the internal ion source and to install a new external axial injection system. The external injection system will be consisted of an Einzel lens, a steering magnet, a buncher, and a glazer lens placed in front of an inflector, which is located at the center of the main magnet.

  • PDF

External Optical Modulator Using a Low-cost Fabry-Perot LD for Multicasting in a WDM-PON

  • Lee, Hyuek-Jae
    • Journal of the Optical Society of Korea
    • /
    • 제15권3호
    • /
    • pp.227-231
    • /
    • 2011
  • An external optical modulation using absorption s in a Fabry-Perot laser diode (FP-LD), has been proposed and experimentally demonstrated for multicasting in a WDM-PON. The center wavelengths of absorption s in an FP-LD move to short-wavelength rapidly by only a small current (~1 mA) injection. If the current injection is stopped, the s move back to the original position. Such a movement of the s can make the FP-LD act as an external optical modulator, which is found to modulate at a maximum modulation speed of 800 Mbps or more. For a multicasting transmitter in a WDM-PON, the proposed modulator can be cost-effectively applied to a multi-wavelength laser source with the same periodicity of the longitudinal mode. Instead of the multi-wavelength laser source, tunable-LDs are used for experiments. The 32 channel multicasting system with the proposed modulator has been demonstrated, showing power penalties of 1.53~4.15 dB at a bit error rate of $10^{-9}$ with extinction ratios better than 14.5 dB at 622 Mbps.

흡기관분사식 수소기관의 특성 및 역화한계당량비의 해석 (A Study on Characteristics and the Back Fire Limit Equivalnce Ratio of Hydrogen Fueled Engine with External Mixture)

  • 백성호;이종태
    • 한국수소및신에너지학회논문집
    • /
    • 제7권1호
    • /
    • pp.55-62
    • /
    • 1996
  • As an essential step for development of a duel injection hydrogen fueled engine which can obtain high thermal efficiency and power in overall operating range, performance and BFL(back fire limit) equivalance ratio in hydrogen fueled engine with external mixture are investigated. As the results, BFL equivalence ratio in hydrogen fueled engine with external mixture is approximately 0.7. It is deduced that controls of driving conditions are required in transient stage from external mixture type to inner injection type. And in order to increase thermal efficiency, it is also found that BFL equivalence ratio should be expanded as much as possible.

  • PDF

임신오조(姙娠惡阻)의 외치법(外治法)에 대한 고찰(考察) (A study on the external treatment of hyperemesis gravidarum)

  • 송병기;이경섭;임은미
    • 대한한의학회지
    • /
    • 제17권1호
    • /
    • pp.447-464
    • /
    • 1996
  • Hyperemesis gravidarum is one of the most common symptom in the early pregnancy and if it cause severe malnutrition by means of heavy vomiting as a basic sign of disease of pregnant syndrome, appropriate treatments are necessary. In the clinics the methods of treatment of hyperemesis gravidarum include herb-medication usually. But herb-medication therapy is rather difficult because during pregnancy it may cause vomiting by the smell and taste of herbs. So the author investigated the literatures referred to the external treatments of hyperemesis gravidarum excluding herb-medication and the results obtained here were as follows. 1. The external methods of treatment of hyperemesis gravidarum are various and include moxibustion, the method of applying drug at the umbilicus, ear-acupuncture method, pressure massage therapy, naso-spray method, acupoint injection, intervenous injection 2. Among the external methods of treatment of hyperemesis gravidarum , the method of applying drug at the umbilicus is most variable and almost all prescriptions use Zingiber officinalis Rose, characteristically. 3. Ear-pressure massage method to treat the hyperemesis gravidarum uses the car-acupoints of Gan, We, Shin-mun, Gyo-gam. 4. Among the external methods of treatment of hyperemesis gravidarum , moxibustion, pressure massage, and acupoint injection select frequently Nae-gwan(PC6), Chok-samni(ST36) and Chung-wan(CV12). 5. In the both the internal and external methods of treatment of hyperemesis gravidarum one have to differentiate syndromes in the viewpoint of oriental medicine and treat with the principls of treatment and prescriptions which are fit to each differentiation model under the principle of regulating the stomach and relieving vomiting.

  • PDF