• Title/Summary/Keyword: External Wind

Search Result 528, Processing Time 0.034 seconds

A Study of Strength Analysis for Nacelle Cover of 2MW Wind Turbine System (2MW 풍력발전시스템 너셀커버의 강도해석에 대한 연구)

  • Ko, Woo-Sik;Lee, Hyoung-Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.1
    • /
    • pp.20-26
    • /
    • 2008
  • The nacelle cover and nosecone are made of composite materials, especially the stiffener is added in the nacelle cover in order to enhance it's stiffness. The nacelle cover consists of all three covers of left, right side cover and upper cover and each cover is connected with bolts. Also, the nacelle cover and nacelle frame are connected with bolts. The nacelle cover and nosecone have a important role to prevent the components of nacelle and rotor from external circumstances such as snow, rain and wind. Therefore, it is necessary to analyze and evaluate the strength and deformation for them in the design level. According to GL Wind Specifications, this paper shows the results that nacelle cover of 2MW wind turbine satisfy the strength and deformation throughout analysis using Patran/Nastran programs.

Effect of Wire Bracing to Wind Load Acting on Vinyl House Frame (비닐하우스 골조에 작용하는 풍하중에 대한 강선보강효과)

  • Jung, Dong-Jo;Teng, Chhay
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.12 no.2
    • /
    • pp.23-29
    • /
    • 2010
  • Vinyl house is a simple agricultural structure that is installed economically and easily. In contrast, every year the farmers have spent a lot of money because of the collapse of this structure caused by the external forces such as strong wind and heavy snow. To prevent this damage due to frequent heavy snow and strong wind, it would be necessary to design it again. But getting rid of former vinyl house and reconstructing is unreasonable. It would be very economic if the former vinyl house is strengthened simply. This paper covers the investigation of the effect of the bracing systems that are additionally inserted inside the ordinary single frames as well as unbraced multiple frames that resisting only the strong wind load.

The Strategy of Renewable Energy of Sri Lanka for Energy-based Economic Development: Case of Wind Power

  • Han, Jong Taek;Kim, Jun Yeup
    • International Area Studies Review
    • /
    • v.21 no.1
    • /
    • pp.281-301
    • /
    • 2017
  • This article examines the way of the functionality of policy instruments for the development of renewable energy through the case of the wind power. The general barrier of the renewable energy development is considered to be the economic barrier. However the principal issue is the political barrier without the broad cooperation between the host government and the firm. Maintaining the long-term competitive advantage requires the shift of not only the strategy following the external circumstance but also the internal capacity development to utilize resources. Thus the comparative case study of Sri Lanka and Germany proposes the analysis of the supply-push and demand-pull policy with five patterns on the development of wind power in order to suggest how the functionality of policy instruments must be served to foster the wind power.

Analysis of Dynamic Response Characteristics for 5 MW Jacket-type Fixed Offshore Wind Turbine

  • Kim, Jaewook;Heo, Sanghwan;Koo, WeonCheol
    • Journal of Ocean Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.347-359
    • /
    • 2021
  • This study aims to evaluate the dynamic responses of the jacket-type offshore wind turbine using FAST software (Fatigue, Aerodynamics, Structures, and Turbulence). A systematic series of simulation cases of a 5 MW jacket-type offshore wind turbine, including wind-only, wave-only, wind & wave load cases are conducted. The dynamic responses of the wind turbine structure are obtained, including the structure displacement, rotor speed, thrust force, nacelle acceleration, bending moment at the tower bottom, and shear force on the jacket leg. The calculated time-domain results are transformed to frequency domain results using FFT and the environmental load with more impact on each dynamic response is identified. It is confirmed that the dynamic displacements of the wind turbine are dominant in the wave frequency under the incident wave alone condition, and the rotor thrust, nacelle acceleration, and bending moment at the bottom of the tower exhibit high responses in the natural frequency band of the wind turbine. In the wind only condition, all responses except the vertical displacement of the wind turbine are dominant at three times the rotor rotation frequency (considering the number of blades) generated by the wind. In a combined external force with wind and waves, it was observed that the horizontal displacement is dominant by the wind load. Additionally, the bending moment on the tower base is highly affected by the wind. The shear force of the jacket leg is basically influenced by the wave loads, but it can be affected by both the wind and wave loads especially under the turbulent wind and irregular wave conditions.

A Basic Study on the Utilization of Kitchen and Bathroom Exhaust Wind Velocity in High-Rise Apartment (초고층 공동주택의 주방.욕실 배기풍속 활용을 위한 기초연구)

  • Kim, Seong-Yong;Lee, Yong-Ho;Park, Jin-Chul;Hwang, Jung-Ha
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.226-231
    • /
    • 2011
  • This study set out to review the air current fluidity in exhaust common ducts by installing an inlet pipe at a leisure space in the PS(Pipe Shaft)room for the sake of wind power generation with kitchen and bathroom exhaust common ducts of all the equipment and air conditioning shafts in high-rise apartment. The air current functionality of kitchen and bathroom exhaust common ducts was reviewed by analyzing wind velocity changes according to changes to the area of exhaust common ducts through a simulation, changes to the wind velocity of the kitchen hood by applying an external inlet pipe, changes to the usage factor of exhaust common ducts, and changes to wind velocity by altering the form of the ventilator at the bottom of the old exhaust common duct. It was a basic study on the utilization of exhaust wind velocity in exhaust common ducts.

  • PDF

Continuation Time Integration (CTI)-Based Time Domain Simulation Analysis for Wind Farms (연속 시적분 (CTI) 기반 풍력발전단지 시모의 해석)

  • Cho, Sung-Koo;Song, Hwa-Chang;Lee, Jang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.11
    • /
    • pp.1971-1979
    • /
    • 2010
  • As a result of increasing environmental concern, the penetration of renewable power on power systems is now increasing. Wind energy can be considered as the most economical energy sources to generate electricity without depletion of fossil fuel. To devise adequate control strategies for wind farm, time domain simulation analysis needs to be performed. This presents a continuation time integration (CTI)-based time domain simulation algorithm for wind farm with doubly fed asynchronous generator (DFAG) connected to the external power systems. This paper depicts how to time trajectories are traced using CTI-based time domain simulation. Also this paper describes the possibilities of hierachical control for wind farm output limitation, and the coordinated control has been designed by hierarchical control structured from central control level to wind farm control board and to an individual wind turbine level. Finally it shows an illustrative example of time domain simulation result with two test systems through case study.

Experimental study on enhancement of drying efficiency of organic solvent using ionic wind (이온풍을 이용한 유기용매의 건조 효율 향상에 관한 실험적 연구)

  • Lee, Jae Won;Sohn, Dong Kee;Ko, Han Seo
    • Journal of the Korean Society of Visualization
    • /
    • v.17 no.1
    • /
    • pp.43-52
    • /
    • 2019
  • 'Ionic wind' is phenomenon induced by corona discharge which occurs when large electric potential is applied to electrodes with high curvature. The ionic wind has advantage that it could generate forced convective flow without any external energy like separate pump. In this study, 'pin-mesh' arrangement is utilized for experiments. First, optimization of configuration is conducted with local momentum of ionic wind behind the mesh. Empirical equation for prediction about velocity profile was derived using the measured results. Secondly, the enhancement of mass transfer rate of acetone with ionic wind was analyzed. Also, the drying efficiency using a fan which has same flow rate was compared with ionic wind for identification of additional chemical reaction. At last, the drying process of organic solvent was visualized with image processing. As a result, it was shown that the use of ionic wind could dry organic matter four times faster than the natural condition.

Analysis of Wind Pressure Characteristics of Retractable Dome Roof by Opening Type Through Wind Tunnel Test (풍동실험을 통한 개폐 유형별 개폐식 돔 지붕의 풍압 특성 분석)

  • Cheon, Dong-jin;Lee, Jong-Ho;Kim, Yong-Chul;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.21 no.1
    • /
    • pp.41-49
    • /
    • 2021
  • In this study the characteristics of wind pressure that are depending on the open type of retractable dome roof were analyzed according to the wind pressure coefficient and wind pressure spectrum. The analysis results showed that the open type and shape of the roof both had a significant impact on the wind pressure changing. In case of the edge to center open type, the wind pressure has not changed much because of the complex turbulence of flow and open area. On the other hand, in case of the center to edge open type, it has confirmed that wind pressure increases due to the separation of flow in windward and open area.

Wind Load Analysis owing to the Computation Fluid Dynamics and Wind Tunnel Test of a Container Crane (컨테이너 크레인의 전산유동해석과 풍동실험에 의한 풍하중 분석)

  • Lee, Su-Hong;Han, Dong-Seop;Han, Geun-Jo
    • Journal of Navigation and Port Research
    • /
    • v.33 no.3
    • /
    • pp.215-220
    • /
    • 2009
  • Container cranes are vulnerable structure to difficult weather conditions bemuse there is no shielding facility to protect them from strong wind. This study was carried out to analyze the effect of wind load on the structure of a container crane according to the change of the boom shape using wind tunnel test and computation fluid dynamics. And we provide a container crane designer with data which am be used in a wind resistance design of a container crane assuming that a wind load 75m/s wind velocity is applied in a container crane. In this study, we applied mean wind load conformed to 'Design Criteria of Wind Load' in 'Load Criteria of Building Structures' and an external fluid field was divided as interval of 10 degrees to analyze the effect according to a wind direction. In this conditions, we carried out the wind tunnel test and the computation fluid dynamic analysis and than we analyzed the wind load which was needed to design the container crane.

The literature study on Contact dermatitis (接觸性 皮膚炎에 關한 文獻的 考察)

  • Jeon, Jae-Hong;Kim, Hyun-A;Kang, Yun-Ho
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.10 no.1
    • /
    • pp.263-283
    • /
    • 1997
  • The study has been carried out to investigate of the Contact dermatitis by referring to 37 literature. The results were as follows; 1. In oriental medical science, Contact dermatitis is belong to the cartegory of the 'Chilchang(漆瘡)', 'Honyoja(狐尿刺)', 'Bunhwachang(粉花瘡)', 'Goyakpoong(膏藥風)', 'Matongsun(馬桶癬)'. 2. The cause of a disease is combination of internal factor-the weak of skin or the constitutional factor and external factor-the toxic substance. When the toxic substance contacts skin, pathologial change-stagnation of vital energy and blood(氣血鬱滯)-appears, and after the stagnation of vital energy and blood change heat(化火熱). 3. The symptom of a disease is topical itching, burning pain, erythematous papule, vesicle etc in skin in the acute state and itching, pachyderma, lichenification etc in skin in the chronic state. The symptom is differentiated to wind-heat(風熱) syndrom, damp-heat(濕熱) syndrom, toxic heat(熱毒) syndrom in the acute state and blood dryness(血燥) sydrom in the chronic state. 4. The treatment-methodes is as follow ; Until chung dynasty(淸代) the greater part of treatment is externl treatment The present age in china use together internal treatment and external treatment, in the acute state use method of remove heat(淸熱), remove wind(祛風), remove damp(利濕), detoxicating(解毒), remove heat from blood(凉血), in the chronic state use method of remove wind(祛風) and nourishing the blood(養血).

  • PDF