• Title/Summary/Keyword: External Trigger

Search Result 47, Processing Time 0.027 seconds

Dependence of External Magnetic Field in the Matrix-Type SFCL with the Separated or the Integrated Reactors (분리형과 일체형 리액터에 따른 매트릭스형 초전도 한류기의 외부자장 의존성 연구)

  • Cho, Yong-Sun;Choi, Hyo-Sang;Jung, Byoung-Ik;Go, Sung-Pil
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.880-884
    • /
    • 2011
  • The matrix-type superconducting fault current limiter (MSFCL) consists of the trigger and current-limiting parts. The trigger part with reactors connected in parallel improves the quenching characteristics by applying the external magnetic field into the superconducting units. The current-limiting part with superconducting units connected in parallel and shunt reactors connected in series limit the fault current when the fault occurs. We developed the integrated reactor with the trigger and the current-limiting parts to apply high external magnetic field into the superconducting units. This was composed of a superconducting unit for the trigger part and two superconducting units for the current-limiting parts. We confirmed that the external magnetic field generated in the MSFCL with an integrated reactor was larger than that of the MSFCL with the separated reactors. So the differences of voltages generated between superconducting units were decreased in the difference according to the increment of the applied voltage. The whole magnitude of the SFCL was reduced because the volume of an integrated reactor could be reduced by one-third than that of the separated reactors. We confirmed that the critical behavior between the superconducting units in the MSFCL with an integrated reactor was more improved than that of the MSFCL with the separated reactors.

The Effects of Myofascial Trigger Point Release and Mobility Exercise on Pain and Functions in Patient with Rotator Cuff Tendinopathy

  • Shin, Beom-Cheol;Choi, Wonjae;Jung, Jihye;Lee, Seungwon
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.2
    • /
    • pp.269-278
    • /
    • 2022
  • Objective: The aim of this study was to evaluate the effects on pain and function of patients with rotator cuff tendinopathy when applying trigger point of infraspinatus and teres minor to myofascial trigger point release (MFR) plus mobility exercise and MFR. Design: A randomized controlled trial. Methods: The total participants were 30patients and were separated to MFR plus mobility exercise group(n=15) and MFR group (n=15) according to the randomized treatment method. The MFR was performed at two infraspinatus tampon points and one teres minor tampon point for twice a week for 4 weeks and the treatment time was 6 minutes 20 seconds in each position. The MFR group also carried out the myofascial trigger point release in the same way as the MFR plus mobility exercise group. Results: The MFR plus mobility exercise group significantly reduced objective and subjective pain (p<0.05). The range of motion of the shoulder joint flexion and external rotation, Quick-Disability of the Arm, shoulder and Hand, and Shoulder Pain and Disability Index were significantly improved in the group to which MFR plus mobility exercise was applied (p<0.05). Conclusions: These results confirmed that MRF plus mobility exercise is more effective in relieving shoulder pain and improving function in rotator cuff tendinopathy.

New Thyristor Based ESD Protection Devices with High Holding Voltages for On-Chip ESD Protection Circuits

  • Hwang, Suen-Ki;Cheong, Ha-Young
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.2
    • /
    • pp.150-154
    • /
    • 2019
  • In the design of semiconductor integrated circuits, ESD is one of the important issues related to product quality improvement and reliability. In particular, as the process progresses and the thickness of the gate oxide film decreases, ESD is recognized as an important problem of integrated circuit design. Many ESD protection circuits have been studied to solve such ESD problems. In addition, the proposed device can modify the existing SCR structure without adding external circuit to effectively protect the gate oxide of the internal circuit by low trigger voltage, and prevent the undesired latch-up phenomenon in the steady state with high holding voltage. In this paper, SCR-based novel ESD(Electro-Static Discharge) device with the high holding voltage has been proposed. The proposed device has the lower triggering voltage without an external trigger circuitry and the high holding voltage to prevent latch-up phenomenon during the normal condition. Using TCAD simulation results, not only the design factors that influence the holding voltage, but also comparison of conventional ESD protection device(ggNMOS, SCR), are explained. The proposed device was fabricated using 0.35um BCD process and was measured electrical characteristic and robustness. In the result, the proposed device has triggering voltage of 13.1V and holding voltage of 11.4V and HBM 5kV, MM 250V ESD robustness.

Fabrication and test of heater triggered persistent current switch using coated conductor tapes (Coated conductor를 이용한 히터트리거 방식의 영구전류 스위치의 제작과 실험)

  • Kim, Young-Jae;Yang, Seong-Eun;Park, Dong-Keun;Ahn, Min-Cheol;Yoon, Yong-Soo;Ko, Tae-Huk
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2039-2040
    • /
    • 2006
  • Persistent current switch (PCS) system in NMR, MRI, MAGLEV and SMES has many advantages, such as uniformity and durability of magnetic field and reducing a thermal loss, which enable many superconducting application to operate effectively. This paper deals with fabrication and test of heater trigger persistent current switch using coated conductor (CC) which has high n-index, critical current independency from external magnetic field and adaptable selectivity of stabilizer. PCS system consists of magnet power supply for energizing current to a magnet, heater, switch and magnet using coated conductor tape. Finite element method (FEM) is used to simulate thermal quench (switching) characteristic and design heater trigger. With FEM simulation, optimal length of heater is calculated by temperature and time analysis. Fabrication of PCS system and test of heater trigger characteristic were performed and compared with simulation result. This paper would be the foundation of researches of superconducting switching application.

  • PDF

Analysis on the quenching characteristics of a superconducting fault current limiter with 2 by 3 matrixes ($2{\times}3$행렬구조를 갖는 초전도 한류기의 퀜치특성 분석)

  • Cho, Yong-Sun;Park, Hyoung-Min;Lee, Ju-Hyoung;Jung, Byung-Ik;Choi, Hyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2210-2211
    • /
    • 2008
  • In this paper, we investigated the quenching characteristics of a superconducting fault current limiter (SFCL) with connection of $2{\times}3$ matrixes. This SFCL consists of the trigger part to apply magnetic field and the current-limiting part to limit the fault current. When the fault occurs, the magnetic field generated in the reactor connected in parallel was applied to the two superconducting units of the current-limiting part to reduce of inhomogeneous critical current behavior between the superconducting units. The quenching behavior of a superconducting unit in the trigger part was affected by the increase of turn numbers. This is because of the difference of current distribution between the inductance of the reactors and the resistance generated in the superconducting units in trigger part. We confirmed that the voltage differences between two superconducting units of the current-limiting part were decreased. This is because of the improvement of inhomogeneous critical current behavior between the superconducting units according to the increase of external magnetic field.

  • PDF

Development of Defect Inspection System for Polygonal Containers (다각형 용기의 결함 검사 시스템 개발)

  • Yoon, Suk-Moon;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.25 no.3
    • /
    • pp.485-492
    • /
    • 2021
  • In this paper, we propose the development of a defect inspection system for polygonal containers. Embedded board consists of main part, communication part, input/output part, etc. The main unit is a main arithmetic unit, and the operating system that drives the embedded board is ported to control input/output for external communication, sensors and control. The input/output unit converts the electrical signals of the sensors installed in the field into digital and transmits them to the main module and plays the role of controlling the external stepper motor. The communication unit performs a role of setting an image capturing camera trigger and driving setting of the control device. The input/output unit converts the electrical signals of the control switches and sensors into digital and transmits them to the main module. In the input circuit for receiving the pulse input related to the operation mode, etc., a photocoupler is designed for each input port in order to minimize the interference of external noise. In order to objectively evaluate the accuracy of the development of the proposed polygonal container defect inspection system, comparison with other machine vision inspection systems is required, but it is impossible because there is currently no machine vision inspection system for polygonal containers. Therefore, by measuring the operation timing with an oscilloscope, it was confirmed that waveforms such as Test Time, One Angle Pulse Value, One Pulse Time, Camera Trigger Pulse, and BLU brightness control were accurately output.

Magnetic-Shielding Effectiveness Analysis of the Trigger Assembly of Small Arms (소구경 개인화기 격발신호 발생장치의 자기차폐효과 분석)

  • Lee, Kisu;Ahn, Joon Mo;Chae, Je-Wook
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.456-463
    • /
    • 2018
  • With the development of weapon systems by mounting various sensors, it makes important to analyze the precise functioning of sensor to external environment. In the case of small arms with magnetic sensor, the malfunction of small arms might be caused by strong external magnetic fields. In this study, the effects of magnetic sensor on external magnetic fields were analyzed, and optimal magnetic shield and shield structure were designed through M&S. In addition, the magnetic-shielding effectiveness of magnetic sensor in small arms was verified with commercial shielding materials. As a result, it was demonstrated that the Fe-Cu-Si-Nd-B with the structure of multi-layer metallic shields was shown the magnetic-shielding effectiveness of 83 % for an external permanent magnet and 19 % for an alternating magnetic field of 180 dBpT at 60 Hz, respectively.

A Characteristic Analysis of Heater Triggered Persistent Current System with 2G High Tc Superconducting Tape (차세대 고온초전도 선재를 이용한 영구전류시스템의 히터트리거 특성 해석)

  • Park, Dong-Keun;Kang, Hyoung-Ku;Yang, Seong-Eun;Ahn, Min-Cheol;Yoon, Yong-Soo;Yoon, Kyung-Yong;Lee, Sang-Jin;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1228-1230
    • /
    • 2005
  • This paper deals with design of heater trigger switching in a persistent current system(PCS) by finite element method(FEM) analysis of YBCO coated conductor(CC) tape. Most promising superconducting wire is YBCO coated conductor tape in these days for its high n value and critical current independency from external magnetic field. It is expected to be used many superconducting application such as fault current limiter and cable etc. The superconducting magnet which is operated in persistent current mode in SMES, NMR, MRI and MAGLEV has many advantages such as a high uniformity of a magnetic field and reducing a thermal loss. A PCS system consists of magnet power supply (MPS) which energized current to a magnet, heater, a coated conductor tape for switching, and superconducting magnet. In this paper, the characteristic of thermal quench of the YBCO CC tape and BSCCO tape by heater trigger analyzed by FEM. And optimal length of heater is calculated by temperature and time analysis. This heater trigger analysis is expected to be a basic concept of PCS application design.

  • PDF

The Effect of Vividness of Preannounced New Product Information on e-WOM in Internet Community and Intention of Internet Posting (프리어나운싱 된 신제품 정보의 생동감이 인터넷커뮤니티 유저의 e-WOM와 인터넷 포스팅의도에 미치는 영향)

  • Song, Yong-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.2
    • /
    • pp.312-321
    • /
    • 2011
  • Recently, lots of corporations take effect preannouncing activity before launching new product as communication strategy. Preannouncing information of new product is diffused in internet community which relate to the product. This study notes the effect of external vividness and internal vividness among information characteristics of new product to e-WOM(electronic word-of-mouth). The author aims to identify how to trigger intention of e-WOM on preannounced new products, and external vividness and internal vividness of determinants of e-WOM and intention of internet posting. The main findings are that external vividness and internal vividness positively influence e-WOM in internet community, and the e-WOM positively affects intention of internet posting.