Design of Multipurpose Phantom for External Audit on Radiotherapy

  • Lim, Sangwook
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.122-129
    • /
    • 2021
  • Purpose: This study aimed to design a multipurpose dose verification phantom for external audits to secure safe and optimal radiation therapy. Methods: In this study, we used International Atomic Energy Agency (IAEA) LiF powder thermoluminescence dosimeter (TLD), which is generally used in the therapeutic radiation dose assurance project. The newly designed multipurpose phantom (MPP) consists of a container filled with water, a TLD holder, and two water-pressing covers. The size of the phantom was designed to be sufficient (30×30×30 cm3). The water container was filled with water and pressed with the cover for normal incidence to be fixed. The surface of the MPP was devised to maintain the same distance from the source at all times, even in the case of oblique incidence regardless of the water level. The MPP was irradiated with 6, 10, and 15 MV photon beams from Varian Linear Accelerator and measured by a 1.25 cm3 ionization chamber to get the correction factors. Monte Carlo (MC) simulation was also used to compare the measurements. Results: The result obtained by MC had a relatively high uncertainty of 1% at the dosimetry point, but it showed a correction factor value of 1.3% at the 5 cm point. The energy dependence was large at 6 MV and small at 15 MV. Various dosimetric parameters for external audits can be performed within an hour. Conclusions: The results allow an objective comparison of the quality assurance (QA) of individual hospitals. Therefore, this can be employed for external audits or QA systems in radiation therapy institutions.

일간 빔 출력 확인을 위한 평가도구인 Machine Performance Check의 유용성 평가 (Assessment of the usefulness of the Machine Performance Check system that is an evaluation tools for the determination of daily beam output)

  • 이상현;안우상;이우석;최진혁;김선연
    • 대한방사선치료학회지
    • /
    • 제29권2호
    • /
    • pp.65-73
    • /
    • 2017
  • 목 적: Machine Performance Check (MPC)는 Electronic Portal Imaging Device(EPID)를 기반으로 빔 출력을 별도의 설치 없이 측정할 수 있는 장점을 지닌 자체 검사 소프트웨어이다. 본원에서는 MPC와 QA Beamchecker PLUS 간의 일간 빔 출력을 비교 및 상관관계를 분석하여 MPC의 유용성을 확인하고자 하였다. 대상 및 방법: 본 실험을 진행하기 위해 선형가속기(Truebeam 2.5)를 이용하였고, 광자선(6 MV, 10 MV, 15 MV, 6 MV-FFF, 10 MV-FFF), 전자선(6 MeV, 9 MeV, 12 MeV, 16 MeV, 20 MeV) 총 10개의 에너지를 대상으로 5 개월간 치료 전 빔 출력을 MPC와 QA Beamchecker PLUS로 측정하여, 총 80 회의 데이터를 획득하였다. Pearson 상관계수를 사용하여 MPC와 QA Beamchecker PLUS 간의 빔 출력을 비교 및 상관관계를 평가하였다. Pearson 상관계수는 0.8 이상은 아주 강함, 0.6 이상 0.8 미만 강함, 0.4 이상 0.6 미만 보통, 0.2 이상 0.4 미만 약함, 0.2 미만 아주 약함을 의미한다. 결 과: MPC와 QA Beamchecker PLUS 모두 일간 빔 출력 일치도는 2 % 이내로 나타났다. MPC의 빔 출력은 광자선이 $0.29{\pm}0.26%$, 전자선이 $0.30{\pm}0.26%$로 나타났고, QA Beamchecker PLUS의 빔 출력은 광자선이 $0.31{\pm}0.24%$, 전자선이 $0.33{\pm}0.24%$로 나타났다. MPC와 QA Beamchecker PLUS 사이의 Pearson 상관계수는 광자선의 경우 15 MV에서는 아주강함, 6 MV, 10 MV, 6 MV-FFF 그리고 10 MV-FFF에서는 강함으로 나타났고, 전자선의 경우 16 MeV, 20 MeV에서 강함, 9 MeV, 12 MeV에서 보통, 6 MeV에서 아주 약함으로 나타났다. 결 론: MPC는 일간 빔 출력 평가 면에서 광자선과 고에너지 전자선에서는 QA Beamchecker PLUS와 강한 상관관계로 보임을 확인할 수 있었다. 다만, 저에너지 전자선(6 MeV)에서는 낮은 상관관계를 보였지만, 관찰기간동안 MPC, QA Beamchecker PLUS 모두 빔 출력 일치도는 2 % 이내로 일간 빔 출력 확인 용도로는 적절할 것으로 판단된다. MPC는 기존의 일간 빔 출력 측정 도구 보다 빠르게 수행 할 수 있어 사용자 입장에서 효과적인 방법인 것으로 사료된다.

  • PDF

Investigation on Individual Variation of Organ Doses for Photon External Exposures: A Monte Carlo Simulation Study

  • Yumi Lee;Ji Won Choi;Lior Braunstein;Choonsik Lee;Yeon Soo Yeom
    • Journal of Radiation Protection and Research
    • /
    • 제49권1호
    • /
    • pp.50-64
    • /
    • 2024
  • Background: The reference dose coefficients (DCs) of the International Commission on Radiological Protection (ICRP) have been widely used to estimate organ doses of individuals for risk assessments. This approach has been well accepted because individual anatomy data are usually unavailable, although dosimetric uncertainty exists due to the anatomical difference between the reference phantoms and the individuals. We attempted to quantify the individual variation of organ doses for photon external exposures by calculating and comparing organ DCs for 30 individuals against the ICRP reference DCs. Materials and Methods: We acquired computed tomography images from 30 patients in which eight organs (brain, breasts, liver, lungs, skeleton, skin, stomach, and urinary bladder) were segmented using the ImageJ software to create voxel phantoms. The phantoms were implemented into the Monte Carlo N-Particle 6 (MCNP6) code and then irradiated by broad parallel photon beams (10 keV to 10 MeV) at four directions (antero-posterior, postero-anterior, left-lateral, right-lateral) to calculate organ DCs. Results and Discussion: There was significant variation in organ doses due to the difference in anatomy among the individuals, especially in the kilovoltage region (e.g., <100 keV). For example, the red bone marrow doses at 0.01 MeV varied from 3 to 7 orders of the magnitude depending on the irradiation geometry. In contrast, in the megavoltage region (1-10 MeV), the individual variation of the organ doses was found to be negligibly small (differences <10%). It was also interesting to observe that the organ doses of the ICRP reference phantoms showed good agreement with the mean values of the organ doses among the patients in many cases. Conclusion: The results of this study would be informative to improve insights in individual-specific dosimetry. It should be extended to further studies in terms of many different aspects (e.g., other particles such as neutrons, other exposures such as internal exposures, and a larger number of individuals/patients) in the future.

한국의학물리학회 선형가속기 외부 품질관리 실시 현황보고 (Report on the External Audits Conducted by Korean Society of Medical Physics)

  • 허현도;조광환;조삼주;최상현;김동욱;황의중;김기환;민철기;최태진;오영기;이승준;박달;박성광;지영훈
    • 한국의학물리학회지:의학물리
    • /
    • 제24권4호
    • /
    • pp.315-322
    • /
    • 2013
  • 전문가 그룹의 외부검사를 통하여 의료기관 자체적으로 시행되고 있는 품질관리를 평가하고 구조적 문제점에 대한 상호보완을 하고자 하였다. 외부 검사의 정당성 확보를 위해 전국 80여 개의 의료기관 중 지역 분포를 고려하여 30여 개를 선정하였고, 최종 25개의 의료기관이 자발적 참여의사를 신청하였다. 참여의료기관은 비공개를 원칙으로 하였고, 사전에 상호 비교하여 검증된 측정 장비를 가지고 직접 방문하여 측정하는 것을 원칙으로 하였다. 두 개 이상의 광자선을 대상으로 출력선량을 측정하였고, 갠트리회전 정확도, 콜리메이터 회전 정확도, 다엽콜리메이터 이동 위치 정확도 등을 측정하였다. 출력선량 측정에서 6 MV의 경우 -0.8%~4.5%까지 절대오차를 보였고, 10 MV의 경우 -0.79%~3.01%이었고, 15 MV에서 -0.7%~0.07% 절대오차를 나타내었다. 25개 의료 기관을 대상으로 한 50개의 광자선 중에서 절대 흡수선량이 2% 이상 되는 에너지가 8개(16%)로 나타났다. 조사면과 갠트리, 콜리메이터 회전축 일치도는 2개 의료기관을 제외하고 모두 ${\pm}2$ mm 이내의 결과를 보였다. 다엽콜리메이터 이동 위치 정확도는 모두 ${\pm}1$ mm 이내의 정확도를 보였다. 에너지 선질 조사에서 광자선 6 MV의 경우 KQ 값의 최고값과 최저값의 차이는 0.4%로 나타났다. 물 흡수선량 기반 측정 기준서 사용기관은 21개(84%), 공기 흡수선량 기반 측정 기준서 사용기관은 4개(16%)로 조사되었고, SSD 측정법을 사용하는 기관은 22개, SAD 측정법을 사용하는 기관은 3개 기관으로 조사되었다. 외부검사는 자체적으로 시행되고 있는 품질관리의 구조적인 문제점을 찾아 상호 보완하는 것임으로 매우 중요하다. 따라서 전문가 그룹 및 국가가 함께 주기적이고, 지속적인 외부검사가 시행 될 수 있도록 국제 수준의 전문가의 양성 및 국가지원 제도가 필요하다고 사료된다.

Organ Dose Conversion Coefficients Calculated for Korean Pediatric and Adult Voxel Phantoms Exposed to External Photon Fields

  • Lee, Choonsik;Yeom, Yeon Soo;Griffin, Keith;Lee, Choonik;Lee, Ae-Kyoung;Choi, Hyung-do
    • Journal of Radiation Protection and Research
    • /
    • 제45권2호
    • /
    • pp.69-75
    • /
    • 2020
  • Background: Dose conversion coefficients (DCCs) have been commonly used to estimate radiation-dose absorption by human organs based on physical measurements of fluence or kerma. The International Commission on Radiological Protection (ICRP) has reported a library of DCCs, but few studies have been conducted on their applicability to non-Caucasian populations. In the present study, we collected a total of 8 Korean pediatric and adult voxel phantoms to calculate the organ DCCs for idealized external photon-irradiation geometries. Materials and Methods: We adopted one pediatric female phantom (ETRI Child), two adult female phantoms (KORWOMAN and HDRK Female), and five adult male phantoms (KORMAN, ETRI Man, KTMAN1, KTMAN2, and HDRK Man). A general-purpose Monte Carlo radiation transport code, MCNPX2.7 (Monte Carlo N-Particle Transport extended version 2.7), was employed to calculate the DCCs for 13 major radiosensitive organs in six irradiation geometries (anteroposterior, posteroanterior, right lateral, left lateral, rotational, and isotropic) and 33 photon energy bins (0.01-20 MeV). Results and Discussion: The DCCs for major radiosensitive organs (e.g., lungs and colon) in anteroposterior geometry agreed reasonably well across the 8 Korean phantoms, whereas those for deep-seated organs (e.g., gonads) varied significantly. The DCCs of the child phantom were greater than those of the adult phantoms. A comparison with the ICRP Publication 116 data showed reasonable agreements with the Korean phantom-based data. The variations in organ DCCs were well explained using the distribution of organ depths from the phantom surface. Conclusion: A library of dose conversion coefficients for major radiosensitive organs in a series of pediatric and adult Korean voxel phantoms was established and compared with the reference data from the ICRP. This comparison showed that our Korean phantom-based data agrees reasonably with the ICRP reference data.

고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐 (Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy)

  • 추성실;서창옥;김귀언
    • Journal of Radiation Protection and Research
    • /
    • 제27권1호
    • /
    • pp.1-10
    • /
    • 2002
  • 의료용 선형가속기에서 발생되는 고 에너지 광자선은 콜리메이터에 의하여 누출되며 치료두부(head), 콜리메이터, 환자를 포함한 치료실내의 모든 벽과 구성 물질들에 의하여 많은 산란선이 발생된다. 방사선치료는 종양에 따라서 최소한 40 Gy에서 80 Gy까지 조사되기 때문에 주위건강조직 특히 생식가능한 사람에 대한 생식선의 피폭선량을 평가하여야하며 종양치료에 영향을 주지 않은 범위에서 가능한 방법을 동원하여 피폭선량을 줄여야한다. 방사선 안전관리등의 기술기준에 관한 규칙(과학기술부령 제17호) 제3절 의료분야의 특별기준, 제44조(진료환자의 방사선 피폭)에 의하면 진료를 위한 환자 피폭선량을 합리적으로 달성 가능한 최소의 수준으로 유지하기 위한 절차를 구비하여야 하며 과학기술부 장관은 이에 준하는 의료시설 및 장비취급의 기술기준을 정하고 고시하여야한다고 명시 되어있다. 고 에너지방사선은 악성종양환자들의 치료성과를 향상시키는 동시에 치료후 방사선에 의한 만성효과가 발생 될 수 있기 때문에 주선속의 다양한 산란선과 누출선의 선질변화와 선량을 측정하고 생식선과 같은 주요장기를 산란선으로부터 차폐할 수 있는 기구를 제작 사용함으로서 방사선 피폭선량을 최대한으로 감소시킬 수 있었다. 고 에너지 방사선은 의료용 선형가속기(CLINAC 2100C/D. 2100C. 600C)에서 발생시킨 4, 6, 10 MV x-ray와 코발트원격치료장치(ALCYON II)의 코발트선원에서 방출되는 1.25 MV의 감마선을 이용하였다. 선량측정은 폴리스틸렌과 인체팬텀(Rando)사용하였으며 측정기는 이온함, TLD 및 필름을 사용하였다. 고 에너지 방사선에 의한 산란선은 장치의 콜리메이터 뿐만 아니라 치료실 벽 인체내부등 모든 방향에서 방사됨으로 납 벽돌에 의한 차폐율측정은 많은 변수를 가졌으며 고환인 경우에는 3면이 모두 차폐되도록 항아리모양으로 제작하였다. 태아인 경우 태아가 위치하고 있는 골반위에 육교모양의 선반을 만들고 그 위에 납 벽돌을 장치하도록 고안하였다. Co-60 감마선, 4 MV x-선, 10 MV x-선에서 발생되는 누출선량과 산란선량에 의한 평균 피폭선량은 조사면 중심으로부터 10, 30, 60cm 거리에서 조사면내 최대선량에 대하여 각각 $10^{-2},\;10^{-3},\;10^{-4}$의 비율로 측정되었으며 거리에 따라 지수함수로 줄어들었다. 흉부에 국한된 종양을 10 MV x-ray, $12{\times}12 cm^2$ 조사면으로 치료하였을 때 자궁에 받는 피폭선량은 0.9 mGy/Gy이며 고환이 받는 피폭선량은 0.6 mGy/Gy 이었으며 체장과 신장은 각각 4.8 mGy/Gy 와 2.5 mGy/Gy이다 10 MV x-선, $14{\times}14cm^2$ 조사면 경계로부터 10 cm 밖에서 납벽돌의 반가층 두께는 약 9.0 mm 이였고 20cm 밖에서는 반가층 두께가 약 6.5 mm로 측정되었다. 복부에 위치한 악성종양을 60 Gy 조사하였을 경우 태아가 위치하고 있는 자궁의 피폭선량은 약 370 mGy이고 이곳을 10 mGy이하가 되도록 차폐하려면 약 6.2 cm두께의 납 벽돌을 자궁위에 장착하여야 하며 골반치료시 고환에 10 mGy이하가 되도록 차폐하려면 약 5 cm 두께의 납 항아리가 요구된다. 고 에너지 고 준위 방사선치료시 고환은 3면을 항아리모양으로 차폐할 수 있어 피폭선량을 상당히 줄일 수 있으며 자궁인 경우 체내에서 산란된 선량의 차폐는 불가능하였다.

고체팬텀을 이용한 국내 방사선 치료시설의 흡수선량에 대한 조사 (External Auditing on Absorbed Dose Using a Solid Water Phantom for Domestic Radiotherapy Facilities)

  • 최창헌;김정인;박종민;박양균;조건우;조운갑;임천일;예성준
    • Radiation Oncology Journal
    • /
    • 제28권1호
    • /
    • pp.50-56
    • /
    • 2010
  • 목 적: 제 3기관에 의해 독립적으로 수행된 방사선 치료 빔의 흡수 선량을 외부 감사의 결과로 보고 한다. 이를 위해 쉽고 편리하게 설치 가능 한 고체 팬텀을 이용하여 흡수 선량을 측정하는 방법을 개발했다. 대상 및 방법: 2008년 12개 방사선 치료 시설에서 외부 감사 프로그램에 참여하였고 47개의 광자선과 전자선의 제 3기관에 의해 American Association of Physicists in Medicine (AAPM) task group (TG)-51 프로토콜을 사용하여 독립적으로 교정되었다. AAPM TG-51 프로토콜은 물에서의 측정을 권고 하고 있지만 팬텀으로 물은 바쁜 병원 상황에선 몇 가지 단점이 있다. 설치와 수송이 편리하고 재현성이 있는 고체 팬텀을 사용하였다. 광자선과 전자선에 대한 물과 고체 팬텀 사이의 선량 보정인자는 스케일링 방법과 실험적 측정에 의해 결정되었다. 결 과: 대부분의 빔은(74%) 제3기관의 프로토콜로 측정한 결과 2%의 편차 이내였다. 그러나 20개 중 2개의 광자선과 27개 중 3개의 전자선은 허용범위(3%)를 초과 하였다. 특히 그중 2개의 빔은 10% 이상의 편차를 보여주고 있다. 6 MV 초과의 고에너지 광자선은 보정인자가 없었다. 6 MV 광자선의 경우 고체 팬텀에서의 흡수선량은 물에서의 흡수 선량보다 0.4% 작게 나타났다. 전자선에 대한 보정인자도 결정되었는데 전자선의 에너지가 증가함에 따라 보정인자는 작아지는 경향을 보여준다. 고체팬텀을 사용한 TG-51 프로토콜의 측정 오차는 ${\pm}1.22%$로 나타났다. 결 론: 개발된 방법은 다기관 임상 연구의 인증 프로그램에 참여할 수 있는 외부 감사 기관 프로그램에 성공적으로 적용되었다. 이 선량측정은 선량을 측정하기 위한 시간을 줄이고 물을 설치할 때의 생길 수 있는 측정오차를 감소시킨다.

Proton Beam Dosimetry Intercomparison

  • Fukumura, Akifumi;Kanai, Tatsuaki;Kanematsu, Nobuyuki;Yusa, Ken;Maruhashi, Akira;Nohtomi, Akihiro;Nishio, Teiji;Shimbo, Munefumi;Akagi, Takashi;Yanou, Toshihiro;Fukuda, Shigekazu;Hasegawa, Takashi;Kusano, Yohsuke;Masuda, Yasutaka
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.252-254
    • /
    • 2002
  • A new protocol for dosimetry in external beam radiotherapy is published by the Japan Society of Medical Physics (JSMP) in 2002. The protocol deals with proton and heavy ion beams as well as photon and electron beams, in accordance with IAEA Technical Report Series No. 398. To establish inter-institutional uniformity in proton beam dosimetry, an intercomparison program was carried out with the new protocol. The absorbed doses are measured with different cylindrical ionization chambers in a water phantom at a position of 30-mm residual range for a proton beam, that had range of 155 mm and a spread out Bragg peak (SOBP) of 60-mm width. As a result, the intercomparison showed that the use of the new protocol would improve the +/- 1.0 % (one standard deviation) and 2.7 % (maximum discrepancy) differences in absorbed doses stated by the participating institutions to +/- 0.3% and 0.9 %, respectively. The new protocol will be adopted by all of the participants.

  • PDF

한국 성인남성 MIRD형 모의피폭체 제작 및 광자 외부피폭 선량환산인자 산출 (Construction of MIRD-type Korean Adult Male Phantom and Calculation of Dose Conversion Coefficients for Photon)

  • 박상현;이춘식;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제29권2호
    • /
    • pp.97-104
    • /
    • 2004
  • 한국인 고유의 방사선 방호량을 산출하기 위한 목적으로 MIRD형 한국 성인남성 모의피폭체 'KMIRD'를 제작하였다. 모의 피폭체의 외형은 국민표준체위조사에서 제공하는 데이터를 사용하여 제작하였다. 제작된 KMIRD는 MIRDS보다 몸통 두께가 더 두껍고, 팔이 첨가되었다. 보건연구원에서 제공하는 9개 장기의 한국표준 자료와 ICRP23의 자료를 사용하여 모의피폭체의 내부 장기를 모사하였다. KMIRD의 신장은 171 cm, 체중은 63.8 kg이다. 제작된 KMIRD와 몬테칼로 입자 수송 코드인 MCNPX2.3을 이용하여 0.05와 10 MeV 사이의 7개 에너지 영역에 대해서 광자의 선량환산인자를 산출하였다. 피폭 환경은 AP, PA, LLAT, RLAT 4가지 방향에서 입사하는 평행하고 넓은 광자 방사선장으로 모사하였다. ICRP23 표준인 자료를 기초로 제작된 MIRD5 모의 피폭체를 사용하여, 비교 계산을 수행하였다. 장기별 흡수선량환산계수를 비교한 결과 30% 이상의 차이를 보이는 장기도 있었다. 유효선량 환산계수를 비교한 결과, 모든 입사 방향에서 KMIRD가 MIRD5보다 낮은 값을 보였다. 한국인과 서구인간의 체격적인 차이와, 모의피폭체간치 기하학적 구조의 차이가 선량 편차의 주요 원인이다. 모든 장기에 대한 한국 표준자료를 확보하여 개선된 한국인 MIRD형 모의 피폭체를 제작해야한다. KMIRD를 사용하여 내부피폭 선량평가를 수행할 수 있다.

체적소팬텀과의 장기선량 비교를 통한 MIRD팬텀 몸통두께 수정 (Modification of Trunk Thickness of MIRD phantom Based on the Comparison of Organ Doses with Voxel Phantom)

  • 이춘식;박상현;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제28권3호
    • /
    • pp.199-206
    • /
    • 2003
  • 대표적인 수학적 팬텀인 MIRD팬텀은 개발 당시 컴퓨터 계산시간을 단축하기 위해 단순화된 수학방정식으로 표현되었으며 본래 내부피폭 선량계산에 이용하기 위해 제작되었으므로 실제 인체구조에 근접하는 정도와 외부피폭 선량계산 용도로서의 적합성 여부를 평가할 필요가 있다. 본 연구에서는 인체의 단층촬영영상을 이용하여 제작된 Zubal 체적소팬텀과 MERD팬텀이 가장 일반적인 피폭모드인 AP 및 PA모드 감마선장에 노출될 때 장기선량 계산결과 및 단층영상을 비교하여 선량차이의 주요 원인이 되는 MIRD팬텀의 몸통두께를 수정하였다. AP와 PA방향으로 입사하는 0.05MeV에서 10MeV의 에너지 범위를 가진 넓고 평행한 단일 에너지 감마선장에 대해 MIRD팬텀과 Zubal팬텀의 장기선량을 MCNP4C를 이용하여 계산 및 비교한 결과 저에너지 영역에서 AP와 PA방향 모두 MIRD팬텀이 Zubal팬텀보다 높은 선량을 받았으며 유효선량의 경우 특히 PA방향, 0.05MeV 광자빔에 대해서 50%에 가까운 선량차이를 보였다 몸통부분 단층영상을 비교한 결과 Zubal팬텀에 비해서 MIRD팬텀의 몸통 두께가 얇아서 나타나는 결과임을 확인하게 되었고 MIRD몸통두께의 최적값을 찾아내기 위해 20cm에서 32cm까지 변화시켜가며 원전 작업환경에서 가장 많이 받게되는 0.5MeV 감마선에 대한 유효선량을 계산하여 비교하였다. AP방향에서는 24cm, PA방향에서는 28cm일 때 최소의 선량차이를 보이는 것으로 나타났고 이에 따라 몸통모델을 수정하였다. 수정된 MIRD팬텀을 이용하여 장기선량을 재계산하여 Zubal팬텀의 선량과 비교한 결과 특히 PA방향에서 큰 과대평가를 보였던 장기들의 선량차이가 현저하게 줄었고 유효선량의 경우 0.5 MeV 광자빔에 대해 AP, PA방향 각각 -0.5%와 7.3%의 낮은 선량차이를 보였다. Zubal팬텀에 의해 계산된 선량환산인자는 ICRP74에서 제공하는 값과 큰 차이를 보이고 있으며 수정된 MIRD팬텀은 Zubal팬텀의 값에 준하는 결과를 보였다. 본 연구에서 수정된 MIRD팬텀은 기존에 사용되던 선량환산계수의 수정에 사용될 수 있으며 수학적팬텀의 장점을 살리면서 실제 인체에 근접한 선량계산을 수행할 수 있다.