• Title/Summary/Keyword: External Implant

Search Result 171, Processing Time 0.029 seconds

Design of High Efficiency Differential Electromagnetic Type Transducer for Implantable Middle Ear System (이식형 인공중이 시스템을 위한 고효율 차동 전자 트랜스듀서의 설계)

  • Song, Byung-Seop;Ro, Chul-Kyun;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.171-182
    • /
    • 2002
  • The differential electromagnetic transducer for IME(implantable middle ear) system, which have two small permanent magnets glued with the same pole facing each other in the coil, has high vibration efficiency and does not influenced by external magnetic field. In this paper, using finite element method, highly efficient structure of the transducer was proposed and vibration force of the transducer was calculated by electromagnetic theory. And the necessary vibration force of transducer to transmit the sound signal to inner ear when the transducer is attached at stapes was calculated and the design parameters of the transducer were investigated. Using the parameters, the differential electromagnetic transducer was manufactured in small size to implant in confined human middle ear. And it was examined by unloaded and loaded vibration experiment using temporal bone sampled from cadaver.

Surface Tribology of Total Ankle Joint Replacement (인공발목관절의 표면 마모 특성)

  • Jeong, Yong-Hoon;Jung, Tae-Gon;Yang, Jae-Woong;Park, Kwang-Min;Lee, Su-Won
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.117-117
    • /
    • 2016
  • Total ankle replacement (TAR) is a visible option in the surgical treatment of degenerative or inflammatory diseases of ankle joint. it is attributed to the current TAR which has improvements in surgical technique, uncemented implant fixation and minimally constrained articulation. In the clinical result, they can show promised surgical result when compared to earlier attempts in TAR. However, TAR is still not as successful as total knee replacement (TKR) or total hip replacement (THR), it needs to be note that there are limitations in concerning of long term performance of TAR, the high failure rate still associated with wear of the PE (polyethylene) component that has related with their material property and surface roughness. The aim of this study was to introduce the tribology characteristics of total ankle joint prosthesis with one of TDR model which was fabricated to try multi-axis wear test as a region of motion in ankle joint. The wear specimen of TDR was prepared with Ti-6Al-4V alloy and UHMWPE (ultra-high molecular weight polyethylene) for tibia-talus and bearing component, respectively. A wear test was carried out using a Force 5 (AMTI, Massachusetts, US) wear simulator which can be allowed to move in three axis to flexion-extension ($+3^{\circ}{\sim}-6^{\circ}$), internal-external axial rotation (${\pm}5^{\circ}$), as well as sinusoidal compressive load (1.6 kN, R=10). All tests were performed following standard ISO 14243, wear rate was calculated with weight loss of UHMWPE bearing while the specimen has tested at certain cycles. As based on the preliminary results, wear rate of UHMWPE bearing was $7.9{\times}10^{-6}mg/cycles$ ($R^2=0.86$), calculated loss weight until $10^7cycles$ was 79 mg, respectively.

  • PDF

Consideration of Lateral Cortical Bone Thickness and IAN Canal Location During Mandibular Ramus Bone Grafting for Implant Placement

  • Lee, Nam-Hoon;Ohe, Joo-Young;Lee, Baek-Soo;Kwon, Yong-Dae;Choi, Byung-Joon;Bang, Sung-Moon
    • Journal of Korean Dental Science
    • /
    • v.3 no.2
    • /
    • pp.4-11
    • /
    • 2010
  • Purpose: This study aimed at examining the thickness of lateral cortical bone in the mandibular posterior body and the location of the inferior alveolar nerve canal as well as investigating the clinically viable bone grafting site(s) and proper thickness of the bone grafts. Subjects and Methods: The study enrolled a total of 49 patients who visited the Department of Oral and Maxillofacial Surgery at Kyung Hee University Dental Hospital to have their lower third molar extracted and received cone beam computed tomography (CBCT) examinations. Their CBCT data were used for the study. The thickness of lateral cortical bone and the location of inferior alveolar nerve canal were each measured from the buccal midpoint of the patients' lower first molar to the mandibular ramus area in the occlusal plane of the molar area. Results: Except in the external oblique ridge and alveolar ridge, all measured areas exhibited the greatest cortical bone thickness near the lower second molar area and the smallest cortical bone thickness in the retromolar area. The inferior alveolar nerve canal was found to be located in the innermost site near the lower second molar area compared to other areas. In addition, the greatest thickness of the trabecular bone was found between the inferior alveolar nerve canal and the lateral cortical bone. Conclusions: In actual clinical settings involving bone harvesting in the posterior mandibular body, clinicians are advised to avoid locating the osteotomy line in the retromolar area to help protect the inferior alveolar nerve canal from damage. Harvesting the bone near the lower second molar area is judged to be the proper way of securing cortical bone with the greatest thickness.

  • PDF

Clinical and Histopathological Study Using Platelet Rich Plasma and Bone Grafts in Extraction Sockets (발치와의 혈소판 농축 혈장과 골 이식술 시행시 골 형성에 대한 임상 및 조직병리학적 연구)

  • Jeon, Young-Tae;Chung, Chin-Hyung;Lee, Chong-Heon;Lim, Sung-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.2
    • /
    • pp.437-449
    • /
    • 2001
  • The socket preservation procedure was a simple and effective technique, and has better prognosis for implantation. The socket preservation usually used barrier membrane in combination with/without alloplastic bone materials. A recently study had shown that a regenerative therapy to tooth extraction utilizing growth factors made better results. Platelet-rich plasma was clinically easy method that acquired the growth factors, and is known that accelerated new bone formation and mineralization of bone graft materials. The purpose of this study was to evaluate clinical and histopathologic results which occur following socket preservations using platelet-rich plasma and bovine bone powder. Twelve patients who required extraction of one or more teeth for implantation at the department of periodontics in Dankook University Dental Hospital were selected. Extraction sockets were treated by using platelet-rich plasma and bovine bone powder. 3 months later, we observed clinical and histopathological results as follows: 1. Internal vertical measurement was an average of 7.33mm preoperatively and statistically significantly decreased to an average of 1.42mm postoperatively(p<0.05). 2. External vertical measurement was an average of 3.33mm preoperatively and decreased to an average of 2.75mm postoperatively; therefore there was no significant difference. 3. Horizontal measurement was an average of 7.75mm preoperatively and statistically decreased to an average of 6.08mm postoperatively(p<0.05). 4. Osteocyte-like cells and new bone formation connected with bovine bone grafts were observed in histopathologic examination. This study implied that platelet-rich plasma and bovine bone powder grafts were effective treatment for socket preservation and regeneration of severe bony defect made by implantation failure.

  • PDF

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Axial wall thickness of zirconia abutment in anterior region (전치부 지르코니아 지대주의 축벽 두께)

  • Moon, Seung-Jin;Heo, Yu-Ri;Lee, Gyeong-Je;Kim, Hee-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.345-351
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the proper axial thickness of zirconia abutment applied to implant in the anterior region. Materials and methods: Zirconia abutments were prepared at different axial wall thickness by processing pre-sintered zirconia blocks via CAD/CAM to obtain equal specimens. The abutments were each produced with a thickness of 0.5 mm (Group 1), 0.8 mm (Group 2), 1.2 mm (Group 3), or 1.5 mm (Group 4). The implant used in this study was a external connection type one (US, Osstem, Pussan, Korea) product and the zirconia abutment was prepared via replication of a cemented abutment. The crowns were prepared via CAM/CAM with a thickness of 1.5 mm and were cemented to the abutments using $RelyX^{TM}$ UniCem cement. A universal testing machine was used to apply load at 30 degrees and measure fracture strength of the zirconia abutment. Results: Fracture strength of the abutments for Group 1, Group 2, Group 3, and Group 4 were $236.00{\pm}67.55N$, $599.00{\pm}15.80N$, $588.20{\pm}33.18N$, and $97.83{\pm}98.13N$, respectively. Group 1 showed a significantly lower value, as compared to the other groups (independent Mann-Whitney U-test. P<.05). No significant differences were detected among Group 2, Group 3, and Group 4 (independent Mann-Whitney U-test. P>.05). Conclusion: Zirconia abutment requires optimal thickness for fracture resistance. Within the limitation of this study, > 0.8 mm thickness is recommended for zirconia abutment in anterior implants.

The Clinical Study of the Supracondylar Fracture of the Femur (대퇴골 과상부 골절 및 치료에 대한 임상적 고찰)

  • Ahn, Jong-Chul;Kim, Se-Dong;Ahn, Myun-Whan;Seo, Jae-Sung;Lee, Dong-Chul;Lee, Young-Joo
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.1
    • /
    • pp.197-211
    • /
    • 1993
  • Recently, the Supracondyle fracture of the femur is so severe and comminuted that it is difficult to treat open reduction and rigid fixation sufficiently due to violent traffic accident and external forces. The associated injuries are accompanied variously. So complications of the supracondyle fractures including joint stiffness, delayed union, infection are serious. However development of internal implant and operation skill result in relatively satisfactory function than conservative management. The authors reviewed 20 cases of the supracondyle fracture of the femur treated at Yeungnam University Hospital from 1989, Dec. To 1992, Jan. The results were as follows : 1. The male was common(70%). The 2nd-4th decade was most(87%). 2. The most common cause of injuries was traffic accident. The rate of open fracture was 35%, most of it was traffic accident. 3. According to the ASIF group classification. 4 cases were type A, 4 in type B, 12 in type C (10 in type $C_2$&$C_3$). 4. Accompanied injuries included multiple fractures in 9 cases and femoral artery injury in 1 case. 5. Among the 20 cases, conservative treatment was done in 5 cases and operative treatment was done in 15 cases. 6. Functional results (by Schatzker criteria) were as follows. The satisfactory results were achieved in 40% of cases in conservative treatment and 67% in operative treatment. 7. The average time of partial weight bearing was 15 weeks. 8. Complications were knee stiffness in 6 cases and 4 in delayed union.

  • PDF

The necessary & method of scrotoplasty in female to male transgender (여성에서 남성으로의 성전환증에서 음낭성형술의 필요성과 방법)

  • Kim, Seok-Kwun;Moon, In-Sun;Kwon, Yong-Seok;Lee, Keun-Cheol
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.437-444
    • /
    • 2009
  • Purpose: Transgender is a disorder of gender identity, who have appropriate chromosomal, hormonal and anatomical characteristics corresponding to their sexual phenotype but feel strongly with respect to their sexual identity, that they belong to the opposite sex. There is a persistence discomfort and sense of inappropriateness about one's assigned sex in a person who has reached puberty. Transgender is a psychiatric problem, but surgical method provides more satisfactory adjustment for patients. In gender reassignment surgery for female to male transgender, mastectomy, nipple reduction, hysterectomy, oophorectomy and phalloplasty are included. And as the final operation, recommended for scrotoplasty and artificial testes insertion. So we investigated the necessity and method of scrotoplasty in the final operation of female to male transgender. Method: The authors have long term follow-up of 75 cases female to male transgender during January, 1991 to February, 2008. Among them, 13 cases were evaluated in this study. During phalloplasty, the labium major skin preserved. And this labium majoral skin flap was made for the neoscrotum. At least six months later, artificial testes were inserted in neoscrotum with local anesthesia. Middle sized (3 cm diameter) artificial testes(silicon gel or carving soft silicone implant) were used because of the limitation of the neoscrotum. We evaluated the questionnaire and interview about the postoperative satisfaction in configuration of reconstructed scrotum, and the necessity of operation, the postoperative psychosocioeconomic improvement and limitation of body exposure activities such as swimming, public bathing. Results: Based on this study, satisfaction of reconstructed scrotum after scrotoplasty was improved(92%). The necessity of scrotoplasty was in 92.3% and the postoperative psychosocioeconomic well - being improvement was 77% in answers. Less limitation of activities requiring body exposure was 54% in answers. Most of the patients were satisfied with the results of surgical operation inspite of the operative procedure had some postoperative complications. Conclusion: This study was reported that the scrotoplasty in female to male transgender is not only a conversion of external genitalia but also an improvement of psychosocial state. Most patients sincerely hope to this operation, so we improve our surgical method for more good results.

Bone formation effect of $HA/{\beta}-TCP$ composite powders in rabbit calvarial bone defects;Histologic study (토끼의 두개골내에 형성된 골결손부에서 $HA/{\beta}-TCP$ composite powders의 골형성에 관한 조직학적 연구)

  • Lee, Kwang-Ho;Jang, Hyun-seon;Park, Joo-Cheol;Kim, Heung-Joong;Kim, Chong-Kwan;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.1
    • /
    • pp.1-14
    • /
    • 2006
  • The purpose of the present study was to evaluate the histologic results of bone cavities that were surgically created in the calvaria of rabbit and filled with $HA/{\beta}-TCP$ composite powders, which had been developed in Korea (Dentium, Korea). Ten young adult rabbits were used. Four defects were surgically produced in calvaria of each rabbit. Each rabbit was anesthetized with Ketamine-HCI (5 mg/kg, Yuhan Cor. Korea) and Xylazine-HCI (1.5 ml/kg, Yuhan Cor. Korea)). An incision was made to the bony cranium and the periosteum was reflected. Using a trephine bur (external diameter: 8 mm, 3i, USA), 4 'through-and-through' bone defects were created with copious irrigation, and classified into 4 groups: control group: no graft materials, experimental group I: normal saline + graft materials: experimental group II: venous blood + graft materials: experimental group III: graft materials only. The defects were randomly filled with graft materials. The defects were closed with resorbable suture material. At the end of the surgical procedure, all animals received a single intramuscular injection of antibiotics Gentamicin (0.1 mg/kg, Dae Sung Microb. Korea). Rabbits were sacrificed with phentobarbital (100 mg/kg) intravenously at 1-, 2-, 4-, 6- and 8-week after. Specimens were treated with hydrochloric acid decalcifying solution (Fisher Scientific, Tustin, CA) and sectioned by bisecting the 8 mm diameter defects. The histologic specimens were prepared in the general method with H & E staining at 6 ${\mu}m$ in thickness. The results were as follows; 1. New bone formation showed from after 2-week of surgery in defect area. As time lapsed, lots of new bone formation and mature bones showed. 2. Histologically, degree of new bone formation could not be discerned among the experimental groups. But, for experimental group II, lots of cells gathered around graft materials after 1-week of surgery, new bone formed slightly faster and than the others at 1-week after. For experimental group I, a few inflammatory finding showed around graft material at after 1-week and after 2-week of surgery. 3. No bone formation did show for control group. Based on histologic results, the new $HA/{\beta}-TCP$ composite powders appeared to act as a scaffolding material for regeneration of osseous defects.

Using a Kirschner wire as an internal splint at nasal fractures accompanied fracture of frontal process of maxilla or perpendicular plate of ethmoid (상악골 전두돌기 골절 및 사골 수직판 골절을 동반한 비골 골절에서 K 강선을 이용한 내고정)

  • Rho, Kyoung Hwan;Yoon, Eul Sik;Yoon, Byung Min;Dhong, Eun Sang
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.623-628
    • /
    • 2009
  • Purpose: In cases where nasal fractures involve frontal process of maxilla or perpendicular plate of ethmoid, 4 - 5 days of nasal packing may not provide sufficient support for avoiding displacement after packing removal. Therefore a single Kirschner - wire(K - wire) is used as an internal splint when nasal fractures involve the above two areas. Methods: Thirty five patients during the last 3 practical years were treated with a K -wire pinning according to the anatomic locations of nasal fractures. We performed a retrospective study using 13 nasal fractures out of total 35 patients. Among 13 cases, 10 patients involved frontal process of maxilla, and 3 patients were diagnosed as bilateral nasal side wall fractures accompanied with fractures of perpendicular plate of ethmoid. One patient of the last three cases had been augmented with dorsal silicone implant long before the trauma. We analyzed the anteroposterior displacement of key stone area and the width between both lateral walls by comparing immediate postoperative radiographs with 2 month follow - ups. To reduce the errors, the same measurements were taken by two different inspectors, and the mean of each inspector's measurements was compared. Patient satisfaction was analyzed using a questionnaire regarding the esthetic and functional outcomes. Results: Ten patients underwent a longitudinal K - wire fixation in submucoperiosteal plane underneath the frontal process of maxilla. And three patients underwent a transverse K - wire fixation from the one side of lateral wall to the perpendicular plate of ethmoid and to the other side of lateral wall. The mean postoperative anteroposterior displacement of the key stone area measured by two inspectors were 1.84% and 3.06%; mean narrowing of bony pyramid were 1.33% and 1.48%, respectively. Subjective satisfaction scores regarding the esthetic appearance and the maintenance of nasal shape compared with immediate post - operative state with the long term ones were not different (p>0.05). Conclusion: K - wire pinning after closed reduction is a reliable and useful method for the treatment of nasal fractures involving frontal process of maxilla or perpendicular plate of ethmoid. This is because it achieves longer intranasal support after reduction. This method also leaves conspicuous external scar, and minimal soft - tissue injury.