• 제목/요약/키워드: External Illuminance

검색결과 24건 처리시간 0.025초

태양의 위치에 따른 광파이프 시스템의 실내 주광환경평가 (Assessment of Daylight Environment on Light Pipe System Under Different Solar Position)

  • 신화영;김정태
    • 한국태양에너지학회 논문집
    • /
    • 제28권6호
    • /
    • pp.78-86
    • /
    • 2008
  • The aim of this paper is to show the daylight environment of a light pipe system according to sun movement. A light pipe system has been mounted on the roof of the windowless full scale model: the solar spot has diameter of 0.65m and is 1.3m long, giving an aspect ratio of 1:2. The full scale model was installed on the rooftop of the SHINAN apartment in Yongin city that has no obstructions against sunlight. The test room is equipped with sensors for the measurements of the internal illuminance and has an area of 6m(W)$\times$6m(D)$\times$4m(H). The system has been monitored with a data-logger to evaluate the cumulative distribution of illuminance on a floor-plane from 16th, April to 29th, May, 2008 over one month and selected clear sky condition. For the daylight performance of floor area, the totally 49 measuring points has been used to determine the internal illuminance and an HP datalogger(HP34970A) records the measurements for one consecutive month. The horizontal external illuminance has been measured with two outdoor sensors. This paper presents the results of monitoring light pipe system with internal/external illuminance ratio and cumulative frequency distribution of floor-plane illuminance are discussed The results show that lightpipe is proficient device for introducing daylight into the building. However It provided different daylight indoor environment with wide or narrow Interquatile range of illuminance, internal/external illuminance ratio and cumulative frequency distribution according to solar positions under suuny sky condition. For more achieving the improvement of lightpipes also include energy savings, user visual comfort with various indicators; seasonal solar height, room and lightpipes geometries.

도시공원의 공간별 적정조도 (A Study on Suitable Illuminance by Spaces in Urban Parks)

  • 김진선;최연철
    • 한국조경학회지
    • /
    • 제32권5호
    • /
    • pp.23-34
    • /
    • 2004
  • In this study, 1 dependent variable and 9 independent variables were established to examine suitable illuminance by spaces in urban parks in consideration of night users' psychological reactions and activity types. Such fixed variables were evaluated by a series of experiments of changing illuminance, and correlation among those variables was verified by correlation analysis and multiple regression analysis to suggest suitable illuminance by spaces. The results of this study are as follows: 1) The independent variables influencing suitable illuminance by spaces in urban parks were directly influenced rather by the psychological reaction of night users than the activity types by spatial functions. 2) Securing suitable illuminance by spaces commonly increased spatial availability, created certain atmosphere, and provided safety in the psychological reaction of night users. 3) Suitable illuminance by spaces in urban parks is: Central square is 31.88lx, resting space 6.30lx, exercising space 33.14lx, children's playground 14.19lx, pedestrian road 12.29lx, entry space 16.30lx, and green space 7.03lx. That is, when a place had more positive activities, spatial illuminance was increased. 4) Though comparison by spaces with the illuminance standard for urban parks as mentioned in KS A 3011-1993 can not be made, such illuminance was relatively compatible with the permissible range of illuminance in the author's opinion. It is expected that this study investigating suitable illuminance by spaces for night use in urban parks, will provide necessary knowledge for securing suitable illuminance by spaces in urban parks through classifyingin detail the illuminance standard of KS A 3011-1993. Besides, by helping make us aware of the importance of illuminance in urban parks as well as of external space in the night, this study will contribute to academic research and development in the field of landscape architecture and associated fields and be utilized in establishing legal and institutional standards.

학교 건물에서 외부 차양 장치 유형에 따른 일반교실 내 빛환경 특성에 관한 연구 (A Study on the Characteristics of Daylighting Environment in Classroom of an School Building Due to the External Shading Devices)

  • 임재한;정진주;이지영
    • 교육시설
    • /
    • 제15권2호
    • /
    • pp.4-15
    • /
    • 2008
  • The purpose of this study was to evaluate the characteristics of daylighting environment in classroom of an school building due to the external shading devices such as fixed louvers, light shelves and exterior venetian blinds. In this study, we have made a field research with regard to the facade design in classroom of an school building. And we have made a classification of external shading devices considering the design parameters. Finally, through RADIANCE simulation, we have calculated the spatial distribution of illuminance, uniformity ratio of illuminance and daylight factors. The results of this study will provide the building designer with the basic daylighting performance data at early design stages.

수직형 라이트파이프의 채광성능에 관한 예비평가 (Preliminary Field Test on Daylighting Performance of Perpendicular Light Pipe System)

  • 신혜미;박훈;김정태
    • KIEAE Journal
    • /
    • 제8권1호
    • /
    • pp.53-60
    • /
    • 2008
  • The daylighting affects on the human biological cycles and physiological alterations. Daylighting is also an important element in visual comfort and it sometimes influences the quality of vision. Therefore the absence of natural light during the day brings contradictory result. To solve the problems of natural light lack and provide sufficient daylight in interior spaces, it might be necessary to apply some daylighting systems. One of these systems, light pipe system, which is simple, cheep and easily constructed, is very useful to apply for small buildings. The light pipe is simple means of directing daylighting (diffuse and direct lighting)into interior space. In order to application of light pipe system in Korea, it is necessary to optical data of light pipe system. This study aims to evaluate preliminary experiment of the daylighting environment of light pipe system. Light pipe system, that aspect ratio is 1:2(diameter and length), was installed in a windowless mock-up with $27m^2$. The mock-up model was constructed as a prototype of Korean office surface. Illuminance was measured with a Topcon IM-5 Luxmeter to evaluate the distribution of the illuminance on a floor. The indoor and outdoor illuminance and the internal/external illuminance ratio are compared to discuss with in the graphs. Luminance was measured with Radiant imaging Promertric 1400 that is digital photometer to evaluate the distribution of luminance on interior surface. The contrast of luminance is discussed with table and graphs.

Optimum Control of a Photoelectric Dimming System in a Small Office with a Double Skin Envelope

  • Kim, Soo Young;Yum, Sung Kon
    • Architectural research
    • /
    • 제7권2호
    • /
    • pp.47-54
    • /
    • 2005
  • A photoelectric dimming control system for a small private office space with a double skin envelope system was analyzed for the purpose of examining optimum control performances under a variety of daylight conditions. Computer simulations were performed for the three different photosensor types positioned at the center of ceiling in the space. They were applied in both a south and north-facing room. Daylight conditions were a fixed horizontal venetian blind on an external envelope and a retractable shading device on an internal envelope under a clear, intermediate and overcast sky at different times of a day and year. Partially-shielded photosensors provided good control performances providing the required electric light output under clear and intermediate sky conditions. Unshielded photosensors failed to provide necessary illuminance levels producing less electric output and fully-shielded photosensors generally provided excessive light output. Reasonable electric lighting energy savings were achieved except under overcast sky conditions where the control system did not contribute to energy savings due to the less daylight through envelopes. The retractable shading device covering 50% of the internal envelope reduced energy savings up to 19.62%, but the workplane illuminance levels were maintained within recommended ranges. The coefficients of determination between workplane illuminance and photosensor illuminance due to daylight ranged from 0.74 to 0.98. Partially-shielded conditions provided best correlations and the north-facing room yielded stronger correlation than the south-facing room.

주행 중 운전자의 HUD 인지성과 활용성 평가 (Evaluation for the cognition and usability of HUD while driving)

  • 윤보람;박다은;김보경;조주영;박영경
    • 감성과학
    • /
    • 제17권3호
    • /
    • pp.117-128
    • /
    • 2014
  • 자동차사고의 주요 원인으로 운전자의 주의분산이 지목됨이 따라 운전자의 전방주시율을 높여주는 HUD(Head Up Display)에 대한 중요성이 높아지고 있다. 최근에는 다양한 콘텐츠가 포함된 HUD 제품들이 등장하면서 주행중 인지부하가 증가할 가능성이 높아졌다. 이에 본 논문은 현재 자동차에 사용되고 있는 HUD에 제시된 콘텐츠가 운전자에게 미치는 영향에 대해 알아보기 위하여 조도환경과 성별의 차이를 두어 인지적 측면과 활용적 측면에 대한 실험을 진행하였다. 실험 결과, HUD가 제공하는 콘텐츠는 외부 조도와 차량 내의 내부 조도의 차이가 클수록 시인성이 높아 인지부하가 줄어들었다. 또한 HUD 콘텐츠의 경우 주행과 직접적인 관련이 높을수록 인지율이 높았으며, 운전과 관련성이 낮은 콘텐츠의 경우 운전자의 집중을 저해하는 것을 확인하였다.

조도 분포 변수를 이용한 형상 알고리즘 개발 및 디자인 구현에 관한 연구 (A Study on the Shape Design Implementation and the Algorithm Development using the Illuminance Distribution)

  • 지승열;전한종
    • KIEAE Journal
    • /
    • 제12권1호
    • /
    • pp.35-43
    • /
    • 2012
  • Algorithm-based architecture helps specifically dividing the environmental variables of a target space into individual factors to build object-oriented programming, classifying them into an individual object according to the environmental variables of each planning circumstance, and distributing each structure into small structures. In addition, each itemized matter of construction is set as a condition, and thus it is possible to respond to the space condition of various circumstances which occur in the architectural planning process. This study is intended for predicting that a sketch role in the design process can be replaced by a design method utilizing an algorithm, through the external solar radiation and the illuminance value of indoor lighting device among the environmental variables of a target space, and for seeking a way to create a design alternative and improve the design quality by using computer-based algorithm design.

스마트 윈도우 설치 속성에 따른 사무공간의 주광 환경 추이 (Trends of Daylight Environment for Office Spaces Based on Smart-Window Installation Settings)

  • 김재향;한승훈
    • 신재생에너지
    • /
    • 제19권3호
    • /
    • pp.13-21
    • /
    • 2023
  • Smart windows are capable of varying their visible light transmittance (VLT) in response to changing environmental conditions. The VLT variability of architectural windows is highly valuable because it enables indoor lighting and energy environments to align with external changes. However, challenges such as high installation costs and assurance of glass visibility have prompted the exploration of alternative solutions, including models incorporating partially applied smart windows., Prior research focused on useful daylight illuminance (UDI) analysis for south-facing office buildings, pointing out suitable areas for smart-window implementation to enhance lighting control. In this study, we broadened this scope by determining optimal smart-window application zones under changing building orientation. Furthermore, we studied the correlation between building orientation and smart-window deployment areas.

실내·외 조도에 따른 스테레오 CCTV 영상 정합점 수 변화 (Changes in the Number of Matching Points in CCTV's Stereo Images by Indoor/Outdoor Illuminance)

  • 문광일;편무욱;김종화;김강산
    • 대한공간정보학회지
    • /
    • 제23권1호
    • /
    • pp.129-135
    • /
    • 2015
  • 도시기반시설에 첨단 정보통신기술을 융합하여 언제 어디서나 자유롭게 서비스를 제공하고자 하는 U-City(Ubiquitous City)의 공간정보기술은 다양한 형태로 서비스 되고 있다. 그 중에서도 U-City에서 가장 많이 설치되어 있는 CCTV(Closed Circuit TV)의 스테레오 영상을 가지고 특징점(Key Point)을 선정하여 정합(Matching)하고 3차원 공간정보를 구축하는 연구가 진행되고 있다. 하지만 대부분 정합점을 추출하는데 사용된 데이터는 조도와 같은 외부 환경영향을 고려하지 않고 있다. 본 논문은 동일한 하드웨어에서 조도의 변화에 의해 영상의 질이 좌우되는 CCTV를 가지고 3차원 공간정보를 구축하는데 필요한 정합점이 조도에 따라 얼마나 변화 하는지 실험을 하였다. 조도에 따른 정합점 수의 분석 결과, 카메라의 조리개, 셔터속도, 감도를 고정하였을 때 3,000Lux까지 정합점 수가 조도에 비례하여 높아 졌으며, 물체와 배경의 경계가 뚜렷해졌다. 반대로 빛이 과도하게 들어 왔을 경우 화면이 밝이지며, 노이즈가 발생하고 사물과 사물의 경계가 없어져 특징점을 선정하기가 힘들었다. 본 논문에서 얻어진 결과를 이용하여 촬영할 경우 향상된 정합점을 가질 수 있을 것으로 기대된다.

터널조명 측정을 통한 조도와 휘도기반의 조명 비교 연구 (Comparison Research between Lighting Based on luminance and Illuminance through Measuring Tunnel Lighting)

  • 이미애;한승훈;김연화
    • 조명전기설비학회논문지
    • /
    • 제27권11호
    • /
    • pp.14-19
    • /
    • 2013
  • Tunnel lighting design and operation are both regulated based on luminance in and out of Korea these days. However, domestic tunnel lighting is operated by internal lighting depending on external brightness by using an illuminometer applying the conversion factor on luminance. The purpose of tunnel lighting is to alleviate the visual shock occurring from the rapid change from external brightness to internal brightness when entering a tunnel. However, when looking at the tunnels operated based on an illuminometer, it is not a system where the driver can measure the brightness within his or her viewing angle when entering the tunnel. It is general to install and operate the illuminometer on the roof of an administrative office near the tunnel; however, this method is not structured to connect with the internal lighting by checking the brightness of the viewing scope of the driver, thus is not structured to properly apply the viewing conditions of the driver. Rather, it should be in a method for extracting the luminance value within the viewing scope of the driver pursuant to tunnel lighting standards and in connection with internal lighting. This research seeks to find the difference between operations based on luminance and operations based on intensity of Illuminance in road tunnels through field measuring, and to suggest the necessity of operating based on luminance with the resulting value.