• 제목/요약/키워드: Exterior retrofit

검색결과 18건 처리시간 0.02초

Comparative performance of seismically deficient exterior beam-column sub-assemblages of different design evolutions: A closer perspective

  • Kanchana Devi, A.;Ramanjaneyulu, K.
    • Earthquakes and Structures
    • /
    • 제13권2호
    • /
    • pp.177-191
    • /
    • 2017
  • In the present study, exterior beam column sub-assemblages are designed in accordance with the codal stipulations prevailed at different times prior to the introduction of modern seismic provisions, viz., i) Gravity load designed with straight bar anchorage (SP1), ii) Gravity load designed with compression anchorage (SP1-D), iii) designed for seismic load but not detailed for ductility (SP2), and iv) designed for seismic load and detailed for ductility (SP3). Comparative seismic performance of these exterior beam-column sub-assemblages are evaluated through experimental investigations carried out under repeated reverse cyclic loading. Seismic performance parameters like load-displacement hysteresis behavior, energy dissipation, strength and stiffness degradation, and joint shear deformation of the specimens are evaluated. It is found from the experimental studies that with the evolution of the design methods, from gravity load designed to non-ductile and then to ductile detailed specimens, a marked improvement in damage resilience is observed. The gravity load designed specimens SP1 and SP1-D respectively dissipated only one-tenth and one-sixth of the energy dissipated by SP3. The specimen SP3 showcased tremendous improvement in the energy dissipation capacity of nearly 2.56 times that of SP2. Irrespective of the level of design and detailing, energy dissipation is finally manifested through the damage in the joint region. The present study underlines the seismic deficiency of beam-column sub-assemblages of different design evolutions and highlights the need for their strengthening/retrofit to make them fit for seismic event.

그린리모델링 성과 평가 관점에서 본 준공 시점 단열 성능 검증의 중요성 (Importance of Preliminary Validation of Exterior Wall Thermal Resistance in the Evaluation Context of Building Energy Retrofit Projects)

  • 임승민;김소연;강창오;김가인;임종연
    • 토지주택연구
    • /
    • 제15권2호
    • /
    • pp.29-37
    • /
    • 2024
  • 본 논문에서는 공공건축물 그린리모델링 과정에서 철거되는 단열재 샘플을 수거하여 열전도율과 밀도 등 단열성능과 관련된 물성치에 대한 측정 결과를 제시하였다. 단열재의 장기 열저항은 제조 초기 단계의 열전도율을 추정하기 위한 자료가 남아있지 않다는 한계로 인해 정확한 변화 양상을 도출하기 어려웠지만, 설계도서를 통해 추정한 정보에 기반하여 비드법 단열재의 경우 기존 지식과 동일하게 설치 후 10년 이상 경과 시 성능변화가 크지 않다는 결과를 얻을 수 있었다. 하지만 동일 등급, 동일 경과 기간의 단열재에서 측정된 열전도율의 편차가 크고, 특히 단열재 샘플의 밀도가 설계도서상에 기재된 설치 단열재의 등급 기준에 크게 못 미친다는 결과를 얻었다. 준공 시점 및 운영 단계의 성능 관리가 되지 않고 있다는 것을 보여주는 실험 결과이며, 그린리모델링 등 건축물에너지 성능 개선을 적절히 평가하기 위해서는 건물생애주기에 걸친 성능 검증인 빌딩커미셔닝의 적용이 중요하다.

기계학습 기반 노후 철근콘크리트 건축물의 축력허용범위 산정 방법 (ML-based Allowable Axial Loading Estimation of Existing RC Building Structures)

  • 황희진;오근영;강재도;신지욱
    • 한국지진공학회논문집
    • /
    • 제28권5호
    • /
    • pp.257-266
    • /
    • 2024
  • Due to seismically deficient details, existing reinforced concrete structures have low lateral resistance capacities. Since these building structures suffer an increase in axial loads to the main structural element due to the green retrofit (e.g., energy equipment/device, roof garden) for CO2 reduction and vertical extension, building capacities are reduced. This paper proposes a machine-learning-based methodology for allowable ranges of axial loading ratio to reinforced concrete columns using simple structural details. The methodology consists of a two-step procedure: (1) a machine-learning-based failure detection model and (2) column damage limits proposed by previous researchers. To demonstrate this proposed method, the existing building structure built in the 1990s was selected, and the allowable range for the target structure was computed for exterior and interior columns.

고인성섬유 복합모르타르를 활용한 고강도 철근콘크리트 외부 보-기둥 접합부의 내진성능평가 (Evaluation of Seismic Performance of High Strength Reinforced Concrete Exterior Beam-Column Joints Using High Ductile Fiber-Reinforced Mortar)

  • 하기주;신종학
    • 콘크리트학회논문집
    • /
    • 제25권4호
    • /
    • pp.419-428
    • /
    • 2013
  • 이 연구에서는 고강도 철근콘크리트 외부 보-기둥 접합부의 시공성 및 내진성능을 개선하기 위하여 보-기둥 접합부 영역의 스터럽 및 띠철근 유무에 따라 고인성섬유 복합모르타르를 사용하여 내진성능을 평가하였다. 총 5개의 실험체를 제작하고 실험을 수행하여 내진성능을 평가하였으며, 이 연구의 시험 결과를 근거로 다음과 같은 결론을 얻었다. 기존 고강도 철근콘크리트 내부 보-기둥 접합부의 위험단면 영역을 고인성섬유 복합모르타르로 보강한 결과 재하 전 과정을 통하여 섬유의 가교역할로 인한 균열 분산효과로 인하여 균열 제어 효과가 커서 안정적인 파괴형태 및 내력을 나타내었다. 고강도 철근콘크리트 외부 보-기둥 접합부의 시공성 및 내진성능을 개선하기 위하여 고인성섬유 복합모르타르를 사용하여 보강한 실험체(BCJNSP 시리즈)는 스터럽과 띠철근이 제거 되었음에도 안정적인 이력거동을 나타내었고, 최대내력이 전단보강근이 없는 실험체 BCJNS의 1.09~2.03배로 증가하였다. 그리고 고인성섬유 복합모르타르를 사용하여 보강한 실험체(BCJNSP 시리즈)는 표준실험체 BCJC의 최대내력이 0.92~0.96배로 거의 비슷하였고, 에너지소산능력은 최대 1.62배로 크게 증가하였다.

기존 공동 주택의 벽체 열성능 현장 측정법에 관한 연구 (The study of in-situ measurement method for wall thermal performance diagnosis of existing apartment)

  • 김서훈;김종훈;류승환;정학근;송규동
    • KIEAE Journal
    • /
    • 제16권4호
    • /
    • pp.71-77
    • /
    • 2016
  • Purpose : The energy saving in a residential building (apartment) sector is known as one of the effective solution of energy reduction. In South Korea, the government has recently reinforced regulations associated with the energy performance of buildings. However, there is a lack of research on the methods for the energy performance diagnosis that is used to analyze the wall thermal performance of the existing apartments. Because a reliable diagnosis is necessary to save the building energy, this study analyzed wall thermal performance of an existing apartment in Seoul. Method : This paper applied two methods for analysis of the thermal insulation performance; HFM(Heat Flow Meter) method and ASTR(Air-Surface Temperature Ratio) method. The HFM method is suggested by ISO9869-1 code to measure the thermal performance. The ASTR method is proposed by this study for the simplified In-situ measurement and it uses three temperature data (interior wall surface, interior and exterior air) and the overall heat transfer coefficient. This study conducted the experiment of an existing apartment in Seoul using these methods and analyzed the results. Furthermore, the energy simulation tool of the building was used to suggest retrofit of the building based on the results of measurements. Result : The error rate of HFM method and ASTR method was analyzed in about 17 to 20%. As the results of comparison between the initial design values of the wall and the measured values, the 26% degradation of insulation thermal performance was measured. Lastly, the energy simulation tool of the building shows 10.8% energy savings in accordance with the construction of suggested retrofit.

Experimental and numerical verification of hydraulic displacement amplification damping system

  • Chung, Tracy Sau-Kwai;Lam, Eddie Siu-Shu;Wu, Bo;Xu, You-Lin
    • Structural Engineering and Mechanics
    • /
    • 제33권1호
    • /
    • pp.1-14
    • /
    • 2009
  • Hong Kong is now recognized as an area of moderate seismic hazard, but most of the buildings have been designed with no seismic provision. It is of great significance to develop effective and practical measures to retrofit existing buildings against moderate seismic attacks. Researches show that beam-column joints are critical structural elements to be retrofitted for seismic resistance for reinforced concrete frame structures. This paper explores the possibility of using a Hydraulic Displacement Amplification Damping System (HDADS), which can be easily installed at the exterior of beam-column joints, to prevent structural damage against moderate seismic attacks. A series of shaking table tests were carried out with a 1/3 prototype steel frame have been carried out to assess the performance of the HDADS. A Numerical model representing the HDADS is developed. It is also used in numerical simulation of the shaking table tests. The numerical model of the HDADS and the numerical simulation of the shaking table tests are verified by experimental results.

Preference of User Groups on Facade Elements of Remodeled Factories in Korea

  • Liu, Yuanzhao;Park, Changbae
    • Architectural research
    • /
    • 제24권2호
    • /
    • pp.29-40
    • /
    • 2022
  • The transition from manufacturing to service-based economies in highly developed societies during the post-industrial period resulted in the decline of the industrial landscape, leaving it abandoned or underutilized. In pursuit of revitalizing the obsolete industrial space, innovative design techniques based on adaptive reuse are applied to retrofit modern functions to create a new cultural space and preserve the historical, symbolic, and cultural importance of the abandoned industrial facilities. Design considerations based on facade redesign have proven to be one of the most adopted techniques that can help in recreating a new function for the vacant industrial buildings and integrating them into the present-day urban fabric. This paper examines the facade renovation elements used for the adaptive reuse of 15 abandoned industrial buildings presently used as multi-purpose facilities in South Korea. Through a questionnaire survey, this study analyzes the respondents' preference for different facade renovation elements in the 15 sites according to age and gender. The study found that both genders showed similar preference patterns between most elements. But on some elements, females were keener and expressed a stronger opinion than males. There were much more females than males who perceived color and material as the most important exterior elements. The findings of this study can be used for the adaptive reuse of industrial buildings according to user preferences for different facade renovation elements.

Development of a retrofit anchor system for remodeling of building exteriors

  • Yeun, Kyu Won;Hong, Ki Nam;Kim, Jong
    • Structural Engineering and Mechanics
    • /
    • 제44권6호
    • /
    • pp.839-856
    • /
    • 2012
  • To enable remodeling of the exterior of buildings more convenient, such finishing materials as curtain walls, metal panels, concrete panels or dry stones need to be easily detached. In this respect, this study proposed a new design of the slab for the purposes. In the new design, the sides of the slab were properly modified, and the capabilities of anchors fixed in the modified slab were experimentally tested. In details, a number of concrete specimens with different sizes and compressive strengths were prepared, and the effect of anchors with different diameters and embedment depths applied in the concrete specimens were tested. The test results of the maximum capacities of the anchors were compared with the number of current design codes and the stress distribution was identified. This study found that the embedment depth specified in the current design code (ACI318-08) should be revised to be more than 1.5 times the edge distance. However, with the steel sheet reinforcement, the experiment acquired higher tensile strength than the design code proposed. In addition, for two types of specimens in the tensile strength experiment, the current design code (ACI 318-08) is overestimated for the anchor depth of 75 mm. This study demonstrated that the ideal breakout failure was attainable for the side slot details of a slab with more than 180 mm of a slab thickness and less than 75 mm of an anchor embedment depth. It is expected that these details of the modified slab can be specified in the upgraded construction design codes.