• Title/Summary/Keyword: Exterior joint

Search Result 164, Processing Time 0.029 seconds

Reliability Assessment of Lead-contained and Lead-free BGA Solder Joints under Cyclic Bending Loads (굽힘 하중하에서 유연 및 무연 솔더 조인트의 신뢰성 평가)

  • Kim Il-Ho;Lee Soon-Bok
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.13 no.1 s.38
    • /
    • pp.63-72
    • /
    • 2006
  • Mobile products, such as cellular phones, PDA and notebook, are subjected to many different mechanical loads, which include bending, twisting, impact shock and vibration. In this study, a cyclic bending test of the BGA package was performed to evaluate the fatigue life. Special bending tester, which was suitable for electronic package, was developed using an electromagnetic actuator. A nonlinear finite element model was used to simulate the mechanical bending deformation of solder joint in BGA packages. The fatigue life of lead-free (95.5Sn4.0Ag0.5Cu) solder joints was compared with that of lead-contained (63Sn37Pb). When the applied load to the specimen is small, the lead-free solder has longer fatigue life than lead-contained solder. The fatigue crack is initialized at the exterior solder joints and is propagated into the inner solder joints.

  • PDF

Analysis of Causes of Casualties in Jecheon Sports Center Fire - Focus on Structural Factors of Building and Equipment - (제천 스포츠센터 화재의 다수 사상자 발생원인 분석 - 건물과 설비의 구조적인 요인을 중심으로 -)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.86-94
    • /
    • 2018
  • A sports center fire in Jecheon caused 29 deaths and 40 injuries. This study focused only on the structural factors of the building and equipment to investigate the causes of casualties based on the fire investigation results at the sports center. The structural factors of the building and equipment were a piloti-type parking lot, lack of a fire compartment between the piloti-type parking lot and lobby, lack of an installed sprinkler system, lack of an installed fire door in the main stairs on the $1^{st}$ floor, lack of an installed fire water tank on the rooftop, an installed pocket fire door in the main entrance on the $2^{nd}$ floor, poor fire compartments in an EPS space and a pipe pit and on each floor, a leak in the joint of a drain pipe, plywood installed in the hoistway of the freight elevator and interior wall, illegal remodeling of a closed rooftop structure, which cannot discharge smoke and heat, installed styrofoam insulation in the inside of the parking lot ceiling, an installed tempered glass window, which cannot be opened in the ladies bathroom on the $2^{nd}$ floor, and a finished dryvit exterior wall.

An Experimental Study on the Bond Strengths for Concrete Filled Steel Tube Columns using a Push-Out Test (단순가력실험을 통한 콘크리트충전 강관기둥의 부착응력에 관한 연구)

  • Woo, Hae Sung;Kim, Jin Ho;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.4
    • /
    • pp.481-487
    • /
    • 2002
  • Currently, the load transfer's mechanism from a beam to a column has yet to ve clarified in a concrete filled steel tubular (CFT) structure with a connection type of an exterior diaphragm. The loads for each floor are transferred to the concrete core from a steel beam through ha contacted face between an in-filled concrete and the interior surface of a steel tube. Thus, a Push-Out test was performed to investigate the load transfer mechanism. A total of 30 samples were tested to confirm the bond stress and/or axial load distribution between a steel tube and in-filled concrete for CFT column. The main parameters considered for this study included concrete type, steel tube-shape/length, and the effect of a weld joint wit ha backing strip for a column splice. Test results were summarized to confirm load transfer behavior between a concrete and steel tube for each experimental parameter, using the analytical approach to verify experimental results.

FE Analysis of Exterior Wide Beam-Column Connections with Bonded Tendon Stress (부착된 프리스트레스 넓은 보-기둥 외부접합부의 유한요소해석)

  • Lee, Moon-Sung;Choi, Yun-Cheul;Lim, Jaei-Hyung;Moon, Jeong-Ho;Choi, Chang-Sick
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.4
    • /
    • pp.307-315
    • /
    • 2008
  • Post-tensioned precast concrete system (PPS) consists of U-shaped precast wide beams and concrete column. The continuity of beam-column joint is provided with the topping concrete on the PC shell beam and post-tensioning. Nonlinear analysis was conducted, using ANSYS, a finite-element analysis program, to obtain data for determining the characteristics of the structure and to allow various parametric analyses for post-tensioned wide beam-column connections. In this analysis, the Solid 65 element was used, in which concrete element had 8 nodes and each node had 3 degrees of freedomIn. Solid 65, the shear-transfer factor reflects a decrease of shear strength for the positions with cracks, as an impact factor to make the analysis value approximate the experiment value. In this study, the behavior of test specineus were most closely predicted to the experimental results, when the shear-transfer coefficient 0.85 was used for a closed crack, and 0.2 was used for an open crack.

A Study of Ginger Herbal Pharmacopuncture for Practical Application (생강 약침의 임상적 활용을 위한 고찰)

  • Lee, Chae-Woo;Lee, Byung-Hoon;Youn, Hyoun-Min
    • Journal of Pharmacopuncture
    • /
    • v.12 no.1
    • /
    • pp.43-51
    • /
    • 2009
  • Objective : The purpose of this study is to present the standard for practical application of ginger herbal pharmacopuncture Material and Methods : We refer to ancient literatures and the recent papers for ginger. Conclusions : The following results have been obtained 1. The effect of ginger(Zingiber officinale Roscoe) is to "release exterior", "balance nutrient & defensive qi", "resolve phlegm", "arrest coughing", "warm the lungs". So ginger herbal pharmacopuncture can be applied to treating fever, chilling sign, headchae, snuffle and gasping cough due to cold affection and treating the symptoms like sputum and asthma that be revealed by pulmonary disease. 2. The effect of ginger is to "warm spleen and stomach", "arrest vomiting" "promote normal flow of water". So ginger herbal pharmacopuncture can be applied to treating nausea, vomiting, abdominal distension and diarrhea due to phlegm & dampness and treating edema. 3. The effect of ginger is to eliminate blood stasis. So ginger herbal pharmacopuncture can be applied to treating contusion, blood stasis, sprain and gynecologic disease. 4. Ginger can treat myalgia and pain due to wind-damp and have anti-inflammatory effect in pharmacology. So ginger herbal pharmacopuncture can be applied to treating disease of joint, ligament and muscle. 5. Ginger can resolve phlegm and resuscitate. So ginger herbal pharmacopuncture can be applied to treating unconsciousness. But, treating incipient cardiovascular accident, it needs to call your special attention to the danger of blood pressure increase. 6. In pharmacology, ginger is effective for antitumor, antioxidant effects and activating immunocyte. So ginger herbal pharmacopuncture can be applied to treating broadly varieties of tumor and allergic disease.

Connections between RC beam and square tubed-RC column under axial compression: Experiments

  • Zhou, Xu-Hong;Li, Bin-Yang;Gan, Dan;Liu, Jie-Peng;Chen, Y. Frank
    • Steel and Composite Structures
    • /
    • v.23 no.4
    • /
    • pp.453-464
    • /
    • 2017
  • The square tubed-reinforced concrete (TRC) column is a kind of special concrete-filled steel tube (CFST) columns, in which the outer thin-walled steel tube does not pass through the beam-column joint, so that the longitudinal steel reinforcing bars in the RC beam are continuous through the connection zone. However, there is a possible decrease of the axial bearing capacity at the TRC column to RC beam connection due to the discontinuity of the column tube, which is a concern to engineers. 24 connections and 7 square TRC columns were tested under axial compression. The primary parameters considered in the tests are: (1) connection location (corner, exterior and interior); (2) dimensions of RC beam cross section; (3) RC beam type (with or without horizontal haunches); (4) tube type (with or without stiffening ribs). The test results show that all specimens have relatively high load-carrying capacity and satisfactory ductility. With a proper design, the connections exhibit higher axial resistance and better ductility performance than the TRC column. The feasibility of this type of connections is verified.

A Study of Joint Reliability According to Various Cu Contents between Electrolytic Ni and Electroless Ni Pad Finish (전해Ni, 무전해 Ni pad에서의 Cu 함량에 따른 접합 신뢰성에 관한 연구)

  • Lee, Hyun Kyu;Chun, Myung Ho;Chu, Yong Chul;Oh, Kum-Sool
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.3
    • /
    • pp.51-56
    • /
    • 2015
  • It has been used various pad finish materials to enhance the reliability of solder joint and recently Electroless Ni Electroless Pd Immersion Gold (the following : ENEPIG) pad has been used more than others. This study is about reliability according to being used in commercial Electrolytic Ni pad and ENEPIG pad, and was observed behavior of various Cu contents. After reflow, the inter-metallic compound (IMC) between solder and pad is composed of $Cu_6Sn_5$ (Ni substituted) by using EDS, and in case of ENEPIG, between IMC and Ni layer was observed the dark layer ($Ni_3P$ layer). Additional, it could be controlled the thickness of dark layer according to Cu contents. Investigated the different fracture mode between electrolytic Ni and ENEPIG pad after drop shock test, in case of soft Ni, accelerated stress propagated along the interface between $1^{st}$ IMC and $2^{nd}$ IMC, and in case of ENEPIG pad, accelerated stress propagated along the weaken surface such as dark layer. The unstable interface exists through IMC, pad material and solder bulk by the lattice mismatch, so that the thermal and physical stress due to the continuous exterior impact is transferred to the IMC interface. Therefore, it is strongly requested to control solder morphology, IMC shape and thickness to improve the solder reliability.

A Study of Postural Control Characteristics in Schoolchild with Intellectual Disability (초등학교 지적장애아동의 자세조절 특성)

  • Lee, Hyoung Soo
    • 재활복지
    • /
    • v.14 no.3
    • /
    • pp.225-256
    • /
    • 2010
  • This study aims to provide the basic data of the rehabilitation program for the schoolchild with intellectual disability by designing new framework of the features of postural control for the schoolchild with intellectual disability. For this, the study investigated what sensations the schoolchild are using to maintain posture by selectively or synthetically applying vision, vestibular sensation and somato-sensation, and how the coordinative sensory system of the schoolchild is responding to any sway referenced sensory stimulus. The study intended to prove the limitation of motor system in estimating the postural stability by providing the cognitive motor task, and provided the features of postural control of the schoolchild with intellectual disability by measuring the onset times and orders of muscle contraction of neuron-muscle when there is a postural control taking place due to the exterior disturbance. Furthermore, by comparatively analyzing the difference between the normal schoolchild and the intellectually disabled schoolchild, this study provided an optimal direction for treatment planning when the rehabilitation program is applied in the postural control ability training program for the schoolchild with intellectual disability. Taking gender and age into consideration, 52 schoolchild including 26 normal schoolchild and 26 intellectually disabled schoolchild were selected. To measure the features of postural control, CTSIB test, and postural control strategy test were conducted. The result of experiment is as followed. First, the schoolchild with intellectual disability showed different feature in using sensory system to control posture. The normal schoolchild tended to depend on somato-sensory or vision, and showed a stable postural control toward a sway referenced stimulus on somato-sensory system. The schoolchild with intellectual disability tended to use somato-sensory or vision, and showed a very instable postural control toward a sway referenced vision or a sway referenced stimulus on somato-sensory system. In sensory analysis, the schoolchild with intellectual disability showed lower level of proficiency in somato-sensation percentile, vision percentile and vestibular sensation percentile compare to the normal schoolchild. Second, as for the onset times and orders of muscle contraction for strategies of postural control when there is an exterior physical stimulus, the schoolchild with intellectual disability showed a relatively delayed onset time of muscle control, and it was specially greater when the perturbation is from backward. As for the onset orders of muscle contraction, it started from muscles near coax then moved to the muscles near ankle joint, and the numbers and kinds of muscles involved were greater than the normal schoolchild. The normal schoolchild showed a fast muscle contracting reaction from every direction after the perturbation stimulus, and the contraction started from the muscles near the ankle joint and expanded to the muscles near coax. From the results of the experiments, the special feature of the postural control of the schoolchild with intellectual disability is that they have a higher dependence on vision in sensory system, and there was no appropriate integration of swayed sensation observed in upper level of central nerve system. In the motor system, the onset time of muscle contraction for postural control was delayed, and it proceeded in reversed order of the normal schoolchild. Therefore, when use the clinical physical therapy to improve the postural control ability, various sensations should be provided and should train the schoolchild to efficiently use the provided sensations and use the sensory experience recorded in upper level of central nerve system to improve postural control ability. At the same time, a treatment program that can improve the processing ability of central nerve system through meaningful activities with organizing and planning adapting reaction should be provided. Also, a proprioceptive motor control training program that can induce faster muscle contraction reaction and more efficient onset orders from muscularskeletal system is need to be provided as well.

Development Strengths of High Strength Headed Bars of RC and SFRC Exterior Beam-Column Joint (RC 및 SFRC 외부 보-기둥 접합부에 대한 고강도 확대머리 철근의 정착강도)

  • Duck-Young Jang;Jae-Won Jeong;Kang-Seok Lee;Seung-Hun Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.94-101
    • /
    • 2023
  • In this study, the development performance of the head bars, which is SD700, was experimentally evaluated at the RC (reinforced concrete) or SFRC (steel fiber reinforced concrete external beam-column joint. A total of 10 specimens were tested, and variables such as steel fibers, length of settlement, effective depth of the beam, and stirrups of the column were planned. As a result of the experiment, the specimens showed side-face blowout, concrete breakout, and shear failure depending on the experimental variables. In the RC series experiments with development length as a variable, it was confirmed that the development strength increased by 26.5~42.2% as the development length increased by 25-80%, which was not proportional to the development length. JD-based experiments with twice the effective depth of beams showed concrete breakout failure, reducing the maximum strength by 31.5% to 62% compared to the reference experiment. The S-series experiment, in which the spacing of the shear reinforcement around the enlarged head reinforcement was 1/2 times that of the reference experiment, increased the maximum strength by 8.4 to 9.7%. The concrete compressive strength of SFRC was evaluated to be 29.3% smaller than the concrete compressive strength of RC, but the development strength of SFRC specimens increased by 7.3% to 12.2%. Accordingly it was confirmed that the development performance of the head bar was greatly improved by reinforcing the steel fiber. Considering the results of 92% and 99% of the experimental maximum strength of the experiment arranged with 92% and 110% of the KDS-based settlement length, it is judged that the safety rate needs to be considered even more. In addition, it is required to present a design formula that considers the effective depth of the beam compared to the development length.

Inelastic Behavior of Beam-Column Joints Composed of RC Column and RS Beams (RC 기둥과 RS 보로 이루어진 보-기둥 접합부의 비탄성 거동)

  • 김욱종;윤성환;문정호;이리형
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.734-741
    • /
    • 2002
  • An experimental study was carried out for beam-column joints composed of RC column and RS beams. The purpose of this study is to examine the inelastic seismic behavior for the RC-RS connection. Two interior and one exterior beam-column assemblies with variable moment ratios were tested. Experimental results showed that strength and deformability except stiffness were satisfactory. It is considered that the lack of stiffness was due to the slipping of steel beam from RS beam. The behavioral characteristics of the RC-RS connection were evaluated according to the quideline suggested by Hawkins et al. Nominal strength at 5 % joint distortion was not satisfactory, but all the other requirements, such as strength preserving capability, energy dissipation, and initial stiffness and strength ratios after peak load were satisfactory compared with the guideline. Thus it was concluded that the RC-RS connections can maintain ductility with excellent energy-dissipating capacity if being provided with appropriate reinforced structural system such as RC core wall for the initial lateral stiffness.